@misc{AuerReinkerSuessetal., author = {Auer, Simon and Reinker, Lukas and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Comparing calculated and measured muscle activity of thigh muscles in dynamic motion.}, series = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, journal = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, pages = {640}, language = {en} } @misc{MelznerPfeiferSuessetal., author = {Melzner, Maximilian and Pfeifer, Christian and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Muskuloskeletal analysis of elbow stability for common injury patterns}, series = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, journal = {27th Congress of the European Society of Biomechanics, 26 - 29 June 2022, Porto, Portugal}, pages = {654}, language = {en} } @misc{KoeglerIsmailRusavyetal., author = {K{\"o}gler, Michael and Ismail, Khaled M. and Rusavy, Zdenek and Kalis, Vladimir and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Influence of bed height and stance on accoucheurs lower back and glenohumeral load during simulated childbirth}, series = {31st meeting of Czech Urogynaecological Society, Prague, 2022}, journal = {31st meeting of Czech Urogynaecological Society, Prague, 2022}, language = {en} } @misc{FoerstlSuessEnglertetal., author = {F{\"o}rstl, Nikolas and S{\"u}ß, Franz and Englert, Carsten and Dendorfer, Sebastian}, title = {Design of a reverse shoulder implant to measure shoulder stiffness during implant component positioning}, series = {Book of abstracts / ESB 2023, 28th Congress of the European Society of Biomechanics, 9-12 July 2023, Maastricht, The Netherlands.}, journal = {Book of abstracts / ESB 2023, 28th Congress of the European Society of Biomechanics, 9-12 July 2023, Maastricht, The Netherlands.}, abstract = {Introduction Dislocation of the shoulder joint is one of the more common complications after reverse total shoulder arthroplasty [1], which is often associated with malposition of the prosthetic components [2]. Therefore, achieving sufficient shoulder stability should not be neglected when positioning the implant components. One parameter for assessing shoulder stability can be shoulder stiffness. The aim of this work is to develop a reverse shoulder implant prototype that allows intraoperative measurement of shoulder stiffness while varying the position of the implant components. The measured stiffness could provide a quantitative statement regarding the optimal positioning of the implant components, which can be adjusted accordingly in the final reverse shoulder prosthesis. Methods To measure the stiffness of the shoulder joint, it is necessary to record the joint angles and the torques generated during movement. The changes in the rotation angles were measured using 3D hall sensors and magnets. The magnets were placed under the humerosocket, and the hall sensors were integrated into the glenosphere. The strength of the magnetic field was used to determine the position of the humerosocket in relation to the glenosphere. The accuracies of the angle measurements were tested using a test bench. Three thin film pressure sensors were used to record forces at different points under the humerosocket. To obtain a force value from the sensor signal, the sensors were calibrated using a load cell. The variation of the implant components positions was integrated into the prototype implant through different constructive mechanisms to adjust the stiffness of the shoulder joint. Results In the range of ±45° flexion/extension combined with ±15° adduction/abduction, the joint position could be determined with sufficient accuracy (error e ≤ 5°). The areas near the combined maximum deflections of ±45° flexion/extension and ±45° adduction/abduction indicate the greatest deviation from the target angle. The force values of the thin film sensors enable the calculation of moments around two axes. As variable component position parameters, the tray offset, the neck-shaft angle and the humerus version were integrated into the implant prototype. Discussion Ideally, the accuracy of the angle measurements should only depend on the amount of deflection and not on the direction of deflection. The asymmetric behavior indicates a deviation from the correct positioning of the hall sensors. The application of a calibration matrix could compensate for the measurement errors and could demonstrate the potential of the new method for joint angle measurements. The accuracy of the torque measurements and the functionality of the mechanical arresting mechanisms must be investigated in further studies. Overall, the developed measurement method can help to avoid malpositioning of the implant components in reverse total shoulder arthroplasty. References 1. Clark et al, J Shoulder and elbow surgery, 21:36-41 2012. 2. Randelli et al, J Musculoskeletal surgery, 98:15-18, 2014.}, language = {en} } @misc{GschossmannSuessDendorfer, author = {Gschoßmann, Lukas and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Impact of Model Parameters on Ground Reaction Force Predictions in Musculoskeletal Modelling}, series = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July, Stockholm}, journal = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July, Stockholm}, abstract = {This study evaluated how model parameters affect ground reaction force (GRF) predictions in musculoskeletal simulations. A parameter study varying contact height and velocity thresholds and marker weights was conducted. While height and velocity thresholds had minimal impact, marker weights impact prediction errors. These findings highlight the importance of carefully selecting model parameters.}, language = {en} } @misc{AdlerFoerstlČechovaetal., author = {Adler, Ina and F{\"o}rstl, Nikolas and Čechov{\´a}, Hana and Nov{\´a}ček, V{\´i}t and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Mechanistic analysis of pelvic floor functionality using musculoskeletal simulation}, series = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July 2025, Stockholm}, journal = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27-31 July 2025, Stockholm}, doi = {10.35096/othr/pub-8729}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-87294}, pages = {1}, abstract = {There is consensus that knowledge about the fundamentals of the pelvic floor remains incomplete, particularly regarding the sensitivity of individual pelvic floor muscles to posture variations. This study aimed to investigate the effects of variations in pelvic tilt and the point of force application induced by changes in posture on pelvic floor activity using musculoskeletal simulation. A parameter study analysed various loading cases, highlighting the coherent response of individual pelvic floor muscles to loads. Muscle activities and forces were compared across different force application points and pelvic tilt angles. A key finding was identifying peak muscle activity conditions that could help better understand the causes of pelvic floor disorders.}, language = {en} } @misc{GschossmannSchedelSuessetal., author = {Gschoßmann, Lukas and Schedel, Valentin and S{\"u}ß, Franz and Weber, Markus and Pfingsten, Andrea and Dendorfer, Sebastian}, title = {Evaluating Knee Joint Loads Across Exercises and Activities of Daily Living to Personalize TKA Rehabilitation}, series = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27.-31. July 2025, Stockholm}, journal = {ISB 2025 - The XXX Congress of the International Society of Biomechanics, 27.-31. July 2025, Stockholm}, doi = {10.35096/othr/pub-8725}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-87252}, pages = {1}, abstract = {This study assessed knee joint loading during various physiotherapy exercises and activities of daily living in 30 healthy subjects. Results showed that lunges and squats caused the highest joint forces, while gait and stair activities also imposed substantial loads. These findings support datadriven exercise selection for personalized rehabilitation after total knee arthroplasty.}, language = {en} }