@article{BurdinEkonomovChashinetal., author = {Burdin, Dmitrii A. and Ekonomov, Nikolai A. and Chashin, Dmitri V. and Fetisov, Leonid Y. and Fetisov, Yuri K. and Shamonin (Chamonine), Mikhail}, title = {Temperature Dependence of the Resonant Magnetoelectric Effect in Layered Heterostructures}, series = {Materials}, volume = {10}, journal = {Materials}, number = {10}, publisher = {MDPI}, doi = {10.3390/ma10101183}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-32185}, abstract = {The dependence of the resonant direct magnetoelectric effect on temperature is studied experimentally in planar composite structures. Samples of rectangular shapes with dimensions of 5 mm x 20 mm employed ferromagnetic layers of either an amorphous (metallic glass) alloy or nickel with a thickness of 20-200 m and piezoelectric layers of single crystalline langatate material or lead zirconate titanate piezoelectric ceramics with a thickness of 500 m. The temperature of the samples was varied in a range between 120 and 390 K by blowing a gaseous nitrogen stream around them. It is shown that the effective characteristics of the magnetoelectric effectsuch as the mechanical resonance frequency f(r), the quality factor Q and the magnitude of the magnetoelectric coefficient (E) at the resonance frequencyare contingent on temperature. The interrelations between the temperature changes of the characteristics of the magnetoelectric effect and the temperature variations of the following material parametersYoung's modulus Y, the acoustic quality factor of individual layers, the dielectric constant epsilon, the piezoelectric modulus d of the piezoelectric layer as well as the piezomagnetic coefficients ((n)) of the ferromagnetic layerare established. The effect of temperature on the characteristics of the nonlinear magnetoelectric effect is observed for the first time. The results can be useful for designing magnetoelectric heterostructures with specified temperature characteristics, in particular, for the development of thermally stabilized magnetoelectric devices.}, language = {en} } @article{FuhrmannMandlShamoninChamonine, author = {Fuhrmann, Thomas and Mandl, Roland and Shamonin (Chamonine), Mikhail}, title = {Analysis of learning improvement on changing lab course from single experiments to projects}, series = {International Journal of Electrical Engineering Education}, volume = {52}, journal = {International Journal of Electrical Engineering Education}, number = {4}, publisher = {SAGE}, doi = {10.1177/0020720915583863}, pages = {287 -- 297}, abstract = {During recent years, there has been a trend to replace traditional lab courses by project-based learning activities. However, there is currently little scientific evidence for educational improvements through such changes. Some years ago, a lab course on electrical measurements in our bachelor Electrical Engineering and Information Technology was modified from single experiments to projects. This change led to a significant increase in the necessary manpower and lab costs. To justify these higher efforts, it is important to investigate if the learning success increased. We carried out the surveys and collected the statistical data from the students who attended this course. In order to see if the students appreciated this lab course and if there was an objective increase of the students' knowledge, these results were evaluated. Evaluation of the grades in the lecture and lab courses shows that the increase of the students' theoretical and practical knowledge is statistically significant.}, language = {en} } @article{MayerRabindranathBoerneretal., author = {Mayer, Matthias and Rabindranath, Raman and B{\"o}rner, Juliane and H{\"o}rner, Eva and Bentz, Alexander and Salgado, Josefina and Han, Hong and B{\"o}se, Holger and Probst, J{\"o}rn and Shamonin (Chamonine), Mikhail and Monkman, Gareth J. and Schlunck, G{\"u}nther}, title = {Ultra-Soft PDMS-Based Magnetoactive Elastomers as Dynamic Cell Culture Substrata}, series = {PLoS ONE}, volume = {8}, journal = {PLoS ONE}, number = {10}, publisher = {PLOS}, doi = {10.1371/journal.pone.0076196}, abstract = {Mechanical cues such as extracellular matrix stiffness and movement have a major impact on cell differentiation and function. To replicate these biological features in vitro, soft substrata with tunable elasticity and the possibility for controlled surface translocation are desirable. Here we report on the use of ultra-soft (Young's modulus <100 kPa) PDMS-based magnetoactive elastomers (MAE) as suitable cell culture substrata. Soft non-viscous PDMS (<18 kPa) is produced using a modified extended crosslinker. MAEs are generated by embedding magnetic microparticles into a soft PDMS matrix. Both substrata yield an elasticity-dependent (14 vs. 100 kPa) modulation of α-smooth muscle actin expression in primary human fibroblasts. To allow for static or dynamic control of MAE material properties, we devise low magnetic field (≈40 mT) stimulation systems compatible with cell-culture environments. Magnetic field-instigated stiffening (14 to 200 kPa) of soft MAE enhances the spreading of primary human fibroblasts and decreases PAX-7 transcription in human mesenchymal stem cells. Pulsatile MAE movements are generated using oscillating magnetic fields and are well tolerated by adherent human fibroblasts. This MAE system provides spatial and temporal control of substratum material characteristics and permits novel designs when used as dynamic cell culture substrata or cell culture-coated actuator in tissue engineering applications or biomedical devices.