@inproceedings{AlMunajjedNolteRasmussenetal., author = {Al-Munajjed, Amir Andreas and Nolte, Daniel and Rasmussen, John and Dendorfer, Sebastian}, title = {Force distribution in the foot during braking - a musculoskeletal approach}, series = {Human Modeling Symposium 2014, Munich, Germany}, booktitle = {Human Modeling Symposium 2014, Munich, Germany}, abstract = {High loads can appear in the individual joints of the human foot while the driver uses the pedals, in particular, during breaking. Measuring these internal forces is very difficult or almost impossible; therefore, advanced models are necessary to perform musculoskeletal simulations. The objective of this investigation was to see what loads are acting in the individual foot joints from the phalanges to calcaneus and talus during different brake scenarios. The Glasgow-Maastricht AnyBody Foot Model with 26 separate segments, connected by joints, ligaments and muscles was used inside the AnyBody Modeling System to compute individual mid foot joint loads. The amount, the direction of the force and additionally also the load insertion point was varied for several simulations. Figure 1: Seated musculoskeletal body model with applied brake force and forces for the lateral, intermediate and medial cuneiform-navicular joint for two different brake forces. The simulation showed that for the different brake scenarios, different muscles will be activated in the human and therefore different loads are apply in the fore-and mid-foot, respectively. The torso of the subject was assumed to be fixed in the seat. Further studies are ongoing to simulate the seat as an elastic element that allows different H-point locations according to the different loadings in the foot from the brake pedal using a new inverse dynamics analysis method called force-dependent kinematics.}, language = {en} } @inproceedings{AndersendeZeeDendorferetal., author = {Andersen, Michael Skipper and de Zee, Mark and Dendorfer, Sebastian and MacWilliams, Bruce and Rasmussen, John}, title = {Validation of a detailed lower extremity model based on the Klein Horsman data set}, series = {Proceedings of the 12th International Symposium on Computer Simulation in Biomechanics (ISB 2009), July 2nd - 4th 2009, Cape Town, South Africa}, booktitle = {Proceedings of the 12th International Symposium on Computer Simulation in Biomechanics (ISB 2009), July 2nd - 4th 2009, Cape Town, South Africa}, pages = {27 -- 28}, language = {en} } @misc{AuerKrutschRenkawitzetal., author = {Auer, Simon and Krutsch, Werner and Renkawitz, Tobias and Kubowitsch, Simone and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Effect of mental demand on leg loading in highly dynamic motion}, series = {AnyBody online Webinar, Oct 2020}, journal = {AnyBody online Webinar, Oct 2020}, abstract = {Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.}, language = {en} } @inproceedings{AuerKubowitschKrutschetal., author = {Auer, Simon and Kubowitsch, Simone and Krutsch, Werner and Renkawitz, Tobias and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Effect of mental demand on knee forces in professional youth soccer players}, series = {ISBS Proceedings Archive}, volume = {38}, booktitle = {ISBS Proceedings Archive}, number = {1, Art. 28}, abstract = {Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand.}, subject = {Kniegelenk}, language = {en} } @article{AuerKurbowitschSuessetal., author = {Auer, Simon and Kurbowitsch, Simone and S{\"u}ß, Franz and Renkawitz, Tobias and Krutsch, Werner and Dendorfer, Sebastian}, title = {Mental stress reduces performance and changes musculoskeletal loading in football-related movements}, series = {Science and Medicine in Football}, volume = {5}, journal = {Science and Medicine in Football}, number = {4}, publisher = {Taylor \& Francis}, doi = {10.1080/24733938.2020.1860253}, pages = {323 -- 329}, abstract = {Purpose: Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Hence, this study investigated the musculoskeletal response of elite youth football players during highly dynamic movements under stress. The hypothesis is that mental stress reduces performance and changes the muscular forces exerted. Materials \& methods: Twelve elite youth football players were subjected to mental stress while performing sports-specific change-of-direction movements. A modified version of the d2 attention test was used as stressor. The kinetics are computed using inverse dynamics. Running times and exerted forces of injury-prone muscles were analysed. Results: The stressor runs were rated more mentally demanding by the players (p = 0.006, rs = 0.37) with unchanged physical demand (p = 0.777, rs = 0.45). This resulted in 10\% longer running times under stress (p < 0.001, d = -1.62). The musculoskeletal analysis revealed higher peak muscle forces under mental stress for some players but not for others. Discussion: The study shows that motion capture combined with musculoskeletal computation is suitable to analyse the effects of stress on athletes in highly dynamic movements. For the first time in football medicine, our data quantifies an association between mental stress with reduced football players' performance and changes in muscle force.}, language = {en} } @misc{AuerNieblerEiglspergeretal., author = {Auer, Simon and Niebler, Michael and Eiglsperger, Josef and Kubowitsch, Simone and Renkawitz, Tobias and Achenbach, Leonard and Krutsch, Werner and Dendorfer, Sebastian}, title = {Cognitive stress increases muscle forces in dynamic football specific movements}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @misc{AuerReinkerDendorfer, author = {Auer, Simon and Reinker, Lukas and Dendorfer, Sebastian}, title = {Evaluation of muscle recruitment and muscle models in musculoskeletal simulation of dynamic motion}, series = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, journal = {26th Congress of the European Society of Biomechanics, July 11-14, 2021, Milan, Italy}, address = {Milan}, pages = {8}, abstract = {Musculoskeletal simulation plays an increasingly important role in sports biomechanics. In the last years, the field of application widened from orthopaedics and ergonomics to sports [1]. A muscle recruitment algorithm with a quadratic objective function is usually used to calculate muscle activity in dynamic movements. The agreement of calculated and measured thigh muscle activity has already been investigated [2]. They found a strong agreement for sprinting and running, while the correlation decreased for side-cutting manoeuvres. Nevertheless, the influence of different muscle recruitment criteria on muscle activity in dynamic musculoskeletal simulations is currently unknown. Hence, this study aimed to analyse the effect of different muscle recruitment criteria and muscle models on the correlation of numerical and measured muscle activity in highly dynamic movements.