@article{MartererRadouchovaSoukupetal., author = {Marterer, Verena and Radouchov{\´a}, Michaela and Soukup, Radek and Hipp, Susanne and Blecha, Tom{\´a}š}, title = {Wearable textile antennas: investigation on material variants, fabrication methods, design and application}, series = {Fashion and Textiles}, volume = {11}, journal = {Fashion and Textiles}, publisher = {Springer Open}, doi = {10.1186/s40691-023-00369-1}, abstract = {With the ongoing miniaturization of wireless devices, the importance of wearable textiles in the antenna segment has increased significantly in recent years. Due to the widespread utilization of wireless body sensor networks for healthcare and ubiquitous applications, the design of wearable antennas offers the possibility of comprehensive monitoring, communication, and energy harvesting and storage. This article reviews a number of properties and benefits to realize comprehensive background information and application ideas for the development of lightweight, compact and low-cost wearable patch antennas. Furthermore, problems and challenges that arise are addressed. Since both electromagnetic and mechanical specifications must be fulfilled, textile and flexible antennas require an appropriate trade-off between materials, antenna topologies, and fabrication methods—depending on the intended application and environmental factors. This overview covers each of the above issues, highlighting research to date while correlating antenna topology, feeding techniques, textile materials, and contacting options for the defined application of wearable planar patch antennas.}, language = {en} } @article{ZhaoGaschler, author = {Zhao, Fang and Gaschler, Robert}, title = {Sending motivational emails in text-picture personalised form can be feasible in e-learning: An asynchronous course case}, series = {Open Learning: The Journal of Open, Distance and e-Learning}, journal = {Open Learning: The Journal of Open, Distance and e-Learning}, publisher = {Taylor \& Francis}, doi = {10.1080/02680513.2024.2326002}, pages = {1 -- 15}, abstract = {ntervention with motivational emails can have a positive effect on course retention in e-learning. It is, however, not yet clear whether different forms of emails affect course retention and how students make progress during the sending of emails. We therefore used a voluntary asynchronous online course with 206 students. Students were randomly divided into four groups: text-picture personalised email vs. text personalised email vs. generalised email vs. no email. Emails were sent weekly for 3 months. Results yield that more students made progress in the text-picture personalised email group than in the control group. Students in all email groups progressed by more units than students in the control group. Only students in email groups completed the course and only students in personalised email groups reacted to the emails. Emails were accepted by most students enrolled. The findings suggest that cost-effective and easily implemented emails can encourage students to progress from unit to unit.}, language = {en} } @article{BrollGoldhackerHahneletal., author = {Broll, Alexander and Goldhacker, Markus and Hahnel, Sebastian and Rosentritt, Martin}, title = {Generative deep learning approaches for the design of dental restorations: A narrative review}, series = {Journal of Dentistry}, volume = {145}, journal = {Journal of Dentistry}, publisher = {Elsevier}, issn = {0300-5712}, doi = {10.1016/j.jdent.2024.104988}, pages = {10}, abstract = {Objectives: This study aims to explore and discuss recent advancements in tooth reconstruction utilizing deep learning (DL) techniques. A review on new DL methodologies in partial and full tooth reconstruction is conducted. Data/Sources: PubMed, Google Scholar, and IEEE Xplore databases were searched for articles from 2003 to 2023. Study selection: The review includes 9 articles published from 2018 to 2023. The selected articles showcase novel DL approaches for tooth reconstruction, while those concentrating solely on the application or review of DL methods are excluded. The review shows that data is acquired via intraoral scans or laboratory scans of dental plaster models. Common data representations are depth maps, point clouds, and voxelized point clouds. Reconstructions focus on single teeth, using data from adjacent teeth or the entire jaw. Some articles include antagonist teeth data and features like occlusal grooves and gap distance. Primary network architectures include Generative Adversarial Networks (GANs) and Transformers. Compared to conventional digital methods, DL-based tooth reconstruction reports error rates approximately two times lower. Conclusions: Generative DL models analyze dental datasets to reconstruct missing teeth by extracting insights into patterns and structures. Through specialized application, these models reconstruct morphologically and functionally sound dental