@article{FrazzicaPalombaDawoudetal., author = {Frazzica, Andrea and Palomba, Valeria and Dawoud, Belal and Gull{\`i}, Giuseppe and Brancato, Vincenza and Sapienza, Alessio and Vasta, Salvatore and Freni, Angelo and Costa, Fabio and Restuccia, Giovanni}, title = {Design, realization and testing of an adsorption refrigerator based on activated carbon/ethanol working pair}, series = {Applied Energy}, volume = {174}, journal = {Applied Energy}, publisher = {Elsevier}, doi = {10.1016/j.apenergy.2016.04.080}, pages = {15 -- 24}, abstract = {In the present paper design, realization and testing of a novel small scale adsorption refrigerator prototype based on activated carbon/ethanol working pair is described. Firstly, experimental activity has been carried out for identification of the best performing activated carbon available on the market, through the evaluation of the achievable thermodynamic performance both under air conditioning and refrigeration conditions. Once identified the best performing activated carbon, the design of the adsorber was developed by experimental dynamic performance analysis, carried out by means of the Gravimetric-Large Temperature Jump (G-LTJ) apparatus available at CNR ITAE lab. Finally, the whole 0.5 kW refrigerator prototype was designed and built. First experimental results both under reference air conditioning and refrigeration cycles have been reported, to check the achievable performance. High Specific Cooling Powers (SCPs), 95 W/kg and 50 W/kg, for air conditioning and refrigeration respectively, were obtained, while the COP ranged between 0.09 and 0.11, thus showing an improvement of the current state of the art. (C) 2016 Elsevier Ltd. All rights reserved.}, language = {en} } @article{ChatzitakisDawoud, author = {Chatzitakis, Paris and Dawoud, Belal}, title = {An alternative approach towards absorption heat pump working pair screening}, series = {Renewable Energy}, volume = {110}, journal = {Renewable Energy}, publisher = {Pergamon-Elsevier}, organization = {PERGAMON-ELSEVIER SCIENCE LTD}, doi = {10.1016/j.renene.2016.08.014}, pages = {47 -- 58}, abstract = {The successful market penetration of modern absorption heat pumps (AHP) today is critically dependent on their thermodynamic performance as well as other key factors like cost, reliability and inherent safety. Conventional AHPs have a proven record in the first two aspects but crucial shortcomings in the last two. For this reason it has been imperative to search for alternative working pairs that could potentially provide comparable performance while also satisfying the rest of the conditions to the best extent possible. As part of a systematic approach towards this direction, a detailed cycle analysis was performed, utilizing an idealized AHP system containing a real working pair, which enabled the identification of five dimensionless parameters and key thermophysical properties that influence the system's thermodynamic efficiency and the circulation ratio. In order to validate those findings, these parameters were calculated and compared between conventional and alternative AHP refrigerants. It turned out that low molecular weight ratios between absorbent and refrigerant have a beneficial effect on both coefficient of performance and the circulation ratio. Furthermore, both the refrigerant acentric factor and the absorbent vaporization enthalpy shall be minimized to obtain better performance. (C) 2016 Elsevier Ltd. All rights reserved.}, language = {en} } @article{Dawoud, author = {Dawoud, Belal}, title = {On the development of an innovative gas-fired heating appliance based on a zeolite-water adsorption heat pump; system description and seasonal gas utilization efficiency}, series = {Applied Thermal Engineering}, volume = {72}, journal = {Applied Thermal Engineering}, number = {2}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2014.09.008}, pages = {323 -- 330}, abstract = {The main objective of this work is to introduce an innovative hybrid heating appliance incorporating a gas condensing boiler and a zeolite-water adsorption heat pump. The condensing boiler is applied to drive the zeolite-water heat pump for the heating base-load and to assist the heat pump in the so called "mixed operation" mode, in which both the heat pump and the condensing boiler are working in series to cover medium heating demands. Peak heating demands are covered by the condensing boiler in the so called "direct heating" mode. The three operation modes of the hybrid heating appliance have been technically described. In addition, the laboratory test conditions for estimating the seasonal heating performance according to the German Guideline VDI 4650-2 have been introduced. For both heating systems 35/28 °C and 55/45 °C, which represent the typical operating conditions of floor and high temperature radiating heating systems in Europe, seasonal heating gas utilization efficiencies of 1.34 and 1.26 have been measured, respectively with a ground heat source. In two field test installations in one-family houses in Germany, the introduced heating appliance showed 27\% more seasonal gas utilization efficiency for heating and domestic hot water production, which is equivalent to a CO2-emission reduction of 20\% compared to the gas condensing boiler technology.}, language = {en} } @article{PalombaDawoudSapienzaetal., author = {Palomba, Valeria and Dawoud, Belal and Sapienza, Alessio and Vasta, Salvatore and Frazzica, Andrea}, title = {On the impact of different management strategies on the performance of a two-bed activated carbon/ethanol refrigerator: An experimental study}, series = {Energy conversion and management}, volume = {142}, journal = {Energy conversion and management}, publisher = {Elsevier}, doi = {10.1016/j.enconman.2017.03.055}, pages = {322 -- 333}, abstract = {In the present work, an experimental study on a lab-scale adsorption refrigerator, based on activated carbon/ethanol working pair is reported. An extensive testing campaign has been carried out at the CNR ITAE laboratory, with multiple aims. First, the performance has been evaluated in terms of both COP and Specific Cooling Power (SCP), under different boundary conditions, including both air conditioning and refrigeration applications. Attractive SCPs, up to 180 W/kg and 70 W/kg for air conditioning and refrigeration, respectively, were measured. Under the same conditions, COP between 0.17 and 0.08 were obtained. In addition, different management strategies, namely, heat recovery between adsorbers and re-allocation of phase durations, were evaluated to identify their influence on the system. Both strategies confirmed the possibility of increasing COP and SCP up to 40\% and 25\%, respectively. Moreover, a design analysis based on the experimental results has been carried out, to suggest possible improvements of the system. The obtained results demonstrated the possibility of employing a non-toxic refrigerant like ethanol reaching performance comparable with other harmful refrigerants like ammonia and methanol. (C) 2017 Elsevier Ltd. All rights reserved.}, language = {en} } @article{ProverbioCalabreseCaprietal., author = {Proverbio, Edoardo and Calabrese, Luigi and Capri, Angela and Bonaccorsi, Lucio Maria and Dawoud, Belal and Frazzica, Andrea}, title = {Susceptibility to corrosion of aluminium alloy components in ethanol adsorption chiller}, series = {Renewable energy}, volume = {110}, journal = {Renewable energy}, publisher = {Elsevier}, doi = {10.1016/j.renene.2016.08.042}, pages = {174 -- 179}, abstract = {Methanol, and more recently ethanol, have been deeply employed as adsorbate phase (refrigerant) in adsorption chiller and heat pump applications (e.g. refrigerator adsorption ice maker). The use of anhydrous alcohols however can cause several problems related to the corrosiveness of such molecules towards light alloys (from titanium to aluminium). The problem was already highlighted in bio-fuel technology where bio-ethanol was considered as a promise alternative to fossil hydrocarbons. Water content was observed as one of the main factors influencing corrosion rate. In the present works several accelerated corrosion tests on 6061 Aluminium alloy have been carried out in autoclave in a temperature range from 110 to 135 degrees C with different ethanol to aluminium mass ratio. Highly exothermic reactions related to aluminium oxidation, coupled to hydrogen evolution, have been recorded. The main drawback of hydrogen evolution is the formation of a stagnant layer over the heat exchangers surface, which can limit the ethanol vapour diffusion, thus reducing adsorption condensation rate. (C) 2016 Elsevier Ltd. All rights reserved.