@misc{AurbachSpickaSuessetal., author = {Aurbach, Maximilian and Spicka, Jan and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Musculoskeletal modelling of the shoulder - effects on muscle recruitment and joint reaction force}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @misc{KubowitschSuessJansenetal., author = {Kubowitsch, Simone and S{\"u}ß, Franz and Jansen, Petra and Dendorfer, Sebastian}, title = {Effect of dual tasking on muscular imbalances}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @misc{EngelhardtMelznerHavelkovaetal., author = {Engelhardt, Lucas and Melzner, Maximilian and Havelkova, Linda and Fiala, Pavel and Rybarova, Martina and Christen, Patrik and Dendorfer, Sebastian and Simon, Ulrich}, title = {A new musculoskeletal AnyBody detailed hand model}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, abstract = {The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.}, language = {en} } @inproceedings{SuessKubowitschRasmussenetal., author = {S{\"u}ß, Franz and Kubowitsch, Simone and Rasmussen, John and Verkerke, Gijsbertus Jacob and Dendorfer, Sebastian}, title = {The influence of cognitive stress on muscle activation and spinal disc load}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, booktitle = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @misc{AuerNieblerEiglspergeretal., author = {Auer, Simon and Niebler, Michael and Eiglsperger, Josef and Kubowitsch, Simone and Renkawitz, Tobias and Achenbach, Leonard and Krutsch, Werner and Dendorfer, Sebastian}, title = {Cognitive stress increases muscle forces in dynamic football specific movements}, series = {European Society of Biomechanics meeting 2019, Vienna, Austria}, journal = {European Society of Biomechanics meeting 2019, Vienna, Austria}, language = {en} } @inproceedings{MelznerEngelhardtHavelkovaetal., author = {Melzner, Maximilian and Engelhardt, Lucas and Havelkova, Leonard and Simon, Ulrich and Dendorfer, Sebastian}, title = {A new musculoskeletal AnyBody detailed hand model validated by electromyography}, series = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, booktitle = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, abstract = {The AnyBody™ Modeling System (AMS) [1], is an universally used musculoskeletal simulation software using inverse dynamics. Until now, no complete human hand model is known in the AMS. Also considering other musculoskeletal software platforms, just one detailed entire hand model is recently published [2] but is only based on one subject. The aim of this work is to implement a full detailed hand model for the AMS including all extrinsic and intrinsic muscles using data by the UWB gained through an anatomical study of ten cadaver hands.}, language = {en} } @misc{AurbachSuessDendorfer, author = {Aurbach, Maximilian and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {The impact of the hill type muscle model on the glenohumeral joint reaction force}, series = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, journal = {16th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering (CMBBE) 2019, New York City, USA}, language = {en} } @misc{Dendorfer, author = {Dendorfer, Sebastian}, title = {Virtuelle Modelle der oberen Extremit{\"a}t}, series = {22. Interdisziplin{\"a}res Symposium Medizin-Physiotherapie-Sportwissenschaften, 22.-23.11.2019, Regensburg, Germany}, journal = {22. Interdisziplin{\"a}res Symposium Medizin-Physiotherapie-Sportwissenschaften, 22.-23.11.2019, Regensburg, Germany}, language = {de} } @misc{Dendorfer, author = {Dendorfer, Sebastian}, title = {The influence of mental stress on the musculoskeletal system}, language = {en} } @misc{MelznerEngelhardtSuessetal., author = {Melzner, Maximilian and Engelhardt, Leonard and S{\"u}ß, Friedrich and Dendorfer, Sebastian}, title = {Sensitivity evaluation of a musculoskeletal hand model using Latin hypercube sampling}, series = {ESMAC 2020 Abstracts}, volume = {81}, journal = {ESMAC 2020 Abstracts}, number = {Suppl. 1}, publisher = {Elsevier}, doi = {10.1016/j.gaitpost.2020.08.008}, language = {en} } @article{AuerKrutschRenkawitzetal., author = {Auer, Simon and Krutsch, Werner and Renkawitz, Tobias and Kubowitsch, Simone and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Kognitiver Stress f{\"u}hrt zu unphysiologisch erh{\"o}hten Kniebelastungen im Profifußball}, series = {Sports Orthopaedics and Traumatology}, volume = {36}, journal = {Sports Orthopaedics and Traumatology}, number = {2}, publisher = {Elsevier}, doi = {10.1016/j.orthtr.2020.04.122}, pages = {202 -- 203}, language = {de} } @misc{AuerKrutschRenkawitzetal., author = {Auer, Simon and Krutsch, Werner and Renkawitz, Tobias and Kubowitsch, Simone and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Effect of mental demand on leg loading in highly dynamic motion}, series = {AnyBody online Webinar, Oct 2020}, journal = {AnyBody online Webinar, Oct 2020}, abstract = {Football players have a high risk of leg muscle injuries, especially when exposed to mental stress. Injuries to muscles of the thigh are common in amateur and professional football, representing almost a third of all injuries. These injuries occur primarily in non-contact situations and from overuse. They can lead to a range of costs, including financial costs associated with treatment as well as those associated with long-term recovery, and absence from training and/or competition. Further, there is a high risk of injury recurrence and subsequent injury.