}, language = {en} } @misc{AuerReinkerSuessetal., author = {Auer, Simon and Reinker, Lukas and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Comparing calculated and measured muscle activity of thigh muscles in dynamic motion.}, series = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, journal = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, pages = {640}, language = {en} } @misc{AuerReinkerSuessetal., author = {Auer, Simon and Reinker, Lukas and S{\"u}ß, Franz and Kubowitsch, Simone and Krutsch, Werner and Weber, Markus and Renkawitz, Tobias and Dendorfer, Sebastian}, title = {Webcast: Effect of mental demand on leg loading in highly dynamic motion}, abstract = {Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.}, language = {en} } @article{AuerSchieblIversenetal., author = {Auer, Simon and Schiebl, Jonas and Iversen, Kristoffer and Subhash Chander, Divyaksh and Damsgaard, Michael and Dendorfer, Sebastian}, title = {Biomechanical assessment of the design and efficiency of occupational exoskeletons with the AnyBody Modeling System}, series = {Zeitschrift f{\"u}r Arbeitswissenschaften}, volume = {76}, journal = {Zeitschrift f{\"u}r Arbeitswissenschaften}, number = {4}, publisher = {Springer Nature}, doi = {10.1007/s41449-022-00336-4}, pages = {440 -- 449}, abstract = {Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose. Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.}, language = {en} } @inproceedings{AurbachJungtaeublSpickaetal., author = {Aurbach, Maximilian and Jungt{\"a}ubl, Dominik and Spicka, Jan and Dendorfer, Sebastian}, title = {EMG-based validation of musculoskeletal models considering crosstalk}, series = {World Congress Biomechanics, 28-30 June 2018, Dublin}, booktitle = {World Congress Biomechanics, 28-30 June 2018, Dublin}, doi = {10.1109/BIOMDLORE.2018.8467211}, abstract = {BACKGROUND: Validation and verification of multibody musculoskeletal models sEMG is a difficult process because of the reliability of sEMG data and the complex relationship of muscle force and sEMG. OBJECTIVE: This work aims at comparing experimentally recorded and simulated muscle activities considering a numerical model for crosstalk. METHODS: For providing an experimentally derived reference data set, subjects were performing elevations of the arm, where the activities of the contemplated muscle groups were measured by sEMG sensors. Computed muscle activities were further processed and transformed into an artificial electromyographical signal, which includes a numerical crosstalk model. In order to determine whether the crosstalk model provides a better agreement with the measured muscle activities, the Pearson correlation coefficient has been computed as a qualitative way of assessing the curve progression of the data sets. RESULTS: The results show an improvement in the correlation coefficient between the experimental data and the simulated muscle activities when taking crosstalk into account. CONCLUSIONS: Although the correlation coefficient increased when the crosstalk model was utilized, it is questionable if the discretization of both, the crosstalk and the musculoskeletal model, is accurate enough.}, language = {en} } @article{AurbachSpickaSuessetal., author = {Aurbach, Maximilian and Spicka, Jan and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Evaluation of musculoskeletal modelling parameters of the shoulder complex during humeral abduction above 90°}, series = {Journal of Biomechanics}, volume = {106}, journal = {Journal of Biomechanics}, number = {June}, publisher = {Elsevier}, doi = {10.1016/j.jbiomech.2020.109817}, abstract = {Based on electromyographic data and force measurements within the shoulder joint, there is an indication that muscle and resulting joint reaction forces keep increasing over an abduction angle of 90°. In inverse dynamics models, no single parameter could be attributed to simulate this force behaviour accordingly. The aim of this work is to implement kinematic, kinetic and muscle model modifications to an existing model of the shoulder (AnyBody™) and assess their single and combined effects during abduction up to 140° humeral elevation. The kinematics and the EMG activity of 10 test subjects were measured during humeral abduction. Six modifications were implemented in the model: alternative wrapping of the virtual deltoid muscle elements, utilization of a three element Hill model, strength scaling, motion capture driven clavicle elevation/protraction, translation of the GH joint in dependency of the acting forces and an alteration of the scapula/clavicle rhythm. From the six modifications, 16 different combinations were considered. Parameter combinations with the Hill model changed the resultant GH joint reaction force and led to an increase in force during abduction of the humerus above 90°. Under the premise of muscle activities and forces within the GH joint rising after 90° of humeral abduction, we propose that the Hill type muscle model is a crucial parameter for accurately modelling the shoulder. Furthermore, the outcome of this study indicates that the Hill model induces the co-contraction of the muscles of the shoulder without the need of an additional stability criterion for an inverse dynamics approach.