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental Investigation of the Adsorption and Desorption Kinetics on an Open-Structured Asymmetric Plate Heat Exchanger; Matching Between Small-Scale and Full-Scale Results}, series = {Frontiers in Energy Research}, volume = {10}, journal = {Frontiers in Energy Research}, publisher = {Frontiers}, doi = {10.3389/fenrg.2022.818486}, pages = {1 -- 15}, abstract = {This paper introduces the results of an experimental study on the adsorption and desorption kinetics of a commercially available, open-structured asymmetric plate heat exchanger adapted to act as an adsorber/desorber for the application in adsorption heat transformation processes. In addition, a volumetric large temperature jump (V-LTJ) kinetic setup was applied to measure the adsorption and desorption kinetics of a small-scale adsorbent sample prepared dedicatedly to be representative for the adsorbent domain inside the investigated adsorber plate heat exchanger (APHE). All kinetic results of the small-scale adsorbent sample and the APHE were fitted into exponential forms with a single characteristic time constant (τ) with a coefficient of determination (R2) better than 0.9531. A very good matching between the small-scale and full-scale adsorption kinetic measurements was obtained, with an average relative deviation of 12.3\% in the obtained τ-values. In addition, the kinetic data of the small-scale adsorbent sample were utilized for estimating the expected specific instantaneous and moving average powers of the evaporator/condenser heat exchanger. The average relative deviation (ARD) between the moving average specific evaporator powers obtained from the small-scale and the full-scale measurements amounts between 5.4 and 15.1\%.}, language = {en} } @article{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Assessment of the Annual Transmission Heat Loss Reduction of a Refurbished Existing Building with an Advanced Solar Selective Thermal Insulation System}, series = {Sustainability}, volume = {13}, journal = {Sustainability}, number = {13}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/su13137336}, pages = {1 -- 19}, abstract = {A numerical parameter sensitivity analysis of the design parameters of the recently published solar selective thermal insulation system (SATIS) has been carried out to enhance its thermal and optical properties. It turned out that the insulation properties of SATIS can be effectively improved by reducing the length of the glass closure element. Increasing the area share of the light conducting elements (LCEs) and decreasing their length-to-diameter (L/D) ratio were identified as key parameters in order to increase the solar gain. Two SATIS variants were compared with the same wall insulation without SATIS in a yearly energetic performance assessment. The SATIS variant with 10 mm length of the closure element, 44.2\% area share of LCE, as well as front and rear diameters of 12 mm/9 mm shows an 11.8\% lower transmission heat loss over the heating period than the wall insulation without SATIS. A new methodology was developed to enable the implementation of the computed solar gains of SATIS in 1D simulation tools. The result is a radiant heat flow map for integration as a heat source in 1D simulation models. A comparison between the 1D and 3D models of the inside wall heat fluxes showed an integral yearly agreement of 98\%.}, language = {en} } @article{VerezBorriCrespoetal., author = {V{\´e}rez, David and Borri, Emiliano and Crespo, Alicia and Zsembinszki, Gabriel and Dawoud, Belal and Cabeza, Luisa F.}, title = {Experimental Study of a Small-Size Vacuum Insulated Water Tank for Building Applications}, series = {Sustainability}, volume = {13}, journal = {Sustainability}, number = {10}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/su13105329}, pages = {1 -- 11}, abstract = {Insulation of thermal energy storage tanks is fundamental to reduce heat losses and to achieve high energy storage efficiency. Although water tanks were extensively studied in the literature, the enhancement of the insulation quality is often overlooked. The use of vacuum insulation has the potential to significantly reduce heat losses without affecting the dimension of the storage system. This paper shows for the first time the results of the heat losses tests done for a 0.535 m3 water tank for residential building applications built with a double wall vacuum insulation. The different tests show that the rate of heat losses strictly depends on the temperature distribution inside the tank at the beginning of the experiment. Compared to a conventional water tank insulated with conventional materials, the U-value of the lateral surface was reduced by almost three times (from 1.05 W/K·m2 to 0.38 W/K·m2) using vacuum insulation. However, the bottom part, which is usually used to place the support parts and the piping, is the critical design part of those tanks acting as a thermal bridge with the ambient and enhancing heat losses.}, language = {en} } @article{GamischGadererDawoud, author = {Gamisch, Bernd and Gaderer, Matthias and Dawoud, Belal}, title = {On the Development of Thermochemical Hydrogen Storage: An Experimental Study of the Kinetics of the Redox Reactions under Different Operating Conditions}, series = {Applied Sciences}, volume = {11}, journal = {Applied Sciences}, number = {4}, publisher = {MDPI}, address = {Basel}, doi = {10.3390/app11041623}, pages = {1 -- 15}, abstract = {This work aims at investigating the reduction/oxidation (redox) reaction kinetics on iron oxide pellets under different operating conditions of thermochemical hydrogen storage. In order to reduce the iron oxide pellets (90\% Fe2O3, 10\% stabilizing cement), hydrogen (H2) is applied in different concentrations with nitrogen (N2), as a carrier gas, at temperatures between between 700 ∘C and 900 ∘C, thus simulating the charging phase. The discharge phase is triggered by the flow of a mixture out of steam (H2O) and N2 at different concentrations in the same temperature range, resulting in the oxidizing of the previously reduced pellets. All investigations were carried out in a thermo-gravimetric analyzer (TGA) with a flow rate of 250mL/min. To describe the obtained kinetic results, a simplified analytical model, based on the linear driving force model, was developed. The investigated iron oxide pellets showed a stable redox performance of 23.8\% weight reduction/gain, which corresponds to a volumetric storage density of 2.8kWh/(L bulk), also after the 29 performed redox cycles. Recalling that there is no H2 stored during the storage phase but iron, the introduced hydrogen storage technology is deemed very promising for applications in urban areas as day-night or seasonal storage for green hydrogen.}, language = {en} } @article{GeilfussDawoud, author = {Geilfuß, Kristina and Dawoud, Belal}, title = {Analytical investigation of a zeolite-NaY-water adsorption heat and cold storage and its integration into a steam power process}, series = {Energy}, volume = {195}, journal = {Energy}, number = {March}, publisher = {Elsevier}, doi = {10.1016/j.energy.2020.116977}, abstract = {tabilizing the effects of greenhouse gas emissions on the atmosphere is a key step towards solving the global climate change problems. Storage technologies play an essential role in compensating the discrepancy between surplus energy and peak times. Sorption processes, in particular, offer an environment friendly way for almost loss-free heat (of adsorption or absorption) and cold storage. This work is dedicated first to analytically investigate the potential of applying NaY-Water/Zeolite as a working pair for heat and cold storage upon utilizing high temperature heat. It turned out that, the mass of the adsorber heat exchanger increases the useful specific heat stored from 229 kWh/tzeolite for the ideal storage to 538 kWh/tzeolite or even higher depending on the thermal capacity of the adsorber heat exchanger (AdsHX). Contrary to that trend, COP will decrease with increasing the thermal capacity of the AdsHX. Sensible heat losses between charging and discharging phases do have a negative effect on both stored heating capacity and COP. In addition, an innovative hybrid steam power cum adsorption storage process is introduced and analytically investigated at different ambient conditions and time scenarios for on-peak and off-peak durations over the day. The introduced hybrid process seems quite promising in achieving electrical power production and efficiency enhancements during peak load durations. The extent of enhancing both performance indicators increases with increasing the ambient temperature difference between peak and off-peak times.