@article{WeberDendorferGrifkaetal., author = {Weber, Tim A. and Dendorfer, Sebastian and Grifka, Joachim and Verkerke, Gijsbertus Jacob and Renkawitz, Tobias}, title = {Does Computer-Assisted Femur First THR Improve Musculoskeletal Loading Conditions?}, series = {BioMed Research International}, volume = {2015}, journal = {BioMed Research International}, editor = {Takagi, Michiaki}, doi = {10.1155/2015/625317}, pages = {ID 625317}, abstract = {We have developed a novel, computer-assisted operation method for minimal-invasive total hip replacement (THR) following the concept of "femur first/combined anteversion," which incorporates various aspects of performing a functional optimization of the prosthetic stem and cup position (CAS FF). The purpose of this study is to assess whether the hip joint reaction forces and patient's gait parameters are being improved by CAS FF in relation to conventional THR (CON). We enrolled 60 patients (28 CAS FF/32 CON) and invited them for gait analysis at three time points (preoperatively, postop six months, and postop 12 months). Data retrieved from gait analysis was processed using patient-specific musculoskeletal models. The target parameters were hip reaction force magnitude (hrf), symmetries, and orientation with respect to the cup. Hrf in the CAS FF group were closer to a young healthy normal. Phase-shift symmetry showed an increase in the CAS FF group. Hrf orientation in the CAS FF group was closer to optimum, though no edge or rim-loading occurred in the CON group as well. The CAS FF group showed an improved hrf orientation in an early stage and a trend to an improved long-term outcome.}, subject = {H{\"u}ftgelenkprothese}, language = {en} } @article{PfeiferMuellerPrantletal., author = {Pfeifer, Christian and M{\"u}ller, Michael and Prantl, Lukas and Berner, Arne and Dendorfer, Sebastian and Englert, Carsten}, title = {Cartilage labelling for mechanical testing in T-peel configuration}, series = {International Orthopaedics}, volume = {36}, journal = {International Orthopaedics}, number = {7}, publisher = {Springer}, doi = {10.1007/s00264-011-1468-3}, pages = {1493 -- 1499}, abstract = {PURPOSE: The purpose of this study was to find a suitable method of labelling cartilage samples for the measurement of distraction distances in biomechanical testing. METHODS: Samples of bovine cartilage were labelled using five different methods: hydroquinone and silver nitrate (AgNO3), potassium permanganate (KMnO4) with sodium thiosulphate (Na2S2O3), India ink, heat, and laser energy. After the labelling, we analysed the cartilage samples with regard to cytotoxity by histochemical staining with ethidiumbromide homodimer (EthD-1) and calcein AM. Furthermore, we tested cartilages labelled with India ink and heat in a T-peel test configuration to analyse possible changes in the mechanical behaviour between marked and unlabelled samples. RESULTS: Only the labelling methods with Indian ink or a heated needle showed acceptable results in the cytotoxity test with regard to labelling persistence, accuracy, and the influence on consistency and viability of the chondrocytes. In the biomechanical T-peel configuration, heat-labelled samples collapsed significantly earlier than unlabelled samples. CONCLUSION: Labelling bovine cartilage samples with Indian ink in biomechanical testing is a reliable, accurate, inexpensive, and easy-to-perform method. This labelling method influenced neither the biomechanical behaviour nor the viability of the tissue compared to untreated bovine cartilage.}, subject = {Knorpel}, language = {en} } @article{WongRasmussenSimonsenetal., author = {Wong, Christian and Rasmussen, John and Simonsen, Erik B. and Hansen, Lone and de Zee, Mark and Dendorfer, Sebastian}, title = {The Influence of Muscle Forces on the Stress Distribution in the Lumbar Spine}, series = {The Open Spine Journal}, volume = {3}, journal = {The Open Spine Journal}, number = {1}, doi = {10.2174/1876532701103010021}, pages = {21 -- 26}, abstract = {Introduction: Previous studies of bone stresses in the human lumbar spine have relied on simplified models when modeling the spinal musculature, even though muscle forces are likely major contributors to the stresses in the vertebral bones. Detailed musculoskeletal spine models have recently become available and show good correlation with experimental findings. A combined inverse dynamics and finite element analysis study was conducted in the lumbar spine to investigate the effects of muscle forces on a detailed musculoskeletal finite element model of the 4th lumbar vertebral body. Materials and Methodology: The muscle forces were computed with a detailed and validated inverse dynamics musculoskeletal spine model in a lifting situation, and were then applied to an orthotropic finite element model of the 4th lumbar vertebra. The results were compared with those from a simplified load case without muscles. Results: In general the von Mises stress was larger by 30\%, and even higher when looking at the von Mises stress distribution in the superio-anterior and central part of the vertebral body and in the pedicles. Conclusion: The application of spine muscles to a finite element model showed markedly larger von Mises stress responses in the central and anterior part of the vertebral body, which can be tolerated in the young and healthy spine, but it would increase the risk of compression fractures in the elderly, osteoporotic spine.