@article{LangerBerndtSchreiner, author = {Langer, Christoph and Berndt, Dominik and Schreiner, Rupert}, title = {Sensitivity of thermal conductivity vacuum gauges for constant current and constant temperature operation}, series = {Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics}, volume = {40}, journal = {Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics}, number = {5}, publisher = {AIP Publishing}, doi = {10.1116/6.0001964}, abstract = {To optimize the measurement range of thermal conductivity vacuum gauges, an expression for the sensitivity is required that takes into account all geometrical, material-specific, and operating parameters. Therefore, equations of the sensor output signal as a function of the pressure for the constant current and the constant temperature mode have been developed analytically. Based on these equations, the sensitivity of the vacuum gauge and its influencing parameters was investigated and discussed. For comparable conditions, the constant temperature operation shows a significantly higher sensitivity for high pressures, while the constant current operation shows higher sensitivity at low pressures. The sensitivity in both the constant current and the constant temperature mode depends on the ratio of the filament surface area and the parasitic thermal conductance. In addition, for the constant current operation, the sensitivity also depends on the current value and the temperature coefficient of the filament resistor. For the constant temperature operation, the sensitivity additionally depends on the distance of the filament and the reference plane. However, to extend the measurement range of a thermal conductivity vacuum gauge toward low pressures, a reduction of the parasitic thermal conductance is mandatory for both the constant current and the constant temperature mode.}, language = {en} } @article{BachmannDuesbergLangeretal., author = {Bachmann, Michael and D{\"u}sberg, Felix and Langer, Christoph and Herdl, Florian and Bergbreiter, Lukas and Dams, Florian and Miyakawa, Natuski and Eggert, Tobias and Pahlke, Andreas and Edler, Simon and Prommesberger, Christian and Ławrowski, Robert Damian and Hausladen, Matthias and Schreiner, Rupert}, title = {Vacuum-sealed field emission electron gun}, series = {Journal of Vacuum Science \& Technology B}, volume = {38}, journal = {Journal of Vacuum Science \& Technology B}, number = {2}, publisher = {AIP Publishing}, doi = {10.1116/1.5139316}, abstract = {A compact vacuum-sealed field emission electron gun with an operation voltage below 5 kV is presented. With a 150 nm thick pyrolytic carbon membrane, a transmission of 40\% at 5 kV is obtained. For more than 2500 h of continuous operation at an emission current of 100 nA, no significant increase (<50V ) and almost no degradation were found. From this measurement, a lifetime of more than 10 000 h at continuous operation with approximately a linear increase of the extraction voltage from about 545 V to about 730 V is predicted. This electron source enables application of field emitter arrays in poor vacuum or even ambient pressure. ACKNOWLEDGMENT This work was supported by the German Federal Ministry for Economic Affairs and Energy under Project No. ZF4081502GM8. C.P., R.L., M.H., and R.S. were supported by Grant No. ZF4562901GM8.}, language = {en} } @article{LangerBomkeHausladenetal., author = {Langer, Christoph and Bomke, Vitali and Hausladen, Matthias and Ławrowski, Robert Damian and Prommesberger, Christian and Bachmann, Michael and Schreiner, Rupert}, title = {Silicon Chip Field Emission Electron Source Fabricated by Laser Micromachining}, series = {Journal of Vacuum Science \& Technology B}, volume = {38}, journal = {Journal of Vacuum Science \& Technology B}, number = {1}, publisher = {AIP Publishing}, doi = {10.1116/1.5134872}, abstract = {The components for a silicon chip electron source were fabricated by laser micromachining using pulsed laser ablation and wet chemical cleaning and etching dips. The field emission electron source consists of a silicon field emission cathode with 4 × 4 conical shaped emitters with a height of 250 μm and a tip radius of about 50 nm, a 50 μm thick laser-structured mica spacer, and a silicon grid electrode with a grid periodicity of 200 μm and a bar width of 50 μm. These three components are combined to a single chip with the size of 14 × 10 mm2 and the thickness of 1 mm to form the electron source. Several of these devices were characterized in ultrahigh vacuum. Onset voltages of about 165 V and cathode currents of about 15 μA for voltages lower than 350 V were observed. Operating the electron source with an anode voltage of 500 V and an extraction grid voltage of 300 V yielded a cathode current of 4.5 μA ± 8.9\%, an anode current of 4.0 μA ± 9.6\%, and a corresponding grid transmittance of 89\%. Regulating the anode current by the extraction grid voltage, an extremely stable anode current of 5.0 μA ± 0.017\% was observed. A long-term measurement over 120 h was performed, and no significant degradation or failure was observed.