structures, leveraging information from the existing teeth. The reported advancements facilitate the feasibility of DL-based dental crown reconstruction. Beyond GANs and Transformers with point clouds or voxels, recent studies indicate promising outcomes with diffusion-based architectures and innovative data representations like wavelets for 3D shape completion and inference problems. Clinical significance: Generative network architectures employed in the analysis and reconstruction of dental structures demonstrate notable proficiency. The enhanced accuracy and efficiency of DL-based frameworks hold the potential to enhance clinical outcomes and increase patient satisfaction. The reduced reconstruction times and diminished requirement for manual intervention may lead to cost savings and improved accessibility of dental services.}, language = {en} } @unpublished{SieglJungbauerGebhardtetal., author = {Siegl, Marco and Jungbauer, Bastian and Gebhardt, Jakob and Judenmann, Anna and Ehrlich, Ingo}, title = {Winding process of fibre-reinforced thermoplastic tubes with integrated tape production through in-situ roving impregnation and infrared consolidation}, series = {International Journal of Advanced Manufacturing Technology}, journal = {International Journal of Advanced Manufacturing Technology}, doi = {10.21203/rs.3.rs-4085105/v1}, abstract = {The present paper takes a novel approach to production of fibre-reinforced thermoplastic tubes. The method begins with the raw materials, reinforcing fibre and thermoplastic granulate which are processed to tapes through a newly developed direct impregnation process. It is followed by consolidation of fibre-reinforced thermoplastic tubes using infrared (IR) emitters in the filament winding process. This process employs various angles and utilizes a rotatable consolidation axis. The winding process operates at a constant speed, addressing the challenge of bending the fibre-reinforced tapes in the angle reversal areas near the tube ends. Experiments have confirmed that the process can run at speeds reaching approximately 470 mm/min. The design of the impregnation line takes into account the properties of the thermoplastic and the roving, allowing for a speed of up to 1 m/s.}, language = {en} } @article{KnoedlerDeanKnoedleretal., author = {Kn{\"o}dler, Leonard and Dean, Jillian and Knoedler, Samuel and Kauke-Navarro, Martin and Hollmann, Katharina and Alfertshofer, Michael and Helm, Sabrina and Prantl, Lukas and Schliermann, Rainer}, title = {Hard shell, soft core? Multi-disciplinary and multi-national insights into mental toughness among surgeons}, series = {Frontiers in Surgery}, volume = {11}, journal = {Frontiers in Surgery}, publisher = {Frontiers}, doi = {10.3389/fsurg.2024.1361406}, pages = {7}, abstract = {Background: With the prevalence of burnout among surgeons posing a significant threat to healthcare outcomes, the mental toughness of medical professionals has come to the fore. Mental toughness is pivotal for surgical performance and patient safety, yet research into its dynamics within a global and multi-specialty context remains scarce. This study aims to elucidate the factors contributing to mental toughness among surgeons and to understand how it correlates with surgical outcomes and personal well-being. Methods: Utilizing a cross-sectional design, this study surveyed 104 surgeons from English and German-speaking countries using the Mental Toughness Questionnaire (MTQ-18) along with additional queries about their surgical practice and general life satisfaction. Descriptive and inferential statistical analyses were applied to investigate the variations in mental toughness across different surgical domains and its correlation with professional and personal factors. Results: The study found a statistically significant higher level of mental toughness in micro-surgeons compared to macro-surgeons and a positive correlation between mental toughness and surgeons' intent to continue their careers. A strong association was also observed between general life satisfaction and mental toughness. No significant correlations were found between the application of psychological skills and mental toughness. Conclusion: Mental toughness varies significantly among surgeons from different specialties and is influenced by professional dedication and personal life satisfaction. These findings suggest the need for targeted interventions to foster mental toughness in the surgical community, potentially enhancing surgical performance and reducing burnout. Future research should continue to explore these correlations, with an emphasis on longitudinal data and the development of resilience-building programs.