}, subject = {Schultergelenk}, language = {en} } @misc{AurbachSpickaSuessetal., author = {Aurbach, Maximilian and Spicka, Jan and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal modelling of the shoulder - effects on muscle recruitment and joint reaction force}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @misc{AurbachSuessDendorfer, author = {Aurbach, Maximilian and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {The impact of the hill type muscle model on the glenohumeral joint reaction force}, series = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, journal = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, language = {en} } @inproceedings{AurbachWagnerSuessetal., author = {Aurbach, Maximilian and Wagner, Kilian and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Implementation and Validation of Human Kinematics Measured Using IMUs for Musculoskeletal Simulations by the Evaluation of Joint Reaction Forces}, series = {CMBEBIH 2017, Proceedings of the International Conference on Medical and Biological Engineering 2017, Sarajevo, Bosnia and Herzegovina}, volume = {Vol. 62}, booktitle = {CMBEBIH 2017, Proceedings of the International Conference on Medical and Biological Engineering 2017, Sarajevo, Bosnia and Herzegovina}, editor = {Badnjevic, Almir}, publisher = {Springer}, address = {Singapore}, doi = {10.1007/978-981-10-4166-2_31}, pages = {205 -- 211}, abstract = {The gold standard for the analysis of human kinematics and kinetics is a camera-based motion capture system in combination with force measurement platforms. Alternatively, inertial measurement units can be utilized to obtain human kinematics, while ground reaction forces are computed from full body dynamics. This setup represents a system independent from the spatial confinement of a gait laboratory. The aim of this study is the comparison of the two methods by the investigation of lower limb kinematics and the resulting joint reaction forces within the ankle-, knee- and hip joints. For this purpose, human motion during gait was captured simultaneously by both measurement techniques. 13 trials from 8 different test subjects were evaluated in total. IMU data was processed with a quaternion based Kalman Filter. The data sets were implemented into a musculoskeletal simulation program in order to drive a virtual human body model. Each sensor was aligned to the gravitational and magnetic field vectors of the earth. The angles of flexions, extensions and rotations were analyzed to determine kinematic differences. Joint reaction forces defined kinetic dissimilarities. The overall kinematic differences of both models yielded root mean square errors of 7.62°, 6.02°, 4.95°, 2.79°, 2.38° and 3.56° for ankle flexion, subtalar eversion, knee flexion, hip external rotation, hip abduction and hip flexion, respectively. The proximo-distal differences in force peaks between the models yielded overall for the ankle, 57.33 \%Bodyweight(BW) ± 46.86 \%BW (16.66 \%(Maximum peak to peak) ± 13.62 \%) for the knee 37.09 \%BW ± 29.33 \%BW (17.65 \% ± 15.44 \%) and 32.03 \%BW ± 24.33 \%BW (15.6 \% ± 12.54 \%) for the hip. The overall outcome of this work investigated an approach independent of the common setup of the gait laboratory, thus enabling a cheaper and more flexible technology as an alternative. However, kinematic and thus kinetic differences remain rather large. Future work aims to improve the contact criterion for the calculation of the ground reaction forces and the implementation of a full-body calibration algorithm for the IMU system in order to counteract magnetic field disturbances.}, subject = {Bewegungsapparat}, language = {en} } @article{AurbachŠpičkaSuessetal., author = {Aurbach, Maximilian and Špička, Jan and S{\"u}ß, Franz and Vychytil, J. and Havelkov{\´a}, Leonard and Ryba, T. and Dendorfer, Sebastian}, title = {Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation}, series = {Journal of Biomechanics}, volume = {109}, journal = {Journal of Biomechanics}, number = {August}, publisher = {Elsevier}, doi = {10.1016/j.jbiomech.2020.109864}, abstract = {Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°-120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF. The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°-120° of abduction. Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach.}, language = {en} } @article{BenditzAuerSpoerreretal., author = {Benditz, Achim and Auer, Simon and Sp{\"o}rrer, J.F. and Wolkerstorfer, S. and Grifka, Joachim and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Regarding loads after spinal fusion, every level should be seen separately: a musculoskeletal analysis}, series = {European Spine Journal}, volume = {27}, journal = {European Spine Journal}, number = {8}, publisher = {Springer-Verlag}, doi = {10.1007/s00586-018-5476-5}, pages = {1905 -- 1910}, abstract = {The number of spinal fusion surgeries is steadily increasing and biomechanical consequences are still in debate. The aim of this study is to provide biomechanical insights into the sagittal balance of the spine and to compare spinal load before and after spinal fusion. METHOD: The joint reaction forces of 52 patients were analyzed in proximo-distal and antero-posterior direction from the levels T12-L1 to L5-S1 using musculoskeletal simulations. RESULTS: In 104 simulations, pre-surgical forces were equal to post-surgical. The levels L4-L5 and T12-L1, however, showed increased spinal forces compression forces with higher sagittal displacement. Improved restauration of sagittal balance was accompanied by lower spinal load. AP shear stress, interestingly decreased with sagittal imbalance. CONCLUSION: Imbalanced spines have a risk of increased compression forces at Th12-L1. L4-L5 always has increased spinal loads. These slides can be retrieved under Electronic Supplementary Material.