}, language = {en} } @article{ForsterMayerRabindranathetal., author = {Forster, Eva and Mayer, Matthias and Rabindranath, Raman and B{\"o}se, Holger and Schlunck, G{\"u}nther and Monkman, Gareth J. and Shamonin (Chamonine), Mikhail}, title = {Patterning of ultrasoft, agglutinative magnetorheological elastomers}, series = {Journal of applied polymer science}, volume = {128}, journal = {Journal of applied polymer science}, number = {4}, publisher = {Wiley}, address = {New York, NY}, doi = {10.1002/app.38500}, pages = {2508 -- 2515}, abstract = {A low-cost wax-cast molding technique for structuring ultrasoft (Young's modulus ≤ 40 kPa), agglutinative magnetorheological elastomer (MRE) material is presented. MRE structures ranging from a few millimeters down to the micrometer range with highly reproducible results are possible. Semitransparent MREs are also fabricated and their surfaces modified accordingly. This method opens new possibilities for MREs in biomedical engineering and microfluidic applications. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013}, language = {en} } @article{KrieglKrenkelShamoninChamonine, author = {Kriegl, Raphael and Krenkel, Lars and Shamonin (Chamonine), Mikhail}, title = {Preservation of wetting ridges using field-induced plasticity of magnetoactive elastomers}, series = {Journal of Colloid and Interface Science}, volume = {683}, journal = {Journal of Colloid and Interface Science}, publisher = {Elsevier}, issn = {0021-9797}, doi = {10.1016/j.jcis.2024.12.132}, pages = {1019 -- 1027}, abstract = {Hypothesis. The presence of a wetting ridge is crucial for many wetting phenomena on soft substrates. Conventional experimental observations of a wetting ridge require permanent presence of a droplet. The magnetic field-induced plasticity effect (FIPE) of soft magnetoative elastomers (MAEs) allows one to overcome this limitation. Depositing a droplet onto an MAE surface and applying a magnetic field fixes the wetting ridge in place due to the FIPE. The droplet can be removed to investigate the ridge with ease using conventional optical methods. Experiments. The wetting ridge is observed on MAEs with different shear moduli and different material thicknesses by confocal laser scanning microscopy (LSM). The preservation quality of the ridge is analyzed for several values of magnetic field from 10 mT to 270 mT. To verify the plausibilty of results obtained, the measured shape is compared to a theoretical model by Style \& Dufresne. Findings. Upon removal of the sessile droplet, the deformation remains embossed onto the MAE surface as long as the magnetic field remains applied. The height of the ridge peak on soft samples (effective shear modulus kPa) is close to the theoretical prediction for a magnetic flux density of 50 mT. The magnitude of the external magnetic field magnifies the height of the wetting ridge.}, language = {en} } @article{StadlerHofmannMotschmannetal., author = {Stadler, Dominik and Hofmann, Matthias J. and Motschmann, Hubert and Shamonin (Chamonine), Mikhail}, title = {Automotived system for measuring the surface dilational modulus of liquid-air interfaces}, series = {Measurement Science and Technology}, volume = {27}, journal = {Measurement Science and Technology}, number = {6}, publisher = {IOP Science}, doi = {10.1088/0957-0233/27/6/065301}, pages = {065301}, abstract = {The surface dilational modulus is a crucial parameter for describing the rheological properties of aqueous surfactant solutions. These properties are important for many technological processes. The present paper describes a fully automated instrument based on the oscillating bubble technique. It works in the frequency range from 1 Hz to 500 Hz, where surfactant exchange dynamics governs the relaxation process. The originality of instrument design is the consistent combination of modern measurement technologies with advanced imaging and signal processing algorithms. Key steps on the way to reliable and precise measurements are the excitation of harmonic oscillation of the bubble, phase sensitive evaluation of the pressure response, adjustment and maintenance of the bubble shape to half sphere geometry for compensation of thermal drifts, contour tracing of the bubbles video images, removal of noise and artefacts within the image for improving the reliability of the measurement, and, in particular, a complex trigger scheme for the measurement of the oscillation amplitude, which may vary with frequency as a result of resonances. The corresponding automation and programming tasks are described in detail. Various programming strategies, such as the use of MATLAB® software and native C++ code are discussed. An advance in the measurement technique is demonstrated by a fully automated measurement. The instrument has the potential to mature into a standard technique in the fields of colloid and interface chemistry and provides a significant extension of the frequency range to established competing techniques and state-of-the-art devices based on the same measurement principle.}, language = {en} } @article{ShamoninChamonineShamoninaKalininetal., author = {Shamonin (Chamonine), Mikhail and Shamonina, Ekaterina and Kalinin, V. and Solymar, L.