}, language = {en} } @article{AlBalkhyKarmaouiDucoulombieretal., author = {AlBalkhy, Wassim and Karmaoui, Dorra and Ducoulombier, Laure and Lafhaj, Zoubeir and Linner, Thomas}, title = {Digital twins in the built environment: Definition, applications, and challenges}, series = {Automation in Construction}, volume = {162}, journal = {Automation in Construction}, publisher = {Elsevier}, doi = {10.1016/j.autcon.2024.105368}, abstract = {Digital Twins (DT) implementation in the Built Environment (BE) industry is still in its early stages. Aiming to increase the knowledge about DT, this study analyzes how DT can be understood in the BE sector and investigates its different potential benefits and expected challenges. To do so, the Systematic Literature Review (SLR) approach was employed. Using 228 publications, the current study presents a proposed definition and structure for DT systems. The proposed structure is based on four main layers: physical, digital, application, and user layers. The study also classified the applications of DT into six groups: sustainability and environmental, facility management, safety, health, and risk management, structural performance, construction management, and architectural and urban-related applications. The challenges of DT implementation were also grouped based on industry-related, social and organizational, economic, technological, and political and legal challenges. Based on the results, future research directions and practical recommendations were presented to support the successful deployment of the technology.}, language = {en} } @article{MeinikheimMendelPalmetal., author = {Meinikheim, Michael and Mendel, Robert and Palm, Christoph and Probst, Andreas and Muzalyova, Anna and Scheppach, Markus W. and Nagl, Sandra and Schnoy, Elisabeth and R{\"o}mmele, Christoph and Schulz, Dominik Andreas Helmut Otto and Schlottmann, Jakob and Prinz, Friederike and Rauber, David and R{\"u}ckert, Tobias and Matsumura, Tomoaki and Fern{\´a}ndez-Esparrach, Gl{\`o}ria and Parsa, Nasim and Byrne, Michael F. and Messmann, Helmut and Ebigbo, Alanna}, title = {Influence of artificial intelligence on the diagnostic performance of endoscopists in the assessment of Barrett's esophagus: a tandem randomized and video trial}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, publisher = {Georg Thieme Verlag}, address = {Stuttgart}, doi = {10.1055/a-2296-5696}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-72818}, pages = {641 -- 649}, abstract = {Background This study evaluated the effect of an artificial intelligence (AI)-based clinical decision support system on the performance and diagnostic confidence of endoscopists in their assessment of Barrett's esophagus (BE). Methods 96 standardized endoscopy videos were assessed by 22 endoscopists with varying degrees of BE experience from 12 centers. Assessment was randomized into two video sets: group A (review first without AI and second with AI) and group B (review first with AI and second without AI). Endoscopists were required to evaluate each video for the presence of Barrett's esophagus-related neoplasia (BERN) and then decide on a spot for a targeted biopsy. After the second assessment, they were allowed to change their clinical decision and confidence level. Results AI had a stand-alone sensitivity, specificity, and accuracy of 92.2\%, 68.9\%, and 81.3\%, respectively. Without AI, BE experts had an overall sensitivity, specificity, and accuracy of 83.3\%, 58.1\%, and 71.5\%, respectively. With AI, BE nonexperts showed a significant improvement in sensitivity and specificity when videos were assessed a second time with AI (sensitivity 69.8\% [95\%CI 65.2\%-74.2\%] to 78.0\% [95\%CI 74.0\%-82.0\%]; specificity 67.3\% [95\%CI 62.5\%-72.2\%] to 72.7\% [95\%CI 68.2\%-77.3\%]). In addition, the diagnostic confidence of BE nonexperts improved significantly with AI. Conclusion BE nonexperts benefitted significantly from additional AI. BE experts and nonexperts remained significantly below the stand-alone performance of AI, suggesting that there may be other factors influencing endoscopists' decisions to follow or discard AI advice.}, language = {en} } @misc{ScheppachNunesArizietal., author = {Scheppach, Markus W. and Nunes, Danilo Weber and Arizi, X. and Rauber, David and Probst, Andreas and Nagl, Sandra and R{\"o}mmele, Christoph and Meinikheim, Michael and Palm, Christoph and Messmann, Helmut and Ebigbo, Alanna}, title = {Procedural phase recognition in endoscopic submucosal dissection (ESD) using artificial intelligence (AI)}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1783804}, pages = {S439}, abstract = {Aims Recent evidence suggests the possibility of intraprocedural phase recognition in surgical operations as well as endoscopic interventions such as peroral endoscopic myotomy and endoscopic submucosal dissection (ESD) by AI-algorithms. The intricate measurement of intraprocedural phase distribution may deepen the understanding of the procedure. Furthermore, real-time quality assessment as well as automation of reporting may become possible. Therefore, we aimed to develop an AI-algorithm for intraprocedural phase recognition during