}, subject = {Lendenwirbels{\"a}ule}, language = {en} } @article{RoldanMoralisDendorferetal., author = {Rold{\´a}n, J.C. and Moralis, A. and Dendorfer, Sebastian and Witte, J. and Reicheneder, C.}, title = {Controlled central advancement of the midface after Le Fort III osteotomy by a 3-point skeletal anchorage}, series = {The Journal of craniofacial surgery}, volume = {22}, journal = {The Journal of craniofacial surgery}, number = {6}, doi = {10.1097/SCS.0b013e318231fc8d}, pages = {2384 -- 2386}, abstract = {A 3-point skeletal anchorage with taping screws for distraction osteogenesis after a Le Fort III osteotomy was applied for the first time in a severely mentally impaired patient where intraoral devices had to be avoided. All 3-force application points included the center of resistance, which allowed an optimal control on the resulting moment. A novel device for skeletal long-term retention into the nasal dorsum prevented a relapse, whereas adjustment of the midface position was observed. Fusioned three-dimensional computed tomography analysis revealed real movements not accessible by a conventional cephalometry.}, subject = {Mund-Kiefer-Gesichts-Chirurgie}, language = {en} } @article{ReinkerBlaesingBierletal., author = {Reinker, Lukas and Bl{\"a}sing, Dominic and Bierl, Rudolf and Ulbricht, Sabina and Dendorfer, Sebastian}, title = {Correlation of Acceleration Curves in Gravitational Direction for Different Body Segments during High-Impact Jumping Exercises}, series = {sensors}, volume = {23}, journal = {sensors}, number = {4}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/s23042276}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-58217}, abstract = {Osteoporosis is a common disease of old age. However, in many cases, it can be very well prevented and counteracted with physical activity, especially high-impact exercises. Wearables have the potential to provide data that can help with continuous monitoring of patients during therapy phases or preventive exercise programs in everyday life. This study aimed to determine the accuracy and reliability of measured acceleration data at different body positions compared to accelerations at the pelvis during different jumping exercises. Accelerations at the hips have been investigated in previous studies with regard to osteoporosis prevention. Data were collected using an IMU-based motion capture system (Xsens) consisting of 17 sensors. Forty-nine subjects were included in this study. The analysis shows the correlation between impacts and the corresponding drop height, which are dependent on the respective exercise. Very high correlations (0.83-0.94) were found between accelerations at the pelvis and the other measured segments at the upper body. The foot sensors provided very weak correlations (0.20-0.27). Accelerations measured at the pelvis during jumping exercises can be tracked very well on the upper body and upper extremities, including locations where smart devices are typically worn, which gives possibilities for remote and continuous monitoring of programs.}, language = {en} } @article{MoragKieningerEissnertetal., author = {Morag, Sarah and Kieninger, Martin and Eissnert, Christoph and Auer, Simon and Dendorfer, Sebastian and Popp, Daniel and Hoffmann, Johannes and Kieninger, B{\"a}rbel}, title = {Comparison of different techniques for prehospital cervical spine immobilization: Biomechanical measurements with a wireless motion capture system}, series = {PLOS ONE}, volume = {18}, journal = {PLOS ONE}, number = {11}, publisher = {PLOS}, address = {San Francisco, California}, doi = {10.1371/journal.pone.0292300}, pages = {1 -- 14}, language = {en} } @article{ReinkerDendorfer, author = {Reinker, Lukas and Dendorfer, Sebastian}, title = {Evaluation of acceleration patterns during high-impact jumping exercises}, series = {Gait \& Posture}, volume = {100}, journal = {Gait \& Posture}, number = {Supplement 1, March}, publisher = {Elsevier}, address = {Amsterdam [u.a.]}, doi = {10.1016/j.gaitpost.2022.11.051}, pages = {93 -- 94}, language = {en} } @article{MelznerIsmailRušavyetal., author = {Melzner, Maximilian and Ismail, Khaled and Rušavy, Zdenek and Kališ, Vladim{\´i}r and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal lower back load of accoucheurs during childbirth - A pilot and feasibility study}, series = {European Journal of Obstetrics \& Gynecology and Reproductive Biology}, journal = {European Journal of Obstetrics \& Gynecology and Reproductive Biology}, number = {264}, publisher = {Elsevier}, doi = {10.1016/j.ejogrb.2021.07.042}, pages = {306 -- 313}, abstract = {Introduction: Back problems represent one of the leading causes of accouchers' work-related musculoskeletal morbidities. The correct execution of birth-related maneuvers including manual perineal protection is crucial not only for the mother and child but also for obstetricians and midwives to reduce any strain on their musculoskeletal system. Therefore, the overall aim of this study was to test the feasibility of determining