@misc{SchwanzerDietrichGadereretal., author = {Schwanzer, Peter and Dietrich, Markus and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Detektion unterschiedlicher Medien in Gasoline Particulate Filter (GPF) mit Hilfe eines Radio-Frequenz (RF-) Sensors}, series = {Bayerische Wissenschaftsforum - BayWISS 2020}, journal = {Bayerische Wissenschaftsforum - BayWISS 2020}, language = {de} } @misc{SchwanzerDietrichGadereretal., author = {Schwanzer, Peter and Dietrich, Markus and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Monitoring von Partikelfiltern f{\"u}r den Einsatz in Fahrzeugen mit direkt- einspritzenden Ottomotoren mit einer Radio-Frequenz (RF-) Antenne}, series = {Kolloquium des Bayerischen Wissenschaftsforum}, journal = {Kolloquium des Bayerischen Wissenschaftsforum}, language = {de} } @misc{SchwanzerDietrichHaftetal., author = {Schwanzer, Peter and Dietrich, Markus and Haft, Gerhard and Gaderer, Matthias and Rabl, Hans-Peter}, title = {Oxidation Kinetics Determination of GDI Engine Soot by a Radio-Frequency Sensor}, series = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, journal = {23rd Conference on Combustion Generated Nanoparticles 2019, June 17-20, Z{\"u}rich, Switzerland}, language = {en} } @misc{SchwanzerMieslingerRabletal., author = {Schwanzer, Peter and Mieslinger, Johann and Rabl, Hans-Peter and Dietrich, Markus and Haft, Gerhard and Walter, Stefanie and Hagen, Gunter and Moos, Ralf and Gaderer, Matthias}, title = {Monitoring of a Particulate Filter for Gasoline Direct Injection Engines with a Radio-Frequency-Sensor}, series = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, journal = {11th International Exhaust Gas and Particulate Emissions Forum, 3.-4.3.2020, Ludwigsburg, Germany}, abstract = {In order to comply with future emission regulations, the use of particulate filters in vehicles with direct injection gasoline engines is essential. The current amount of soot and ash in the filter is calculated by a soot load model in the electronic control unit in combination with a differential pressure sensor determining the pressure drop over the particulate filter. Active regeneration is initiated if the calculated amount of soot or the measured differential pressure is too high. This is associated with additional fuel consumption. An on-board diagnosis for the particulate filter is currently not part of the Euro 6d emission standard. For future exhaust emission standards, on-board diagnosis or active monitoring of the particulate filter is conceivable. One of the benefits of monitoring is the fact that unnecessary active regenerations can be avoided. As a result, there is no additional fuel consumption due to misinterpretations of the amount of soot in the filter. For active monitoring of the particulate filter, a radiofrequency (RF-) sensor, that detects the soot loading of the filter with electromagnetic waves directly, can be used. Such a system has the advantage that by utilizing the filter as a sensor more precise information about the current state of the filter, e.g. a possible damage, can be provided. Worst-case considerations of filter damages, tested at an engine test bench show the advantages which are entailed by a system like that. By means of partial regeneration of the particulate filter it is demonstrated how the remaining amount of soot in the filter can be detected in a better way in comparison to the differential pressure sensor by using the RF-sensor.}, language = {en} } @article{SchwanzerRablLodersetal., author = {Schwanzer, Peter and Rabl, Hans-Peter and Loders, S. and Seifert, P. and Himmelstoss, S. and Gaderer, Matthias}, title = {Difference in the Tailpipe Particle Number by Consideration of Sub-23-nm Particles for Different Injection Settings of a GDI Engine}, series = {Emission control science and technology}, volume = {5}, journal = {Emission control science and technology}, number = {1}, publisher = {Springer Nature}, doi = {10.1007/s40825-019-0114-1}, pages = {7 -- 22}, abstract = {The purpose of this study was to investigate the characteristic of nanoparticles under consideration of sub-23-nm particles from a 1.8-l direct injection (DI) gasoline engine under stoichiometric air/fuel conditions in the exhaust gas system. For future CO2 challenges, the usage of DI-instead of port fuel injection (PFI)-gasoline