}, title = {Resonant frequencies of a split-ring resonator: Analytical solutions and numerical simulations}, series = {Microwave and optical technology letters}, volume = {44}, journal = {Microwave and optical technology letters}, number = {2}, publisher = {Wiley}, doi = {10.1002/mop.20567}, pages = {133 -- 136}, abstract = {A set of differential equations describing the current andvoltage distribution in a split-ring resonator is derived and solved ana-lytically. The resonant frequencies may be obtained from the solution of a characteristic equation. An approximate solution for the lowest reso-nant frequency agrees with that obtained by heuristic arguments. The analytical results are supported by numerical simulations}, language = {en} } @article{SnarskiiKalitaShamoninChamonine, author = {Snarskii, Andrei A. and Kalita, Viktor M. and Shamonin (Chamonine), Mikhail}, title = {Renormalization of the critical exponent for the shear modulus of magnetoactive elastomers}, series = {Scientific Reports}, volume = {8}, journal = {Scientific Reports}, publisher = {Nature}, doi = {10.1038/s41598-018-22333-6}, pages = {1 -- 8}, abstract = {It is shown that the critical exponent for the effective shear modulus of a composite medium where a compliant polymer matrix is filled with ferromagnetic particles may significantly depend on the external magnetic field. The physical consequence of this dependence is the critical behavior of the relative magnetorheological effect.}, language = {en} } @article{DillingerMayerSchneideretal., author = {Dillinger, Andrea Elisabeth and Mayer, Matthias and Schneider, Magdalena and Weber, Gregor R. and Goeppner, Corinna and Tamm, Ernst R. and Shamonin (Chamonine), Mikhail and Monkman, Gareth J. and Fuchshofer, Rudolf}, title = {Reactive changes in optic nerve astrocytes are mediated by CTGF, TGF beta 2 and increasing substratum stiffness}, series = {Investigative ophthalmology \& visual science}, volume = {56}, journal = {Investigative ophthalmology \& visual science}, number = {7}, publisher = {ASSOC RESEARCH VISION OPHTHALMOLOGY INC}, abstract = {Purpose: Patients with primary open-angle glaucoma (POAG) show a stiffer peripapillary sclera, reactive astrocytes and a remodeled lamina cribrosa (LC). The changes are thought to be mediated by TGFβ2 and its downstream mediator CTGF. Recently we developed a murine glaucoma model by overexpressing CTGF in the anterior eye (βb1CTGF). In this study we investigated the glial lamina region of βb1CTGF mice, and the changes of astrocytes in response to CTGF and TGFβ2 as well as increasing substratum stiffness. Methods: Tangential sections of the glial LC of 2-month-old βb1CTGF mice and their wild-type littermates (WT) were stained with phalloidin and antibodies against GFAP, CTGF and fibronectin (FN). Murine optic nerve (ON) astrocytes from CD1 mice were isolated, cultured and characterized by GFAP staining. The astrocytes were treated with TGFβ2 (1ng/ml) and CTGF (50ng/ml and 100ng/ml). In addition, the cells were seeded on PDMS substrata with different stiffness (10, 30 and 60 kPa). Treated cells were analyzed by Western blotting, real-time RT-PCR and immunohistochemistry. Wound healing assays were performed to analyze migration rate following growth factor treatment. Results: βb1CTGF mice showed a massive increase in CTGF and GFAP in the glial LC when compared with WT mice. Moreover, an increase in FN staining and phalloidin-labeled actin was observed in the peripapillary sclera. Murine ON astrocytes reacted on increased substrate stiffness by increasing the synthesis of GFAP, vimentin and CTGF. Treatment of the cells with TGFβ2 and CTGF led to an enhanced migration rate. In addition, treatment resulted in an increased expression and synthesis of ECM proteins, including FN, tropoelastin, collagen type I and III. The in vitro findings correlated with those seen in the glaucoma mouse model. Conclusions: We conclude that changes in the ECM of LC and peripapillary sclera alter their biomechanical properties and thereby induce reactive changes in resident astrocytes. The reactive changes induced by higher stiffness of their surrounding ECM give rise to a self-amplifying process that includes increased TGFβ2/CTGF signaling and leads to synthesis of ECM and cytoskeletal proteins, a process that in turn augments the stiffness at the optic nerve head (ONH). Such a scenario may finally result in a vicious circle as the causative mechanism for ONH deformation in POAG.}, language = {en} } @article{SnarskiiZhenirovskyyShamoninChamonine, author = {Snarskii, Andrei A. and Zhenirovskyy, M. I. and Shamonin (Chamonine), Mikhail}, title = {The effective properties of macroscopically nonuniform ferromagnetic composites: Theory and numerical experiment}, series = {Journal of Experimental and Theoretical Physics}, volume = {96}, journal = {Journal of Experimental and Theoretical Physics}, publisher = {Springer}, doi = {10.1134/1.1545385}, pages = {66 -- 77}, abstract = {Various theoretical models (self-consistent field, local linearization, and percolation theory methods and an analytic solution of the linear problem for an ordered medium) for calculating the magnetostatic properties of two-phase composites containing one ferromagnetic phase were considered. The concentration and field dependences of the effective magnetic permeability were found. A method for determining the coercive force and remanent magnetization as functions of the ferromagnetic phase concentration was suggested. Numerical experiments were performed for composites with a periodic distribution of circular inclusions. The results were compared with the analytically calculated effective magnetic permeability.}, language = {en} }