@misc{LautenschlaegerLeisDendorferetal., author = {Lautenschl{\"a}ger, Toni and Leis, Alexander and Dendorfer, Sebastian and Palm, Christoph and Schreiner, Rupert and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Dams, Florian and Bornmann, Benjamin and Navitski, Aliaksandr and Serbun, Pavel and M{\"u}ller, G{\"u}nter and Liebetruth, Thomas and Kohlert, Dieter and Pernsteiner, Jochen and Schreier, Franz and Heerklotz, Sabrina and Heerklotz, Allwin and Boos, Alexander and Herwald, Dominik and Monkman, Gareth J. and Treiber, Daniel and Mayer, Matthias and H{\"o}rner, Eva and Bentz, Alexander and Shamonin (Chamonine), Mikhail and Johansen, S{\o}ren Peter and Reichel, Marco and Stoll, Andrea and Briem, Ulrich and Dullien, Silvia and Renkawitz, Tobias and Weber, Tim and Dendorfer, Sebastian and Grifka, Joachim and Penzkofer, Rainer and Barnsteiner, K. and Jovanovik, M. and Wernecke, P. and V{\"o}gele, A. and Bachmann, T. and Pl{\"o}tz, Martin and Schliekmann, Claus and Wels, Harald and Helmberger, Paul and Kaspar, Marcel and H{\"o}nicka, M. and Schrammel, Siegfried and Enser, Markus and Schmidmeier, Monika and Schroll-Decker, Irmgard and Haug, Sonja and Gelfert, Verena and Vernim, Matthias}, title = {Forschungsbericht 2012}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, doi = {10.35096/othr/pub-783}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-7834}, pages = {64}, language = {de} } @misc{AppelhansKampmannMottoketal., author = {Appelhans, Marie-Luise and Kampmann, Matthias and Mottok, J{\"u}rgen and Riederer, Michael and Nagl, Klaus and Steffens, Oliver and D{\"u}nnweber, Jan and Wildgruber, Markus and Roth, Julius and Stadler, Timo and Palm, Christoph and Weiß, Martin Georg and Rochholz, Sandra and Bierl, Rudolf and Gschossmann, Andreas and Haug, Sonja and Schmidbauer, Simon and Koch, Anna and Westner, Markus and Bary, Benedikt von and Ellermeier, Andreas and V{\"o}gele, Daniel and Maiwald, Frederik and Hierl, Stefan and Schlamp, Matthias and Ehrlich, Ingo and Siegl, Marco and H{\"u}ntelmann, Sven and Wildfeuer, Matthias and Br{\"u}ckl, Oliver and Sterner, Michael and Hofrichter, Andreas and Eckert, Fabian and Bauer, Franz and Dawoud, Belal and Rabl, Hans-Peter and Gamisch, Bernd and Schmidt, Ottfried and Heberl, Michael and Thema, Martin and Mayer, Ulrike and Eller, Johannes and Sippenauer, Thomas and Adelt, Christian and Haslbeck, Matthias and Vogl, Bettina and Mauerer, Wolfgang and Ramsauer, Ralf and Lohmann, Daniel and Sax, Irmengard and Gabor, Thomas and Feld, Sebastian and Linnhoff-Popien, Claudia and Ławrowski, Robert Damian and Langer, Christoph and Schreiner, Rupert and Sellmair, Josef}, title = {Forschung 2019}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-7-3}, doi = {10.35096/othr/pub-789}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-7890}, pages = {72}, abstract = {Bericht mit Forschungsprojekten aus verschiedenen Bereichen der OTH Regensburg mit dem Schwerpunktthema "K{\"u}nstliche Intelligenz" und einem Gespr{\"a}ch zur "Medizin der Zukunft"}, subject = {Forschung}, language = {de} } @misc{WeberDendorferSuessetal., author = {Weber, Karsten and Dendorfer, Sebastian and S{\"u}ß, Franz and Kubowitsch, Simone and Schratzenstaller, Thomas and Haug, Sonja and Mohr, Christa and Kiesl, Hans and Drechsler, J{\"o}rg and Westner, Markus and Kobus, J{\"o}rn and Schubert, Martin J. W. and Zenger, Stefan and Pietsch, Alexander and Weiß, Josef and Hinterseer, Sebastian and Schieck, Roland and Scherzinger, Stefanie and Klettke, Meike and Ringlstetter, Andreas and St{\"o}rl, Uta and Bissyand{\´e}, Tegawend{\´e} F. and Seeburger, Achim and Schindler, Timo and Ramsauer, Ralf and Kiszka, Jan and K{\"o}lbl, Andreas and Lohmann, Daniel and Mauerer, Wolfgang and Maier, Johannes and Scorna, Ulrike and Palm, Christoph and Soska, Alexander and Mottok, J{\"u}rgen and Ellermeier, Andreas and V{\"o}gele, Daniel and Hierl, Stefan and Briem, Ulrich and Buschmann, Knut and Ehrlich, Ingo and Pongratz, Christian and Pielmeier, Benjamin and Tyroller, Quirin and Monkman, Gareth J. and Gut, Franz and Roth, Carina and Hausler, Peter and Bierl, Rudolf and Prommesberger, Christian and Ławrowski, Robert Damian and Langer, Christoph and Schreiner, Rupert and Huang, Yifeng and She, Juncong and Ottl, Andreas and Rieger, Walter and Kraml, Agnes and Poxleitner, Thomas and Hofer, Simon and Heisterkamp, Benjamin and Lerch, Maximilian and Sammer, Nike and Golde, Olivia and Wellnitz, Felix and Schmid, Sandra and Muntschick, Claudia and Kusterle, Wolfgang and Paric, Ivan and Br{\"u}ckl, Oliver and Haslbeck, Matthias and Schmidt, Ottfried and Schwanzer, Peter and Rabl, Hans-Peter and Sterner, Michael and Bauer, Franz and Steinmann, Sven and Eckert, Fabian and Hofrichter, Andreas}, title = {Forschungsbericht 2017}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-3-5}, doi = {10.35096/othr/pub-1383}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-13835}, subject = {Forschung}, language = {de} } @article{SerbunBornmannNavitskietal., author = {Serbun, Pavel and Bornmann, Benjamin and Navitski, Aliaksandr and M{\"u}ller, G{\"u}nter and Prommesberger, Christian and Langer, Christoph and Dams, Florian and Schreiner, Rupert}, title = {Stable field emission of single B-doped Si tips and linear current scaling of uniform tip arrays for integrated vacuum microelectronic devices}, series = {Journal of Vacuum Science \& Technology B Nanotechnology and Microelectronics}, volume = {31}, journal = {Journal of Vacuum Science \& Technology B Nanotechnology and Microelectronics}, number = {2}, publisher = {AIP Publishing}, doi = {10.1116/1.4765088}, abstract = {Advanced Si-based semiconductor technology is most suitable to fabricate uniform nanostructures as integrated field emitter arrays for novel vacuum electronic devices. In order to improve the field emission homogeneity and stability of p-type silicon tip arrays for pulsed sensor applications, the authors have systematically studied the influence of the fabrication parameters on the tip shape and on the specific operating conditions. Based on detailed design calculations of the field enhancement, they have fabricated two series of hexagonal arrays of B-doped Si-tips in a triangular arrangement. The first (second) type contains three (four) patches with different number of tips (1, 91, 547 and 1, 19, 1027, 4447 for the first and second type, respectively) of about 1 (2.5) μm height, ∼20 (20) nm apex radius, and 20 (10) μm pitch. The field emission properties of both individual tips and complete arrays were investigated with a field emission scanning microscope at a pressure of 10-9 mbar. The current plateau of these tips typically occurs at about 10 (3) nA and around 65 (25) V/μm field level. In this carrier saturation range, single tips provide the highest current stability (<5\%) and optical current switching ratio (∼2.5). Fairly homogeneous emission of the tip arrays leads to an undershooting of the expected linear scaling of the mean plateau current as well as to a much improved current stability (<1\%).}, language = {en} } @article{BiekerRoustaieSchlaaketal., author = {Bieker, Johannes and Roustaie, Farough and Schlaak, Helmut F. and Langer, Christoph and Schreiner, Rupert and Lotz, Marcel and Wilfert, Stefan}, title = {Field emission characterization of in situ deposited gold nanocones with variable cone densities}, series = {Journal of Vacuum Science and Technology B}, volume = {36}, journal = {Journal of Vacuum Science and Technology B}, number = {2}, publisher = {AIP Publishing}, doi = {10.1116/1.5009504}, abstract = {For the fabrication of field emitter cathodes with metallic nanocones, an in situ fabrication technique based on electrodeposition in an ion track etched polymer template was used. Three samples with nanocones made of gold and different cone densities were deposited on a circular electrode with a diameter of 2.5 mm, using templates with pore density of 6 × 104, 4 × 105, and 1 × 106 cones/cm2. The cones had a height of 24 μm, a base diameter between 3 and 3.75 μm, and a tip diameter below 500 nm. Integral field emission measurements revealed onset fields of down to 3.1 V/μm and average field enhancement factors of up to 1240. For one sample, the maximum emission current from the cathode reached 142.2 μA at an applied voltage of 338 V between cathode and extraction grid, which had a distance of 50 μm. To investigate the stability of the field emission current, cumulative long-term measurements were performed for over 50 h. A stable emission current of (31.0 ± 1.3) μA at an average applied voltage of 290 V (E = 5.8 V/μm) was observed. For currents above 100 μA, a decrease of the current and therefore a degradation of the emitter structures occurred.}, language = {en} } @misc{DuesbergBachmannEdleretal., author = {D{\"u}sberg, Felix and Bachmann, Michael and Edler, Simon and Pahlke, Andreas and Langer, Christoph and Prommesberger, Christian and Schreiner, Rupert and Bunert, Erik and Wendt, Cornelius and Zimmermann, Stefan}, title = {Novel Non-Radiative Electron Source}, series = {43rd International Symposium of Capillary Chromatography \& 16h GC x GC Symposium 2019}, journal = {43rd International Symposium of Capillary Chromatography \& 16h GC x GC Symposium 2019}, abstract = {Recently a non-radioactive electron capture detector based on a thermionic electron emitter has been demonstrated [1]. Using field emitter arrays (FEAs) would yield non-radioactive portable low power devices with fast switching capability. By combining FEAs with a vacuum-sealed housing and an electron transparent membrane window, such electron sources can be operated in an ambient pressure environment.