engines is unavoidable. Therefore, a state of the art particle management program-particle number (PN) system, the Horiba SPCS (2100) with an integrated CPC (condensation particle counter), was recalibrated from a 50\% cutoff (D-50\%) at 23 nm down to a cutoff at 10 nm and the PCRF (particle concentration reduction factor) for sizes smaller than 23 nm was checked. Two different modal points, out of a representative Real Driving Emission (RDE) cycle, were investigated with both calibrations, D-50\%=10 nm and D-50\%=23 nm. For these different load points, the fuel pressure (FUP) and the start of injection (SOI) were varied, to represent the difference in the structure and the ratio conc((10 nm))/conc((23 nm)) of the nanoparticle emissions. The particle characterization includes the particle number (PN), the particle size distribution (PSD), and the particle mass (PM). The particle number was measured with Horiba SPCS (2100). The particle size distribution was analyzed with a Grimm differential mobility analyzer (DMA) in combination with a Faraday cup electrometer (FCE). Micro Soot and Pegasor were used to determine the PM, and an optical characterization was done with a 120-kV Phillips CM12 transmission electron microscope (TEM). The position of all particle measurement systems was downstream the three-way catalyst (TWC). The results of this investigation showed that a higher injection pressure decreases the PN (without consideration of sub-23-nm particles) in general. The ratio conc((10 nm))/conc((23 nm)) was therefore higher, because smaller particles, especially ash particles, were less reduced from the FUP. This means higher FUP tends to a higher ratio. For the SOI, the main reasons of the ratio differences were explained by an encroachment between the injection jet and the piston, the valve and the wall.}, language = {en} } @article{SchwanzerSchillingerMieslingeretal., author = {Schwanzer, Peter and Schillinger, Maximilian and Mieslinger, Johann and Walter, Stefanie and Hagen, Gunter and Maerkl, Susanne and Haft, Gerhard and Dietrich, Markus and Moos, Ralf and Gaderer, Matthias and Rabl, Hans-Peter}, title = {A Synthetic Ash-Loading Method for Gasoline Particulate Filters with Active Oil Injection}, series = {SAR International Journal of Engines}, volume = {14}, journal = {SAR International Journal of Engines}, number = {4}, publisher = {SAE International}, issn = {1946-3936}, doi = {10.4271/03-14-04-0029}, pages = {493 -- 506}, abstract = {To reduce particulate emissions, the use of particulate filters in diesel engines is meanwhile state of the art, while the integration of such systems in gasoline engines is now also necessary in order to comply with today's regulations. Over its lifetime, a gasoline particulate filter (GPF) collects ash components of fuel, lubrication oil, and materials originating from the catalytic coating and from engine abrasion. In the development and application process, synthetic ashing from GPFs is challenging. The ash of the lubrication oil can be increased in various ways, like oil-doped fuel, a separate oil burner, or changes in the piston-cylinder system of the engine. However, these methods show major disadvantages. For this reason, an improved approach is presented in this study, which allows a quick response to changes in combustion (e.g., engine knocking) and producing ash, which is more realistic due to its primary particle size and the density of ash plugs, in a shorter time. Therefore, an approach to accelerate ash loading by active oil injection using a multi-point injection (MPI) system is introduced. With the help of this methodology, an ashing capacity of 1.21 g/h is implemented, which is a high rate compared to other investigations. The primary particle size (evaluated by means of a transmission electron microscope), is in the same size range as those detected at the full-load curve during regular operation. A computer tomographic (CT) analysis of the incinerated particulate filter also shows that a very high density of ash plugs can be realized, which has also been found in the literature for real applications. In addition, with the help of a mass spectrometer (MS) and an intermediate weighing of the particulate filter, the current ash loading of the GPF could be determined with an accuracy of 1\%.}, language = {en} }