}, language = {en} } @article{FrazzicaBrancatoDawoud, author = {Frazzica, Andrea and Brancato, Vincenza and Dawoud, Belal}, title = {Unified Methodology to Identify the Potential Application of Seasonal Sorption Storage Technology}, series = {Energies}, volume = {13}, journal = {Energies}, number = {5}, publisher = {MPDI}, address = {Basel}, doi = {10.3390/en13051037}, pages = {1 -- 17}, abstract = {In this study, the definition of a new methodology for a preliminary evaluation of the working boundary conditions under which a seasonal thermal energy storage (STES) system operates is described. The approach starts by considering the building features as well as the reference heating system in terms of solar thermal collectors' technology, ambient heat sinks/source, and space heating distribution systems employed. Furthermore, it is based on a deep climatic analysis of the place where the STES needs to be installed, to identify both winter and summer operating conditions. In particular, the STES energy density is evaluated considering different space heating demands covered by the STES (ranging from 10\% up to 60\%). The obtained results demonstrate that this approach allows for the careful estimation of the achievable STES density, which is varies significantly both with the space heating coverage guaranteed by the STES as well as with the ambient heat source/sink that is employed in the system. This confirms the need for careful preliminary analysis to avoid the overestimation of the STES material volume. The proposed approach was then applied for different climatic conditions (e.g., Germany and Sweden) and the volume of one of the most attractive composite sorbent materials reported in the literature, i.e., multi-wall carbon nanotubes (MWCNT)-LiCl, using water as the working fluid, needed for covering the variable space heating demand in a Nearly Zero Energy Building (NZEB) was calculated. In the case of Swedish buildings, it ranges from about 3.5 m3 when 10\% of the space heating demand is provided by the STES, up to 11.1 m3 when 30\% of the space heating demand is provided by the STES.}, language = {en} } @book{FreniDawoudBonaccorsietal., author = {Freni, Angelo and Dawoud, Belal and Bonaccorsi, Lucio Maria and Chmielewski, Stefanie and Frazzica, Andrea and Calabrese, Luigi and Restuccia, Giovanni}, title = {Characterization of Zeolite-Based Coatings for Adsorption Heat Pumps}, publisher = {Springer}, address = {Berlin}, doi = {10.1007/978-3-319-09327-7}, pages = {96 S.}, abstract = {This book proposes a radically new approach for characterizing thermophysical and mechanical properties of zeolite-based adsorbent coatings for Adsorptive Heat Transformers (AHT). It presents a developed standard protocol for the complete characterization of advanced coated adsorbers. Providing an in-depth analysis of the different procedures necessary for evaluating the performance of adsorbers, it also presents an analysis of their stability under the hydrothermal and mechanical stresses during their entire life cycle. Adsorptive Heat Transformers (AHT), especially adsorption chillers and heat pumps, are considered to be promising technologies to increase thermal energy efficiency. Nevertheless, an overall increase in performance of this apparatus is necessary for them to be considered a mature technology to be used commercially. Development of innovative coated adsorbers can be perceived as a key issue for the enhancement of AHT technology. This procedure relies on the deposition, either by means of a binder or by direct crystallization, of the adsorbent material over a metallic heat exchanger, aiming at the improvement of the heat transfer between the external heat source and the adsorbent itself. This book offers a valuable resource to those working on the development of novel adsorbent materials and advanced adsorbent beds for heating and cooling applications. It is also intended for researchers interested in renewable energy and energy efficiency.}, language = {en} } @article{ChatzitakisSafarovOpferkuchetal., author = {Chatzitakis, Paris and Safarov, Javid and Opferkuch, Frank and Dawoud, Belal and Hassel, Egon}, title = {Vapor pressures and activity coefficients of 2,2,2-trifluoroethanol in binary mixtures with 1,3-dimethyl-2-imidazolidinone and 2-pyrrolidone}, series = {Journal of Molecular Liquids}, volume = {305}, journal = {Journal of Molecular Liquids}, number = {May}, publisher = {Elsevier}, issn = {0167-7322}, doi = {10.1016/j.molliq.2020.112828}, abstract = {The vapor pressures of two binary mixtures containing 2-trifluoroethanol (TFE) + 1,3-dimethyl-2-imidazolidinone (DMI) and TFE + 2-pyrrolidone (PYR), were investigated at temperatures T = (274.15 to 423.15) K using two different static method installations. Both combinations were modelled using an extended Clausius-Clapeyron equation with concentration dependent parameters and the NRTL equation with temperature dependent parameters. The best fit was obtained using the NRTL equation.}, language = {en} } @article{ChatzitakisSafarovOpferkuchetal., author = {Chatzitakis, Paris and Safarov, Javid and Opferkuch, F. and Dawoud, Belal}, title = {Experimental investigation of an absorption heat pump with organic working pairs}, series = {Applied Thermal Engineering}, volume = {163}, journal = {Applied Thermal Engineering}, number = {December}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2019.114311}, abstract = {As part of a systematic approach towards the search for alternative absorption heat pump (AHP) working pairs that could potentially provide comparable performance to conventional ones, a previous work performed a detailed theoretical cycle analysis and simulation that revealed concrete correlations between key working fluid thermophysical properties and AHP performance indicators. Following this work, targeted combinations of two organic refrigerants, 2,2,2-trifluoroethanol (TFE) and 2,2,3,3,3-pentafluoropropanol (5FP) and two organic absorbents, 1,3-dimethyl-2-imidazolidinone (DMI) and 2-pyrrolidone (PYR) were tested in a prototype 5 kW AHP, based on a highly compact plate heat exchanger design, which has been previously introduced. The purpose of this effort was to test the findings of the previous work with experimental measurements. The working pair combinations were also subjected to vapor liquid equilibrium (VLE) and viscosity measurements, in order to determine reliable activity coefficient and improve the accuracy of the simulations. The experimental performance data agree well with the COP simulations and show to be consistent with the conclusions derived from the previous theoretical work.}, language = {en} } @article{SteiningerGadererDawoudetal., author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal and Gaderer, Matthias}, title = {Experimental and numerical study on the solar gain and heat loss of typical existing and refurbished German buildings}, series = {iCRBE Procedia}, volume = {1}, journal = {iCRBE Procedia}, number = {1}, publisher = {Weentech}, doi = {10.32438/icrbe.202035}, pages = {75 -- 93}, abstract = {This communication introduces an experimental setup for investigating the effect of solar radiation on the reduction of transmission heat losses and the steady state thermal conductance of uninsulated and insulated multi-layer wall samples. The setup consists of two adjacent climatic chambers, which share a common wall, in which the multi-layer wall samples are mounted. A solar simulator is applied within the outdoor air climatic chamber, whose radiation spectrum and radiation intensity are approximately equivalent to those of the sun. The first tests have been carried out on a wall sample with a typical structure of existing buildings from the year 1930 in Germany. In addition, a high-performance insulating plaster layer has been applied on a basic test sample (with existing building structure) to replicate and assess the refurbished scenario. Furthermore, a numerical investigation on the transient heat transfer process is carried out by using the simulation software COMSOL Multiphysics®. The experimental results of both uninsulated and insulated wall samples are validated against 1D and 3D models. As seen, the uninsulated wall, whose thermal conductance was experimentally determined to be equal to 1.79 W/(m²K), absorbs a heat flux of 208 W/m² through its external wall surface over a period of 8 hours. A fraction of 9.8 \% of the absorbed heat arrives as a gain on the internal wall and reduces the transmission heat losses by 11.7 \% over a period of 55 hours. On the other hand, the thermal conductivity of the insulation layer of the refurbished wall sample with micro hollow glass spheres was estimated by a parameter estimation procedure using the 3D model and the obtained experimental data. Using the estimated thermal conductivity, a thermal conductance of 0.42 W/(m²K) has been obtained for the refurbished wall sample.