@article{MaierDesernoHandelsetal., author = {Maier, Andreas and Deserno, Thomas M. and Handels, Heinz and Maier-Hein, Klaus H. and Palm, Christoph and Tolxdorff, Thomas}, title = {IJCARS: BVM 2021 special issue}, series = {International Journal of Computer Assisted Radiology and Surgery}, volume = {16}, journal = {International Journal of Computer Assisted Radiology and Surgery}, publisher = {Springer}, doi = {10.1007/s11548-021-02534-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-21666}, pages = {2067 -- 2068}, abstract = {The German workshop on medical image computing (BVM) has been held in different locations in Germany for more than 20 years. In terms of content, BVM focused on the computer-aided analysis of medical image data with a wide range of applications, e.g. in the area of imaging, diagnostics, operation planning, computer-aided intervention and visualization. During this time, there have been remarkable methodological developments and upheavals, on which the BVM community has worked intensively. The area of machine learning should be emphasized, which has led to significant improvements, especially for tasks of classification and segmentation, but increasingly also in image formation and registration. As a result, work in connection with deep learning now dominates the BVM. These developments have also contributed to the establishment of medical image processing at the interface between computer science and medicine as one of the key technologies for the digitization of the health system. In addition to the presentation of current research results, a central aspect of the BVM is primarily the promotion of young scientists from the diverse BVM community, covering not only Germany but also Austria, Switzerland, The Netherland and other European neighbors. The conference serves primarily doctoral students and postdocs, but also students with excellent bachelor and master theses as a platform to present their work, to enter into professional discourse with the community, and to establish networks with specialist colleagues. Despite the many conferences and congresses that are also relevant for medical image processing, the BVM has therefore lost none of its importance and attractiveness and has retained its permanent place in the annual conference rhythm. Building on this foundation, there are some innovations and changes this year. The BVM 2021 was organized for the first time at the Ostbayerische Technische Hochschule Regensburg (OTH Regensburg, a technical university of applied sciences). After Aachen, Berlin, Erlangen, Freiburg, Hamburg, Heidelberg, Leipzig, L{\"u}beck, and Munich, Regensburg is not just a new venue. OTH Regensburg is the first representative of the universities of applied sciences (HAW) to organize the conference, which differs to universities, university hospitals, or research centers like Fraunhofer or Helmholtz. This also considers the further development of the research landscape in Germany, where HAWs increasingly contribute to applied research in addition to their focus on teaching. This development is also reflected in the contributions submitted to the BVM in recent years. At BVM 2021, which was held in a virtual format for the first time due to the Corona pandemic, an attractive and high-quality program was offered. Fortunately, the number of submissions increased significantly. Out of 97 submissions, 26 presentations, 51 posters and 5 software demonstrations were accepted via an anonymized reviewing process with three reviews each. The three best works have been awarded BVM prizes, selected by a separate committee. Based on these high-quality submissions, we are able to present another special issue in the International Journal of Computer Assisted Radiology and Surgery (IJCARS). Out of the 97 submissions, the ones with the highest scores have been invited to submit an extended version of their paper to be presented in IJCARS. As a result, we are now able to present this special issue with seven excellent articles. Many submissions focus on machine learning in a medical context.