@article{SavelevBelyaevaChashinetal., author = {Savelev, Dmitrii V. and Belyaeva, Inna A. and Chashin, Dmitri V. and Fetisov, Leonid Y. and Romeis, Dirk and Kettl, Wolfgang and Kramarenko, Elena Yu and Saphiannikova, Marina and Stepanov, Gennady V. and Shamonin (Chamonine), Mikhail}, title = {Giant extensional strain of magnetoactive elastomeric cylinders in uniform magnetic fields}, series = {Materials}, volume = {13}, journal = {Materials}, number = {15}, publisher = {MDPI}, address = {Basel}, issn = {1996-1944}, doi = {10.3390/ma13153297}, pages = {1 -- 17}, abstract = {Elongations of magnetoactive elastomers (MAEs) under ascending-descending uniform magnetic fields were studied experimentally using a laboratory apparatus specifically designed to measure large extensional strains (up to 20\%) in compliant MAEs. In the literature, such a phenomenon is usually denoted as giant magnetostriction. The synthesized cylindrical MAE samples were based on polydimethylsiloxane matrices filled with micrometer-sized particles of carbonyl iron. The impact of both the macroscopic shape factor of the samples and their magneto-mechanical characteristics were evaluated. For this purpose, the aspect ratio of the MAE cylindrical samples, the concentration of magnetic particles in MAEs and the effective shear modulus were systematically varied. It was shown that the magnetically induced elongation of MAE cylinders in the maximum magnetic field of about 400 kA/m, applied along the cylinder axis, grew with the increasing aspect ratio. The effect of the sample composition is discussed in terms of magnetic filler rearrangements in magnetic fields and the observed experimental tendencies are rationalized by simple theoretical estimates. The obtained results can be used for the design of new smart materials with magnetic-field-controlled deformation properties, e.g., for soft robotics.}, language = {en} } @article{SavelevFetisovChashinetal., author = {Savelev, Dmitrii V. and Fetisov, Leonid Y. and Chashin, Dmitri V. and Fetisov, Yuri K. and Khon, Anastasia and Shamonin (Chamonine), Mikhail}, title = {Effects of ferromagnetic-material thickness on magnetoelectric voltage transformation in a multiferroic heterostructure}, series = {Smart Materials and Structures}, volume = {30}, journal = {Smart Materials and Structures}, number = {6}, publisher = {IOP PUBLISHING}, doi = {10.1088/1361-665X/abf6c0}, abstract = {A magnetoelectric (ME) voltage transformer is fabricated on the basis of a ferromagnetic (FM)-piezoelectric (PE) heterostructure comprising two equally thick laminated layers of an amorphous FM alloy and a piezoceramic lead zirconate-titanate layer sandwiched between them. The structure, placed inside an excitation coil, is electrically poled and magnetized in the direction of the long axis. The primary voltage is applied to the coil and the secondary voltage is measured between the electrodes of the PE material. It is shown for the first time that the change in the total thickness of magnetic layers significantly influences the transformer ' s characteristics. At the largest total thickness of FM layers of 138 mu m, the open-circuit voltage transformation ratio K has a maximum value of about 20, and the power transfer efficiency eta at a matched resistive load of about 20 k omega reaches 45\%. The variation of the control magnetic field in the range of 0-21.6 kA m(-1) makes it possible to change the voltage transformation ratio K from zero to the maximum value. A simple model allows one to calculate the dependence of the characteristics of the ME transformer on the frequency of the primary voltage, thickness of the FM layers, control magnetic field, and the load.