@article{SteiningerGadererDawoudetal., author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal and Gaderer, Matthias}, title = {Experimental and numerical study on the solar gain and heat loss of typical existing and refurbished German buildings}, series = {iCRBE Procedia}, volume = {1}, journal = {iCRBE Procedia}, number = {1}, publisher = {Weentech}, doi = {10.32438/icrbe.202035}, pages = {75 -- 93}, abstract = {This communication introduces an experimental setup for investigating the effect of solar radiation on the reduction of transmission heat losses and the steady state thermal conductance of uninsulated and insulated multi-layer wall samples. The setup consists of two adjacent climatic chambers, which share a common wall, in which the multi-layer wall samples are mounted. A solar simulator is applied within the outdoor air climatic chamber, whose radiation spectrum and radiation intensity are approximately equivalent to those of the sun. The first tests have been carried out on a wall sample with a typical structure of existing buildings from the year 1930 in Germany. In addition, a high-performance insulating plaster layer has been applied on a basic test sample (with existing building structure) to replicate and assess the refurbished scenario. Furthermore, a numerical investigation on the transient heat transfer process is carried out by using the simulation software COMSOL Multiphysics®. The experimental results of both uninsulated and insulated wall samples are validated against 1D and 3D models. As seen, the uninsulated wall, whose thermal conductance was experimentally determined to be equal to 1.79 W/(m²K), absorbs a heat flux of 208 W/m² through its external wall surface over a period of 8 hours. A fraction of 9.8 \% of the absorbed heat arrives as a gain on the internal wall and reduces the transmission heat losses by 11.7 \% over a period of 55 hours. On the other hand, the thermal conductivity of the insulation layer of the refurbished wall sample with micro hollow glass spheres was estimated by a parameter estimation procedure using the 3D model and the obtained experimental data. Using the estimated thermal conductivity, a thermal conductance of 0.42 W/(m²K) has been obtained for the refurbished wall sample.}, language = {en} } @misc{SchwanzerDietrichGadereretal., author = {Schwanzer, Peter and Dietrich, Markus and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Detektion unterschiedlicher Medien in Gasoline Particulate Filter (GPF) mit Hilfe eines Radio-Frequenz (RF-) Sensors}, series = {Bayerische Wissenschaftsforum - BayWISS 2020}, journal = {Bayerische Wissenschaftsforum - BayWISS 2020}, language = {de} } @misc{SchwanzerDietrichGadereretal., author = {Schwanzer, Peter and Dietrich, Markus and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Monitoring von Partikelfiltern f{\"u}r den Einsatz in Fahrzeugen mit direkt- einspritzenden Ottomotoren mit einer Radio-Frequenz (RF-) Antenne}, series = {Kolloquium des Bayerischen Wissenschaftsforum}, journal = {Kolloquium des Bayerischen Wissenschaftsforum}, language = {de} } @misc{SchwanzerDietrichHaftetal., author = {Schwanzer, Peter and Dietrich, Markus and Haft, Gerhard and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Oxidation Kinetics Determination of GDI Engine Soot by a Radio-Frequency Sensor}, series = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, journal = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, language = {en} } @misc{SchwanzerMieslingerRabletal., author = {Schwanzer, Peter and Mieslinger, Johann and Rabl, Hans-Peter and Dietrich, Markus and Haft, Gerhard and Walter, Stefanie and Hagen, Gunter and Moos, Ralf and Gaderer, Matthias}, title = {Monitoring of a Particulate Filter for Gasoline Direct Injection Engines with a Radio-Frequency-Sensor}, series = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, journal = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, abstract = {In order to comply with future emission regulations, the use of particulate filters in vehicles with direct injection gasoline engines is essential. The current amount of soot and ash in the filter is calculated by a soot load model in the electronic control unit in combination with a differential pressure sensor determining the pressure drop over the particulate filter. Active regeneration is initiated if the calculated amount of soot or the measured differential pressure is too high. This is associated with additional fuel consumption. An on-board diagnosis for the particulate filter is currently not part of the Euro 6d emission standard. For future exhaust emission standards, on-board diagnosis or active monitoring of the particulate filter is conceivable. One of the benefits of monitoring is the fact that unnecessary active regenerations can be avoided. As a result, there is no additional fuel consumption due to misinterpretations of the amount of soot in the filter. For active monitoring of the particulate filter, a radiofrequency (RF-) sensor, that detects the soot loading of the filter with electromagnetic waves directly, can be used. Such a system has the advantage that by utilizing the filter as a sensor more precise information about the current state of the filter, e.g. a possible damage, can be provided. Worst-case considerations of filter damages, tested at an engine test bench show the advantages which are entailed by a system like that. By means of partial regeneration of the particulate filter it is demonstrated how the remaining amount of soot in the filter can be detected in a better way in comparison to the differential pressure sensor by using the RF-sensor.