• search hit 7 of 26
Back to Result List

Coefficients for the Derivation of an ST Sensitive Patch Based Lead System from the 12 Lead Electrocardiogram

  • There are limited datasets available to facilitate the evaluation of patch-based lead systems, so the leads must be derived from existing data, mainly the 12-lead ECG. We have previously introduced a short spaced lead (SSL) system consisting of two leads with the largest ST segment changes during ischaemic-type episodes. In this study, we aim to evaluate the derivation of this patch-based lead system from the 12-lead ECG. Method: Thoracic body surface potential maps (BSPM) were recorded from n=734 patients. Using Laplacian interpolation, each recording was expanded to the 352-node Dalhousie torso. The eight independent channels of the 12-lead ECG were extracted (I, II, V1-V6) with the two leads of the SSL patch Coefficients were derived using linear regression from the 12-lead ECG to the SSL patch. Results: The median Pearson correlation coefficients (CC) and root mean square error (RMSE) for each lead were calculated as follows (CC/RMSE): 0.986/74.3 µV (ST monitoring lead); 0.976/65.3 µV (spatially orthogonalThere are limited datasets available to facilitate the evaluation of patch-based lead systems, so the leads must be derived from existing data, mainly the 12-lead ECG. We have previously introduced a short spaced lead (SSL) system consisting of two leads with the largest ST segment changes during ischaemic-type episodes. In this study, we aim to evaluate the derivation of this patch-based lead system from the 12-lead ECG. Method: Thoracic body surface potential maps (BSPM) were recorded from n=734 patients. Using Laplacian interpolation, each recording was expanded to the 352-node Dalhousie torso. The eight independent channels of the 12-lead ECG were extracted (I, II, V1-V6) with the two leads of the SSL patch Coefficients were derived using linear regression from the 12-lead ECG to the SSL patch. Results: The median Pearson correlation coefficients (CC) and root mean square error (RMSE) for each lead were calculated as follows (CC/RMSE): 0.986/74.3 µV (ST monitoring lead); 0.976/65.3 µV (spatially orthogonal lead). Conclusion: We have developed coefficients that allow the derivation of a patch-based lead system from the 12-lead ECG. Given the high correlation, it is possible to generate short spaced lead systems from existing diagnostic lead systems, however, amplitude errors are introduced in the process.show moreshow less

Export metadata

Additional Services

Search Google Scholar
Metadaten
Author:Daniel GüldenringORCiD, Michael R. Jennings, Ali S Rababah, James D. McLaughlinORCiD, Dewar D. FinlayORCiD
DOI:https://doi.org/10.23919/CinC53138.2021.9662649
Identifier:978-1-6654-7916-5 OPAC HS OPAC extern
Identifier:2325-887X OPAC HS OPAC extern
Parent Title (English):2021 Computing in Cardiology (CinC)
Publisher:IEEE
Place of publication:New York
Document Type:conference proceeding (article)
Conference:Computing in Cardiology, 48, 2021, Brno, Czech Republic
Language:English
Year of first Publication:2022
Tag:Computergestützte Elektrokardiographie
GND Keyword:Elektrokardiogramm, Biomedizinische Signalverarbeitung, ECG, EKG
Volume:48
Number of pages:4 Seiten
First Page:1
Last Page:4
Institutes:Fakultät Elektrotechnik
Dewey Decimal Classification:0 Informatik, Informationswissenschaft, allgemeine Werke
6 Technik, Medizin, angewandte Wissenschaften
Research focus:Eigenständige Forschungsfelder
Publication Lists:Güldenring, Daniel
Publication reviewed:begutachtet
Release Date:2022/03/14
Verstanden ✔