@article{AuerSuessDendorfer, author = {Auer, Simon and S{\"u}ß, Franz and Dendorfer, Sebastian}, title = {Using markerless motion capture and musculoskeletal models: An evaluation of joint kinematics}, series = {Technology and Health Care}, journal = {Technology and Health Care}, publisher = {IOS Press}, issn = {0928-7329}, doi = {10.3233/THC-240202}, pages = {1 -- 10}, abstract = {BACKGROUND: This study presents a comprehensive comparison between a marker-based motion capture system (MMC) and a video-based motion capture system (VMC) in the context of kinematic analysis using musculoskeletal models. OBJECTIVE: Focusing on joint angles, the study aimed to evaluate the accuracy of VMC as a viable alternative for biomechanical research. METHODS: Eighteen healthy subjects performed isolated movements with 17 joint degrees of freedom, and their kinematic data were collected using both an MMC and a VMC setup. The kinematic data were entered into the AnyBody Modelling System, which enables the calculation of joint angles. The mean absolute error (MAE) was calculated to quantify the deviations between the two systems. RESULTS: The results showed good agreement between VMC and MMC at several joint angles. In particular, the shoulder, hip and knee joints showed small deviations in kinematics with MAE values of 4.8∘, 6.8∘ and 3.5∘, respectively. However, the study revealed problems in tracking hand and elbow movements, resulting in higher MAE values of 13.7∘ and 27.7∘. Deviations were also higher for head and thoracic movements. CONCLUSION: Overall, VMC showed promising results for lower body and shoulder kinematics. However, the tracking of the wrist and pelvis still needs to be refined. The research results provide a basis for further investigations that promote the fusion of VMC and musculoskeletal models.}, language = {en} } @article{SaffertMelznerDendorfer, author = {Saffert, Anne-Sophie and Melzner, Maximilian and Dendorfer, Sebastian}, title = {Biomechanical analysis of the right elevated glenohumeral joint in violinists during legato-playing}, series = {Technology and Health Care}, volume = {30}, journal = {Technology and Health Care}, number = {1}, publisher = {IOS Press}, doi = {10.3233/THC-219001}, pages = {177 -- 186}, abstract = {BACKGROUND: Many statistics reveal that violin players suffer most often from musculoskeletal disorders compared to musicians of other instrument groups. A common phenomenon, especially observed in violin beginners, is the tendency to elevate the right shoulder during playing the violin. This can probably lead to serious disorders in long-term practice with repetitive movements. OBJECTIVE: For this reason, this study investigated the relationship between the right shoulder elevation and the force in the right glenohumeral joint during violin playing. It was hypothesized that the forces in the right glenohumeral joint are higher during playing with the right shoulder raised compared to playing in normal posture. METHODS: Motion capture data from four experienced violinists was recorded and processed by means of musculoskeletal simulation to get the force and elevation angle while playing with raised shoulder and in normal position. RESULTS: The results indicate that the absolute values of the resulting force, as well as the forces in the mediolateral, inferosuperior, and anteroposterior directions, are higher in playing the violin with the shoulder raised than in a normal posture. CONCLUSIONS: Elevating the right shoulder while playing the violin may pose a potential problem.}, subject = {Biomechanische Analyse}, language = {en} } @article{ZellnerHierlMuelleretal., author = {Zellner, Johannes and Hierl, Katja and Mueller, Michael and Pfeifer, Christian and Berner, Arne and Dienstknecht, Thomas and Krutsch, Werner and Geis, Sebastian and Gehmert, Sebastian and Kujat, Richard and Dendorfer, Sebastian and Prantl, Lukas and Nerlich, Michael and Angele, Peter}, title = {Stem cell-based tissue-engineering for treatment of meniscal tears in the avascular zone}, series = {Journal of Biomedical Materials Research Part B Applied Biomaterials}, volume = {101}, journal = {Journal of Biomedical Materials Research Part B Applied Biomaterials}, number = {7}, editor = {Gilbert, Jeremy}, doi = {10.1002/jbm.b.32922}, pages = {1133 -- 1142}, abstract = {Meniscal tears in the avascular zone have a poor self-healing potential, however partial meniscectomy predisposes the knee for early osteoarthritis. Tissue engineering with mesenchymal stem cells and a hyaluronan collagen based scaffold is a promising approach to repair meniscal tears in the avascular zone. 4 mm longitudinal meniscal tears in the avascular zone of lateral menisci of New Zealand White Rabbits were performed. The defect was left empty, sutured with a 5-0 suture or filled with a hyaluronan/collagen composite matrix without cells, with platelet rich plasma or with autologous mesenchymal stem cells. Matrices with stem cells were in part precultured in chondrogenic medium for 14 days prior to the implantation. Menisci were harvested at 6 and 12 weeks. The developed repair tissue was analyzed macroscopically, histologically and biomechanically. Untreated defects, defects treated with suture alone, with cell-free or with platelet rich plasma seeded implants showed a muted fibrous healing response. The implantation of stem cell-matrix constructs initiated fibrocartilage-like repair tissue, with better integration and biomechanical properties in the precultured stem cell-matrix group. A hyaluronan-collagen based composite scaffold seeded with mesenchymal stem cells is more effective in the repair avascular meniscal tear with stable meniscus-like tissue and to restore the native meniscus.}, subject = {Meniskusschaden}, language = {en} }