}, language = {en} } @article{SteiningerGadererSteffensetal., author = {Steininger, Peter and Gaderer, Matthias and Steffens, Oliver and Dawoud, Belal}, title = {Experimental and Numerical Study on the Heat Transfer Characteristics of a Newly-Developed Solar Active Thermal Insulation System}, series = {Buildings}, volume = {11}, journal = {Buildings}, number = {3}, publisher = {MDPI}, doi = {10.3390/buildings11030123}, pages = {1 -- 22}, abstract = {A newly-developed solar active thermal insulation system (SATIS) is introduced with the main objective to accomplish a highly-dependent total solar transmittance on the irradiation angle. SATIS is also designed to obtain the maximum transmittance at a prescribed design irradiation angle and to reduce it remarkably at higher irradiation angles. A purely mineral thermal insulation plaster with micro hollow glass spheres is applied to manufacture the investigated SATIS prototype. Light-conducting elements (LCEs) have been introduced into SATIS and suitable closing elements have been applied. The SATIS prototype has been investigated both experimentally and numerically. It turned out that the contributions of conduction, radiation and convection to the effective thermal conductivity of SATIS, without the closing elements (49 mWmK), amount to 86.2\%, 13.2\% and 0.6\%, respectively. The angle-dependent short-wave radiation exchange within the LCE has been investigated via ray tracing. At the incidence angle of 19\% (design angle), 27\% of the radiation within the LCE is absorbed by the absorber plate, resulting in measured and computed total solar energy transmittances of 11.2\%/11.7\%, respectively. For a typical summer irradiation angle of 60\%, 98\% of the incident radiation is absorbed by the surfaces at the entrance of the LCE. The corresponding total solar energy transmittance amounts to 2.9\%.}, language = {en} } @article{SalamaKouDawoudetal., author = {Salama, Amgad and Kou, Jisheng and Dawoud, Belal and Rady, Mohamed and El Morshedy, Salah}, title = {Investigation of the self-propulsion of a wetting/nonwetting ganglion in tapered capillaries with arbitrary viscosity and density contrasts}, series = {Colloids and Surfaces A: Physicochemical and Engineering Aspects}, volume = {664}, journal = {Colloids and Surfaces A: Physicochemical and Engineering Aspects}, publisher = {Elsevier}, issn = {0927-7757}, doi = {10.1016/j.colsurfa.2023.131151}, abstract = {The movement of a meniscus inside a capillary tube has been extensively studied in the context of displacing one fluid with another immiscible one. This phenomenon exists in many applications including pharmaceutical, oil production, filtration and separation processes, and others. When one of the phases is entrapped inside a capillary tube, it forms what is called a ganglion with two menisci between the two fluids. In a straight uniform capillary tube, a stagnant entrapped ganglion is symmetric. The situation is different if the capillary tube is tapered in which case the two menisci assume different curvatures. Such inhomogeneity of the capillary pressure self-propels the ganglion to move. The fate of the ganglion inside the tapered tube depends on whether it is wetting or nonwetting to the tube wall. That is, after the initial movement, a wetting ganglion accelerates towards the tapered end of the tube while a nonwetting one decelerates towards the wider end before reaching a terminal configuration. Such fates are linked to the variations of the capillary pressure, which continuously increases for a wetting ganglion and decreases for the nonwetting one. In this work, a generalized model is developed that not only describes capillary-driven dynamics over a wide range of viscosity and density contrasts but also pressure-driven scenarios with/without gravity. The model, however, neglects the inertial effect of the two fluids on account of the fact that it is confined to the very early time of the movement process. A first-order nonlinear ordinary differential equation is developed that describes the dynamic behavior of both the wetting and nonwetting ganglions. A fourth-order Runge-Kutta algorithm is developed to solve the model equations. Furthermore, a computational fluid dynamics (CFD) analysis was used to provide a comparison and verification framework.}, language = {en} } @inproceedings{SteiningerGadererDawoud, author = {Steininger, Peter and Gaderer, Matthias and Dawoud, Belal}, title = {Transient performance of a solar selective thermal insulation system}, series = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, booktitle = {16th Advanced Building Skins Conference \& Expo, 21 - 22/10/2021, Bern, Switzerland}, publisher = {Advanced Buidling Skins GmbH}, abstract = {A prototype of a thermal insulation system to offer high selectivity of the solar gain regarding the solar incidence angle (SATIS) was applied to a typical solid brick masonry for existing buildings in Germany. Light conducting elements (LCEs) inclined at 19 ° were incorporated in SATIS, which equals the average solar noon angle in southern Germany during winter. The entire wall construction was experimentally investigated in a differential climatic chamber test bench at four different irradiation angles according to a dynamic test procedure. In addition, a conventional wall construction (CWC) has been measured. At SATIS' design angle of 19 °, the SATIS wall construction shows a solar gain (SG) of 394.5 Wh/m², while the SG of the CWC amounts to only 25.4 Wh/m². The validated transient model of the SATIS wall construction showed that, at the end of the irradiation period of the dynamic test procedure (8 h), the solar heat penetrates to a depth of 253 mm and 111 mm inside the 385 mm thick brick wall masonry at the irradiation angles of 19 ° and 50 °, respectively. During the same time, the stored solar energy at 50 ° amounts to only 24.4 \% of that stored at 19 °.}, language = {en} } @article{FreniFrazzicaDawoudetal., author = {Freni, Angelo and Frazzica, Andrea and Dawoud, Belal and Chmielewski, Stefanie and Calabrese, Luigi and Bonaccorsi, Lucio Maria}, title = {Adsorbent coatings for heat pumping applications: Verification of hydrothermal and mechanical stabilities}, series = {Applied Thermal Engineering}, volume = {50}, journal = {Applied Thermal Engineering}, number = {2}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2011.07.010}, pages = {1658 -- 1663}, abstract = {This paper presents novel experimental methods for verification of both hydrothermal and mechanical stabilities of adsorbent coatings. Experiments have been carried out on zeolite-based coatings over aluminum substrates, prepared by a dip-coating technique developed at CNR-ITAE. Hydrothermal aging of several adsorbent coatings is ongoing. Adsorption and structural stability of some samples under test was successfully verified after 35000 aging cycles by isobars measurement and XRD analysis. Mechanical properties of coatings have been evaluated by applying different typologies of static and dynamic mechanical stresses. Results obtained have been compared with those achieved by subjecting adsorbent coatings prepared by Mitsubishi Plastic Incorporation (MPI) to the same characterization protocol. The comparison between the two types of coating returned that MPI coatings posses similar thermal stability and better mechanical strength than CNR-ITAE coatings.