}, language = {en} } @article{SavelevBelyaevaChashinetal., author = {Savelev, Dmitrii V. and Belyaeva, Inna A. and Chashin, Dmitri V. and Fetisov, Leonid Y. and Shamonin (Chamonine), Mikhail}, title = {Large Wiedemann effect in a magnetoactive elastomer}, series = {Journal of Magnetism and Magnetic Materials}, volume = {511}, journal = {Journal of Magnetism and Magnetic Materials}, number = {October}, publisher = {Elsevier}, doi = {10.1016/j.jmmm.2020.166969}, abstract = {Large twists of a soft tube (hollow cylinder) in helical magnetic fields are presented for the first time. Such a phenomenon is usually denoted as the Wiedemann effect. The tube is fabricated from a soft magnetoactive elastomer material with the shear modulus of about 56 kPa. The composite material comprises 80 mass\% of micrometer-sized iron particles embedded into a polydimethylsiloxane matrix. The circular magnetic field is generated by an electric current in a straight wire passing through the inner hole of the tube. The maximum value of approximately 350″/cm is observed in a longitudinal magnetic field of a few kA/m overlapped with a circumferential magnetic field of about 1.4 kA/m on the surface of the inner hole. A pronounced hysteresis in the dependence of the Wiedemann effect on the circular magnetic field is found. The ways to enhance the Wiedemann twist in magnetoactive elastomers are discussed. The observed large effect is promising for application in magnetic-field controlled torsional actuators, in particular for soft robotics.}, language = {en} } @article{SavelevFetisovChashinetal., author = {Savelev, Dmitrii V. and Fetisov, Leonid Y. and Chashin, Dmitri V. and Shabin, P. A. and Vyunik, D. A. and Fedulov, Feodor and Kettl, Wolfgang and Shamonin (Chamonine), Mikhail}, title = {Method of Measuring Deformations of Magnetoactive Elastomers under the Action of Magnetic Fields}, series = {Russian Technological Journal}, volume = {7}, journal = {Russian Technological Journal}, number = {4}, doi = {10.32362/2500-316x-2019-7-4-81-91}, pages = {81 -- 91}, language = {ru} } @misc{PershinaSavelevGlavanetal., author = {Pershina, K. V. and Savelev, Dmitrii V. and Glavan, Gašper and Chashin, Dmitri V. and Belyaeva, Inna A. and Fetisov, Leonid Y. and Shamonin (Chamonine), Mikhail}, title = {The voltage response of a structure comprising a magnetoactive-elastomer cylinder and a piezoelectric material to magnetic field step excitations}, series = {The 4th International Baltic Conference on Magnetism (IBCM 2021) : Svetlogorsk, Russia August 29 - September 2, 2021 : Book of Abstracts}, journal = {The 4th International Baltic Conference on Magnetism (IBCM 2021) : Svetlogorsk, Russia August 29 - September 2, 2021 : Book of Abstracts}, publisher = {Immanuel Kant Baltic Federal University, Kaliningrad, Russia}, pages = {182}, language = {en} } @article{DillingerWeberMayeretal., author = {Dillinger, Andrea Elisabeth and Weber, Gregor R. and Mayer, Matthias and Schneider, Magdalena and G{\"o}ppner, Corinna and Ohlmann, Andreas and Shamonin (Chamonine), Mikhail and Monkman, Gareth J. and Fuchshofer, Rudolf and Keller, Kate and Lozano, Diana C. and Clark, Abbot}, title = {CCN2/CTGF-A Modulator of the Optic Nerve Head Astrocyte}, series = {Frontiers in cell and developmental biology (Front Cell Dev Biol.)}, volume = {10}, journal = {Frontiers in cell and developmental biology (Front Cell Dev Biol.)}, publisher = {frontiers}, doi = {10.3389/fcell.2022.864433}, pages = {864433}, abstract = {In primary open-angle glaucoma (POAG), a neurodegenerative disease of the optic nerve (ON) and leading cause of blindness, the optic nerve head (ONH) undergoes marked structural extracellular matrix (ECM) changes, which contribute to its permanent deformation and to degeneration of ON axons. The remodeling process of the ECM causes changes in the biomechanical properties of the ONH and the peripapillary sclera, which is accompanied by an increased reactivity of the resident astrocytes. The molecular factors involved in the remodeling process belong to the Transforming growth factor (TGF)-β superfamily, especially TGF-β2. In previous publications we showed that TGF-β2 induced ECM alterations are mediated by Cellular Communication Network Factor (CCN)2/Connective Tissue Growth Factor (CTGF) and recently we showed that CCN2/CTGF is expressed by astrocytes of the ON under normal conditions. In this study we wanted to get a better understanding of the function of CCN2/CTGF under normal and pathologic conditions. To this end, we analyzed the glial lamina and peripapillary sclera of CCN2/CTGF overexpressing mice and