@article{SchimmerLadewigMotschetal., author = {Schimmer, Florian and Ladewig, Sven and Motsch, Nicole and Hausmann, Joachim M. and Ehrlich, Ingo}, title = {Comparison of Low-Velocity Impact Damage Behavior of Unidirectional Carbon Fiber-Reinforced Thermoset and Thermoplastic Composites}, series = {Key Engineering Materials}, volume = {809}, journal = {Key Engineering Materials}, publisher = {Trans Tech Publications}, issn = {1662-9795}, doi = {10.4028/www.scientific.net/KEM.809.9}, pages = {9 -- 14}, abstract = {This paper investigates the damage behavior of thermoset and thermoplastic fiber-reinforced composites. The specimens were subjected to low-velocity impacts (LVI) to produce barely visible impact damages (BVID). To compare the dependency of the matrix system and the laminate lay-up on the impact damage, four test series were set up. Therefore, laminates with an epoxy (EP) and a polyether ether ketone (PEEK) matrix in a quasi-isotropic (QI) [+45/0/-45/90]2s and an orthotropic (OT) fiber lay-up [0/90]4s were manufactured. To eliminate the influence of variant fiber systems, the thermoplastic tape and the thermoset prepreg contain similar carbon fibers (CF). After impact testing with three different impact energies, inner damages were investigated by using ultrasonic analyses. To get a deeper understanding of the interior damage mechanisms, cross sections of the damaged areas were examined via reflected light microscopy. By using these destructive and non-destructive test methods, significant differences in the damage behavior of composites with thermoplastic and thermoset matrix systems were identified for both laminate lay-ups.}, language = {en} } @article{WiesentSchultheissLullaetal., author = {Wiesent, Lisa and Schultheiß, Ulrich and Lulla, Philipp and Nonn, Aida and Noster, Ulf}, title = {Mechanical properties of small structures built by selective laser melting 316 L stainless steel - a phenomenological approach to improve component design}, series = {Materials Science \& Engineering Technology}, volume = {51}, journal = {Materials Science \& Engineering Technology}, number = {12}, publisher = {Wiley}, doi = {10.1002/mawe.202000038}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:898-opus4-14718}, pages = {1615 -- 1629}, abstract = {Experimental investigations are conducted to quantify the influence of specimen thickness and orientation on the mechanical properties of selective laser melted stainless steel 316 L. The results indicate that the mechanical strength and ductility increase with increasing specimen thickness until a saturation value is reached from a specimen thickness of about 2 mm. Specimen orientation dependency is pronounced for thin specimens (<1.5 mm), whereas only small deviations in strength are observed for thicker specimens with orientations of 30°, 45° and 90° to build direction. The mechanical properties of the specimen orientation of 0° to build direction shows great deviation to the other orientations and the smallest overall strength. A reliable design of selective laser melted components should account for specimen thickness and orientation, e. g. by a correction factor. Furthermore, it is recommended to avoid loads vertical (90°) and parallel (0°) to build direction to guarantee higher ductility and strength.}, language = {en} } @inproceedings{AltenbuchnerHaugWeber, author = {Altenbuchner, Amelie and Haug, Sonja and Weber, Karsten}, title = {Exploratory Analysis of Motion Tracking Data in the Rehabilitation Process of Geriatric Trauma Patients}, series = {Studies in Health Technology and Informatic. Volume 260: dHealth 2019 - From eHealth to dHealth}, booktitle = {Studies in Health Technology and Informatic. Volume 260: dHealth 2019 - From eHealth to dHealth}, editor = {Hayn, Dieter and Eggerth, A. and Schreier, G{\"u}nter}, publisher = {IOS Press}, doi = {10.3233/978-1-61499-971-3-138}, pages = {138 -- 145}, abstract = {Background: This article is based on an ongoing long-term study, in which customary motion trackers measure steps during rehabilitation of geriatric trauma patients (Med=86 years). Objectives: Exploring steps after 28 days of measurement. Finding similarities in the data by running cluster analysis and formulating linear regressions models to predict steps through time. Methods: Two types of motion