Electrical energy storage systems are key to the integration of intermittent renewable energy technologies such as photovoltaic solar systems and wind turbines. As installed battery energy storage system capacities rise, it is crucial that the environmental impacts of these systems are also positive. In this work, a methodology to ascertain the effect and effectiveness of integration of energy storage on the carbon footprint of isolated island grid energy systems and its reduction is presented. Two metrics are introduced — the Levelized Emissions of Energy Supply (LEES), and the reduction in emissions per additional unit of energy storage (R). The proposed methodology is applied to an island grid scenario to ascertain the variation in the LEES value with the peak power and energy storage capacity of the BESS. A simplified LCA of a utility-scale Lithium-ion BESS is also carried out for this purpose. It is found that for the considered scenarios, incorporation of battery systems is always effective in reducing emissions, with a maximum possible reduction of nearly 50% compared to no storage. With the help of the metric R, the proposed methodology is also useful in identifying isolated energy systems which should be prioritized for incorporation of additional energy storage capacity.
Battery energy storage systems (BESS) coupled with rooftop-mounted residential photovoltaic (PV) generation, designated as PV-BESS, draw increasing attention and market penetration as more and more such systems become available. The manifold BESS deployed to date rely on a variety of different battery technologies, show a great variation of battery size, and power electronics dimensioning. However, given today’s high investment costs of BESS, a well-matched design and adequate sizing of the storage systems are prerequisites to allow profitability for the end-user. The economic viability of a PV-BESS depends also on the battery operation, storage technology, and aging of the system. In this paper, a general method for comprehensive PV-BESS techno-economic analysis and optimization is presented and applied to the state-of-art PV-BESS to determine its optimal parameters. Using a linear optimization method, a cost-optimal sizing of the battery and power electronics is derived based on solar energy availability and local demand. At the same time, the power flow optimization reveals the best storage operation patterns considering a trade-off between energy purchase, feed-in remuneration, and battery aging. Using up to date technology-specific aging information and the investment cost of battery and inverter systems, three mature battery chemistries are compared; a lead-acid (PbA) system and two lithium-ion systems, one with lithium-iron-phosphate (LFP) and another with lithium-nickel-manganese-cobalt (NMC) cathode. The results show that different storage technology and component sizing provide the best economic performances, depending on the scenario of load demand and PV generation.
This article proposes a basic concept for the multi-use of stationary battery storage systems with multiple stakeholders to improve the economic value of battery storage systems. An auction market is suggested, where segments of the energy storage system and rights of use are auctioned. The blockchain technology is incorporated to develop a generic, low-cost concept that enables distinct obligations between the stakeholders caused by the technical operation of the battery storage system. Smart contracts allow flexible sharing of the battery storage system and increase the system’s utilization ratio in the presence of prediction uncertainties.
Self-consumption of household photovoltaic (PV) storage systems has become profitable for residential owners under the trends of limited feed-in power and decreasing PV feed-in tariffs. For individual PV-storage systems, the challenge mainly lies in managing surplus generation of battery and grid power flow, ideally without relying on error-prone forecasts for both generation and consumption. Considering the large variation in power profiles of different houses in a neighborhood, the strategy is also supposed to be beneficial and applicable for the entire community. In this study, an adaptable battery charging control strategy is designed in order to obtain minimum costs for houses without any meteorological or load forecasts. Based on fuzzy logic control (FLC), battery state-of-charge (SOC) and the variation of SOC (∆SOC) are taken as input variables to dynamically determine output charging power with minimum costs. The proposed FLC-based algorithm benefits from the charging battery as much as possible during the daytime, and meanwhile properly preserves the capacity at midday when there is high possibility of curtailment loss. In addition, due to distinct power profiles in each individual house, input membership functions of FLC are improved by particle swarm optimization (PSO) to achieve better overall performance. A neighborhood with 74 houses in Germany is set up as a scenario for comparison to prior studies. Without forecasts of generation and consumption power, the proposed method leads to minimum costs in 98.6% of houses in the community, and attains the lowest average expenses for a single house each year.
This work discusses the grid-level suitability for stationary battery energy storage systems based on lithium ion technology in general, focusing on the integration of such systems in the low-voltage grid-level in Europe. The vast majority of recent research regarding stationary battery storage systems focuses on single-electricity-grid voltage levels, whereas the interaction of different electricity grid-levels has been widely neglected. Challenges in distribution grids mostly originate from the quantity of challenges in low-voltage grids, stationary battery energy storage systems that are operated in low-voltage grids may reduce these challenges. Therefore, this work investigates stationary battery energy storage systems installed in low-voltage grids and their effects on superimposed grid-levels. Simulation results show that grid challenges, addressed by battery storage systems in low-voltage grids, have positive multiplicative impacts on upper grid levels, reducing local grid demand and lowering power peak stress. A proposal is presented for a low-voltage grid battery storage system that can be operated to fulfill the aforementioned functionality and yield the benefits via a multi-purpose or multi-tasking battery storage system.