}, language = {en} } @article{BerndtMuggliWittweretal., author = {Berndt, Dominik and Muggli, Josef and Wittwer, Franz and Langer, Christoph and Heinrich, Stephan and Knittel, Thorsten and Schreiner, Rupert}, title = {MEMS-based thermal conductivity sensor for hydrogen gas detection in automotive applications}, series = {Sensors and Actuators A: Physical}, volume = {305}, journal = {Sensors and Actuators A: Physical}, number = {April}, publisher = {Elsevier}, doi = {10.1016/j.sna.2019.111670}, abstract = {Accurate detection of hydrogen gas in vehicle interiors is very important for the future of a fuel cell car. Since this type of gas is highly volatile and flammable, the measurement methods have to be very reliable and precise due to safety reasons. In this paper a thermal conductivity sensor for hydrogen gas detection is presented, exhibiting a lower detection limit of 2000 ppm hydrogen in laboratory air. The sensor element is realized by micro-fabrication techniques on silicon wafers. The heated filament is exposed by a selective wet etching process creating a micro-hotplate on a thin membrane. In order to minimize power consumption, the sensor is operated in pulsed mode. Hydrogen gas detection was carried out using a synthetic gas testbench. Measurements of hydrogen contents ranging from 0\% to 4\% with an increment of 0.5\% were successfully performed for ambient gas temperatures between -15°C and 84°C. Including humidity, high moisture contents have the greatest influence on thermal conductivity. This was predicted in theoretical investigations and confirmed in experiments. For evaluation, both the change in resistance ΔR as well as the time constant τ were taken as sensor output. For both quantities, the previously established theoretical relationship with thermal conductivity could be confirmed.}, language = {en} } @article{KleshchSerbunLuetzenkirchenHechtetal., author = {Kleshch, Victor I. and Serbun, Pavel and L{\"u}tzenkirchen-Hecht, Dirk and Orekhov, Anton S. and Ivanov, Victor E. and Prommesberger, Christian and Langer, Christoph and Schreiner, Rupert and Obraztsov, Alexander N.}, title = {A Comparative Study of Field Emission from Pristine, Ion-treated and Tungsten Nanoparticle-decorated p-type Silicon Tips}, series = {Physica Status Solidi B}, volume = {256}, journal = {Physica Status Solidi B}, number = {9}, publisher = {Wiley}, doi = {10.1002/pssb.201800646}, abstract = {The field electron emission characteristics of individual tips of a silicon field emitter array are analyzed. The array of conical-shaped tips is fabricated on a p-type silicon wafer by using reactive ion etching and sharpening oxidation. The tips are decorated with single tungsten nanoparticles at their apexes. Furthermore, the focused ion beam is also used to increase surface conductivity of some of the tips. Comparative measurements of field emission are performed by using the scanning anode probe field emission microscopy technique. All types of tips demonstrated emission activation consisting of a sudden current increase at a certain value of the applied voltage. Compared to the pristine tips, a noticeable reduction of the saturation effect in the current-voltage characteristics and a smaller light sensitivity for the decorated tips is found. For ion-treated tips, saturation effects and light sensitivity are completely suppressed. Scanning electron microscopy observations reveal the formation of single nanoscale protrusions extending from the metal particles and from the apexes of bare ion-treated tips after exposure under strong electric fields during the field emission measurements. The influence of protrusions growth on characteristics of silicon field emitter arrays is discussed.}, language = {en} } @misc{DuesbergBachmannEdleretal., author = {D{\"u}sberg, Felix and Bachmann, Michael and Edler, Simon and Pahlke, Andreas and Langer, Christoph and Prommesberger, Christian and Schreiner, Rupert and Bunert, Erik and Wendt, Cornelius and Zimmermann, Stefan}, title = {Novel Non-Radiative Electron Source}, series = {43rd International Symposium of Capillary Chromatography \& 16h GC x GC Symposium 2019}, journal = {43rd International Symposium of Capillary Chromatography \& 16h GC x GC Symposium 2019}, abstract = {Recently a non-radioactive electron capture detector based on a thermionic electron emitter has been demonstrated [1]. Using field emitter arrays (FEAs) would yield non-radioactive portable low power devices with fast switching capability. By combining FEAs with a vacuum-sealed housing and an electron transparent membrane window, such electron sources can be operated in an ambient pressure environment.}, language = {en} } @misc{AppelhansKampmannMottoketal., author = {Appelhans, Marie-Luise and Kampmann, Matthias and Mottok, J{\"u}rgen and Riederer, Michael and Nagl, Klaus and Steffens, Oliver and D{\"u}nnweber, Jan and Wildgruber, Markus and Roth, Julius and Stadler, Timo and Palm, Christoph and Weiß, Martin Georg and Rochholz, Sandra and Bierl, Rudolf and Gschossmann, Andreas and Haug, Sonja and Schmidbauer, Simon and Koch, Anna and Westner, Markus and Bary, Benedikt von and Ellermeier, Andreas and V{\"o}gele, Daniel and Maiwald, Frederik and Hierl, Stefan and Schlamp, Matthias and Ehrlich, Ingo and Siegl, Marco and H{\"u}ntelmann, Sven and Wildfeuer, Matthias and Br{\"u}ckl, Oliver and Sterner, Michael and Hofrichter, Andreas and Eckert, Fabian and Bauer, Franz and Dawoud, Belal and Rabl, Hans-Peter and Gamisch, Bernd and Schmidt, Ottfried and Heberl, Michael and Thema, Martin and Mayer, Ulrike and Eller, Johannes and Sippenauer, Thomas and