Experimental noise reduction (aeroacoustical enhancement) of a large diameter axial flow cooling fan through a reduction in blade tip clearance

  • Aerodynamic and aeroacoustic performance experiments were carried out on four- and eight bladed, 1.542 m diameter, axial flow cooling fans, with constant solidity and hub-to-tip ratio. Tests were conducted in an ISO5801, Type A Fan Test facility. The tip gap (TG) was reduced from 4 mm (0.26% fan diameter) to 2 mm (0.13% fan diameter), to 0 mm, for both fan configurations. The noise profile of each fan configuration at the same TG over the whole volumetric flow rate spectrum was compared to each other. The 4 mm (0.26%) TG is used as a baseline to measure the nett increase or decrease in sound levels. Noise emissions decreased as the TG was reduced. It is discovered that the four bladed fan configuration had lower noise emissions than the eight bladed fan configuration at all blade tip clearances at design flow rate. It is concluded that reducing the TG and number of blades, at constant solidity, reduces sound emissions. The 0 mm TG for the four bladed fan produced the greatest reduction in noise emissions. An increase in fanAerodynamic and aeroacoustic performance experiments were carried out on four- and eight bladed, 1.542 m diameter, axial flow cooling fans, with constant solidity and hub-to-tip ratio. Tests were conducted in an ISO5801, Type A Fan Test facility. The tip gap (TG) was reduced from 4 mm (0.26% fan diameter) to 2 mm (0.13% fan diameter), to 0 mm, for both fan configurations. The noise profile of each fan configuration at the same TG over the whole volumetric flow rate spectrum was compared to each other. The 4 mm (0.26%) TG is used as a baseline to measure the nett increase or decrease in sound levels. Noise emissions decreased as the TG was reduced. It is discovered that the four bladed fan configuration had lower noise emissions than the eight bladed fan configuration at all blade tip clearances at design flow rate. It is concluded that reducing the TG and number of blades, at constant solidity, reduces sound emissions. The 0 mm TG for the four bladed fan produced the greatest reduction in noise emissions. An increase in fan total-to-static performance is observed when reducing the TG for both fan configurations.show moreshow less

Export metadata

Additional Services

Search Google Scholar
Metadaten
Author:Pieter Coenraad Swanepoel, Till M. BiedermannORCiD, Sybrand J van der Spuy
DOI:https://doi.org/10.1177/1475472X231183156
ISSN:1475-472X
Parent Title (English):International Journal of Aeroacoustics
Publisher:SAGE Publications
Document Type:Article
Language:English
Date of first Publication:2023/06/08
Reviewed:Begutachtet/Reviewed
Release Date:2024/08/12
Tag:Axial fan design; aeroacoustics; blade passing frequency; fan noise; tip clearance noise
Volume:22
Issue:3-4
Pagenumber:28
First Page:210
Last Page:237
institutes:Fakultät Maschinenbau und Versorgungstechnik
Research Themes:Energie & Ressourcen
Licence (German):Creative Commons - CC BY - Namensnennung 4.0 International