ESD. Methods A training dataset of 364385 single images from 9 full-length ESD videos was compiled. Each frame was classified into one procedural phase. Phases included scope manipulation, marking, injection, application of electrical current and bleeding. Allocation of each frame was only possible to one category. This training dataset was used to train a Video Swin transformer to recognize the phases. Temporal information was included via logarithmic frame sampling. Validation was performed using two separate ESD videos with 29801 single frames. Results The validation yielded sensitivities of 97.81\%, 97.83\%, 95.53\%, 85.01\% and 87.55\% for scope manipulation, marking, injection, electric application and bleeding, respectively. Specificities of 77.78\%, 90.91\%, 95.91\%, 93.65\% and 84.76\% were measured for the same parameters. Conclusions The developed algorithm was able to classify full-length ESD videos on a frame-by-frame basis into the predefined classes with high sensitivities and specificities. Future research will aim at the development of quality metrics based on single-operator phase distribution.}, language = {en} } @misc{ScheppachMendelRauberetal., author = {Scheppach, Markus W. and Mendel, Robert and Rauber, David and Probst, Andreas and Nagl, Sandra and R{\"o}mmele, Christoph and Meinikheim, Michael and Palm, Christoph and Messmann, Helmut and Ebigbo, Alanna}, title = {Artificial Intelligence (AI) improves endoscopists' vessel detection during endoscopic submucosal dissection (ESD)}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1782891}, pages = {S93}, abstract = {Aims While AI has been successfully implemented in detecting and characterizing colonic polyps, its role in therapeutic endoscopy remains to be elucidated. Especially third space endoscopy procedures like ESD and peroral endoscopic myotomy (POEM) pose a technical challenge and the risk of operator-dependent complications like intraprocedural bleeding and perforation. Therefore, we aimed at developing an AI-algorithm for intraprocedural real time vessel detection during ESD and POEM. Methods A training dataset consisting of 5470 annotated still images from 59 full-length videos (47 ESD, 12 POEM) and 179681 unlabeled images was used to train a DeepLabV3+neural network with the ECMT semi-supervised learning method. Evaluation for vessel detection rate (VDR) and time (VDT) of 19 endoscopists with and without AI-support was performed using a testing dataset of 101 standardized video clips with 200 predefined blood vessels. Endoscopists were stratified into trainees and experts in third space endoscopy. Results The AI algorithm had a mean VDR of 93.5\% and a median VDT of 0.32 seconds. AI support was associated with a statistically significant increase in VDR from 54.9\% to 73.0\% and from 59.0\% to 74.1\% for trainees and experts, respectively. VDT significantly decreased from 7.21 sec to 5.09 sec for trainees and from 6.10 sec to 5.38 sec for experts in the AI-support group. False positive (FP) readings occurred in 4.5\% of frames. FP structures were detected significantly shorter than true positives (0.71 sec vs. 5.99 sec). Conclusions AI improved VDR and VDT of trainees and experts in third space endoscopy and may reduce performance variability during training. Further research is needed to evaluate the clinical impact of this new technology.}, language = {en} } @misc{EbigboRauberAyoubetal., author = {Ebigbo, Alanna and Rauber, David and Ayoub, Mousa and Birzle, Lisa and Matsumura, Tomoaki and Probst, Andreas and Steinbr{\"u}ck, Ingo and Nagl, Sandra and R{\"o}mmele, Christoph and Meinikheim, Michael and Scheppach, Markus W. and Palm, Christoph and Messmann, Helmut}, title = {Early Esophageal Cancer and the Generalizability of Artificial Intelligence}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1783775}, pages = {S428}, abstract = {Aims Artificial Intelligence (AI) systems in gastrointestinal endoscopy are narrow because they are trained to solve only one specific task. Unlike Narrow-AI, general AI systems may be able to solve multiple and unrelated tasks. We aimed to understand whether an AI system trained to detect, characterize, and segment early Barrett's neoplasia (Barrett's AI) is only capable of detecting this pathology or can also detect and segment other diseases like early squamous cell cancer (SCC). Methods 120 white light (WL) and narrow-band endoscopic images (NBI) from 60 patients (1 WL and 1 NBI image per patient) were extracted from the endoscopic database of the University Hospital Augsburg. Images were annotated by three expert endoscopists with extensive experience in the diagnosis and endoscopic resection of early esophageal neoplasias. An AI system based on DeepLabV3+architecture dedicated to early Barrett's neoplasia was tested on these images. The AI system was neither trained with SCC images nor had it seen the test images prior to evaluation. The overlap