}, subject = {Biomechanische Analyse}, language = {en} } @article{DePieriAtzoriFergusonetal., author = {De Pieri, Enrico and Atzori, Federica and Ferguson, Stephen J. and Dendorfer, Sebastian and Leunig, Michael and Aepli, Martin}, title = {Contact force path in total hip arthroplasty: effect of cup medialisation in a whole-body simulation}, series = {HIP International}, volume = {31}, journal = {HIP International}, number = {5}, publisher = {Sage}, doi = {10.1177/1120700020917321}, pages = {624 -- 631}, abstract = {Background: Cup medialisation down to the true acetabular floor in total hip arthroplasty with a compensatory femoral offset increase seems to be mechanically advantageous for the abductor muscles due to the relocation of the lever arms (body weight lever arm decreased, abductor lever arm increased). However, limited information is currently available about the effects of this reconstruction type at the head cup interface, compared to an anatomical reconstruction that maintains the natural lever arms. Through a whole-body simulation analysis, we compared medialised versus anatomical reconstruction in THA to analyse the effects on: (1) contact force magnitude at the head cup interface; (2) contact force path in the cup; and (3) abductor activity. Methods: Musculoskeletal simulations were performed to calculate the above-mentioned parameters using inverse dynamics analysis. The differences between the virtually implanted THAs were calculated to compare the medialised versus anatomical reconstruction. Results: Cup medialisation with compensatory femoral offset increase led to: (1) a reduction in contact force magnitude at the head cup interface up to 6.6\%; (2) a similar contact force path in the cup in terms of sliding distance and aspect ratio; and (3) a reduction in abductor activity up to 17.2\% (gluteus medius). Conclusions: In our opinion, these potential biomechanical gains do not generally justify a fully medialised reconstruction, especially in younger patients that are more likely to undergo revision surgery in their lifetime. Cup medialisation should be performed until sufficient press fit and bony coverage of a properly sized and oriented cup can be achieved.}, subject = {H{\"u}ftgelenkprothese}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {The effect of multifidus muscles atrophy following disc herniation on disc loading}, series = {Deutsche Gesellschaft f{\"u}r Biomechanik, Murnau, 2011}, booktitle = {Deutsche Gesellschaft f{\"u}r Biomechanik, Murnau, 2011}, language = {en} } @misc{Dendorfer, author = {Dendorfer, Sebastian}, title = {The influence of modeling parameters in the AnyBody Modeling System on muscle and joint loading in the shoulder}, series = {International Shoulder Group Meeting}, volume = {05}, journal = {International Shoulder Group Meeting}, language = {en} } @misc{Dendorfer, author = {Dendorfer, Sebastian}, title = {The influence of mental stress on the musculoskeletal system}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {Mechanobiology - Impact on regeneration and degradation}, series = {Translations in Regenerative Medicine, TIRM and FIFA Symposium, Regensburg, 2015}, booktitle = {Translations in Regenerative Medicine, TIRM and FIFA Symposium, Regensburg, 2015}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {How much iron to pump? The determination of muscle forces for activities of daily living}, series = {DGU, Berlin, 2008}, booktitle = {DGU, Berlin, 2008}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {Biomechanical evaluation and optimisation of countermeasure exercises}, series = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, booktitle = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, language = {en} } @inproceedings{DendorferCarbesRasmussen, author = {Dendorfer, Sebastian and Carbes, S. and Rasmussen, John}, title = {The influence of muscle forces on biomechanical fracture fixation simulations - from in-vivo forces to tissue strains}, series = {World Congress on Medical Physics and Biomedical Engineering, 7 - 12, 2009, Munich}, booktitle = {World Congress on Medical Physics and Biomedical Engineering, 7 - 12, 2009, Munich}, language = {en} } @inproceedings{DendorferEnglert, author = {Dendorfer, Sebastian and Englert, Carsten}, title = {Forces on a clavicles midshaft fracture and influence of fracture type}, series = {AO Symposium, Regensburg, 2009}, booktitle = {AO Symposium, Regensburg, 2009}, language = {en} } @inproceedings{DendorferFeldottoWalchetal., author = {Dendorfer, Sebastian and Feldotto, Benedikt and Walch, Blasius and Koch, Patrick and Knoll, Alois}, title = {Co-Development of an Infant Prototype in Hardware and Simulation based on CT Imaging Data}, series = {IEEE International Conference on Cyborg and Bionic Systems (CBS), 2019, Munich}, booktitle = {IEEE International Conference on Cyborg and Bionic Systems (CBS), 2019, Munich}, pages = {6}, abstract = {The development of biomimetic robots has gained research interest in the last years as it may both help under-standing processes of motion execution in biological systems as well as developping a novel generation of intelligent and energy efficient robots. However, exact model generation that builds up on observations and robot design is very time intensive. In this paper we present a novel pipeline for co-development of biomimetic hardware and simulation models based on biological Computer Tomography (CT) data. For this purpose we exploit State of the Art rapid prototyping technologies such as 3D Printing and the Neurorobotics Platform for musculoskeletal simulations in virtual environments. The co-development integrates both advantages of virtual and physical experimental models and is expected to increase development speed of controllers that can be tested on the simulated counterpart before application to a printed robot model. We demonstrate the pipeline by generating a one year old infant model as a musculoskeletal simulation model and a print-in-place 3D printed skeleton as a single movable part. Even though we hereonly introduce the initial body generation and only a first testsetup for a modular sensory and control framework, we can clearly spot advantages in terms of rapid model generation and highly biological related models. Engineering costs are reducedand models can be provided to a wide research community for controller testing in an early development phase.}, subject = {Biomechanische Analyse}, language = {en} } @article{DendorferHammerLenich, author = {Dendorfer, Sebastian and Hammer, Joachim and Lenich, Andreas}, title = {Characterisation and testing of biomaterials}, series = {Technology and Health Care}, volume = {19}, journal = {Technology and Health Care}, number = {5}, doi = {10.3233/THC-2011-0644}, pages = {357 -- 371}, subject = {Biomaterial}, language = {en} } @incollection{DendorferHammerLenich, author = {Dendorfer, Sebastian and Hammer, Joachim and Lenich, Andreas}, title = {Characterisation and testing of biomaterials}, series = {Basic Engineering for Medics and Biologists: An ESEM Primer}, booktitle = {Basic Engineering for Medics and Biologists: An ESEM Primer}, number = {Chapter IV.4.