}, language = {en} } @misc{MelznerPfeiferAltetal., author = {Melzner, Maximilian and Pfeifer, Christian and Alt, V. and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {{\"A}nderung der Gelenkreaktionskraft bei Sch{\"a}digung des medialen Bandapparates im Ellenbogen}, series = {Zeitschrift fur Orthopadie und Unfallchirurgie}, volume = {158}, journal = {Zeitschrift fur Orthopadie und Unfallchirurgie}, number = {S01}, publisher = {Thieme}, doi = {10.1055/s-0040-1717270}, language = {de} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {Biomechanical evaluation and optimisation of countermeasure exercises}, series = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, booktitle = {ESA/ESTEC Bedrest Strategy Workshop, Noordwijk, NL, 2009}, language = {en} } @inproceedings{Dendorfer, author = {Dendorfer, Sebastian}, title = {How much iron to pump? The determination of muscle forces for activities of daily living}, series = {DGU, Berlin, 2008}, booktitle = {DGU, Berlin, 2008}, language = {en} } @inproceedings{HammerDendorfer, author = {Hammer, Joachim and Dendorfer, Sebastian}, title = {Cyclic loading and microstructure of cancellous bone}, series = {Journal of Biomechanics}, volume = {41}, booktitle = {Journal of Biomechanics}, number = {Suppl. 1, July 2008}, doi = {10.1016/S0021-9290(08)70409-3}, pages = {S410}, language = {en} } @inproceedings{DendorferKubowitsch, author = {Dendorfer, Sebastian and Kubowitsch, Simone}, title = {The interaction of mental stress and biomechanics}, series = {Health Technology Triangle, Weiden, 2016}, booktitle = {Health Technology Triangle, Weiden, 2016}, language = {en} } @article{WeberMerleNawabietal., author = {Weber, Markus and Merle, Christian and Nawabi, Danyal H. and Dendorfer, Sebastian and Grifka, Joachim and Renkawitz, Tobias}, title = {Inaccurate offset restoration in total hip arthroplasty results in reduced range of motion}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, number = {13208}, publisher = {Nature}, doi = {10.1038/s41598-020-70059-1}, pages = {9}, abstract = {Offset restoration in total hip arthroplasty (THA) is associated with postoperative range of motion (ROM) and gait kinematics. We aimed to research into the impact of high offset (HO) and standard stems on postoperative ROM. 121 patients received cementless THA through a minimally-invasive anterolateral approach. A 360° hip ROM analysis software calculated impingement-free hip movement based on postoperative 3D-CTs compared to ROM values necessary for activities of daily living (ADL). The same model was then run a second time after changing the stem geometry between standard and HO configuration with the implants in the same position. HO stems showed higher ROM for all directions between 4.6 and 8.9° (p < 0.001) compared with standard stems but with high interindividual variability. In the subgroup with HO stems for intraoperative offset restoration, the increase in ROM was even higher for all ROM directions with values between 6.1 and 14.4° (p < 0.001) compared to offset underrestoration with standard stems. Avoiding offset underrestoration resulted in a higher amount of patients of over 20\% for each ROM direction that fulfilled the criteria for ADL (p < 0.001). In contrast, in patients with standard stems for offset restoration ROM did increase but not clinically relevant by offset overcorrection for all directions between 3.1 and 6.1° (p < 0.001). Offset overcorrection by replacing standard with HO stems improved ROM for ADL in a low number of patients below 10\% (p > 0.03). Patient-individual restoration of offset is crucial for free ROM in THA. Both over and underrestoration of offset should be avoided.