trackers (FitBitAlta HR and Garmin v{\´i}vofit 3) have been used to measure patients' (N=24) steps after hip fracture in two study groups. Cluster analysis detected three clusters for progress in number of steps that were tested for group differences with ANOVA. Regression analysis tested models for individual patients. Results: Three-cluster solutions showed significant differences for the average amount of steps after 5, 14, 21 and 28 days. Regression models could predict 71 \% of the individual patients' progress in study group 2. Conclusion: The long-term study will provide more data in the future to examine the three-cluster solution and to find out in what stage of rehabilitation the measurement of the steps could be used to predict individual rehabilitation.}, language = {en} } @article{KofianiNonnWierzbicki, author = {Kofiani, Kirki and Nonn, Aida and Wierzbicki, Tomasz}, title = {New calibration method for high and low triaxiality and validation on SENT specimens of API X70}, series = {International Journal of Pressure Vessels and Piping}, volume = {111-112}, journal = {International Journal of Pressure Vessels and Piping}, doi = {10.1016/j.ijpvp.2013.07.004}, pages = {187 -- 201}, abstract = {The determination of the exact mechanical properties of material is essential for an optimal and safe design of linepipes. It is especially important for the prevention of over-engineering and the reliable assessment of complex accidental loading, such as extreme bending due to loss of buoyancy of support, or abrupt ground movement. Currently, the focus of research in offshore deepwater installations and linepipes is towards pre-cracked structures with high triaxiality stress states and complex loading histories. At the same time, low triaxiality stress states must be correctly studied in order to represent shear dominated failure in pipes. A comprehensive experimental and numerical program was undertaken to determine the mechanical properties of the traditional API X70 grade of steel. The material was characterized for anisotropic plasticity, fracture initiation and uncracked ductility for various states of stress. The same material was also used for pre-cracked fracture toughness assessment. The experimental program included flat and round specimens. The first type of tests on flat butterfly-shaped, central hole, notched and circular disk specimens; were selected to address the low stress triaxiality range. Tests on round notched bar specimens and SENT fracture mechanics tests extended the characterization and verification process to higher stress triaxiality values. This program covered a wide range of stress conditions and demonstrated their effect on the material resistance to crack extension. Each test conducted was numerically simulated using solid finite element models, matching the exact geometric and loading history features. The numerical simulation provided information on the local stress and strain fields around the location of the potential or existing cracks. Based on the above hybrid experimental/numerical technique tailored for pipe applications, the MMC fracture model was calibrated. The model relates the material ductility not only to stress triaxiality but also to the Lode parameter. The predictive capabilities of the MMC were then evaluated in the case of SENT testing, used extensively in the pipeline industry. It was shown that the present fracture model calibration can describe fracture behavior of SENT experiments.}, language = {en} } @article{CerroneWawrzynekNonnetal., author = {Cerrone, Albert R. and Wawrzynek, Paul and Nonn, Aida and Paulino, Glaucio H. and Ingraffea, Anthony R.}, title = {Implementation and verification of the Park-Paulino-Roesler cohesive zone model in 3D}, series = {Engineering Fracture Mechanics}, volume = {120}, journal = {Engineering Fracture Mechanics}, doi = {10.1016/j.engfracmech.2014.03.010}, pages = {26 -- 42}, abstract = {The Park-Paulino-Roesler (PPR) potential-based model is a cohesive constitutive model formulated to be consistent under a high degree of mode-mixity. Herein, the PPR's generalization to three-dimensions is detailed, its implementation in a finite element framework is discussed, and its use in single-core and high performance computing (HPC) applications is demonstrated. The PPR model is shown to be an effective constitutive model to account for crack nucleation and propagation in a variety of applications including adhesives, composites, linepipe steel, and microstructures.