studied the effect of CCN2/CTGF and increasing substratum stiffness on murine ON astrocytes in vitro. We observed enhanced astrocyte reactivity in the ONH, increased ECM protein synthesis in the peripapillary sclera and increased Ccn2/Ctgf expression in the ONH during the pathologic development in situ. CCN2/CTGF treatment of primary murine ON astrocytes induced a higher migration rate, and increase of ECM proteins including fibronectin, elastin and collagen type III. Furthermore, the astrocytes responded to stiffer substratum with increased glial fibrillary acidic protein, vimentin, actin and CCN2/CTGF synthesis. Finally, we observed the reinforced appearance of CCN2/CTGF in the lamina cribrosa of glaucomatous patients. We conclude that reactive changes in ONH astrocytes, induced by the altered biomechanical characteristics of the region, give rise to a self-amplifying process that includes increased TGF-β2/CCN2/CTGF signaling and leads to the synthesis of ECM molecules and cytoskeleton proteins, a process that in turn augments the stiffness at the ONH. Such a scenario may finally result in a vicious circle in the pathogenesis of POAG. The transgenic CTGF-overexpressing mouse model might be an optimal model to study the chronic pathological POAG changes in the ONH.}, language = {en} } @article{SavelevGlavanBurdinetal., author = {Savelev, Dmitrii V. and Glavan, Gašper and Burdin, Dmitrii A. and Belyaeva, Inna A. and Fetisov, Leonid Y. and Shamonin (Chamonine), Mikhail and Fetisov, Yuri K.}, title = {Enhancement of magnetoelectric effect in polymer composites at low resonance frequencies by operation in the transverse-transverse mode}, series = {Journal of Magnetism and Magnetic Materials}, volume = {598}, journal = {Journal of Magnetism and Magnetic Materials}, publisher = {Elsevier}, issn = {1873-4766}, doi = {10.1016/j.jmmm.2024.172020}, abstract = {The resonant direct magnetoelectric (ME) effect for a series of multilayer heterostructures comprising a magnetoactive elastomer (MAE) of different thicknesses and a commercially available piezoelectric polyvinylidene fluoride-based vibration sensor has been investigated in detail. The specimens were rigidly fixed at one end as cantilevers. The cantilevers were operated in the transverse-transverse (T-T) mode, where both magnetic and electric fields were perpendicular to the plane of a non-deformed heterostructure. It is shown that the ME voltage coefficient of considered heterostructures in the T-T mode can be about 20-fold higher than in the conventional longitudinal-transverse (L-T) mode. The highest ME voltage coefficient reached about 150 V/(Oe·cm) at the first bending oscillation mode for the sample with MAE layer thickness of 4 mm. Mechanism of the resonant ME effect in T-T mode is explained using theory of critical bending of MAE cantilevers. Magnetic fields, when the ME voltage reaches its maximum, strongly depended on the MAE layer thickness, and could be associated with the critical field, where the structure commences to strongly bend. The non-monotonous dependence of the resonance frequency of the first oscillation mode on magnetic field strength was observed. The shift of the resonance frequency in the maximum magnetic field reached up to roughly 100 \% in comparison with zero field.}, language = {en} } @article{RoghaniRomeisGlavanetal., author = {Roghani, Mehran and Romeis, Dirk and Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail and Saphiannikova, Marina}, title = {Magnetically induced deformation of isotropic magnetoactive elastomers and its relation to the magnetorheological effect}, series = {Physical Review Applied}, volume = {23}, journal = {Physical Review Applied}, number = {3}, publisher = {American Physical Society (APS)}, issn = {2331-7019}, doi = {10.1103/PhysRevApplied.23.034041}, abstract = {Can isotropic magnetoactive elastomers (MAEs) undergo giant magnetically induced deformations and exhibit huge magnetorheological effects simultaneously? In this experimental and theoretical study, we reveal how the macroscopic deformation of MAEs relates to the process of particle restructuring caused by application of a