Adelt, Christian and Haslbeck, Matthias and Vogl, Bettina and Mauerer, Wolfgang and Ramsauer, Ralf and Lohmann, Daniel and Sax, Irmengard and Gabor, Thomas and Feld, Sebastian and Linnhoff-Popien, Claudia and Ławrowski, Robert Damian and Langer, Christoph and Schreiner, Rupert and Sellmair, Josef}, title = {Forschung 2019}, editor = {Baier, Wolfgang}, address = {Regensburg}, organization = {Ostbayerische Technische Hochschule Regensburg}, isbn = {978-3-9818209-7-3}, doi = {10.35096/othr/pub-789}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-7890}, pages = {72}, abstract = {Bericht mit Forschungsprojekten aus verschiedenen Bereichen der OTH Regensburg mit dem Schwerpunktthema "K{\"u}nstliche Intelligenz" und einem Gespr{\"a}ch zur "Medizin der Zukunft"}, subject = {Forschung}, language = {de} } @article{BreuerBachmannDuesbergetal., author = {Breuer, Janis and Bachmann, Michael and D{\"u}sberg, Felix and Pahlke, Andreas and Edler, Simon and Langer, Christoph and Prommesberger, Christian and Ławrowski, Robert Damian and Schreiner, Rupert and Serbun, Pavel and L{\"u}tzenkirchen-Hecht, Dirk}, title = {Extraction of the current distribution out of saturated integral measurement data of p-type silicon field emitter arrays}, series = {Journal of Vacuum Science and Technology B}, volume = {36}, journal = {Journal of Vacuum Science and Technology B}, number = {5}, publisher = {AIP Publishing}, doi = {10.1116/1.5035189}, abstract = {At the moment, only complicated techniques are known for the determination of array properties of field emitter arrays such as the number of active tips, the current distribution, or the individual tip radii. In this work, a method for extracting these parameters from integral measurement data is presented. A model describing the characteristics of a single emitter, including the saturation as a function of the applied voltage and the emitter radius, is developed. It is shown that experimental data of field emitter arrays can be represented as the sum of these functions and the characteristic parameters can be fitted to field emission data of an array. Using this method, the values of the radii as well as the parameters of distribution models can be determined directly. Analysis of experimental data from p-type Si emitter arrays shows that only 1-2\% of the tips contribute significantly.}, language = {en} } @inproceedings{SerbunPorshynMuelleretal., author = {Serbun, Pavel and Porshyn, V. and M{\"u}ller, G{\"u}nter and L{\"u}tzenkirchen-Hecht, Dirk and Prommesberger, Christian and Langer, Christoph and Ławrowski, Robert Damian and Schreiner, Rupert}, title = {Field emission behavior of single n- and p-type black Si pillar structures}, series = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, booktitle = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, publisher = {IEEE}, doi = {10.1109/IVNC.2018.8520292}, pages = {1-2}, abstract = {We have investigated the properties of single n- and p-type black silicon (b-Si) pillars with a height of 20 μ m under strong electric field and halogen lamp or laser illumination. For both type of b-Si pillar structures, I-V measurements revealed strong activation effects, which consisted in sudden current increases during the first up/down voltage sweeps. The maximum reproducible emission current from a single n-type b-Si pillar structure was about 15 μ A. A pronounced saturation region at 240 nA was observed for a single p-type b-Si pillar. The current fluctuation over time showed a standard deviation of 28\% and 2.5\% for n- and p-type single b-Si pillar structures, respectively. Optical switching under halogen lamp illumination resulted in at least 3 times higher saturation currents and showed a linear dependence of the FE current on the laser power.}, language = {en} } @inproceedings{SerbunPorshynLuetzenkirchenHechtetal., author = {Serbun, Pavel and Porshyn, V. and L{\"u}tzenkirchen-Hecht, Dirk and Prommesberger, Christian and Langer, Christoph and Ławrowski, Robert Damian and Schreiner, Rupert}, title = {Photosensitivity of single silicon high-aspect-ratio tips with different doping levels}, series = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, booktitle = {International Vacuum Nanoelectronics Conference (IVNC), 31st, 2018, Kyoto, Japan}, publisher = {IEEE}, doi = {10.1109/IVNC.2018.8520288}, pages = {1-2}, abstract = {Photosensitivity of single lightly p-doped, highly p-doped, with an integrated p/n junction and intrinsic high-aspect-ratio (HAR) silicon tips was investigated in an ultra-high vacuum environment. The current-voltage characteristics (I-V) of the lightly doped p-type HAR tips showed a characteristic current saturation at around 10-12 nA, whereas the HAR Si tips with p/n junction showed similar saturation phenomena, however, at much smaller current values starting at ~20-30 pA. Optical switching under a halogen lamp illumination resulted in at least 2-4 times higher saturation currents and showed a linear dependence between the illumination power and the FE current, for both types of structures. In case of the highly p-doped HAR tips optical current switching effects, i. e. current saturation, were observed at rather low current levels 1-2 pA. Intrinsic HAR Si-tips showed relative unstable field emission behavior without a clear evidence of the photosensitivity.}, language = {en} }