}, language = {en} } @article{AurbachŠpičkaSuessetal., author = {Aurbach, Maximilian and Špička, Jan and S{\"u}ß, Franz and Vychytil, J. and Havelkov{\´a}, Leonard and Ryba, T. and Dendorfer, Sebastian}, title = {Torus obstacle method as a wrapping approach of the deltoid muscle group for humeral abduction in musculoskeletal simulation}, series = {Journal of Biomechanics}, volume = {109}, journal = {Journal of Biomechanics}, number = {August}, publisher = {Elsevier}, doi = {10.1016/j.jbiomech.2020.109864}, abstract = {Musculoskeletal models of the shoulder complex are valuable research aids to investigate tears of the supraspinatus and the resulting mechanical impact during abduction of the humerus. One of the major contributors to this motion is the deltoid muscle group and for this, an accurate modeling of the lines of action is indispensable. The aim of this work was to utilize a torus obstacle wrapping approach for the deltoids of an existing shoulder model and assess the feasibility of the approach during humeral abduction. The shoulder model from the AnyBody™ modeling system was used as a platform. The size of the tori is based on a magnetic resonance imaging (MRI) approach and several kinematic couplings are implemented to determine the trajectories of the tori during abduction. To assess the model behavior, the moment arms of the virtual muscle elements and the resultant glenohumeral joint reaction force (GHJF) were compared with reference data from the literature during abduction of the humerus in the range 20°-120°. The root mean square error for the anterior, lateral and posterior part between the simulated muscle elements and reference data from the literature was 3.9, 1.7 and 5.8 mm, respectively. The largest deviation occurred on the outer elements of the muscle groups, with 12.6, 10.4 and 20.5 mm, respectively. During abduction, there is no overlapping of the muscle elements and these are in continuous contact with the torus obstacles, thus enabling a continuous force transmission. This results in a rising trend of the resultant GHJF. The torus obstacle approach as a wrapping method for the deltoid muscles provides a guided muscle pathing by simultaneously approximating the curvature of the deltoid muscle. The results from the comparison of the simulated moment arms and the resultant GHJF are in accordance with those in the literature in the range 20°-120° of abduction. Although this study shows the strength of the torus obstacle as a wrapping approach, the method of fitting the tori according to MRI data was not suitable. A cadaver study is recommended to better validate and mathematically describe the torus approach.}, language = {en} } @inproceedings{AuerKubowitschKrutschetal., author = {Auer, Simon and Kubowitsch, Simone and Krutsch, Werner and Renkawitz, Tobias and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Effect of mental demand on knee forces in professional youth soccer players}, series = {ISBS Proceedings Archive}, volume = {38}, booktitle = {ISBS Proceedings Archive}, number = {1, Art. 28}, abstract = {Soccer is one of the most popular sports all around the world. It is an injurious type of sport with a focus on lower extremities and high psychological pressure during matches. The stressor is linked with injuries and an increased musculoskeletal loading. This study investigates the influence of cognitive stress on the load profile of the knee joint. Twelve professional youth soccer players performed highly dynamic runs with and without additional cognitive stress. The runs were analysed with a musculoskeletal simulation software. The data analysis shows no difference in knee joint reaction loading under additional mental stress compared to the baseline. Yet running times are significantly lower in the baseline. While there is no increase in the joint loads, the running times indicate an altered movement behaviour when the subjects are exposed to additional mental demand.}, subject = {Kniegelenk}, language = {en} } @book{Galka, author = {Galka, Stefan}, title = {AutoStore - was Nutzer {\"u}ber das System berichten k{\"o}nnen}, address = {Regensburg}, isbn = {978-3-9818209-9-7}, doi = {10.35096/othr/pub-646}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-6463}, publisher = {Ostbayerische Technische Hochschule Regensburg}, subject = {Kleinteil}, language = {de} } @misc{HornbergerThielVollmann, author = {Hornberger, Helga and Thiel, Norbert and Vollmann, Markus}, title = {Fully ceramic tooth replacement with a frame made of cer-stabilised zircon-oxide}, pages = {8}, abstract = {Vollkeramischer Zahnersatz mit einem Ger{\"u}st, das aus einem Ger{\"u}stmaterial aus einem Cer-stabilisierten Zirkonoxid (Ce-ZrO2) mit einem Anteil von bis zu 25 Gew\% Aluminiumoxid (Al2O3) bezogen auf den Anteil an ZrO2 aufgebaut ist und einem Infiltrationsglasanteil im Ger{\"u}st von 0-40 Vol\% bezogen auf das Volumen des Ger{\"u}sts sowie einer auf das Ger{\"u}stmaterial abgestimmten Verblendkeramik.Die Erfindung betrifft die Verwendung von cer-stabilisiertem ZrO2 zur Herstellung von Ger{\"u}stmaterialien, die als Restauration im Dentalbereich einsetzbar sind.