between the three expert annotations („expert-agreement") was the ground truth for evaluating AI performance. Results Barrett's AI detected early SCC with a mean intersection over reference (IoR) of 92\% when at least 1 pixel of the AI prediction overlapped with the expert-agreement. When the threshold was increased to 5\%, 10\%, and 20\% overlap with the expert-agreement, the IoR was 88\%, 85\% and 82\%, respectively. The mean Intersection Over Union (IoU) - a metric according to segmentation quality between the AI prediction and the expert-agreement - was 0.45. The mean expert IoU as a measure of agreement between the three experts was 0.60. Conclusions In the context of this pilot study, the predictions of SCC by a Barrett's dedicated AI showed some overlap to the expert-agreement. Therefore, features learned from Barrett's cancer-related training might be helpful also for SCC prediction. Our results allow different possible explanations. On the one hand, some Barrett's cancer features generalize toward the related task of assessing early SCC. On the other hand, the Barrett's AI is less specific to Barrett's cancer than a general predictor of pathological tissue. However, we expect to enhance the detection quality significantly by extending the training to SCC-specific data. The insight of this study opens the way towards a transfer learning approach for more efficient training of AI to solve tasks in other domains.}, language = {en} } @misc{ZellmerRauberProbstetal., author = {Zellmer, Stephan and Rauber, David and Probst, Andreas and Weber, Tobias and Braun, Georg and R{\"o}mmele, Christoph and Nagl, Sandra and Schnoy, Elisabeth and Messmann, Helmut and Ebigbo, Alanna and Palm, Christoph}, title = {Artificial intelligence as a tool in the detection of the papillary ostium during ERCP}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Thieme}, address = {Stuttgart}, doi = {10.1055/s-0044-1783138}, pages = {S198}, abstract = {Aims Endoscopic retrograde cholangiopancreaticography (ERCP) is the gold standard in the diagnosis as well as treatment of diseases of the pancreatobiliary tract. However, it is technically complex and has a relatively high complication rate. In particular, cannulation of the papillary ostium remains challenging. The aim of this study is to examine whether a deep-learning algorithm can be used to detect the major duodenal papilla and in particular the papillary ostium reliably and could therefore be a valuable tool for inexperienced endoscopists, particularly in training situation. Methods We analyzed a total of 654 retrospectively collected images of 85 patients. Both the major duodenal papilla and the ostium were then segmented. Afterwards, a neural network was trained using a deep-learning algorithm. A 5-fold cross-validation was performed. Subsequently, we ran the algorithm on 5 prospectively collected videos of ERCPs. Results 5-fold cross-validation on the 654 labeled data resulted in an F1 value of 0.8007, a sensitivity of 0.8409 and a specificity of 0.9757 for the class papilla, and an F1 value of 0.5724, a sensitivity of 0.5456 and a specificity of 0.9966 for the class ostium. Regardless of the class, the average F1 value (class papilla and class ostium) was 0.6866, the sensitivity 0.6933 and the specificity 0.9861. In 100\% of cases the AI-detected localization of the papillary ostium in the prospectively collected videos corresponded to the localization of the cannulation performed by the endoscopist. Conclusions In the present study, the neural network was able to identify the major duodenal papilla with a high sensitivity and high specificity. In detecting the papillary ostium, the sensitivity was notably lower. However, when used on videos, the AI was able to identify the location of the subsequent cannulation with 100\% accuracy. In the future, the neural network will be trained with more data. Thus, a suitable tool for ERCP could be established, especially in the training situation.}, language = {en} } @article{FrankeWagner, author = {Franke, Markus and Wagner, Marcus}, title = {Transient surrogate modeling of modally reduced structures with discontinuous loads and damping}, series = {Archive of Applied Mechanics}, volume = {94}, journal = {Archive of Applied Mechanics}, number = {5}, publisher = {Springer Nature}, doi = {10.1007/s00419-024-02601-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-72834}, pages = {20}, abstract = {In this work, a surrogate model for structural, transient and discontinuously excited finite element method simulations is developed. This allows to reduce the computational effort of repeated calculations of identical models under different load cases. The architecture of the surrogate combines fully connected neural network layers with long short-term memory layers. For the reproduction of different damping ratios, a categorical variable is added to the continuous input data. Based on a recursive