}, editor = {Lee, T. Clive and Niederer, Peter F.}, publisher = {Non Basic Stock Line}, isbn = {978-1607505266}, subject = {Biomaterial}, language = {en} } @inproceedings{DendorferKubowitsch, author = {Dendorfer, Sebastian and Kubowitsch, Simone}, title = {The interaction of mental stress and biomechanics}, series = {Health Technology Triangle, Weiden, 2016}, booktitle = {Health Technology Triangle, Weiden, 2016}, language = {en} } @inproceedings{DendorferKubowitschSuess, author = {Dendorfer, Sebastian and Kubowitsch, Simone and S{\"u}ß, Franz}, title = {How to determine the effect of working conditions on the human body}, series = {11th International Scientific Conference on Production Engineering DEVELOPMENT AND MODERNIZATION OF PRODUCTION (RIM 2017), Sarajevo, Bosnia and Herzegovina}, booktitle = {11th International Scientific Conference on Production Engineering DEVELOPMENT AND MODERNIZATION OF PRODUCTION (RIM 2017), Sarajevo, Bosnia and Herzegovina}, abstract = {Work places and conditions strains the human body, both psychologically and biomechanically. In order to analyse working conditions and in the following to improve them, detailed knowledge about the effect of the different stressors on the body is needed. This manuscript discusses methods on how to evaluate biomechanical and mental loading and its effect on the musculoskeletal system. A possible workflow for the analysis is presented.}, subject = {Arbeitsbedingungen}, language = {en} } @article{DendorferMaierHammer, author = {Dendorfer, Sebastian and Maier, Hans J{\"u}rgen and Hammer, Josef}, title = {Fatigue damage in cancellous bone: an experimental approach from continuum to micro scale}, series = {Journal of the Mechanical Behavior of Biomedical Materials}, volume = {2}, journal = {Journal of the Mechanical Behavior of Biomedical Materials}, number = {1}, doi = {10.1016/j.jmbbm.2008.03.003}, pages = {113 -- 119}, abstract = {Repeated loadings may cause fatigue fractures in bony structures. Even if these failure types are known, data for trabecular bone exposed to cyclic loading are still insufficient as the majority of fatigue analyses on bone concentrate on cortical structures. Despite its highly anisotropic and inhomogeneous structure, trabecular bone is treated with continuum approaches in fatigue analyses. The underlying deformation and damage mechanism within trabecular specimens are not yet sufficiently investigated. In the present study different types of trabecular bone were loaded in monotonic and cyclic compression. In addition to the measurement of integral specimen deformations, optical deformation analysis was employed in order to obtain strain distributions at different scale levels, from the specimens' surface to the trabeculae level. These measurements allowed for the possibility of linking the macroscopic and microscopic mechanical behaviour of cancellous bone. Deformations were found to be highly inhomogeneous across the specimen. Furthermore strains were found to already localise at very low load levels and after few load cycles. Microcracks in individual trabeculae were induced in the very early stage of cyclic testing. The results provide evidence of the capability of the method to supply essential data on the failure behaviour of individual trabeculae in future studies.}, subject = {Knochen}, language = {en} } @incollection{DendorferMaierHammer, author = {Dendorfer, Sebastian and Maier, Hans J{\"u}rgen and Hammer, Josef}, title = {How do age and anisotropy affect the fatigue behaviour of cancellous bone?}, series = {Medicine Meets Engineering}, booktitle = {Medicine Meets Engineering}, publisher = {IOS Press}, pages = {68 -- 74}, abstract = {The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions not aligned with the main physiological axis remains unclear. Furthermore age effects on the fatigue behaviour are not well described. In the present study, different groups of human vertebral cancellous bone were exposed to cyclic compression. The inital modulus and therefore lifetimes were found to be highly dependent on age. The decrease in both with increasing age was much more pronounced in specimens which were not aligned with the main physiological axis. This implies that old bone is much more sensitive to (cyclic) failure loads in general but particularly to loads which are not coincident with the physiological main axis.}, subject = {Knochenbruch}, language = {en} } @article{DendorferMaierTayloretal., author = {Dendorfer, Sebastian and Maier, Hans J{\"u}rgen and Taylor, David and Hammer, Joachim}, title = {Anisotropy of the fatigue behaviour of cancellous bone}, series = {Journal of Biomechanics}, volume = {41}, journal = {Journal of Biomechanics}, number = {3}, doi = {10.1016/j.jbiomech.2007.09.037}, pages = {636 -- 641}, abstract = {The fatigue behaviour of materials is of particular interest for the failure prediction of materials and structures exposed to cyclic loading. For trabecular bone structures only a few sets of lifetime data have been reported in the literature and structural measures are commonly not considered. The influence of load contributions which are not aligned with the main physiological axis remains unclear. Furthermore site and species dependent relationships are not well described. In this study five different groups of trabecular bone, defined in terms of orientation, species and site were exposed to cyclic compression. In total, 108 fatigue tests were analysed. The lifetimes were found to decrease drastically when off-axis loads were applied. Additionally, species and site strongly affect fatigue lifetimes. Strains at failure were also found to be a function of orientation.