}, subject = {Bildgebendes Verfahren}, language = {en} } @misc{KreftingZaunsederSaeringetal., author = {Krefting, Dagmar and Zaunseder, Sebastian and S{\"a}ring, Dennis and Wittenberg, Thomas and Palm, Christoph and Schiecke, Karin and Krenkel, Lars and Hennemuth, Anja and Schnell, Susanne and Spicher, Nicolai}, title = {Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand: Innovative Erfassung und Bewertung - Schwerpunkt bildbasierte Verfahren}, series = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, journal = {66. Jahrestagung der Deutschen Gesellschaft f{\"u}r Medizinische Informatik, Biometrie und Epidemiologie e. V. (GMDS), 12. Jahreskongress der Technologie- und Methodenplattform f{\"u}r die vernetzte medizinische Forschung e. V. (TMF), 26. - 30.09.2021, online}, doi = {10.3205/21gmds016}, url = {http://nbn-resolving.de/urn:nbn:de:0183-21gmds0167}, abstract = {Einleitung: Blutdruck gilt als sogenannter Vitalparameter als einer der grundlegenden Indikatoren f{\"u}r den Gesundheitszustand einer Person. Sowohl zu niedriger als auch zu hoher Blutdruck kann lebensbedrohend sein, letzerer ist dar{\"u}ber hinaus ein Risikofaktor insbesondere f{\"u}r Herz-Kreislauferkrankungen, die trotz wichtiger Fortschritte in der Behandlung immer noch die h{\"a}ufigste Todesursache in Deutschland darstellen. Die H{\"a}modynamik, also die raumzeitliche Dynamik des Blutflusses, und der Gef{\"a}ßzustand sind eng verbunden mit dem Blutdruck und ebenfalls von hoher klinischer Relevanz, u.a. zur Identifikation von Durchblutungsst{\"o}rungen und ung{\"u}nstigen Druckverteilungen der Gef{\"a}ßwand. Innovationen in der Messtechnik als auch in der Datenanalyse bieten heute neue M{\"o}glichkeiten der Erfassung und Bewertung von Blutdruck, H{\"a}modynamik und Gef{\"a}ßzustand [1], [2], [3], [4]. Methodik: In einer gemeinsamen Workshopserie der AG Medizinische Bild- und Signalverarbeitung der GMDS und des Fachausschusses Biosignale der DGBMT werden wir neue Ans{\"a}tze und L{\"o}sungen f{\"u}r Mess- und Analyseverfahren zu Blutdruck und -fluss sowie zum Gef{\"a}ßzustand vorstellen und diskutieren. Dabei stehen im ersten Workshop auf der GMDS Jahrestagung Bildbasierte Verfahren im Zentrum, w{\"a}hrend der zweite Workshop auf der DGBMT Jahrestagung den Fokus auf Biosignalbasierten Verfahren legt. Es werden aktuelle Forschungsergebnisse vorgestellt und diskutiert. Es sind jeweils mehrere Vortr{\"a}ge geplant mit ausreichend Zeit zur Diskussion. Folgende Vortr{\"a}ge sind geplant (Arbeitstitel): Sebastian Zaunseder: Videobasierte Erfassung des Blutdrucks Anja Hennemuth: A Visualization Toolkit for the Analysis of Aortic Anatomy and Pressure Distribution Lars Krenkel: Numerische Analyse der Rupturwahrscheinlichkeit zerebraler Aneurysmata Susanne Schnell: Messung des Blutflusses und h{\"a}modynamischer Parameter mit 4D flow MRI: M{\"o}glichkeiten und Herausforderungen Ergebnisse: Ziel des Workshops ist die Identifikation von innovativen Ans{\"a}tzen und neuen Methoden zur qualitativen und quantitativen Bestimmung von h{\"a}modynamischen Parametern sowie deren kritische Bewertung durch die Community f{\"u}r die Eignung in der klinischen Entscheidungsunterst{\"u}tzung. Diskussion: Der Workshop leistet inhaltlich einen Beitrag zu zentralen Aspekten f{\"u}r die Herz-Kreislauf-Medizin. Er bringt dabei Expertise aus verschiedenen Bereichen zusammen und schl{\"a}gt die Br{\"u}cke zwischen Kardiologie, Medizininformatik und Medizintechnik. Schlussfolgerung: Innovative Technologien aus Medizintechnik und Informatik erm{\"o}glichen zunehmend einfache und raumzeitlich aufgel{\"o}ste Erfassung und Bewertung wichtiger Informationen zur Unterst{\"u}tzung von Diagnose und Therapieverfolgung. [1] Zaunseder S, Trumpp A, Wedekind D, Malberg H. Cardiovascular assessment by imaging photoplethysmography - a review. Biomed Tech (Berl). 