}, language = {en} } @misc{AechtnerHornbergerNageletal., author = {Aechtner, Stefan and Hornberger, Helga and Nagel, Emil and Thiel, Norbert}, title = {Composite material and method for the preparation thereof}, pages = {5}, abstract = {A composite material with a porous inorganic-nonmetallic matrix and a second material, characterized in that said porous inorganic-nonmetallic matrix has a bending strength of >=40 MPa as measured according to ISO 6 872; said second material is an organic material which at least partly fills the pores of said porous matrix; and said composite material has a modulus of elasticity, E, of >=25 GPa as measured according to ISO 10 477.}, language = {en} } @misc{MuerrleHornberger, author = {Muerrle, Ulrich and Hornberger, Helga}, title = {Method of making a ceramic restoration}, pages = {8}, abstract = {Production of a dental reconstruction comprises: (a) forming a mold (12) from a model (10); (b) using (12) to make an isotropically heat-expandable replica from a ceramic precursor (14); (c) oxidizing (14) to produce an enlarged ceramic replica; (d) forming a silicone mold from this replica; (e) using (d) to make a second ceramic replica; and (f) sintering the second replica with volume reduction to form a replica identical to (10).}, language = {en} } @article{HornbergerMarquisFranks, author = {Hornberger, Helga and Marquis, Peter M. and Franks, J.}, title = {The impact of diamond-like coatings on the strength of dental ceramics}, series = {Journal of Dental Research}, volume = {74}, journal = {Journal of Dental Research}, pages = {522}, language = {en} } @article{HornbergerMarquisChristiansenetal., author = {Hornberger, Helga and Marquis, Peter M. and Christiansen, Silke H. and Albrecht, Manuel and Strunk, Horst P. and Franks, J.}, title = {Microstructure of a high strength alumina-glass composite combined with a diamond like carbon coating}, series = {Electron Microscopy and Analysis}, journal = {Electron Microscopy and Analysis}, doi = {10.1557/JMR.1996.0244}, pages = {559 -- 562}, abstract = {We investigate the mechanical and microstructural properties of a diamond-like carbon coating (DLC) which is deposited by plasma enhanced chemical vapor deposition (PECVD) onto an alumina/aluminosilicate glass composite used for biomedical applications. Ball-on-ring tests yield a fracture strength that is essentially influenced by the surface topology/roughness. The surface topology of the coating is investigated by atomic force microscopy (AFM). Tribology tests and nanoindentation represent the wear resistance and hardness; these are properties that are mainly influenced by the microstructural properties of the DLC coating. This microstructure is investigated by transmission electron microscopy (TEM) and analyzed by parallel electron energy loss spectroscopy (PEELS). For the general applicability of the coated composite, the interfacial adhesion of the DLC coating on the comparably rough substrate (roughness amplitudes and wavelengths are in the micrometer range) is important. Therefore, we focus on TEM investigations that show the interface to be free of gaps and pores that we, together with a characteristic microstructure adjacent to the interface, relate to the excellent adhesion. The interlayer consists of a high density of SiC grains, part of them directly bound to the substrate, and part of them bound to other SiC grains. This interlayer is followed by an essentially different region of the coating as concerns the microstructure; this region consists of nanocrystalline diamond particles embedded in an amorphous carbon matrix. It is this heterogeneous microstructure to which we attribute (i) the good adhesion based upon the interface stabilizing SiC grains, and (ii) the high hardness and wear resistance based upon the diamond nanocrystals in the coating.}, language = {en} } @article{HornbergerMarquis, author = {Hornberger, Helga and Marquis, Peter M.}, title = {Mechanical properties and microstructure of In-Ceram}, series = {Glastechnische Berichte - Glass Science and Technology}, volume = {68}, journal = {Glastechnische Berichte - Glass Science and Technology}, number = {6}, pages = {188 -- 194}, language = {en} } @article{HornbergerWeissmannLutz, author = {Hornberger, Helga and Weissmann, R. and Lutz, N.}, title = {Machining of silica glasses using excimer laser radiation}, series = {Glastechnische Berichte - Glass Science and Technology}, volume = {69}, journal = {Glastechnische Berichte - Glass Science and Technology}, number = {2}, pages = {44 -- 49}, language = {en} } @article{HornbergerMarquisChristiansenetal., author = {Hornberger, Helga and Marquis, Peter M. and Christiansen, Silke H. and Strunk, Horst P.