Refine
Document Type
Has Fulltext
- no (5)
Reviewed
Keywords
Institute
Is part of the Bibliography
- yes (5)
To explore the ecological potential of large-scale geothermal collector systems (LSC) as a renewable heating and cooling solution for residential units in the U.S. West Coast finite volume simulations (FVM) were carried out. This study investigates for the first time in the LSC performance outside of Europe, demonstrating their significant potential for district heating and cooling solutions. However, it also reveals challenges in warmer climates where cooling requirements exceed heating demands. LSC systems here struggle due to increased soil temperatures, limiting their use for cooling, necessitating additional air conditioning. The FVM simulations also demonstrated that there is no supplementary soil dryness effect by using LSC systems. LSC systems paired with ground-source heat pumps (GS-HP) could reduce CO2 emissions by 72 % to 81 % compared to conventional Heating, Ventilation and Air Conditioning (HVAC) systems with economic benefits for residents. The efficiency comparison with air-source heat pumps (AS-HP) revealed a climate dependency of which solution is more efficient. This research outlines the ecological potential of LSC systems in diverse U.S. climates, marking a step forward in sector coupling and decarbonization strategies.
The fourth and fifth generation of district heating (GDH) networks are among the key elements for the energy optimization of districts. Low heat losses in the distribution lines as well as bidirectional heat flow and the use of low-temperature waste heat can lead to new business models for energy suppliers. Despite the continuous development of heat networks, significant heat losses still occur in conventional networks, despite well insulated pipelines, with fluid temperatures at 60-100 °C. Therefore, a study was conducted to investigate heat losses and gains in hot water heating (3GDH), low temperature heating (4GDH) and district heating and cooling networks (5GDHC) based on numerous simulations. The main purpose of the investigations is to determine the main factors influencing the heat transfer characteristics of underground heat networks. The derived results serve as a basis for the development of future planning tools to determine the heat losses and gains of local heating networks quickly and costefficiently.
Large-Scale Geothermal Collector Systems for 5th Generation District Heating and Cooling Networks
(2021)
Low temperature district heating and cooling networks (5GDHC) in combination with very shallow geothermal energy potentials enable the complete renewable heating and cooling supply of settlements up to entire city districts. With the help of 5GDHC, heating and cooling can be distributed at a low temperature level with almost no distribution losses and made useable to consumers via decentralized heat pumps (HP). Numerous renewable heat sources, from wastewater heat exchangers and low-temperature industrial waste heat to borehole heat exchangers and large-scale geothermal collector systems (LSC), can be used for these networks. The use of large-scale geothermal collector systems also offers the opportunity to shift heating and cooling loads seasonally, contributing to flexibility in the heating network. In addition, the soil can be cooled below freezing point due to the strong regeneration caused by the solar irradiation. Multilayer geothermal collector systems can be used to deliberately generate excessive cooling of individual areas in order to provide cooling energy for residential buildings, office complexes or industrial applications. Planning these systems requires expertise and understanding regarding the interaction of these technologies in the overall system. This paper provides a summary of experience in planning 5GDHC with large-scale geothermal collector systems as well as other renewable heat sources.
Im Forschungsvorhaben „+EQ-Net II“ wird der Betrieb eines gemischt genutzten Gebäudes über ein mehrjähriges Monitoring wissenschaftlich analysiert. Ziel ist es, Betriebsoptimierungspotenziale an der Anlagentechnik inklusive einer Großkollektoranlage zu heben. Aufgrund der Messdaten konnten bereits erhebliche Einsparpotenziale in der Wärmeverteilung aufgezeigt werden.
Ein oberflächennahestes Geothermiesystem wird aufgrund der ungedämmten Rohrleitungen und der Verlegung in 1 m bis 2 m Tiefe durch verschiedenste klimatische und hydrogeologische Rahmenbedingungen beeinflusst. Durch eine hygrothermische Simulationsanalyse konnten diese Einflussgrößen kategorisiert und bewertet werden. Dabei ist neben den klimatischen Rahmenbedingungen die Datengrundlage, wie die Einschätzung des Wasserhaltevermögens des Erdreichs und deren Wärmeleitfähigkeit sowie die Bodendichte, elementar. Dies führt zu teilweise signifikanten Änderungen des spezifischen Energieentzugs eines oberflächennahesten Geothermiesystems.Es wurde eine Parameterstudie zur Einschätzung der Einflussgrößen durchgeführt und die wichtigsten Einflussfaktoren ermittelt und bewertet. Die Ergebnisse der Einflussgrößen auf oberflächennaheste Geothermiesysteme führen zur verbesserten Einschätzung des Energieentzugs unter bestimmten klimatischen und bodenbedingten Randbedingungen.Die Simulationsergebnisse zeigen teils deutliche Unterschiede zu den bisher in der Fachwelt bekannten Werten der VDI 4640-2 und könnten als Basis für weitere Untersuchungen dienen.