2018 Oct 25;63(5):617-34. [2] Huellebrand M, Messroghli D, Tautz L, Kuehne T, Hennemuth A. An extensible software platform for interdisciplinary cardiovascular imaging research. Comput Methods Programs Biomed. 2020 Feb;184:105277. [3] Schmitter S, Adriany G, Waks M, Moeller S, Aristova M, Vali A, et al. Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T. Magn Reson Med. 2020 Oct;84(4):1947-60. [4] Birkenmaier C, and Krenkel, L. Flow in Artificial Lungs. In: New Results in Numerical and Experimental Fluid Mechanics XIII. Contributions to the 22nd STAB/DGLR Symposium. Springer; 2021.}, subject = {Blutdruck}, language = {de} } @article{DesernoHandelsMaierHeinetal., author = {Deserno, Thomas M. and Handels, Heinz and Maier-Hein, Klaus H. and Mersmann, Sven and Palm, Christoph and Tolxdorff, Thomas and Wagenknecht, Gudrun and Wittenberg, Thomas}, title = {Viewpoints on Medical Image Processing}, series = {Current Medical Imaging Reviews}, volume = {9}, journal = {Current Medical Imaging Reviews}, number = {2}, doi = {10.2174/1573405611309020002}, pages = {79 -- 88}, abstract = {Medical image processing provides core innovation for medical imaging. This paper is focused on recent developments from science to applications analyzing the past fifteen years of history of the proceedings of the German annual meeting on medical image processing (BVM). Furthermore, some members of the program committee present their personal points of views: (i) multi-modality for imaging and diagnosis, (ii) analysis of diffusion-weighted imaging, (iii) model-based image analysis, (iv) registration of section images, (v) from images to information in digital endoscopy, and (vi) virtual reality and robotics. Medical imaging and medical image computing is seen as field of rapid development with clear trends to integrated applications in diagnostics, treatment planning and treatment.}, subject = {Bildgebendes Verfahren}, language = {en} } @article{PalmAxerGraesseletal., author = {Palm, Christoph and Axer, Markus and Gr{\"a}ßel, David and Dammers, J{\"u}rgen and Lindemeyer, Johannes and Zilles, Karl and Pietrzyk, Uwe and Amunts, Katrin}, title = {Towards ultra-high resolution fibre tract mapping of the human brain}, series = {Frontiers in Human Neuroscience}, volume = {4}, journal = {Frontiers in Human Neuroscience}, doi = {10.3389/neuro.09.009.2010}, pages = {9}, abstract = {Polarised light imaging (PLI) utilises the birefringence of the myelin sheaths in order to visualise the orientation of nerve fibres in microtome sections of adult human post-mortem brains at ultra-high spatial resolution. The preparation of post-mortem brains for PLI involves fixation, freezing and cutting into 100-μm-thick sections. Hence, geometrical distortions of histological sections are inevitable and have to be removed for 3D reconstruction and subsequent fibre tracking. We here present a processing pipeline for 3D reconstruction of these sections using PLI derived multimodal images of post-mortem brains. Blockface images of the brains were obtained during cutting; they serve as reference data for alignment and elimination of distortion artefacts. In addition to the spatial image transformation, fibre orientation vectors were reoriented using the transformation fields, which consider both affine and subsequent non-linear registration. The application of this registration and reorientation approach results in a smooth fibre vector field, which reflects brain morphology. PLI combined with 3D reconstruction and fibre tracking is a powerful tool for human brain mapping. It can also serve as an independent method for evaluating in vivo fibre tractography.