}, language = {en} } @article{CerroneNonnHochhalteretal., author = {Cerrone, Albert R. and Nonn, Aida and Hochhalter, Jacob D. and Bomarito, Geoffrey F. and Warner, J. E. and Carter, Bruce J.}, title = {Predicting failure of the Second Sandia Fracture Challenge geometry with a real-world, time constrained, over-the-counter methodology}, series = {International Journal of Fracture}, volume = {198}, journal = {International Journal of Fracture}, number = {1-2}, doi = {10.1007/s10704-016-0086-x}, pages = {117 -- 126}, abstract = {An over-the-counter methodology to predict fracture initiation and propagation in the challenge specimen of the Second Sandia Fracture Challenge is detailed herein. This pragmatic approach mimics that of an engineer subjected to real-world time constraints and unquantified uncertainty. First, during the blind prediction phase of the challenge, flow and failure locus curves were calibrated for Ti-6Al-4V with provided tensile and shear test data for slow (0.0254 mm/s) and fast (25.4 mm/s) loading rates. Thereafter, these models were applied to a 3D finite-element mesh of the non-standardized challenge geometry with nominal dimensions to predict, among other items, crack path and specimen response. After the blind predictions were submitted to Sandia National Labs, they were improved upon by addressing anisotropic yielding, damage initiation under shear dominance, and boundary condition selection.}, language = {en} } @article{NonnDahlBleck, author = {Nonn, Aida and Dahl, Winfried and Bleck, Wolfgang Peter}, title = {Numerical modelling of damage behaviour of laser-hybrid welds}, series = {Engineering Fracture Mechanics}, volume = {75}, journal = {Engineering Fracture Mechanics}, doi = {10.1016/j.engfracmech.2007.10.015}, pages = {3251 -- 3263}, abstract = {The effect of laser-hybrid welds on deformation and failure behaviour of fracture mechanics specimens is investigated in order to provide quantitative prediction of damage tolerance and residual strength. The simulation of crack initiation and crack extension in hybrid welds is performed by applying GTN damage model. The identification of damage parameters requires combined numerical and experimental analyses. The tendency to crack path deviation during crack growth depends strongly on the constraint development at the interface between base and weld metal. In order to quantify the influence of local stress state on the crack path deviation, the initial crack location is varied. Finally, the results from fracture mechanics tests are compared to real component, beam-column-connection, with respect to fracture resistance.}, language = {en} } @article{RueckBierlMatysik, author = {R{\"u}ck, Thomas and Bierl, Rudolf and Matysik, Frank-Michael}, title = {Development and characterization of a laboratory setup for photoacoustic NO2 determination based on the excitation of electronic 2B2 and 2B1 states using a low-cost semiconductor laser}, series = {Sensors and Actuators A: Physical}, volume = {258}, journal = {Sensors and Actuators A: Physical}, publisher = {Elsevier}, address = {Amsterdam, Niederlande}, doi = {10.1016/j.sna.2017.03.024}, pages = {193 -- 200}, abstract = {This work gives a detailed characterization of a laboratory setup for photoacoustic NO2 trace gas detection at the ppb level. The signal generation is based on the excitation of electronic 2B2 and 2B1 states using a low-cost semiconductor laser emitting at 450 nm. An acoustic resonator was used for signal amplification and the modulation frequency of the laser was determined to 3395 Hz in order to gain maximum signal amplification. The quality of resonant amplification was determined to 7.9. The gas samples were NO2 calibration gases diluted with pure nitrogen. The signal-to-noise ratio (SNR) dependency on the flow rate Q and the lock-in time constant τLIA was investigated, respectively, and the optimum values were specified to Q = 500 mL/min and τLIA = 2 s. In case of ambient noise, increasing τLIA to 10 s was evaluated as sufficient for SNR preservation. The noise level was measured in the absence of NO2 and it was determined to be