magnetic field. For this purpose, MAE cylinders with different aspect ratios and particle loadings are studied in uniform magnetic fields. The axial deformations of the cylinders are acquired using an optical camera. A unified mean-field model proposed in previous studies is adapted to describe the transition of initially isotropic cylinders into transversely isotropic ones. This mechanical transition is caused by the rearrangement of particles into dense columnar structures aligned with the field and is believed to result in a huge magnetorheological effect. Our model however predicts less than a threefold increase in elastic moduli when evaluated along the field direction. This prediction is based on a careful examination of the shear moduli of studied MAEs and the columnar structures. A weak magnetorheological effect explains significant axial deformations measured in the field direction. A strong magnetorheological effect would hinder axial deformations due to an increase in the modulus by several orders of magnitude. Not only are the moduli and macroscopic deformations influenced by microstructure evolution, but so is the magnetization of particles, which increases as they rearrange into dense columns. With this study, we show that the unified mean-field model provides quantitative access to hidden material properties such as magnetization and stiffness in MAE samples with different shapes and evolving microstructures. Published by the American Physical Society 2025}, language = {en} } @misc{GlavanBelyaevaShamoninChamonine, author = {Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail}, title = {On the Piezomagnetism of Magnetoactive Elastomeric Cylinders in Uniform Magnetic Fields: Height Modulation in the Vicinity of an Operating Point by Time-Harmonic Fields [Data set]}, doi = {10.5281/zenodo.13834054}, language = {en} } @misc{GlavanBelyaevaShamoninChamonine, author = {Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail}, title = {Multiferroic Cantilevers Containing a Magnetoactive Elastomer: Magnetoelectric Response to Low-Frequency Magnetic Fields of Triangular and Sinusoidal Waveform [Data set]}, doi = {10.5281/zenodo.14651784}, language = {en} } @article{GlavanBelyaevaShamoninChamonine, author = {Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail}, title = {Multiferroic Cantilevers Containing a Magnetoactive Elastomer: Magnetoelectric Response to Low-Frequency Magnetic Fields of Triangular and Sinusoidal Waveform}, series = {Sensors}, volume = {22}, journal = {Sensors}, number = {10}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/s22103791}, pages = {1 -- 17}, abstract = {In this work, multiferroic cantilevers comprise a layer of a magnetoactive elastomer (MAE) and a commercially available piezoelectric polymer-based vibration sensor. The structures are fixed at one end in the horizontal plane and the magnetic field is applied vertically. First, the magnetoelectric (ME) response to uniform, triangle-wave magnetic fields with five different slew rates is investigated experimentally. Time and field dependences of the generated voltage, electric charge, and observed mechanical deflection are obtained and compared for four different thicknesses of the MAE layer. The ME responses to triangular and sinusoidal wave excitations are examined in contrast. Second, the ME response at low frequencies (≤3 Hz) is studied by the standard method of harmonic magnetic field modulation. The highest ME coupling coefficient is observed in the bias magnetic field strength of ≈73 kA/m and it is estimated to be about 3.3 ns/m (ME voltage coefficient ≈ 25 V/A) at theoretically vanishing modulation frequency (f→0 Hz). Presented results demonstrate that the investigated heterostructures are promising for applications as magnetic-field sensors and energy harvesting devices.