}, subject = {Bildgebendes Verfahren}, language = {en} } @inproceedings{WeihererZornWittenbergetal., author = {Weiherer, Maximilian and Zorn, Martin and Wittenberg, Thomas and Palm, Christoph}, title = {Retrospective Color Shading Correction for Endoscopic Images}, series = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2020. Algorithmen - Systeme - Anwendungen. Proceedings des Workshops vom 15. bis 17. M{\"a}rz 2020 in Berlin}, editor = {Tolxdorff, Thomas and Deserno, Thomas M. and Handels, Heinz and Maier, Andreas and Maier-Hein, Klaus H. and Palm, Christoph}, publisher = {Springer Vieweg}, address = {Wiesbaden}, isbn = {978-3-658-29266-9}, doi = {10.1007/978-3-658-29267-6}, pages = {14 -- 19}, abstract = {In this paper, we address the problem of retrospective color shading correction. An extension of the established gray-level shading correction algorithm based on signal envelope (SE) estimation to color images is developed using principal color components. Compared to the probably most general shading correction algorithm based on entropy minimization, SE estimation does not need any computationally expensive optimization and thus can be implemented more effciently. We tested our new shading correction scheme on artificial as well as real endoscopic images and observed promising results. Additionally, an indepth analysis of the stop criterion used in the SE estimation algorithm is provided leading to the conclusion that a fixed, user-defined threshold is generally not feasible. Thus, we present new ideas how to develop a non-parametric version of the SE estimation algorithm using entropy.}, subject = {Endoskopie}, language = {en} } @misc{BeyerWeigertPalmetal., author = {Beyer, Thomas and Weigert, Markus and Palm, Christoph and Quick, Harald H. and M{\"u}ller, Stefan P. and Pietrzyk, Uwe and Vogt, Florian and Martinez, M.J. and Bockisch, Andreas}, title = {Towards MR-based attenuation correction for whole-body PET/MR imaging}, series = {The Journal of Nuclear Medicine}, volume = {47}, journal = {The Journal of Nuclear Medicine}, number = {Suppl. 1}, pages = {384P}, subject = {Kernspintomografie}, language = {en} } @article{WeigertPietrzykMuelleretal., author = {Weigert, Markus and Pietrzyk, Uwe and M{\"u}ller, Stefan P. and Palm, Christoph and Beyer, Thomas}, title = {Whole-body PET/CT imaging}, series = {Zeitschrift f{\"u}r Medizinische Physik}, volume = {18}, journal = {Zeitschrift f{\"u}r Medizinische Physik}, number = {1}, doi = {10.1016/j.zemedi.2007.07.004}, pages = {59 -- 66}, abstract = {Aim Combined whole-body (WB) PET/CT imaging provides better overall co-registration compared to separate CT and PET. However, in clinical routine local PET-CT mis-registration cannot be avoided. Thus, the reconstructed PET tracer distribution may be biased when using the misaligned CT transmission data for CT-based attenuation correction (CT-AC). We investigate the feasibility of retrospective co-registration techniques to align CT and PET images prior to CT-AC, thus improving potentially the quality of combined PET/CT imaging in clinical routine. Methods First, using a commercial software registration package CT images were aligned to the uncorrected PET data by rigid and non-rigid registration methods. Co-registration accuracy of both alignment approaches was assessed by reviewing the PET tracer uptake patterns (visual, linked cursor display) following attenuation correction based on the original and co-registered CT. Second, we investigated non-rigid registration based on a prototype ITK implementation of the B-spline algorithm on a similar targeted MR-CT registration task, there showing promising results. Results Manual rigid, landmark-based co-registration introduced unacceptable misalignment, in particular in peripheral areas of the whole-body images. Manual, non-rigid landmark-based co-registration prior to CT-AC was successful with minor loco-regional distortions. Nevertheless, neither rigid nor non-rigid automatic co-registration based on the Mutual Information image to image metric succeeded in co-registering the CT and noAC-PET images. In contrast to widely available commercial software registration our implementation of an alternative