}, language = {en} } @article{Dawoud, author = {Dawoud, Belal}, title = {Water vapor adsorption kinetics on small and full scale zeolite coated adsorbers; A comparison}, series = {Applied thermal engineering}, volume = {50}, journal = {Applied thermal engineering}, number = {2}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2011.07.013}, pages = {1645 -- 1651}, abstract = {A possibility to enhance both heat and mass transfer characteristics of an adsorber heat exchanger is to apply the adsorbent directly to its surface in form of a consolidated layer. As the majority of the available publications on the effect of both coating technology and adsorbent layer thickness on the adsorption kinetics deals with small scale adsorbent samples, the results obtained can only represent the best case design of an adsorber heat exchanger. This article presents, therefore, a comparison between the adsorption kinetics of water vapour on small as well as two different full scale coated adsorber heat exchanger types with AQSOA-Z02 layers of Mitsubishi Plastics Incorporation under quasi isobaric conditions of adsorption heat pumps. The small scale coated samples have a zeolite dry mass of 200 mg and layer thicknesses of 200, 300 and 500 μm while the full scale adsorbers have a coated zeolite mass between 1.5 and 2.5 kg and layer thicknesses of 150, 200, 300, 400 and 500 μm. In the investigated adsorption heat pump module, up to 52.7 and 57.3\% of the equilibrium differential water loading measured with the small scale coated substrates have been obtained after an adsorption-evaporation times of 300 and 600 s, respectively.}, language = {en} } @article{GamischHuberGadereretal., author = {Gamisch, Bernd and Huber, Lea and Gaderer, Matthias and Dawoud, Belal}, title = {On the Kinetic Mechanisms of the Reduction and Oxidation Reactions of Iron Oxide/Iron Pellets for a Hydrogen Storage Process}, series = {Energies}, volume = {15}, journal = {Energies}, number = {21}, publisher = {MDPI}, doi = {10.3390/en15218322}, abstract = {This work aims at investigating the kinetic mechanisms of the reduction/oxidation (redox) reactions of iron oxide/iron pellets under different operating conditions. The reaction principle is the basis of a thermochemical hydrogen storage system. To simulate the charging phase, a single pellet consisting of iron oxide (90\% Fe2O3, 10\% stabilising cement) is reduced with different hydrogen (H2) concentrations at temperatures between 600 and 800 °C. The discharge phase is initiated by the oxidation of the previously reduced pellet by water vapour (H2O) at different concentrations in the same temperature range. In both reactions, nitrogen (N2) is used as a carrier gas. The redox reactions have been experimentally measured in a thermogravimetric analyser (TGA) at a flow rate of 250 mL/min. An extensive literature review has been conducted on the existing reactions' kinetic mechanisms along with their applicability to describe the obtained results. It turned out that the measured kinetic results can be excellently described with the so-called shrinking core model. Using the geometrical contracting sphere reaction mechanism model, the concentration- and temperature-dependent reduction and oxidation rates can be reproduced with a maximum deviation of less than 5\%. In contrast to the reduction process, the temperature has a smaller effect on the oxidation reaction kinetics, which is attributed to 71\% less activation energy (Ea,Re=56.9 kJ/mol versus Ea,Ox=16.0 kJ/mol). The concentration of the reacting gas showed, however, an opposite trend: namely, to have an almost twofold impact on the oxidation reaction rate constant compared to the reduction rate constant.}, language = {en} } @article{GamischEttengruberGadereretal., author = {Gamisch, Bernd and Ettengruber, Stefan and Gaderer, Matthias and Dawoud, Belal}, title = {Dynamic simulation of isothermal and non-isothermal reduction and oxidation reactions of iron oxide for a hydrogen storage process}, series = {Renewable and Sustainable Energy}, volume = {1}, journal = {Renewable and Sustainable Energy}, number = {1}, publisher = {ELSP, International Open Science Platform}, doi = {10.55092/rse20230004}, abstract = {This work aims first to develop a dynamic lumped model for the isothermal reactions of hydrogen/steam with a single iron oxide/iron pellet inside a tubular reactor and to validate the model results against the experimental reaction kinetic data with the help of our STA device. To describe the temporal change in mass, and consequently, the temporal heat of reaction, the shrinking core model, based on the geometrical contracting sphere, is applied. It turned out that, the simulation model can reproduce the experimental, temporal concentration and temperature-dependent conversion rates with a maximum deviation of 4.6\% during the oxidation reactions and 3.1\% during the reduction reactions. In addition, a measured isothermal storage process comprising one reduction and one oxidation phase with a holding phase in between on a single reacting pellet could be reproduced with a maximum absolute deviation in the conversion rate of 1.5\%. Moreover, a lumped, non-isothermal simulation model for a pelletized tubular redox-reactor including 2kg of iron oxide pellets has been established, in which the heat of reaction, heat transfer to the ambient and heat transfer between the solid and gas phases are considered. The temporal courses of the outlet gas concentration as well as the temperatures of the gas stream and the solid material at a constant input gas flow rate and a constant reacting gas inlet concentration but different input gas temperatures are estimated. Because of the endothermic nature of the reduction reaction, the inlet reacting gas temperature shall be kept high to prevent the severe temperature drop in the solid phase and, consequently, the significant reduction of the reaction rate. Contrary to that, the oxidation process requires lower input gas temperatures to avoid the excessive overheating of the reaction mass and, consequently, the sintering of the reacting pellets. Finally, five of the previous reactors have been connected in series to explore the influence of the changing inlet gas temperatures and concentrations on the dynamic performance of each storage mass.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {On the application of adsorber plate heat exchangers in thermally driven chillers}, series = {Applied Thermal Engineering}, volume = {220}, journal = {Applied Thermal Engineering}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2022.119713}, abstract = {The effect of both heat and mass transfer characteristic lengths (HTCL, MTCL) of two different adsorber plate heat exchangers (APHE), for application in an adsorption chiller, on the adsorption and desorption kinetics is investigated. Three representative test frames (TF1-TF3) are prepared to examine small-scale adsorbent samples of the microporous silica gel (Siogel of Oker-Chemie, Germany) applying the volumetric large-temperature-jump methodology at different operating conditions. Based on the obtained kinetic data, an analytical model has been developed to predict the specific cooling power (SCP) and the coefficient of performance (COP) of a single-bed adsorption chiller comprising the studied APHEs. It turned out that, within the tested range of HTCL and MTCL, it can be concluded that, the adsorption kinetics are mainly influenced by the MTCL, while the desorption kinetics are dominated by the HTCL of the adsorbent domain. Applying Siogel as loose pellets inside a newly introduced APHE results in of 423.3 and 182.7 W⋅kg-1, at the evaporator temperatures of 15 °C and 5 °C, respectively. Herein, the condenser and adsorber-end temperatures amount to 30 °C and the desorption-end temperature to 90 °C. The corresponding s amount to 0.50 and 0.40, respectively, which represent quite promising results for further design optimizations.}, language = {en} } @article{FrazzicaPalombaDawoud, author = {Frazzica, Andrea and Palomba, Valeria and Dawoud, Belal}, title = {Thermodynamic Performance of Adsorption Working Pairs for Low-Temperature Waste Heat Upgrading in Industrial Applications}, series = {Applied Sciences}, volume = {11}, journal = {Applied Sciences}, number = {8}, publisher = {MDPI}, doi = {10.3390/app11083389}, abstract = {The present work aims at the thermodynamic analysis of different working pairs in adsorption heat transformers (AdHT) for low-temperature waste heat upgrade in industrial processes. Two different AdHT configurations have been simulated, namely with and without heat recovery between the adsorbent beds. Ten working pairs, employing different adsorbent materials and four different refrigerants, have been compared at varying working boundary conditions. The effects of heat recovery and the presence of a temperature gradient for heat transfer between sinks/sources and the AdHT components have been analyzed. The achieved results demonstrate the possibility of increasing the overall performance when internal heat recovery is implemented. They also highlight the relevant role played by the existing temperature gradient between heat transfer fluids and components, that strongly affect the real operating cycle of the AdHT and thus its expected performance. Both extremely low, i.e., 40-50 degrees C, and low (i.e., 80 degrees C) waste heat source temperatures were investigated at variable ambient temperatures, evaluating the achievable COP and specific energy. The main results demonstrate that optimal performance can be achieved when 40-50 K of temperature difference between waste heat source and ambient temperature are guaranteed. Furthermore, composite sorbents demonstrated to be the most promising adsorbent materials for this application, given their high sorption capacity compared to pure adsorbents, which is reflected in much higher achievable specific energy.