flow of the predicted data back to the input layer, long-term dependencies do not vanish due to short-input sequences. The system dimension is reduced by applying the model-order reduction technique for modal decomposition. The high accuracy of the surrogate and the reduction of computational costs are shown on an academic example of a cantilever beam and a real-world example of a robot. The advantages of our approach are illustrated in comparison with state-of-the-art surrogates for transient finite element analysis. By using the surrogate proposed in this study, oscillations due to discontinuous excitation of mechanical structures can be reproduced. For this purpose, only short-input sequences are necessary since the excitation of the oscillations does not have to be part of the input sequence during the whole duration of the oscillations. Due to the categorical variable for the damping ratio, the surrogate can account for the influence of different damping in parameter studies.}, language = {en} } @article{KaessBrosigWestneretal., author = {K{\"a}ss, Sebastian and Brosig, Christoph and Westner, Markus and Strahringer, Susanne}, title = {Short and sweet: multiple mini case studies as a form of rigorous case study research}, series = {Information Systems and e-Business Management}, journal = {Information Systems and e-Business Management}, publisher = {Springer Nature}, doi = {10.1007/s10257-024-00674-2}, pages = {34}, abstract = {Case study research is one of the most widely used research methods in Information Systems (IS). In recent years, an increasing number of publications have used case studies with few sources of evidence, such as single interviews per case. While there is much methodological guidance on rigorously conducting multiple case studies, it remains unclear how researchers can achieve an acceptable level of rigour for this emerging type of multiple case study with few sources of evidence, i.e., multiple mini case studies. In this context, we synthesise methodological guidance for multiple case study research from a cross-disciplinary perspective to develop an analytical framework. Furthermore, we calibrate this analytical framework to multiple mini case studies by reviewing previous IS publications that use multiple mini case studies to provide guidelines to conduct multiple mini case studies rigorously. We also offer a conceptual definition of multiple mini case studies, distinguish them from other research approaches, and position multiple mini case studies as a pragmatic and rigorous approach to research emerging and innovative phenomena in IS.}, language = {en} } @misc{RoserMeinikheimMendeletal., author = {Roser, David and Meinikheim, Michael and Mendel, Robert and Palm, Christoph and Probst, Andreas and Muzalyova, Anna and Scheppach, Markus W. and Nagl, Sandra and Schnoy, Elisabeth and R{\"o}mmele, Christoph and Schulz, Dominik Andreas Helmut Otto and Schlottmann, Jakob and Prinz, Friederike and Rauber, David and R{\"u}ckert, Tobias and Matsumura, Tomoaki and Fernandez-Esparrach, G. and Parsa, Nasim and Byrne, Michael F. and Messmann, Helmut and Ebigbo, Alanna}, title = {Human-Computer Interaction: Impact of Artificial Intelligence on the diagnostic confidence of endoscopists assessing videos of Barrett's esophagus}, series = {Endoscopy}, volume = {56}, journal = {Endoscopy}, number = {S 02}, publisher = {Georg Thieme Verlag}, issn = {1438-8812}, doi = {10.1055/s-0044-1782859}, pages = {79}, abstract = {Aims Human-computer interactions (HCI) may have a relevant impact on the performance of Artificial Intelligence (AI). Studies show that although endoscopists assessing Barrett's esophagus (BE) with AI improve their performance significantly, they do not achieve the level of the stand-alone performance of AI. One aspect of HCI is the impact of AI on the degree of certainty and confidence displayed by the endoscopist. Indirectly, diagnostic confidence when using AI may be linked to trust and acceptance of AI. In a BE video study, we aimed to understand the impact of AI on the diagnostic confidence of endoscopists and the possible correlation with diagnostic performance. Methods 22 endoscopists from 12 centers with varying levels of BE experience reviewed ninety-six standardized endoscopy videos. Endoscopists were categorized into experts and non-experts and randomly assigned to assess the videos with and without AI. Participants were randomized in two arms: Arm A assessed videos first without AI and then with AI, while Arm B assessed videos in the opposite order. Evaluators were tasked with identifying BE-related neoplasia and rating their confidence with and without AI on a scale from 0 to 9. Results The utilization of AI in Arm A (without AI first, with AI second) significantly elevated confidence levels for experts and non-experts (7.1 to 8.0 and 6.1 to 6.6, respectively). Only non-experts benefitted from AI with a significant increase in