}, subject = {Erm{\"u}dung}, language = {en} } @inproceedings{DendorferRasmussen, author = {Dendorfer, Sebastian and Rasmussen, John}, title = {The influence of in-vivo muscle forces on the stress distribution in a vertebral body during activities of daily living}, series = {Eurospine Warsaw, Poland 2009}, booktitle = {Eurospine Warsaw, Poland 2009}, language = {en} } @inproceedings{DendorferRasmussenChristensenetal., author = {Dendorfer, Sebastian and Rasmussen, John and Christensen, Soeren Toerholm and Robie, Bruce}, title = {The Effect of Spinal Disc Herniation on Multifidus Muscles}, series = {56th Orthopaedic Research Society Meeting, New Orleans, USA, 2010}, booktitle = {56th Orthopaedic Research Society Meeting, New Orleans, USA, 2010}, language = {en} } @article{DendorferWeberKennedy, author = {Dendorfer, Sebastian and Weber, Tim and Kennedy, O.}, title = {Musculoskeletal modeling for hip replacement outcome analyses and other applications}, series = {The Journal of the American Academy of Orthopaedic Surgeons}, volume = {22}, journal = {The Journal of the American Academy of Orthopaedic Surgeons}, number = {4}, doi = {10.5435/JAAOS-22-04-268}, pages = {268 -- 269}, subject = {H{\"u}ftgelenkprothese}, language = {en} } @misc{EgerBergstraesserDendorferetal., author = {Eger, Maximilian and Bergstraesser, Marcel and Dendorfer, Sebastian and Lenich, Andreas and Pfeifer, Christian}, title = {Influence of radial head prosthetic design on humeroradial stability: Validation of a test rig therefore}, series = {DOKU2022, Deutscher Kongress f{\"u}r Orthop{\"a}die und Unfallchirurgie, 25.-28. 10.2022, Berlin}, journal = {DOKU2022, Deutscher Kongress f{\"u}r Orthop{\"a}die und Unfallchirurgie, 25.-28. 10.2022, Berlin}, publisher = {German Medical Science GMS Publishing House}, address = {D{\"u}sseldorf}, doi = {10.3205/22dkou611}, url = {http://nbn-resolving.de/urn:nbn:de:0183-22dkou6115}, language = {en} } @article{EngelhardtMelznerHavelkovaetal., author = {Engelhardt, Lucas and Melzner, Maximilian and Havelkova, Linda and Fiala, Pavel and Christen, Patrik and Dendorfer, Sebastian and Simon, Ulrich}, title = {A new musculoskeletal AnyBodyTM detailed hand model}, series = {Computer Methods in Biomechanics and Biomedical Engineering}, volume = {24}, journal = {Computer Methods in Biomechanics and Biomedical Engineering}, number = {7}, publisher = {Taylor \& Francis}, doi = {10.1080/10255842.2020.1851367}, pages = {777 -- 787}, abstract = {Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role.}, language = {en} } @misc{EngelhardtMelznerHavelkovaetal., author = {Engelhardt, Lucas and Melzner, Maximilian and Havelkova, Linda and Fiala, Pavel and Rybarova, Martina and Christen, Patrik and Dendorfer, Sebastian and Simon, Ulrich}, title = {A new musculoskeletal AnyBody detailed hand model}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, abstract = {The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.}, language = {en} } @article{EnglertAngeleFierlbecketal., author = {Englert, Carsten and Angele, Peter and Fierlbeck, J. and Dendorfer, Sebastian and Schubert, T. and M{\"u}ller, R. and Lienhard, S. and Zellner, J. and Nerlich, Michael and Neumann, Carsten}, title = {Conductive bone substitute material with variable antibiotic delivery}, series = {Der Unfallchirurg}, volume = {110}, journal = {Der Unfallchirurg}, number = {5}, publisher = {Springer}, doi = {10.1007/s00113-007-1229-3}, pages = {408 -- 413}, abstract = {A new bone substitute, consisting of hydroxylapatite and calcium sulphate, was prepared in two formulations and analysed for its mechanical strength and antibiotic elution.The bone substitute PerOssal has osteoconductive and degradable properties. The material has a built-in capillary structure, which results in an immediate fluid uptake. Antibiotics absorbed to the bone substitute resulted in a prolonged release rate. Mechanical strength was investigated by an unconfined compression test up to failure under both wet and dry conditions for both formulations of the bone substitute. Antibiotic release was analysed microbiologically for two antibiotics, vancomycin and gentamicin, over an elution period of 10 days using the agar diffusion method.The drug release analysis resulted in a prolonged release rate of both antibiotics over 10 days. In vitro the amount of gentamicin and vancomycin eluted at day 10. From one pellet still exceeded the minimal inhibitory concentration of most aetiologically important pathogens. Formulation two of the present bone substitute is significantly harder in both wet and dry conditions when compared to formulation one. Both formulations lose strength in the wet condition relative to their performance in the dry condition. However, formulation two is as hard under wet conditions as formulation one is when dry.PerOssal is a suitable new degradable osteoconductive bone substitute that can be loaded with antibiotic solutions, which are released in effective doses over 10 days. The mechanical strength of PerOssal is sufficient to support cancellous bone defects in non-weight-bearing areas or in combination with osteosynthesis.}, subject = {Knochenersatz}, language = {en} } @unpublished{FoerstlAdlerSuessetal., author = {F{\"o}rstl, Nikolas and Adler, Ina and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Technologies for Evaluation of Pelvic Floor Functionality: A Systematic Review}, publisher = {Center for Open Science}, doi = {10.31219/osf.io/dcqyg}, abstract = {Pelvic floor dysfunction is a common problem in women and has a negative impact ontheir quality of life. The aim of this review was to provide a general overview of the current state oftechnology used to assess pelvic floor functionality. It also provides literature research of the phys-iological and anatomical factors that correlate with pelvic floor health. The systematic review wasconducted according to the PRISMA guidelines. PubMed, ScienceDirect, Cochrane Library andIEEE databases were searched for publications on sensor technology for the assessment of pelvicfloor functionality. Anatomical and physiological parameters were identified through a manualsearch. In the systematic review 115 publications were included. 12 different sensor technologieswere identified. Information on the obtained parameters, sensor position, test activities and subjectcharacteristics were prepared in tabular form from each publication. 