composed of 51\% electronic noise and 49\% gas flow noise. With the analyte concentration ranging from 300 ppbV to 100 ppmV, the linear dependency of the photoacoustic amplitude on the NO2 concentration was specified, the sensitivity was determined to 110 μV/ppmV and the maximum measurement error was calculated to ±0.8\%. The detection limit was determined to 2.0 ppbV. Furthermore, the stability of the signal was investigated and a maximum drift of ±1\% was observed within a measuring period of 30 min. The response time τ90 was specified to 58 s. All results considered, this photoacoustic measuring system, which is based on low-cost signal generation and detection units, provides an excellent basis in view of developing a portable device for photoacoustic trace gas detection.}, language = {en} } @inproceedings{HauslerRothAumeretal., author = {Hausler, Peter and Roth, Carina and Aumer, F. and Vitzthumecker, Thomas and Genslein, Christa and Hirsch, Thomas and Bierl, Rudolf}, title = {Miniaturisiertes Sensorsystem zur Oberfl{\"a}chenplasmonenresonanzspektroskopie}, series = {118. Jahrestagung der deutschen Gesellschaft f{\"u}r angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden}, booktitle = {118. Jahrestagung der deutschen Gesellschaft f{\"u}r angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden}, abstract = {Die Oberfl{\"a}chenplasmonenresonanzspektroskopie (SPR) wird aufgrund ihrer Vorz{\"u}ge der zerst{\"o}rungs- und markierungsfreien Messung, sowie der hohen Sensitivit{\"a}t sehr erfolgreich im Labormaßstab eingesetzt. Aufgrund der hohen Kosten geschieht dies bislang haupts{\"a}chlich in der Bioanalytik und dem Wirkstoffscreening. Gezeigt wird ein Ansatz, mit dem diese Technologie auf ein ultrakompaktes, kosteng{\"u}nstiges Sensorsystem {\"u}bertragen wird, welches in der Lage ist, hoch-sensitiv {\"A}nderungen im Brechungsindex von 10-6 Einheiten (RIU) zu detektieren. F{\"u}r Wasser bewirkt eine Temperaturschwankung von 1 K bereits eine {\"A}nderung von 1 mRIU. Daher wird durch ein integriertes Referenzsystem, sowie die Miniaturisierung erreicht, dass das System gegen{\"u}ber Temperaturschwankungen, weitestgehend stabil ist. In dem MOEMS wird anstatt der konventionellen 1-Punkt bzw. 2-Punkt Messung ein bildgebendes Verfahren angewendet. Die Sensorfl{\"a}che von 15 x 15 mm wird dabei mit einem handels{\"u}blichen 4 Mio. Pixel CMOS Sensor ausgewertet. Um verl{\"a}ssliche Datenpunkte zu erhalten ben{\"o}tigt man eine Fl{\"a}che von 10 x 10 Pixel. Demzufolge k{\"o}nnen auf dem Sensor theoretisch bis zu 40.000 Sensorspots parallel ausgewertet werden.}, language = {de} } @inproceedings{RothHauslerBierl, author = {Roth, Carina and Hausler, Peter and Bierl, Rudolf}, title = {Einbindung eines 2D-Photodetektors in einen hochintegrierten SPR-Imaging-Sensor}, series = {118. Jahrestagung der deutschen Gesellschaft f{\"u}r angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden}, booktitle = {118. Jahrestagung der deutschen Gesellschaft f{\"u}r angewandte Optik (DGaO), 6.-10. Juni 2017, Dresden}, abstract = {Mit der Oberfl{\"a}chenplasmonenresonanzspektroskopie (SPR) k{\"o}nnen Brechungsindex{\"a}nderungen eines Analyten von bis zu 10-6 RIU detektiert werden. Das SPR-Imaging bietet heute gegen{\"u}ber der konventionellen SPR-Analyse die M{\"o}glichkeit, mehrere einzelne Messungen parallel durchf{\"u}hren zu k{\"o}nnen. Mit Hilfe eines zweidimensionalen Sensorchips und einer leistungsf{\"a}higen Boardlevelkamera k{\"o}nnen die Abbildungen des Chips direkt an einen Rechner {\"u}bertragen und dort verarbeitet werden. Aufgrund unterschiedlicher Winkelstellungen und der Geometrie des Aufbaus entstehen Stauchungen und Streckungen des abgebildeten Sensorchips, die mit verschiedenen Ans{\"a}tzen aus der Bildverarbeitung ausgeglichen werden, um die Bilder miteinander vergleichen zu k{\"o}nnen. Zudem wird die G{\"u}te der Referenz- und Messbereiche des Chips bestimmt. Diese Algorithmen sind nur m{\"o}glich aufgrund der heutigen, leistungsf{\"a}higen Rechner und der immer gr{\"o}ßer werdenden Durchsatzraten der Kameras. Dabei kommt in dieser Anwendung der relativ neue Kamerastandard USB3 Vision zum Einsatz. Dieser zeichnet sich zus{\"a}tzlich durch das Plug and Play und seinen Standardstecker, der an (fast) jedem Rechner vorhanden ist, aus.}, language = {de} }