accuracy (68.6\% to 75.5\%). Interestingly, while the confidence levels of experts without AI were higher than those of non-experts with AI, there was no significant difference in accuracy between these two groups (71.3\% vs. 75.5\%). In Arm B (with AI first, without AI second), experts and non-experts experienced a significant reduction in confidence (7.6 to 7.1 and 6.4 to 6.2, respectively), while maintaining consistent accuracy levels (71.8\% to 71.8\% and 67.5\% to 67.1\%, respectively). Conclusions AI significantly enhanced confidence levels for both expert and non-expert endoscopists. Endoscopists felt significantly more uncertain in their assessments without AI. Furthermore, experts with or without AI consistently displayed higher confidence levels than non-experts with AI, irrespective of comparable outcomes. These findings underscore the possible role of AI in improving diagnostic confidence during endoscopic assessment.}, language = {en} } @article{LehrerKapsLepeniesetal., author = {Lehrer, Tobias and Kaps, Arne and Lepenies, Ingolf and Raponi, Elena and Wagner, Marcus and Duddeck, Fabian}, title = {Complementing Drawability Assessment of Deep-Drawn Components with Surrogate-Based Global Sensitivity Analysis}, series = {ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering}, journal = {ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part B: Mechanical Engineering}, publisher = {ASME}, issn = {2332-9025}, doi = {10.1115/1.4065143}, pages = {1 -- 10}, abstract = {In the early-stage development of sheet metal parts, key design properties of new structures must be specified. As these decisions are made under significant uncertainty regarding drawing configuration changes, they sometimes result in the development of new parts that, at a later design stage, will not be drawable. As a result, there is a need to increase the certainty of experience-driven drawing configuration decisions. Complementing this process with a global sensitivity analysis can provide insight into the impact of various changes in drawing configurations on drawability, unveiling cost-effective strategies to ensure the drawability of new parts. However, when quantitative global sensitivity approaches, such as Sobol's method, are utilized, the computational requirements for obtaining Sobol indices can become prohibitive even for small application problems. To circumvent computational limitations, we evaluate the applicability of different surrogate models engaged in computing global design variable sensitivities for the drawability assessment of a deep-drawn component. Here, we show in an exemplary application problem, that both a standard kriging model and an ensemble model can provide commendable results at a fraction of the computational cost. Moreover, we compare our surrogate models to existing approaches in the field. Furthermore, we show that the error introduced by the surrogate models is of the same order of magnitude as that from the choice of drawability measure. In consequence, our surrogate models can improve the cost-effective development of a component in the early design phase.}, language = {en} } @inproceedings{VoelklMelzerDuennweberetal., author = {V{\"o}lkl, Jakob and Melzer, Matthias and D{\"u}nnweber, Jan and Sarkar, Amitrajit}, title = {Dynamic Route Planning for a Data Collecting Luggage Transport Service}, series = {18th IEEE International Conference on Control \& Automation, June 18-21, 2024, Reykjav{\´i}k, Iceland}, booktitle = {18th IEEE International Conference on Control \& Automation, June 18-21, 2024, Reykjav{\´i}k, Iceland}, publisher = {IEEE}, abstract = {Control and Automation of services of the urban infrastructure offered to citizens and tourists are elementary parts of a smart city. But both rely on a stable supply of data from sensors spread across the whole city, e. g., the fill level sensors of waste bins needed for a waste management tool which we developed in a collaboration with the Regensburg city council for the on-demand collection of waste bins. Europe has a lot of historic cities like Regensburg with narrow streets and huge building walls, some made from granite and fieldstones, which often represents an insurmountable obstacle to wireless data transmission. The reduction of the road traffic volume poses an additional challenge for city planners. By means of networked planning and simulation software, the situation, state and efficiency of citywide logistic services can be monitored and optimized. In the course of such optimizations, we propose the combination of digital and logistic services. As an example, we show that monitoring state information, such as the waste bin fill levels, can be accomplished using the same vehicles and the same planning software, that is used for luggage transportation. Moreover, we describe how we adapted a solver for a variant of the TSP, namely the prize-collecting traveling salesman, to optimize the route planning dynamically.