Introduction: Electrode misplacement and interchange errors are known problems when recording the 12‑lead electrocardiogram (ECG). Automatic detection of these errors could play an important role for improving clinical decision making and outcomes in cardiac care. The objectives of this systematic review and meta-analysis is to
1) study the impact of electrode misplacement on ECG signals and ECG interpretation,
2) to determine the most challenging electrode misplacements to detect using machine learning (ML),
3) to analyse the ML performance of algorithms that detect electrode misplacement or interchange according to sensitivity and specificity and
4) to identify the most commonly used ML technique for detecting electrode misplacement/interchange. This review analysed the current literature regarding electrode misplacement/interchange recognition accuracy using machine learning techniques.
Method: A search of three online databases including IEEE, PubMed and ScienceDirect identified 228 articles, while 3 articles were included from additional sources from co-authors. According to the eligibility criteria, 14 articles were selected. The selected articles were considered for qualitative analysis and meta-analysis.
Results: The articles showed the effect of lead interchange on ECG morphology and as a consequence on patient diagnoses. Statistical analysis of the included articles found that machine learning performance is high in detecting electrode misplacement/interchange except left arm/left leg interchange.
Conclusion: This review emphasises the importance of detecting electrode misplacement detection in ECG diagnosis and the effects on decision making. Machine learning shows promise in detecting lead misplacement/interchange and highlights an opportunity for developing and operationalising deep learning algorithms such as
convolutional neural network (CNN) to detect electrode misplacement/interchange.
Hypertension is a silent killer and one-third of its sufferers are unaware of its presence. Tonometric devices, like SphygmoCor, Compilor etc., represent the gold standard in pulse wave velocity (PWV) and augmentation index (AIx) measurements which are limited by their high cost and operational accuracy. Here, we present an alternative technology that is low cost and may be suitable for the ‘wearable’ setting. We undertook the comparisons of arterial waveforms obtained by photoplethysmogram (PPG) and finger ballistocardiogram (BPP) sensors which were then validated against a SphygmoCor tonometric device. Specifically, the agreement analysis of the augmentation, stiffness, reflection, elasticity, ejection elasticity and dicrotic reflection indexes showed that arterial distension waveform sensing using BPP sensor, has precision and accuracy similar to that of a SphygmoCor tonometric device whilst outperforming the volumetric arterial flow sensing using a PPG sensor, in every index. BPP indexes showed the r2 fit of up to 0.95 and Spearman’s rank correlation up to 0.91 when validated against the SphygmoCor tonometer. The estimated individual transfer functions for the BPP sensor, with reference to SphygmoCor, have accuracies of above 85% and 98% for 2 and 4-element windkessel (WK) models, respectively. The findings reported in this work may also be useful for the development of systems that are beneficial in the early and/or routine detection of hypertension.
Introduction: Interpretation of the 12‑lead Electrocardiogram (ECG) is normally assisted with an automated diagnosis (AD), which can facilitate an ‘automation bias’ where interpreters can be anchored. In this paper, we studied, 1) the effect of an incorrect AD on interpretation accuracy and interpreter confidence (a proxy foruncertainty), and 2) whether confidence and other interpreter features can predict interpretation accuracy using machine learning. Methods: This study analysed 9000 ECG interpretations from cardiology and non-cardiology fellows (CFs and non-CFs). One third of the ECGs involved no ADs, one third with ADs (half as incorrect) and one third had multiple ADs. Interpretations were scored and interpreter confidence was recorded for each interpretation and subsequently standardised using sigma scaling. Spearman coefficients were used for correlation analysis and C5.0 decision trees were used for predicting interpretation accuracy using basic interpreter features such as confidence, age, experience and designation. Results: Interpretation accuracies achieved by CFs and non-CFs dropped by 43.20% and 58.95% respectively when an incorrect AD was presented (p b 0.001). Overall correlation between scaled confidence and interpretation accuracy was higher amongst CFs. However, correlation between confidence and interpretation accuracy decreased for both groups when an incorrect AD was presented. We found that an incorrect AD disturbs the reliability of interpreter confidence in predicting accuracy. An incorrect AD has a greater effect on the confidence of nonCFs (although this is not statistically significant it is close to the threshold, p = 0.065). The best C5.0 decision tree achieved an accuracy rate of 64.67% (p b 0.001), however this is only 6.56% greater than the noinformation-rate. Conclusion: Incorrect ADs reduce the interpreter's diagnostic accuracy indicating an automation bias. Non-CFs tend to agree more with the ADs in comparison to CFs, hence less expert physicians are more effected by automation bias. Incorrect ADs reduce the interpreter's confidence and also reduces the predictive power of confidence for predicting accuracy (even more so for non-CFs). Whilst a statistically significant model was developed, it is difficult to predict interpretation accuracy using machine learning on basic features such as interpreter confidence, age, reader experience and designation.