}, language = {en} } @article{MalzSteiningerDawoudetal., author = {Malz, Sebastian and Steininger, Peter and Dawoud, Belal and Krenkel, Walter and Steffens, Oliver}, title = {On the Development of a Building Insulation using Air Layers with Highly Reflective Interfaces}, series = {Energy and Buildings}, journal = {Energy and Buildings}, number = {236, April}, publisher = {Elsevier}, doi = {10.1016/j.enbuild.2021.110779}, abstract = {In this work, a novel building insulation system implying wooden fiberboards and intermediate air layers with highly reflective interfaces for the reflection of longwave IR radiation is introduced. A wall test sample with a double air insulation layer has been built and experimentally investigated in a dedicated setup, which consists of a differential climatic chamber to simulate different indoor and outdoor conditions. The test results have been utilized in validating the developed simulation model. In addition, a thorough numerical parameter study has been conducted, through which the general design rules of the introduced insulation system for realizing the lowest possible effective thermal conductivity have been defined. Furthermore, a multi-air-layer-insulation concept is developed, and the energy saving potential is evaluated. It turned out that, emissivity, object size and air layer thickness are the most dominant design parameters which influence the thermal conductivity of the introduced insulation. A thermal conductivity of 0.033 W/(mK) has been estimated for a multi-air-layer insulation with 7 layers. The obtained results prove the high insulation potential of the introduced building insulation system compared with insulating materials available in the market while outlining their limitations.}, language = {en} } @article{GaertnerRankHeberletal., author = {G{\"a}rtner, Sebastian and Rank, Daniel and Heberl, Michael and Gaderer, Matthias and Dawoud, Belal and Haumer, Anton and Sterner, Michael}, title = {Simulation and Techno-Economic Analysis of a Power-to-Hydrogen Process for Oxyfuel Glass Melting}, series = {Energies}, volume = {14}, journal = {Energies}, number = {24}, publisher = {MDPI}, doi = {10.3390/en14248603}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-22713}, abstract = {As an energy-intensive industry sector, the glass industry is strongly affected by the increasingly stringent climate protection targets. As established combustion-based production systems ensure high process stability and glass quality, an immediate switch to low greenhouse gas emission processes is difficult. To approach these challenges, this work investigates a step-by-step integration of a Power-to-Hydrogen concept into established oxyfuel glass melting processes using a simulation approach. This is complemented by a case study for economic analysis on a selected German glass industry site by simulating the power production of a nearby renewable energy park and subsequent optimization of the power-to-hydrogen plant performance and capacities. The results of this study indicate, that the proposed system can reduce specific carbon dioxide emissions by up to 60\%, while increasing specific energy demand by a maximum of 25\%. Investigations of the impact of altered combustion and furnace properties like adiabatic flame temperature (+25 °C), temperature efficiency (∆ξ = -0.003) and heat capacity flow ratio (∆zHL = -0.009) indicate that pure hydrogen-oxygen combustion has less impact on melting properties than assumed so far. Within the case study, high CO2 abatement costs of 295 €/t CO2-eq. were determined. This is mainly due to the insufficient performance of renewable energy sources. The correlations between process scaling and economic parameters presented in this study show promising potential for further economic optimization of the proposed energy system in the future.}, language = {en} } @article{PalombaNowakDawoudetal., author = {Palomba, Valeria and Nowak, Sebastian and Dawoud, Belal and Frazzica, Andrea}, title = {Dynamic modelling of Adsorption systems: a comprehensive calibrated dataset for heat pump and storage applications}, series = {Journal of energy storage}, volume = {33}, journal = {Journal of energy storage}, publisher = {Elsevier}, doi = {10.1016/j.est.2020.102148}, abstract = {The growing efforts for the development of clean and efficient energy systems require the use of a multi-disciplinary approach and the integration of multiple generation appliances. Among the fields that can be considered enabling technologies, adsorption systems for air conditioning and thermal energy storages, are constantly increasing their maturity. However, for a proper design and integration of such systems, there is the need for a simulation framework that is reliable and computationally convenient. In the present paper, the implementation of a dynamic model for adsorption systems is presented, which includes different components (adsorber, phase changer, sorption materials) and is structured as a library. Modelica language and the commercial software Dymola (R) are used for the analysis. Data for different heat exchangers and working pairs are calibrated using experimental results and the calibrated model is subsequently used for the design of an adsorber based on a plate heat exchanger for thermal energy storage applications. The results proved that the model is fast and can reproduce experimental results with good accuracy, thus being a useful tool for the design and optimization of the different components of sorption systems.}, language = {en} } @article{SovacoolCabezaPiselloetal., author = {Sovacool, Benjamin K. and Cabeza, Luisa F. and Pisello, Anna Laura and Colladon, Andrea Fronzetti and Larijani, Hatef Madani and Dawoud, Belal and Martiskainen, Mari}, title = {Decarbonizing household heating: Reviewing demographics, geography and low-carbon practices and preferences in five European countries}, series = {Renewable \& Sustainable Energy Reviews}, journal = {Renewable \& Sustainable Energy Reviews}, number = {139}, publisher = {Elsevier}, doi = {10.1016/j.rser.2020.110703}, pages = {1 -- 28}, abstract = {What commonalities are there in sustainable or unsustainable heating practices in five high-income, high-emitting western European countries? What preferences do a nationally representative sample of the public in these countries hold towards low-carbon options? It is imperative that climate policy researchers and practitioners grapple with the difficulty of decarbonizing heat, which remains the largest single end-use service worldwide and which accounts about half of total final energy consumption. Based on a comparative assessment of five representative national surveys in Germany (N = 2009), Italy (N = 2039), Spain (N = 2038), Sweden (N = 2023), and the United Kingdom (N = 2000), this study explores the demographics and geography of household heat decarbonisation in Europe. By analyzing our country level data as well as our combined sample of 10,109 respondents, it investigates how people conceive of the purposes of low-carbon heat, their preferences for particular forms of heat supply, and their (at times odd) practices of heat consumption and temperature settings. Grounded in its original data, the study organizes its findings inductively across the five themes of literacy (heating knowledge, awareness and control), sustainability (heating practices, dynamics and conflicts), temperature (heating satisfaction and preferences), desirability of change (low-carbon heating priorities, business models and trust), and culture (country and national variation). The study also explores intersections between these dimensions, using multivariate analysis, as well as how preferences differ according to varying types of actors as well as geography and space.