16 anatomical and physiologi- cal parameters influencing pelvic floor health were identified in 17 published studies and rankedfor their statistical significance. Taken together, this review could serve as a basis for the develop-ment of novel sensors which could allow for quantifiable prevention and diagnosis, as well as par-ticularized documentation of rehabilitation processes related to pelvic floor dysfunctions.}, language = {en} } @article{FoerstlAdlerSuessetal., author = {F{\"o}rstl, Nikolas and Adler, Ina and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Technologies for Evaluation of Pelvic Floor Functionality: A Systematic Review}, series = {Sensors}, volume = {24}, journal = {Sensors}, number = {12}, publisher = {MDPI}, doi = {10.3390/s24124001}, abstract = {Pelvic floor dysfunction is a common problem in women and has a negative impact on their quality of life. The aim of this review was to provide a general overview of the current state of technology used to assess pelvic floor functionality. It also provides literature research of the physiological and anatomical factors that correlate with pelvic floor health. This systematic review was conducted according to the PRISMA guidelines. The PubMed, ScienceDirect, Cochrane Library, and IEEE databases were searched for publications on sensor technology for the assessment of pelvic floor functionality. Anatomical and physiological parameters were identified through a manual search. In the systematic review, 114 publications were included. Twelve different sensor technologies were identified. Information on the obtained parameters, sensor position, test activities, and subject characteristics was prepared in tabular form from each publication. A total of 16 anatomical and physiological parameters influencing pelvic floor health were identified in 17 published studies and ranked for their statistical significance. Taken together, this review could serve as a basis for the development of novel sensors which could allow for quantifiable prevention and diagnosis, as well as particularized documentation of rehabilitation processes related to pelvic floor dysfunctions.}, language = {en} } @article{FoerstlSuessEnglertetal., author = {F{\"o}rstl, Nikolas and S{\"u}ß, Franz and Englert, Carsten and Dendorfer, Sebastian}, title = {Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning}, series = {Medical Engineering \& Physics}, volume = {121}, journal = {Medical Engineering \& Physics}, edition = {Journal Pre-proof}, publisher = {Elsevier}, doi = {10.1016/j.medengphy.2023.104059}, pages = {22}, abstract = {To avoid dislocation of the shoulder joint after reverse total shoulder arthroplasty, it is important to achieve sufficient shoulder stability when placing the implant components during surgery. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this research was to develop a temporary reverse shoulder implant prototype that would allow intraoperative measurement of shoulder stiffness while varying the position of the implant components. Joint angle and torque measurement techniques were developed to determine shoulder stiffness. Hall sensors were used to measure the joint angles by converting the magnetic flux densities into angles. The accuracy of the joint angle measurements was tested using a test bench. Torques were determined by using thin-film pressure sensors. Various mechanical mechanisms for variable positioning of the implant components were integrated into the prototype. The results of the joint angle measurements showed measurement errors of less than 5° in a deflection range of ±15° adduction/abduction combined with ±45° flexion/extension. The proposed design provides a first approach for intra-operative assessment of shoulder stiffness. The findings can be used as a technological basis for further developments.}, language = {en} } @inproceedings{GalibarovAlMunajjedDendorferetal., author = {Galibarov, Pavel E. and Al-Munajjed, Amir Andreas and Dendorfer, Sebastian and Christensen, Soeren Toerholm and Rasmussen, John}, title = {The effect of varying the stiffness of spinal fusion devices on the adjacent levels using multibody dynamics simulation}, series = {Orthopaedic Proceedings}, volume = {94-B}, booktitle = {Orthopaedic Proceedings}, number = {SUPP_XL01 Sep 2012}, pages = {2}, abstract = {INTRODUCTION Several clinical studies demonstrated long-term adjacent-level effects after implantation of spinal fusion devices[1]. These effects have been reported as adjacent joint degeneration and the development of new symptoms correlating with adjacent segment degeneration[2] and the trend has therefore gone to motion preservation devices; however, these effects have not been understood very well and have not been investigated thoroughly[3]. The aim of this study is to investigate the effect of varying the stiffness of spinal fusion devices on the adjacent vertebral levels. Disc forces, moments and facet joint forces were analyzed. METHODS The AnyBody Modeling System was used to compute the in-vivo muscle and joint reaction forces of a musculoskeletal model. The full body model used in this study consists of 188 muscle fascicles in the lumbar spine and more than 1000 individual muscle branches in total. The model has been proposed by de Zee et al.[3], validated by Rasmussen et al.[4] and by Galibarov et al.[5]. The new model[5] determines the individual motions between vertebrae based on the equilibrium between forces acting on the vertebrae from muscles and joints and the passive stiffness in disks and ligaments, figure 1a. An adult of 1.75 m and 75 kg with a spinal implant in L4L5 was modeled. This model was subjected to a flexion-extension motion using different elastic moduli to analyze and compare to a non-implanted scenario. The analyzed variables were vertebral motion, the disc reaction forces and moments, as well as facet joint forces in the treated and the adjacent levels: L2L3, L3L4, L4L5 and L5-Sacrum. RESULTS When introducing a spinal fusion device in the L4L5 joint the reaction forces and moments decreased in this joint with stiffer devices leading to lower joint loads. However, in the adjacent joints, L3L4 and L5Sacrum, an increase was observed when implanting stiffer devices. Similar trends could be found for the L2L3 joint. The loads in the facet joints showed the same trends. While introducing a spinal fusion device reduced the facet joint forces in the treated joint, the loads in the adjacent facet joints were increased according to the stiffness of the implanted device, figure 1b. DISCUSSION While the treated disc joint showed reduced motion and loads, the adjacent levels demonstrated a significant increase. In particular, the increased facet joint forces in the adjacent levels can lead to adjacent level facet pain or accelerated facet joint degeneration. Introducing a device resulted in preventing facet contact and therefore facet joint loads, even using the device with the lowest stiffness. CONCLUSION The presented model shows that clinical complications such as facet joint degeneration in adjacent levels after implantation of spinal fusion device are consistent with the change in the mechanical-stimulus distribution in the system.