}, language = {en} } @inproceedings{PrommesbergerLangerSchreiner, author = {Prommesberger, Christian and Langer, Christoph and Schreiner, Rupert}, title = {Stable and low noise field emission from single p-type Si-tips}, series = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, booktitle = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, publisher = {IEEE}, doi = {10.1109/IVNC.2018.8520018}, pages = {1-2}, abstract = {Single gated p-type Si-tips with two different tip radii were fabricated. An emission current of 2.40 μA was measured for the sharp-edged tip at a voltage of 170 V. In contrast, a stable and reproducible emission behavior was observed with an increased tip radius resulting in a pronounced saturation region between 90 V and 150 V, but merely an emission current of 0.55 μA at 150 V. More remarkable is the stable emission behavior with fluctuation of ± 4 \% during a measurement period of 30 minutes. The integral emission current in a homogeneous tip array (16 emitters) showed nearly the same I-V characteristics compared to the single tip and is therefore, most dominated by only a stable single tip in the array.}, language = {en} } @inproceedings{LindnerBerndtPrommesbergeretal., author = {Lindner, Matthias and Berndt, Dominik and Prommesberger, Christian and Langer, Christoph and Schreiner, Rupert}, title = {Field emission assisted micro plasma discharges at vacuum and atmospheric pressures}, series = {31st International Vacuum Nanoelectronics Conference (IVNC), 2018, Kyoto, Japan}, booktitle = {31st International Vacuum Nanoelectronics Conference (IVNC), 2018, Kyoto, Japan}, doi = {10.1109/IVNC.2018.8520181}, pages = {2}, abstract = {Spatially confined non-equilibrium plasmas at vacuum and atmospheric pressure in the dimensions from a few microns to one millimeter are a promising approach to the generation and maintenance of stable glow discharges. The realization of these micro-discharges or micro-plasmas enable more accurate investigations in the field of micro plasma research. We report on field emission assisted micro plasmas excited by an alternating current with frequencies up to 1 kHz. Due to the field enhancement caused by an array of Si nano-tip structures the ignition voltage of stable plasma discharges can be reduced by 30\%.}, language = {en} } @inproceedings{BerndtLindnerTschurtschenthaleretal., author = {Berndt, Dominik and Lindner, Matthias and Tschurtschenthaler, Karl and Langer, Christoph and Schreiner, Rupert}, title = {Miniaturized Plasma Actuator Flow Measurements by MEMS-Based Thermal Conductivity Sensors}, series = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, volume = {Vol.13}, booktitle = {MDPI Proceedings of Eurosensors 2018, 9-12 September, Graz}, number = {2}, doi = {10.3390/proceedings2130939}, abstract = {The gasflow created by a minaturized dielectric barrier discharge (DBD) plasma actuator is measured by a MEMS-based thermal conductivity gas sensor giving an indication of flow velocity and flow direction. The possiblity of several sensors in a small area gives a far better accuracy of local flow phenomena compared to conventional sensors. This is important for a better understanding of plasma- induced flow characteristics.}, language = {en} } @article{BerndtMuggliWittweretal., author = {Berndt, Dominik and Muggli, Josef and Wittwer, Franz and Langer, Christoph and Heinrich, Stephan and Knittel, Thorsten and Schreiner, Rupert}, title = {MEMS-based thermal conductivity sensor for hydrogen gas detection in automotive applications}, series = {Sensors and Actuators A: Physical}, volume = {305}, journal = {Sensors and Actuators A: Physical}, number = {April}, publisher = {Elsevier}, doi = {10.1016/j.sna.2019.111670}, abstract = {Accurate detection of hydrogen gas in vehicle interiors is very important for the future of a fuel cell car. Since this type of gas is highly volatile and flammable, the measurement methods have to be very reliable and precise due to safety reasons. In this paper a thermal conductivity sensor for hydrogen gas detection is presented, exhibiting a lower detection limit of 2000 ppm hydrogen in laboratory air. The sensor element is realized by micro-fabrication techniques on silicon wafers. The heated filament is exposed by a selective wet etching process creating a micro-hotplate on a thin membrane. In order to minimize power consumption, the sensor is operated in pulsed mode. Hydrogen gas detection was carried out using a synthetic gas testbench. Measurements of hydrogen contents ranging from 0\% to 4\% with an increment of 0.5\% were successfully performed for ambient gas temperatures between -15°C and 84°C. Including humidity, high moisture contents have the greatest influence on thermal conductivity. This was predicted in theoretical investigations and confirmed in experiments. For evaluation, both the change in resistance ΔR as well as the time constant τ were taken as sensor output. For both quantities, the previously established theoretical relationship with thermal conductivity could be confirmed.}, language = {en} }