}, language = {en} } @article{KrieglJezeršekKravanjaetal., author = {Kriegl, Raphael and Jezeršek, Matija and Kravanja, Gaia and Hribar, Luka and Mukhi, Soham and Kokot, Gašper and Drevenšek-Olenik, Irena and Shamonin (Chamonine), Mikhail}, title = {Tunable rebound of millimeter-sized rigid balls by magnetic actuation of elastomer-based surface microstructures}, series = {Smart Materials and Structures}, volume = {33}, journal = {Smart Materials and Structures}, number = {6}, publisher = {IOP Publishing}, doi = {10.1088/1361-665X/ad41a9}, abstract = {A novel method for controlling the rebound behavior of small balls made of Al2O3 with a radius of 2.381 mm is presented. It uses different types of micro-structured surfaces of soft magnetoactive elastomers. These surfaces were fabricated via laser micromachining and include fully ablated surfaces as well as micrometer-sized lamellas with a fixed width of 90 µm, height of 250 µm and three different gap sizes (15, 60 and 105 µm). The lamellas can change their orientation from edge-on to face-on configuration according to the direction of the external magnetic field from a permanent magnet. The orientation of the external magnetic field significantly influences the rebound behavior of the balls, from a coefficient of restitution e of to < 0.1. The highest relative change in the coefficient of restitution between zero field and face-on configuration of is observed for lamellas with a gap of 60 µm. Other characteristics of the ball rebound such as the penetration depth into an Magnetoactive elastomer and the maximum deceleration are investigated as well. The proposed method does not require a constant power supply due to the use of permanent magnets. It may find novel applications in the field of impact engineering.}, language = {en} } @misc{GlavanBelyaevaShamoninChamonineetal., author = {Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail and Ruwisch, Kevin and Wollschl{\"a}ger, Joachim}, title = {Magnetoelectric Response of Laminated Cantilevers Comprising a Magnetoactive Elastomer and a Piezoelectric Polymer, in Pulsed Uniform Magnetic Fields [Data set]}, doi = {10.5281/zenodo.14652152}, language = {en} } @misc{GlavanBelyaevaShamoninChamonine, author = {Glavan, Gašper and Belyaeva, Inna A. and Shamonin (Chamonine), Mikhail}, title = {Transient Response of Macroscopic Deformation of Magnetoactive Elastomeric Cylinders in Uniform Magnetic Fields [Data set]}, doi = {10.5281/zenodo.10679499}, language = {en} } @article{StrausKravanjaKriegletal., author = {Straus, Izidor and Kravanja, Gaia and Kriegl, Raphael and Shamonin (Chamonine), Mikhail and Drevenšek-Olenik, Irena and Jezeršek, Matija and Kokot, Gašper}, title = {Laser Micromachining for Polymer Surface Topography Designt}, series = {JoVE journal : engineering}, journal = {JoVE journal : engineering}, publisher = {JoVE}, doi = {10.3791/68126}, pages = {15}, abstract = {Soft magnetoactive elastomers (MAEs) are smart materials that respond to external magnetic fields by dynamically altering their mechanical properties. They are composed of magnetically responsive microparticles embedded within a soft polymer matrix, exhibiting an effective shear modulus of up to 100 kPa. In recent decades, MAEs' bulk properties have been successfully exploited for applications such as dynamic vibration damping, vibration sensing, and actuation in soft robotics. Recent research has shifted to their surface properties, revealing promising results on tunable surface features such as roughness, adhesion, and wetting. Even the transport of small solid and fluid objects was demonstrated. The associated surface effects can be significantly enhanced through the precise engineering of surface topography. In this article, an efficient laser micromachining technique, with a resolution of 15 µm, is presented, which enables rapid prototyping of MAE surfaces. It allows the creation of various complex shapes and offers functionality beyond the one achievable with traditional molding techniques. Additionally, the approach is versatile and can be applied to any polymer that sufficiently absorbs the laser light. As an example, a lamellar surface micro-pattern fabrication process and its characterization by optical and scanning electron microscopies are shown. Its response to a magnetic field is demonstrated. The technique provides a flexible and fast solution for optimizing polymer surface design across a wide range of applications.}, language = {en} }