}, language = {en} } @article{SchwanzerRablLodersetal., author = {Schwanzer, Peter and Rabl, Hans-Peter and Loders, S. and Seifert, P. and Himmelstoss, S. and Gaderer, Matthias}, title = {Difference in the Tailpipe Particle Number by Consideration of Sub-23-nm Particles for Different Injection Settings of a GDI Engine}, series = {Emission control science and technology}, volume = {5}, journal = {Emission control science and technology}, number = {1}, publisher = {Springer Nature}, doi = {10.1007/s40825-019-0114-1}, pages = {7 -- 22}, abstract = {The purpose of this study was to investigate the characteristic of nanoparticles under consideration of sub-23-nm particles from a 1.8-l direct injection (DI) gasoline engine under stoichiometric air/fuel conditions in the exhaust gas system. For future CO2 challenges, the usage of DI-instead of port fuel injection (PFI)-gasoline engines is unavoidable. Therefore, a state of the art particle management program-particle number (PN) system, the Horiba SPCS (2100) with an integrated CPC (condensation particle counter), was recalibrated from a 50\% cutoff (D-50\%) at 23 nm down to a cutoff at 10 nm and the PCRF (particle concentration reduction factor) for sizes smaller than 23 nm was checked. Two different modal points, out of a representative Real Driving Emission (RDE) cycle, were investigated with both calibrations, D-50\%=10 nm and D-50\%=23 nm. For these different load points, the fuel pressure (FUP) and the start of injection (SOI) were varied, to represent the difference in the structure and the ratio conc((10 nm))/conc((23 nm)) of the nanoparticle emissions. The particle characterization includes the particle number (PN), the particle size distribution (PSD), and the particle mass (PM). The particle number was measured with Horiba SPCS (2100). The particle size distribution was analyzed with a Grimm differential mobility analyzer (DMA) in combination with a Faraday cup electrometer (FCE). Micro Soot and Pegasor were used to determine the PM, and an optical characterization was done with a 120-kV Phillips CM12 transmission electron microscope (TEM). The position of all particle measurement systems was downstream the three-way catalyst (TWC). The results of this investigation showed that a higher injection pressure decreases the PN (without consideration of sub-23-nm particles) in general. The ratio conc((10 nm))/conc((23 nm)) was therefore higher, because smaller particles, especially ash particles, were less reduced from the FUP. This means higher FUP tends to a higher ratio. For the SOI, the main reasons of the ratio differences were explained by an encroachment between the injection jet and the piston, the valve and the wall.}, language = {en} } @misc{AltmannRablGaderer, author = {Altmann, Robert and Rabl, Hans-Peter and Gaderer, Matthias}, title = {Ph{\"a}nomenologische Untersuchung des Einspritzverhaltens von Pflanzen{\"o}lkraftstoff}, series = {3. Tagung der Fuels Joint Research Group (FJRG) "Kraftstoffe f{\"u}r die Mobilit{\"a}t von Morgen"}, journal = {3. Tagung der Fuels Joint Research Group (FJRG) "Kraftstoffe f{\"u}r die Mobilit{\"a}t von Morgen"}, language = {de} } @misc{AltmannGadererRabl, author = {Altmann, Robert and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Pr{\"u}fstandsuntersuchungen an einem DEUTZ NRMM Motor mit Raps{\"o}lkraftstoff und Optimierung des Betriebs- und Emissionsverhaltens durch statistische Versuchsplanung}, series = {18. Internationaler Fachkongress "Kraftstoffe der Zukunft 2021" - digital \& international vernetzt!, online}, journal = {18. Internationaler Fachkongress "Kraftstoffe der Zukunft 2021" - digital \& international vernetzt!, online}, language = {de} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental Investigation of the Adsorption and Desorption Kinetics on an Open-Structured Asymmetric Plate Heat Exchanger; Matching Between Small-Scale and Full-Scale Results}, series = {Frontiers in Energy Research}, volume = {10}, journal = {Frontiers in Energy Research}, publisher = {Frontiers}, doi = {10.3389/fenrg.2022.818486}, pages = {1 -- 15}, abstract = {This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3\% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1\%.}, language = {en} } @article{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Assessment of the Annual Transmission Heat Loss Reduction of a Refurbished Existing Building with an Advanced Solar Selective Thermal Insulation System}, series = {Sustainability}, volume = {13}, journal = {Sustainability}, number = {13}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/su13137336}, pages = {1 -- 19}, abstract = {A numerical parameter sensitivity analysis of the design parameters of the recently published solar selective thermal insulation system (SATIS) has been carried out to enhance its thermal and optical properties. It turned out that the insulation properties of SATIS can be effectively improved by reducing the length of the glass closure element. Increasing the area share of the light conducting elements (LCEs) and decreasing their length-to-diameter (L/D) ratio were identified as key parameters in order to increase the solar gain. Two SATIS variants were compared with the same wall insulation without SATIS in a yearly energetic performance assessment. The SATIS variant with 10 mm length of the closure element, 44.2\% area share of LCE, as well as front and rear diameters of 12 mm/9 mm shows an 11.8\% lower transmission heat loss over the heating period than the wall insulation without SATIS. A new methodology was developed to enable the implementation of the computed solar gains of SATIS in 1D simulation tools. The result is a radiant heat flow map for integration as a heat source in 1D simulation models. A comparison between the 1D and 3D models of the inside wall heat fluxes showed an integral yearly agreement of 98\%.}, language = {en} }