}, language = {en} } @inproceedings{GalibarovDendorferChristensen, author = {Galibarov, Pavel E. and Dendorfer, Sebastian and Christensen, Soeren Toerholm}, title = {On modelling spine curvature dependent on muscular and external forces in multibody dynamics system}, series = {International Society of Biomechanics (ISB), 13th congress, 2011, Brussels, Belgium}, booktitle = {International Society of Biomechanics (ISB), 13th congress, 2011, Brussels, Belgium}, pages = {2}, abstract = {This paper presents a computational approach for investigating effect of muscular and external forces on curvature of the lumbar spine. Multibody dynamics system is used to compute the lumbar spine curvature using a force-dependent kinematics facility, e.g. this method allows releasing some degrees of freedom in order to be computed based on the current load configuration.}, language = {en} } @inproceedings{GalibarovDendorferRasmussen, author = {Galibarov, Pavel E. and Dendorfer, Sebastian and Rasmussen, John}, title = {Two Computational Models of the Lumbar Spine:}, series = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA, vol. Marie Curie Initial Training Network "SpineFX"}, booktitle = {Proceedings of the 2011 ORS Annual Meeting, Long Beach, CA, vol. Marie Curie Initial Training Network "SpineFX"}, language = {en} } @inproceedings{GrossSuessVerkerkeetal., author = {Gross, Simon and S{\"u}ß, Franz and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Simulating fatigue in musculoskeletal models using surface electromyography, ECCOMAS Congress, Crete, Greece, 201}, series = {ECCOMAS Congress, Crete, Greece, 2016}, booktitle = {ECCOMAS Congress, Crete, Greece, 2016}, language = {en} } @inproceedings{GrossVerkerkeDendorfer, author = {Gross, Simon and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Combined Experimental and Numerical Approach to Investigate Changes in Muscle Recruitment Pattern of the Back Muscles during Exhausting Exercise}, series = {World Congress Biomechanics Dublin, 2018}, booktitle = {World Congress Biomechanics Dublin, 2018}, abstract = {In recent years, musculoskeletal computation has become a widely used tool to investigate joint and muscle forces within the human body. However, the issue of muscle fatigue is not considered adequately in most models and is a challenging task. One aspect that needs to be examined is the interaction of muscles during an exhausting task. Therefore, an experimental study was designed to analyze the changes of back muscle recruitment pattern during such exercises. In this study 38 subjects (27 male, 11 female, height = 177±8.5 cm, weight = 74.0±13.6 kg) participated. Each subject had to perform three static and three dynamic exhausting exercises where the back muscles were loaded with subject specific forces using a dynamometer adapter especially designed for the trunk muscles. To collect the muscle activity, twelve surface electromyography sensors were applied on the back, and four on the abdominal muscles. Muscle activity and fatigue were analyzed by calculating the maximum voluntary contraction normalized signal and the median frequency. At first the fatigue of m. erector spinae and m. multifidi was analyzed, since these muscles carry the main load during the exercises. Subsequently the activity of the m. trapezius, m. rectus abdominis and m. obliquus externus were investigated to determine recruitment patterns. To gain more detailed information of these patterns a numerical model was built using the AnyBody Modeling System™. Analyzing the measurements, we can observe an increasing muscle activity during isokinetic exercises while the force is constant. Since the activity in the simulation is defined as the current force output divided by the strength of the muscle, the strength parameter was scaled down based on the measured data, assuming a linear force - activity correlation, and using a numerical algorithm considering the influence of cross talk. The results show, that changes in recruitment pattern can be divided into three major subgroups. Prior to total exhaustion, some of the subjects show additional activation of muscles in the trapezius region, while other subjects show an additional activation of abdominal muscles, increasing the intra-abdominal pressure which supports the spine. In the third group an activation in both regions can be observed. The numerical simulations show an increasing activity of abdominal muscles as well as muscles in the upper back. Especially the m. latissimus dorsi shows a significantly higher activity. The results lead to the conclusion that prior to total exhaustion, additional muscles are recruited to support the main muscles. It was shown that abdominal muscles are activated to support back muscles by pressurizing the trunk cavity to delay total exhaustion as long as possible. In conclusion, the results show that changes in muscle recruitment pattern need to be considered when introducing muscle fatigue to musculoskeletal models.}, language = {en} } @inproceedings{GrossVerkerkeDendorfer, author = {Gross, Simon and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {Investigation of external load dependent static and dynamic muscle fatigue}, series = {23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017}, booktitle = {23th Congress of the European Society of Biomechanics, Sevilla, Spain, 2017}, language = {en} }