@misc{EbigboRauberAyoubetal., author = {Ebigbo, Alanna and Rauber, David and Ayoub, Mousa and Birzle, Lisa and Matsumura, Tomoaki and Probst, Andreas and Steinbr{\"u}ck, Ingo and Nagl, Sandra and R{\"o}mmele, Christoph and Meinikheim, Michael and Scheppach, Markus W. and Palm, Christoph and Messmann, Helmut}, title = {Early Esophageal Cancer and the Generalizability of Artificial Intelligence}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1783775}, pages = {S428}, abstract = {Aims Artificial Intelligence (AI) systems in gastrointestinal endoscopy are narrow because they are trained to solve only one specific task. Unlike Narrow-AI, general AI systems may be able to solve multiple and unrelated tasks. We aimed to understand whether an AI system trained to detect, characterize, and segment early Barrett's neoplasia (Barrett's AI) is only capable of detecting this pathology or can also detect and segment other diseases like early squamous cell cancer (SCC). Methods 120 white light (WL) and narrow-band endoscopic images (NBI) from 60 patients (1 WL and 1 NBI image per patient) were extracted from the endoscopic database of the University Hospital Augsburg. Images were annotated by three expert endoscopists with extensive experience in the diagnosis and endoscopic resection of early esophageal neoplasias. An AI system based on DeepLabV3+architecture dedicated to early Barrett's neoplasia was tested on these images. The AI system was neither trained with SCC images nor had it seen the test images prior to evaluation. The overlap between the three expert annotations („expert-agreement") was the ground truth for evaluating AI performance. Results Barrett's AI detected early SCC with a mean intersection over reference (IoR) of 92\% when at least 1 pixel of the AI prediction overlapped with the expert-agreement. When the threshold was increased to 5\%, 10\%, and 20\% overlap with the expert-agreement, the IoR was 88\%, 85\% and 82\%, respectively. The mean Intersection Over Union (IoU) - a metric according to segmentation quality between the AI prediction and the expert-agreement - was 0.45. The mean expert IoU as a measure of agreement between the three experts was 0.60. Conclusions In the context of this pilot study, the predictions of SCC by a Barrett's dedicated AI showed some overlap to the expert-agreement. Therefore, features learned from Barrett's cancer-related training might be helpful also for SCC prediction. Our results allow different possible explanations. On the one hand, some Barrett's cancer features generalize toward the related task of assessing early SCC. On the other hand, the Barrett's AI is less specific to Barrett's cancer than a general predictor of pathological tissue. However, we expect to enhance the detection quality significantly by extending the training to SCC-specific data. The insight of this study opens the way towards a transfer learning approach for more efficient training of AI to solve tasks in other domains.}, language = {en} } @misc{ScheppachMendelRauberetal., author = {Scheppach, Markus W. and Mendel, Robert and Rauber, David and Probst, Andreas and Nagl, Sandra and R{\"o}mmele, Christoph and Meinikheim, Michael and Palm, Christoph and Messmann, Helmut and Ebigbo, Alanna}, title = {Artificial Intelligence (AI) improves endoscopists' vessel detection during endoscopic submucosal dissection (ESD)}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1782891}, pages = {S93}, abstract = {Aims While AI has been successfully implemented in detecting and characterizing colonic polyps, its role in therapeutic endoscopy remains to be elucidated. Especially third space endoscopy procedures like ESD and peroral endoscopic myotomy (POEM) pose a technical challenge and the risk of operator-dependent complications like intraprocedural bleeding and perforation. Therefore, we aimed at developing an AI-algorithm for intraprocedural real time vessel detection during ESD and POEM. Methods A training dataset consisting of 5470 annotated still images from 59 full-length videos (47 ESD, 12 POEM) and 179681 unlabeled images was used to train a DeepLabV3+neural network with the ECMT semi-supervised learning method. Evaluation for vessel detection rate (VDR) and time (VDT) of 19 endoscopists with and without AI-support was performed using a testing dataset of 101 standardized video clips with 200 predefined blood vessels. Endoscopists were stratified into trainees and experts in third space endoscopy. Results The AI algorithm had a mean VDR of 93.5\% and a median VDT of 0.32 seconds. AI support was associated with a statistically significant increase in VDR from 54.9\% to 73.0\% and from 59.0\% to 74.1\% for trainees and experts, respectively. VDT significantly decreased from 7.21 sec to 5.09 sec for trainees and from 6.10 sec to 5.38 sec for experts in the AI-support group. False positive (FP) readings occurred in 4.5\% of frames. FP structures were detected significantly shorter than true positives (0.71 sec vs. 5.99 sec). Conclusions AI improved VDR and VDT of trainees and experts in third space endoscopy and may reduce performance variability during training. Further research is needed to evaluate the clinical impact of this new technology.}, language = {en} }