}, language = {en} } @article{MikhaeilNowakPalombaetal., author = {Mikhaeil, Makram and Nowak, Sebastian and Palomba, Valeria and Frazzica, Andrea and Gaderer, Matthias and Dawoud, Belal}, title = {Experimental and analytical investigation of applying an asymmetric plate heat exchanger as an evaporator in a thermally driven adsorption appliance}, series = {Applied Thermal Engineering}, journal = {Applied Thermal Engineering}, number = {228}, publisher = {Elsevier}, doi = {10.1016/j.applthermaleng.2023.120525}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-61115}, abstract = {This communication presents an experimental and analytical study on the evaporation mechanism in a closed-structured asymmetric plate heat exchanger (PHE) employed as a stagnant water evaporator for the application in an adsorption heat transformation appliance. To this aim, an experimental unit is constructed, which comprises two identical PHEs, one acting as an vaporator/condenser and the second, as an adsorber/desorber. Two endoscopes are mounted inside the investigated evaporator to visualize the evaporation mechanism when performing adsorption-evaporation processes under different boundary conditions. It turned out that the evaporation mechanism is a partially covered, thin film evaporation. A heat transfer analysis is performed to evaluate the heat transfer coefficient of the thin film evaporation () inside the investigated evaporator, resulting in -values between 1330 and 160 [W∙m-2∙K-1] over the investigated adsorption-evaporation time. Correlating the obtained () to the film thickness and the wetted area results in -values between 0.34 and 0.78 [mm] and wetted to total area ratios of 0.78 to 0.16. Besides, an analytical model has been developed and introduced to correlate the overall evaporator heat transfer coefficient with the adsorption potential and the time rate of change of the water uptake.}, language = {en} } @article{MikhaeilGadererDawoud, author = {Mikhaeil, Makram and Gaderer, Matthias and Dawoud, Belal}, title = {On the development of an innovative adsorber plate heat exchanger for adsorption heat transformation processes; an experimental and numerical study}, series = {Energy}, volume = {207}, journal = {Energy}, number = {September}, publisher = {Elsevier}, doi = {10.1016/j.energy.2020.118272}, pages = {1 -- 13}, abstract = {An innovative adsorber plate heat exchanger (APHE), which is developed for application in adsorption heat pumps, chillers and thermal energy storage systems, is introduced. A test frame has been constructed as a representative segment of the introduced APHE for applying loose grains of AQSOA-Z02. Adsorption kinetic measurements have been carried out in a volumetric large-temperature-jump setup under typical operating conditions of adsorption processes. A transient 2-D model is developed for the tested sample inside the setup. The measured temporal uptake variations with time have been fed to the model, through which a micro-pore diffusion coefficient at infinite temperature of 2 E-4 [m2s-1] and an activation energy of 42.1 [kJ mol-1] have been estimated. A 3-D model is developed to simulate the combined heat and mass transfer inside the APHE and implemented in a commercial software. Comparing the obtained results with the literature values for an extruded aluminium adsorber heat exchanger coated with a 500 μm layer of the same adsorbent, the differential water uptake obtained after 300 s of adsorption (8.2 g/100 g) implies a sound enhancement of 310\%. This result proves the great potential of the introduced APHE to remarkably enhance the performance of adsorption heat transformation appliances.}, language = {en} } @article{HuberHeindlSchlosseretal., author = {Huber, Lea and Heindl, Melanie and Schlosser, Marc and Pfitzner, Arno and Dawoud, Belal}, title = {On the Cycle Stability and Macroscopic Structure of Iron Oxide Pellets for Thermochemical Hydrogen Storage: Influence of Water Content during the Pelletizing Process}, series = {Applied Sciences}, volume = {13}, journal = {Applied Sciences}, number = {11}, publisher = {MDPI}, address = {16}, doi = {10.3390/app13116408}, abstract = {Hydrogen storage based on the repeated reduction and oxidation (redox) reactions of iron oxide/iron composites represents a promising technology. This work is dedicated to studying the influence of the amount of water added during the pelletizing process on the cycle stability and structure of iron oxide pellets. The storage composites were prepared from iron oxide (Fe2O3) and 10 wt.-\% support material (cement) with different amounts of water (18 and 33 wt.-\%) in a laboratory-scale pelletizing disk. To evaluate the cycle stability of the composites, the kinetics of the redox reactions were experimentally measured at 800 ∘ C in an atmosphere of 50\% N2 and 50\% H2 (reduction) or 50\% steam (oxidation), respectively. Moreover, the structure of the pellets was analyzed by micro-computed tomography scans. It turned out that pellets with higher water contents attained faster kinetics and a higher cycle stability. The sample with the least water content (18 wt.-\%) needed about 26 min and 19 min to reach a conversion rate of 80\% during the reduction and oxidation reactions of the sixth redox cycle, respectively. In contrast, the sample with the highest water content (33 wt.-\%) could achieve the same conversion rate after 18 min (reduction) and 13 min (oxidation) during the ninth redox cycle.}, language = {en} } @techreport{AndratschkeCeulloDawoudetal., author = {Andratschke, Christin and Ceullo, Laura and Dawoud, Belal and Draeger, Susan and Gerdes, Thorsten and Giebisch, Matthias and Grießhammer, Peter and Haas, Katharina and Haug, Sonja and Helling, Dominik and Kominis, Lena and Lang, Christian and Malz, Sebastian and Melzl, Johannes and Michlbauer, David and M{\"u}hlberger, Thomas and Nagl, Klaus and Preis, Michael and Rechenauer, Christian and Riederer, Michael and R{\"u}ckerl, Alexander and Saller, Tobias and Schnabl, Andreas and Stadler, Michael and Steffens, Oliver and Steininger, Peter and Stelzl, Andr{\´e} and Toutouly, Lovis and Trauner, Matthias and Vetter, Miriam and Walbrunn, Johannes and Weber, Karsten and Zielbauer, Lukas}, title = {MAGGIE: Energetische Modernisierung des genossenschaftlichen Wohnquartiers Margaretenau in Regensburg}, editor = {Steffens, Oliver}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-96256-100-0}, doi = {10.35096/othr/pub-5901}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-59011}, pages = {XVIII, 462 S.}, abstract = {Im Projekt MAGGIE wurden f{\"u}r das genossenschaftliche historische Stadtquartier „Margaretenau" in Regensburg Musterl{\"o}sungen f{\"u}r energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht. Dazu wurde ein bestehendes Wohngeb{\"a}ude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus W{\"a}rmepumpentechnologie und Kraft- W{\"a}rme-Kopplung ausgestattet und untersucht, erg{\"a}nzt durch eine dynamische W{\"a}rmelogistik zur Verringerung von Verteilungsverlusten. Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems w{\"a}hrend des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Stromb{\"o}rse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltw{\"a}rme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Geb{\"a}udebetrieb. F{\"u}r die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realit{\"a}t getestet. Am Bestandsgeb{\"a}ude kam anstelle eines W{\"a}rmed{\"a}mmverbundsystems ein innovativer D{\"a}mmputz mit Mikrohohlglaskugeln zum Einsatz. Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles {\"u}ber mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete f{\"u}r die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erh{\"o}ht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.