@article{BachmannDuesbergLangeretal., author = {Bachmann, Michael and D{\"u}sberg, Felix and Langer, Christoph and Herdl, Florian and Bergbreiter, Lukas and Dams, Florian and Miyakawa, Natuski and Eggert, Tobias and Pahlke, Andreas and Edler, Simon and Prommesberger, Christian and Ławrowski, Robert Damian and Hausladen, Matthias and Schreiner, Rupert}, title = {Vacuum-sealed field emission electron gun}, series = {Journal of Vacuum Science \& Technology B}, volume = {38}, journal = {Journal of Vacuum Science \& Technology B}, number = {2}, publisher = {AIP Publishing}, doi = {10.1116/1.5139316}, abstract = {A compact vacuum-sealed field emission electron gun with an operation voltage below 5 kV is presented. With a 150 nm thick pyrolytic carbon membrane, a transmission of 40\% at 5 kV is obtained. For more than 2500 h of continuous operation at an emission current of 100 nA, no significant increase (<50V ) and almost no degradation were found. From this measurement, a lifetime of more than 10 000 h at continuous operation with approximately a linear increase of the extraction voltage from about 545 V to about 730 V is predicted. This electron source enables application of field emitter arrays in poor vacuum or even ambient pressure. ACKNOWLEDGMENT This work was supported by the German Federal Ministry for Economic Affairs and Energy under Project No. ZF4081502GM8. C.P., R.L., M.H., and R.S. were supported by Grant No. ZF4562901GM8.}, language = {en} }