}, title = {Microstructure of a high strength alumina glass composite}, series = {Journal of Materials Research}, volume = {11}, journal = {Journal of Materials Research}, number = {4}, doi = {10.1557/JMR.1996.0104}, pages = {855 -- 858}, abstract = {The morphology and microstructure of an Al2O3 glass composite (trade name In-Ceram, Vita Zahnfabrik) were studied using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The composite was produced by infiltration of a lanthanum-based glass throughout a porous Al2O3 body. This alumina body was formed by three classes of particles differing in size and shape: faceted particles typically ≤4 μm in diameter, platelets of average diameter 8 μm, 1.5 μm thickness, and small spheres 0.4 μm in diameter. The outstanding strength properties of the composite (600 MPa, ball-on-ring test) are a result of the high wetting capability of the glass phase on the Al2O3 surface. In addition, plastic strain relaxation in the faceted particles by dislocation formation compensates partially for residual stresses and impedes crack formation at the glass/Al2O3 interface.}, language = {en} } @article{ChristiansenAlbrechtStrunketal., author = {Christiansen, Silke H. and Albrecht, Manuel and Strunk, Horst P. and Hornberger, Helga and Marquis, Peter M. and Franks, J.}, title = {Mechanical properties and microstructural analysis of a diamond-like carbon coating on an alumina/glass composite}, series = {Journal of Materials Research}, volume = {11}, journal = {Journal of Materials Research}, number = {8}, doi = {10.1557/JMR.1996.0244}, pages = {1934 -- 1942}, abstract = {We investigate the mechanical and microstructural properties of a diamond-like carbon coating (DLC) which is deposited by plasma enhanced chemical vapor deposition (PECVD) onto an alumina/aluminosilicate glass composite used for biomedical applications. Ball-on-ring tests yield a fracture strength that is essentially influenced by the surface topology/roughness. The surface topology of the coating is investigated by atomic force microscopy (AFM). Tribology tests and nanoindentation represent the wear resistance and hardness; these are properties that are mainly influenced by the microstructural properties of the DLC coating. This microstructure is investigated by transmission electron microscopy (TEM) and analyzed by parallel electron energy loss spectroscopy (PEELS). For the general applicability of the coated composite, the interfacial adhesion of the DLC coating on the comparably rough substrate (roughness amplitudes and wavelengths are in the micrometer range) is important. Therefore, we focus on TEM investigations that show the interface to be free of gaps and pores that we, together with a characteristic microstructure adjacent to the interface, relate to the excellent adhesion. The interlayer consists of a high density of SiC grains, part of them directly bound to the substrate, and part of them bound to other SiC grains. This interlayer is followed by an essentially different region of the coating as concerns the microstructure; this region consists of nanocrystalline diamond particles embedded in an amorphous carbon matrix. It is this heterogeneous microstructure to which we attribute (i) the good adhesion based upon the interface stabilizing SiC grains, and (ii) the high hardness and wear resistance based upon the diamond nanocrystals in the coating.}, language = {en} } @article{ReichHornberger, author = {Reich, Sven and Hornberger, Helga}, title = {The effect of multicolored machinable ceramics on the esthetics of all-ceramic crowns}, series = {Journal of Prosthetic Dentistry}, volume = {88}, journal = {Journal of Prosthetic Dentistry}, number = {1}, pages = {44 -- 49}, abstract = {Statement of problems: Computer-aided design/computer-assisted machining systems offer the possibility of fabricating restorations from one machinable ceramic block. Whether multishaded blocks improve esthetic results and are a viable alternative to individually stained ceramics has not been fully determined. Purpose: The aim of this investigation was to examine the effect of multishaded blocks on the esthetic appearance of all-ceramic CEREC crowns and compare these crowns with single-shade and stained restorations. Material and methods: Ten subjects were included in this study. For each subject, 6 different crowns were milled with the use of a CEREC machine. One crown was milled from each of the following machinable ceramic materials: CEREC Vitablocs Mark II in classic colors; Vitablocs Mark II in 3D-Master colors; Vitablocs Mark II in either classic or 3D-Master colors, with additional staining; Megadenta Bloxx multishaded; Mark II experimental multilayer; and an experimental multilayer leucite ceramic. Three independent examiners assessed the esthetic appearance of crowns fabricated to match each subject's anterior tooth shade. A scale of 1 to 6 was used to score the shade match and esthetic adaptation of each crown, with 1 representing excellent characteristics and 3.5 serving as the threshold for clinical acceptability. The examiners' scores were averaged, and the mean values were analyzed with the Wilcoxon signed rank test (P