}, language = {en} } @article{BuchnerHausladenBartletal., author = {Buchner, Philipp and Hausladen, Matthias and Bartl, Mathias and Bachmann, Michael and Schreiner, Rupert}, title = {High current field emission from Si nanowires on pillar structures}, series = {Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics}, volume = {42}, journal = {Journal of Vacuum Science and Technology B: Nanotechnology and Microelectronics}, number = {2}, publisher = {AIP}, issn = {2166-2754}, doi = {10.1116/6.0003384}, abstract = {We investigate the influence of the geometry and doping level on the performance of n-type silicon nanowire field emitters on silicon pillar structures. Therefore, multiple cathodes with 50 by 50 pillar arrays (diameter: 5 μm, height: 30 μm, spacing: 50 μm) were fabricated and measured in diode configuration. In the first experiment, we compared two geometry types using the same material. Geometry 1 is black silicon, which is a highly dense surface covering a forest of tightly spaced silicon needles resulting from self-masking during a plasma etching process of single crystal silicon. Geometry 2 are silicon nanowires, which are individual spaced-out nanowires in a crownlike shape resulting from a plasma etching process of single crystal silicon. In the second experiment, we compared two different silicon doping levels [n-type (P), 1-10 and <0.005 Ω cm] for the same geometry. The best performance was achieved with lower doped silicon nanowire samples, emitting 2 mA at an extraction voltage of 1 kV. The geometry/material combination with the best performance was used to assemble an integrated electron source. These electron sources were measured in a triode configuration and reached onset voltages of about 125 V and emission currents of 2.5 mA at extraction voltages of 400 V, while achieving electron transmission rates as high as 85.0\%.}, language = {en} } @article{SchudererRillSchaefferetal., author = {Schuderer, Matthias and Rill, Georg and Schaeffer, Thomas and Schulz, Carsten}, title = {Friction modeling from a practical point of view}, series = {Multibody System Dynamics}, journal = {Multibody System Dynamics}, publisher = {Springernature}, issn = {1384-5640}, doi = {10.1007/s11044-024-09978-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-72513}, pages = {18}, abstract = {AbstractRegularized static friction models have been used successfully for many years. However, they are unable to maintain static friction in detail. For this reason, dynamic friction models have been developed and published in the literature. However, commercial multibody simulation packages such as Adams, RecurDyn, and Simpack have developed their own specific stick-slip models instead of adopting one of the public domain approaches. This article introduces the fundamentals of these commercial models and their behavior from a practical point of view. The stick-slip models were applied to a simple test model and a more sophisticated model of a festoon cable system using their standard parameters.}, language = {en} } @article{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An inexpensive UV-LED photoacoustic based real-time sensor-system detecting exhaled trace-acetone}, series = {Photoacoustics}, volume = {38}, journal = {Photoacoustics}, publisher = {Elsevier}, issn = {2213-5979}, doi = {10.1016/j.pacs.2024.100604}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-71279}, pages = {12}, abstract = {n this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 8.3 ppbV and an NNEA of 1.4E-9 Wcm 1Hz 0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} } @unpublished{PangerlSukulRuecketal., author = {Pangerl, Jonas and Sukul, Pritam and R{\"u}ck, Thomas and Fuchs, Patricia and Weigl, Stefan and Miekisch, Wolfram and Bierl, Rudolf and Matysik, Frank-Michael}, title = {An Inexpensive Uv-Led Photoacoustic Based Real-Time Sensor-System Detecting Exhaled Trace-Acetone}, publisher = {Elsevier}, doi = {10.2139/ssrn.4724198}, abstract = {In this research we present a low-cost system for breath acetone analysis based on UV-LED photoacoustic spectroscopy. We considered the end-tidal phase of exhalation, which represents the systemic concentrations of volatile organic compounds (VOCs) - providing clinically relevant information about the human health. This is achieved via the development of a CO2-triggered breath sampling system, which collected alveolar breath over several minutes in sterile and inert containers. A real-time mass spectrometer is coupled to serve as a reference device for calibration measurements and subsequent breath analysis. The new sensor system provided a 3σ detection limit of 6.4 ppbV and an NNEA of 1.1E-9 Wcm-1Hz-0.5. In terms of the performed breath analysis measurements, 12 out of 13 fell within the error margin of the photoacoustic measurement system, demonstrating the reliability of the measurements in the field.}, language = {en} }