automated, non-rigid B-spline co-registration technique yielded promising results in this setting with MR-CT data. Conclusion In clinical PET/CT imaging, retrospective registration of CT and uncorrected PET images may improve the quality of the AC-PET images. As of today no validated and clinically viable commercial registration software is in routine use. This has triggered our efforts in pursuing new approaches to a validated, non-rigid co-registration algorithm applicable to whole-body PET/CT imaging of which first results are presented here. This approach appears suitable for applications in retrospective WB-PET/CT alignment. Ziel Kombinierte PET/CT-Bildgebung erm{\"o}glicht verbesserte Koregistrierung von PET- und CT-Daten gegen{\"u}ber separat akquirierten Bildern. Trotzdem entstehen in der klinischen Anwendung lokale Fehlregistrierungen, die zu Fehlern in der rekonstruierten PET- Tracerverteilung f{\"u}hren k{\"o}nnen, falls die unregistrierten CT-Daten zur Schw{\"a}chungskorrektur (AC) der Emissionsdaten verwendet werden. Wir untersuchen daher die Anwendung von Bildregistrierungsalgorithmen vor der CT-basierten AC zur Verbesserung der PET-Aufnahmen. Methoden Mittels einer kommerziellen Registrierungssoftware wurden die CT-Daten eines PET/CT- Tomographen durch landmarken- und intensit{\"a}tsbasierte rigide (starre) und nicht-rigide Registrierungsverfahren r{\"a}umlich an die unkorrigierten PET-Emissionsdaten angepasst und zur AC verwendet. Zur Bewertung wurden die Tracerverteilungen in den PET-Bildern (vor AC, CT-AC, CT-AC nach Koregistrierung) visuell und mit Hilfe korrelierter Fadenkreuze verglichen. Zus{\"a}tzlich untersuchten wir die ITK-Implementierung der bekannten B-spline basierten, nicht-rigiden Registrierungsans{\"a}tze im Hinblick auf ihre Verwendbarkeit f{\"u}r die multimodale PET/CT-Ganzk{\"o}rperregistrierung. Ergebnisse Mittels landmarkenbasierter, nicht-rigider Registrierung konnte die Tracerverteilung in den PET-Daten lokal verbessert werden. Landmarkenbasierte rigide Registrierung f{\"u}hrte zu starker Fehlregistrierung in entfernten K{\"o}rperregionen. Automatische rigide und nicht-rigide Registrierung unter Verwendung der Mutual-Information-{\"A}hnlichkeitsmetrik versagte auf allen verwendeten Datens{\"a}tzen. Die automatische Registrierung mit B-spline-Funktionen zeigte vielversprechende Resultate in der Anwendung auf einem {\"a}hnlich gelagerten CT-MR-Registrierungsproblem. Fazit Retrospektive, nicht-rigide Registrierung unkorrigierter PET- und CT-Aufnahmen aus kombinierten Aufnahmensystemen vor der AC kann die Qualit{\"a}t von PET-Aufnahmen im klinischen Einsatz verbessern. Trotzdem steht bis heute im klinischen Alltag keine validierte, automatische Registrierungssoftware zur Verf{\"u}gung. Wir verfolgen dazu Ans{\"a}tze f{\"u}r validierte, nicht-rigide Bildregistrierung f{\"u}r den klinischen Einsatz und pr{\"a}sentieren erste Ergebnisse.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{BeckerZoriyMatuschetal., author = {Becker, Johanna Sabine and Zoriy, Miroslav and Matusch, Andreas and Wu, Bei and Salber, Dagmar and Palm, Christoph and Becker, Julia Susanne}, title = {Bioimaging of Metals by Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS)}, series = {Mass Spectrometry Reviews}, volume = {29}, journal = {Mass Spectrometry Reviews}, doi = {10.1002/mas.20239}, pages = {156 -- 175}, abstract = {The distribution analysis of (essential, beneficial, or toxic) metals (e.g., Cu, Fe, Zn, Pb, and others), metalloids, and non-metals in biological tissues is of key interest in life science. Over the past few years, the development and application of several imaging mass spectrometric techniques has been rapidly growing in biology and medicine. Especially, in brain research metalloproteins are in the focus of targeted therapy approaches of neurodegenerative diseases such as Alzheimer's and Parkinson's disease, or stroke, or tumor growth. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) using double-focusing sector field (LA-ICP-SFMS) or quadrupole-based mass spectrometers (LA-ICP-QMS) has been successfully applied as a powerful imaging (mapping) technique to produce quantitative images of detailed regionally specific element distributions in thin tissue sections of human or rodent brain. Imaging LA-ICP-QMS was also applied to investigate metal distributions in plant and animal sections to study, for example, the uptake and transport of nutrient and toxic elements or environmental contamination. The combination of imaging LA-ICP-MS of metals with proteomic studies using biomolecular mass spectrometry identifies metal-containing proteins and also phosphoproteins. Metal-containing proteins were imaged in a two-dimensional gel after electrophoretic separation of proteins (SDS or Blue Native PAGE). Recent progress in LA-ICP-MS imaging as a stand-alone technique and in combination with MALDI/ESI-MS for selected life science applications is summarized.}, subject = {Bildgebendes Verfahren}, language = {en} } @article{AxerAmuntsGraesseletal., author = {Axer, Markus and Amunts, Katrin and Gr{\"a}ßel, David and Palm, Christoph and Dammers, J{\"u}rgen and Axer, Hubertus and Pietrzyk, Uwe and Zilles, Karl}, title = {Novel Approach to the Human Connectome}, series = {NeuroImage}, volume = {54}, journal = {NeuroImage}, number = {2}, doi = {10.1016/j.neuroimage.2010.08.075}, pages = {1091 -- 1101}, abstract = {Signal transmission between different brain regions requires connecting fiber tracts, the structural basis of the human connectome. In contrast to animal brains, where a multitude of tract tracing methods can be used, magnetic resonance (MR)-based diffusion imaging is presently the only promising approach to study fiber tracts between specific human brain regions. However, this procedure has various inherent restrictions caused by its relatively low spatial resolution. Here, we introduce 3D-polarized light imaging (3D-PLI) to map the three-dimensional course of fiber tracts in the human brain with a resolution at a submillimeter scale based on a voxel size of 100 μm isotropic or less. 3D-PLI demonstrates nerve fibers by utilizing their intrinsic birefringence of myelin sheaths surrounding axons. This optical method enables the demonstration of 3D fiber orientations in serial microtome sections of entire human brains. Examples for the feasibility of this novel approach are given here. 3D-PLI enables the study of brain regions of intense fiber crossing in unprecedented detail, and provides an independent evaluation of fiber tracts derived from diffusion imaging data.}, subject = {Bildgebendes Verfahren}, language = {en} } @inproceedings{EibenPalmPietrzyketal., author = {Eiben, Bj{\"o}rn and Palm, Christoph and Pietrzyk, Uwe and Davatzikos, Christos and Amunts, Katrin}, title = {Error Correction using Registration for Blockface Volume Reconstruction of Serial Histological Sections of the Human Brain}, series = {Bildverarbeitung f{\"u}r die Medizin 2010; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2010; Algorithmen - Systeme - Anwendungen ; Proceedings des Workshops vom 22. bis 25. M{\"a}rz 2009 in Heidelberg}, publisher = {Springer}, address = {Berlin}, pages = {301 -- 305}, abstract = {For accurate registration of histological sections blockface images are frequently used as three dimensional reference. However, due to the use of endocentric lenses the images suffer from perspective errors such as scaling and seemingly relative movement of planes which are located in different distances parallel to the imaging sensor. The suggested correction of those errors is based on the estimation of scaling factors derived from image registration of regions characterized by differing distances to the point of view in neighboring sections. The correction allows the generation of a consistent three dimensional blockface volume.}, subject = {Histologie}, language = {en} }