}, subject = {Altbaumodernisierung}, language = {de} } @article{SalamaKouDawoudetal., author = {Salama, Amgad and Kou, Jisheng and Dawoud, Belal and Simonson, Carey}, title = {A modeling approach for capillary-driven flow of a wetting fluid in a rectangular open microchannel of arbitrary axisymmetric width profile}, series = {International Journal of Thermal Sciences}, volume = {195}, journal = {International Journal of Thermal Sciences}, publisher = {Elsevier}, issn = {1290-0729}, doi = {10.1016/j.ijthermalsci.2023.108622}, pages = {17}, abstract = {Microchips are intensively used in almost all nowadays electronic devices. With the continuous advancement of our technologies, they get smaller in size than ever before. They generate high-intensity heat loads that need to be transported effectively such that they may function properly. Heat pipes have proven to be very effective in transporting relatively large heat loads from miniature components. They are of seamless structure that involves a working fluid capable of evaporation and condensation at the working temperature of the electronic chips. The working fluid is derived to move from the condenser to the evaporator via multiple microgrooves using capillary forces. It is important that the condensate reaches the evaporator at a proper rate such that no dry-out or flooding occur. In this work, we are particularly interested in the case of capillary-driven flows in rectangular microchannels. A generalized model is developed that works for axe-symmetric rectangular channels of arbitrary, moderately varying width profiles. It also accounts for any contrast of viscosity between the liquid and the vapor under isothermal conditions. The model shows to reduce to the special case of imbibition in straight and uniform microchannels, for which comparisons with experimental and modeling works show an excellent match. Cases representing linearly and quadratically varying converging/diverging width profiles have been explored. It is found that the viscosity ratio has a significant influence on the rate at which the meniscus advances. The model also negates the common practice found in the literature of using the formula developed for imbibition rates in capillary tubes for rectangular microchannels by replacing the diameter of the tube with the hydraulic diameter. It is also found that the channel profile has an influential effect on the imbibition rates. For tapered microchannels, the capillary force increases along the channel length while it decreases for diverging ones. It is interestingly demonstrated that, for quadratically tapered microchannel, the speed of the meniscus increases towards the end of the microchannel compared with linearly varying microchannels. On the other hand, for diverging microchannels, the speed of the meniscus decreases due to the increase in the cross-sectional area. Computational fluid dynamics (CFD) analysis has been conducted to provide a framework for confirmation and verification for which very good match has been established, which builds confidence in the modeling approach.}, language = {en} } @misc{AppelhansKampmannMottoketal., author = {Appelhans, Marie-Luise and Kampmann, Matthias and Mottok, J{\"u}rgen and Riederer, Michael and Nagl, Klaus and Steffens, Oliver and D{\"u}nnweber, Jan and Wildgruber, Markus and Roth, Julius and Stadler, Timo and Palm, Christoph and Weiß, Martin Georg and Rochholz, Sandra and Bierl, Rudolf and Gschossmann, Andreas and Haug, Sonja and Schmidbauer, Simon and Koch, Anna and Westner, Markus and Bary, Benedikt von and Ellermeier, Andreas and V{\"o}gele, Daniel and Maiwald, Frederik and Hierl, Stefan and Schlamp, Matthias and Ehrlich, Ingo and Siegl, Marco and H{\"u}ntelmann, Sven and Wildfeuer, Matthias and Br{\"u}ckl, Oliver and Sterner, Michael and Hofrichter, Andreas and Eckert, Fabian and Bauer, Franz and Dawoud, Belal and Rabl, Hans-Peter and Gamisch, Bernd and Schmidt, Ottfried and Heberl, Michael and Thema, Martin and Mayer, Ulrike and Eller, Johannes and Sippenauer, Thomas and Adelt, Christian and Haslbeck, Matthias and Vogl, Bettina and Mauerer, Wolfgang and Ramsauer, Ralf and Lohmann, Daniel and Sax, Irmengard and Gabor, Thomas and Feld, Sebastian and Linnhoff-Popien, Claudia and Ławrowski, Robert Damian and Langer, Christoph and Schreiner, Rupert and Sellmair, Josef}, title = {Forschung 2019}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-7-3}, doi = {10.35096/othr/pub-789}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-7890}, pages = {72}, abstract = {Bericht mit Forschungsprojekten aus verschiedenen Bereichen der OTH Regensburg mit dem Schwerpunktthema "K{\"u}nstliche Intelligenz" und einem Gespr{\"a}ch zur "Medizin der Zukunft"}, subject = {Forschung}, language = {de} } @techreport{AndratschkeCeulloDawoudetal., author = {Andratschke, Christin and Ceullo, Laura and Dawoud, Belal and Draeger, Susan and Gerdes, Thorsten and Giebisch, Matthias and Grießhammer, Peter and Haas, Katharina and Haug, Sonja and Helling, Dominik and Kominis, Lena and Lang, Christian and Malz, Sebastian and Melzl, Johannes and Michlbauer, David and M{\"u}hlberger, Thomas and Nagl, Klaus and Preis, Michael and Rechenauer, Christian and Riederer, Michael and R{\"u}ckerl, Alexander and Saller, Tobias and Schnabl, Andreas and Stadler, Michael and Steffens, Oliver and Steininger, Peter and Stelzl, Andr{\´e} and Toutouly, Lovis and Trauner, Matthias and Vetter, Miriam and Walbrunn, Johannes and Weber, Karsten and Zielbauer, Lukas}, title = {MAGGIE: Energetische Modernisierung des genossenschaftlichen Wohnquartiers Margaretenau in Regensburg}, editor = {Steffens, Oliver}, address = {Regensburg}, isbn = {978-3-96256-100-0}, doi = {10.35096/othr/pub-5335}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-53354}, pages = {XVIII, 462 S.}, abstract = {Im Projekt MAGGIE wurden f{\"u}r das genossenschaftliche historische Stadtquartier „Margaretenau" in Regensburg Musterl{\"o}sungen f{\"u}r energieoptimiertes Wohnen mit innovativen Wandaufbauten aus solaraktiven Baukonstruktionen und einer vorhersagebasierten Versorgungstechnologie erforscht. Dazu wurde ein bestehendes Wohngeb{\"a}ude als Demonstrations- und Versuchsobjekt mit einem neuartigen, besonders effizienten Hybridsystem aus W{\"a}rmepumpentechnologie und Kraft- W{\"a}rme-Kopplung ausgestattet und untersucht, erg{\"a}nzt durch eine dynamische W{\"a}rmelogistik zur Verringerung von Verteilungsverlusten. Das System wurde durch ein neu entwickeltes, allgemein einsetzbares Planungs-, Optimierungs- und Steuerungstool ausgelegt und im Betrieb geregelt. Die in Echtzeit laufende Nachoptimierung des Systems w{\"a}hrend des Betriebs greift dabei auf reale Monitoringdaten zu. Die Einbindung von Nutzerbedarfsprofilen, Stromb{\"o}rse und Wetterdaten in die Steuerung gestattet einen dynamischen und perspektivischen Anlagenbetrieb zur Maximierung der Solar- und Umweltw{\"a}rme-Anteile der Energieversorgung und leistet damit einen wirksamen Beitrag zu einem emissionsarmen, klimafreundlichen Geb{\"a}udebetrieb. F{\"u}r die denkmalgerechte Modernisierung der historischen Fassaden wurde ein solaraktives und solaradaptives Außenputzsystem entwickelt und in der Realit{\"a}t getestet. Am Bestandsgeb{\"a}ude kam anstelle eines W{\"a}rmed{\"a}mmverbundsystems ein innovativer D{\"a}mmputz mit Mikrohohlglaskugeln zum Einsatz. Die Skalierbarkeit erlaubt eine abschnittsweise Modernisierung des gesamten Ensembles {\"u}ber mehrere Jahre. Durch die hohe Energieeffizienz wird die Warmmiete f{\"u}r die Bewohner der genossenschaftlichen Siedlung durch die Modernisierungsmaßnahmen nicht erh{\"o}ht, so dass auch nach der Modernisierung ein bezahlbares Wohnen sichergestellt wird.}, subject = {Altbaumodernisierung}, language = {de} } @misc{BroserFalterŁawrowskietal., author = {Broser, Christian and Falter, Thomas and Ławrowski, Robert Damian and Altenbuchner, Amelie and V{\"o}gele, Daniel and Koss, Claus and Schlampp, Matthias and Dunnweber, Jan and Steffens, Oliver and Heckner, Markus and Jaritz, Sabine and Schiegl, Thomas and Corsten, Sabine and Lauer, Norina and Guertler, Katherine and Koenig, Eric and Haug, Sonja and Huber, Dominik and Birkenmaier, Clemens and Krenkel, Lars and Wagner, Thomas and Justus, Xenia and Saßmannshausen, Sean Patrick and Kleine, Nadine and Weber, Karsten and Braun, Carina N. and Giacoppo, Giuliano and Heinrich, Michael and Just, Tobias and Schreck, Thomas and Schnabl, Andreas and Gilmore, Amador T{\´e}ran and Roeslin, Samuel and Schmid, Sandra and Wellnitz, Felix and Malz, Sebastian and Maurial, Andreas and Hauser, Florian and Mottok, J{\"u}rgen and Klettke, Meike and Scherzinger, Stefanie and St{\"o}rl, Uta and Heckner, Markus and Bazo, Alexander and Wolff, Christian and Kopper, Andreas and Westner, Markus and Pongratz, Christian and Ehrlich, Ingo and Briem, Ulrich and Hederer, Sebastian and Wagner, Marcus and Schillinger, Moritz and G{\"o}rlach, Julien and Hierl, Stefan and Siegl, Marco and Langer, Christoph and Hausladen, Matthias and Schreiner, Rupert and Haslbeck, Matthias and Kreuzer, Reinhard and Br{\"u}ckl, Oliver and Dawoud, Belal and Rabl, Hans-Peter and Gamisch, Bernd and Schmidt, Ottfried and Heberl, Michael and G{\"a}nsbauer, Bianca and Bick, Werner and Ellermeier, Andreas and Monkman, Gareth J. and Prem, Nina and Sindersberger, Dirk and Tschurtschenthaler, Karl and Aurbach, Maximilian and Dendorfer, Sebastian and Betz, Michael A. and Szecsey, Tamara and Mauerer, Wolfgang and Murr, Florian}, title = {Forschung 2018}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-5-9}, doi = {10.35096/othr/pub-1382}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-13826}, pages = {98}, subject = {Forschung}, language = {de} }