Body surface potential maps (BSPMs) are typically recorded from a large number of ECG leads that cover the entire thorax. This improves diagnostic accuracy and is required in Electrocardiographic imaging (ECGi). BSPMs recorded in the clinical setting may have some leads that are noisy due to poor skin electrode contact. We analyzed 117 lead BSPMs recorded from 360 subjects. We successively simulated the removal of ECG leads at various locations and tested the ability of our algorithm to accurately reconstruct the missing information. When seven electrodes were removed, the algorithm could reconstruct BSPM patterns from QRS segments with median RMSE of 6.24µV and 12.15µV and CC of 0.999 and 0.997 when Laplacian method and PCA based method were used respectively. This work shows that noisy BSPM leads, which often manifest in the clinical setting, can be more accurately reconstructed using our Laplacian based interpolation
algorithm, when low number of missed electrodes in regions where electrodes are organised in a well distributed and tight mesh.
CPR Guideline Chest Compression Depths May Exceed Requirements for Optimal Physiological Response
(2018)
A twelve-animal porcine study dataset was retrospectively analyzed to assess associations between chest compression (CC) depth, systolic blood pressure (SBP) and end-tidal carbon dioxide (EtCO2). Manual CCs were applied for 7 two-minute episodes, at CC depths between 10mm-55mm. A rolling 15s analysis window was applied to the continuous signals. Mean peak values were calculated for each window. Correlation analysis was applied to assess strength of association. Optimal CC depth to achieve physiological targets was determined via cut-off analysis. A total of 672 observations for each variable were available for analysis. Pearson correlations (95% confidence interval; p-value) between CC depth and both SBP and ETCO2 were 0.84 (0.82, 0.86; p < 0.001) and 0.75 (0.71, 0.78; p < 0.001) respectively. Optimal CC depth cutoff (sensitivity, specificity) to achieve SBP ≥ 100mmHg and EtCO2 ≥ 10mmHg was 33 mm (98.29%, 88.94%) and 20mm (95.08%, 78.30%) respectively. A reasonable relationship between CC depth and
physiological response was observed. Optimal SBP and EtCO2 cut-offs were achieved significantly below guideline depths. Furthermore, cut-off analysis suggests a disparity between CC depth and physiological targets.
Heart rate variability analysis (HRVA) gives valuable insight to the cardiovascular system. Electrocardiogram (ECG) based HRVA has been assessment gold standard but eavesdropping of wearable technology requires the comparison of its surrogacy to an accepted standard. In this study, optical and mechanical measures at distal artery waveform are compared to the electrical signal of the heart. The sensor data of the six healthy volunteers are collated and compared at fiducial points in various time, frequency and non-linear domains for HRVA. We have found that during early systole fiducial location on waveforms can be surrogate to ECG standard and mechanical sensor 2nd derivative proved to be the best among them. Also, the comparative technology shows enormous potential for cardiovascular diagnostic.