the effect of different accouchers' postures (standing and kneeling) on their musculoskeletal system. Methods: The biomechanical analysis is based on musculoskeletal simulations that included motion recordings of real deliveries as well as deliveries conducted on a birthing simulator. These simulations were then used to determine individual joints' loads. Results: In the kneeling posture, both a low intra-operator variability and a lower average maximum load of the lower back was observed. For the standing position the spine load was reduced by pivoting the elbow on the accouchers' thigh, which in turn was associated with a significantly greater load on the shoulder joint. Conclusion: The study demonstrated the feasibility of our technique to assess joints loads. It also provided initial data indicating that a posture that reduces spinal flexion and tilt, achieved in this study by the kneeling, can significantly reduce the strain on the practitioner's musculoskeletal system.}, language = {en} } @article{EngelhardtMelznerHavelkovaetal., author = {Engelhardt, Lucas and Melzner, Maximilian and Havelkova, Linda and Fiala, Pavel and Christen, Patrik and Dendorfer, Sebastian and Simon, Ulrich}, title = {A new musculoskeletal AnyBodyTM detailed hand model}, series = {Computer Methods in Biomechanics and Biomedical Engineering}, volume = {24}, journal = {Computer Methods in Biomechanics and Biomedical Engineering}, number = {7}, publisher = {Taylor \& Francis}, doi = {10.1080/10255842.2020.1851367}, pages = {777 -- 787}, abstract = {Musculoskeletal research questions regarding the prevention or rehabilitation of the hand can be addressed using inverse dynamics simulations when experiments are not possible. To date, no complete human hand model implemented in a holistic human body model has been fully developed. The aim of this work was to develop, implement, and validate a fully detailed hand model using the AnyBody Modelling System (AMS) (AnyBody, Aalborg, Denmark). To achieve this, a consistent multiple cadaver dataset, including all extrinsic and intrinsic muscles, served as a basis. Various obstacle methods were implemented to obtain with the correct alignment of the muscle paths together with the full range of motion of the fingers. These included tori, cylinders, and spherical ellipsoids. The origin points of the lumbrical muscles within the tendon of the flexor digitorum profundus added a unique feature to the model. Furthermore, the possibility of an entire patient-specific scaling based on the hand length and width were implemented in the model. For model validation, experimental datasets from the literature were used, which included the comparison of numerically calculated moment arms of the wrist, thumb, and index finger muscles. In general, the results displayed good comparability of the model and experimental data. However, the extrinsic muscles showed higher accordance than the intrinsic ones. Nevertheless, the results showed, that the proposed developed inverse dynamics hand model offers opportunities in a broad field of applications, where the muscles and joint forces of the forearm play a crucial role.}, language = {en} } @article{AuerSchieblIversenetal., author = {Auer, Simon and Schiebl, Jonas and Iversen, Kristoffer and Subhash Chander, Divyaksh and Damsgaard, Michael and Dendorfer, Sebastian}, title = {Biomechanical assessment of the design and efficiency of occupational exoskeletons with the AnyBody Modeling System}, series = {Zeitschrift f{\"u}r Arbeitswissenschaften}, volume = {76}, journal = {Zeitschrift f{\"u}r Arbeitswissenschaften}, number = {4}, publisher = {Springer Nature}, doi = {10.1007/s41449-022-00336-4}, pages = {440 -- 449}, abstract = {Exoskeletons were invented over 100 years ago but have only become popular in the last two decades, especially in the working industry as they can decrease work-related loads significantly. The most often used exoskeletons are for the lower back and shoulder since these are commonly affected body regions. All devices have in common that their purpose is to reduce internal loads of vulnerable body regions. Nevertheless, there is still little understanding on how biomechanical loading in the human body changes when exoskeletons are used. Therefore, further analyses are needed. A promising candidate for these are musculoskeletal models, which are based on an inverse dynamics approach and can calculate external parameters such as ground reaction forces or other interaction forces as well as internal parameters such as joint reaction forces or muscle activities. The various examples in the literature show that these models are increasingly used for assessing the biomechanical effects of exoskeletons on the human body. Furthermore, musculoskeletal models can calculate biomechanical loadings of humans with and without exoskeletons for all kinds of applications and allow an evaluation of their purpose. Practical Relevance: This article highlights the possibilities of musculoskeletal models for assessing the design and efficiency of occupational exoskeletons. Several practical use cases are described along with distinct descriptions of common implications of musculoskeletal and exoskeleton modeling.}, language = {en} }