open_access
Refine
Year of publication
Document Type
- Announcement (99)
- Article (80)
- Conference Proceeding (18)
- Workingpaper / Report (16)
- Article trade magazine (5)
- Part of a Book (3)
- Course Material (3)
- Diploma Thesis (3)
- Book (2)
- Master's Thesis (2)
Keywords
- Amtliche Mitteilungen (96)
- Prüfungsrecht (77)
- Prüfungsordnung (65)
- Bachelor (40)
- Master (40)
- MV (29)
- Änderung (28)
- Maschinenbau (26)
- DOAJ (22)
- Satzung (21)
Department/institution
- Fachbereich - Maschinenbau und Verfahrenstechnik (233) (remove)
Nachstehend wird der Wortlaut der Prüfungsordnung für den Masterstudiengang „Simulations- und Experimentaltechnik“ an der Hochschule Düsseldorf vom 17.06.2021 (Verkündungsblatt der Hoch-schule Düsseldorf, Amtliche Mitteilung Nr. 786) unter ihrer neuen Überschrift neu bekannt gemacht. Die Neubekanntmachung berücksichtigt die Erste Satzung zur Änderung der Prüfungsordnung für den Masterstudiengang „Simulations- und Experimentaltechnik“ an der Hochschule Düsseldorf vom 02.03.2022 (Verkündungsblatt der Hochschule Düsseldorf, Amtliche Mitteilung Nr. 829) sowie die Zweite Satzung zur Änderung der Prüfungsordnung für den Masterstudiengang „Simulations- und Ex-perimentaltechnik“ an der Hochschule Düsseldorf vom 14.02.2024 (Verkündungsblatt der Hochschule Düsseldorf, Amtliche Mitteilung Nr. 915).
Men afflicted with hypogonadism have reduced fat-free mass and in some cases a loss in muscle strength. We hypothesize that muscle elasticity of the lower extremities differs between patients with hypogonadism and healthy controls. The shear modulus of the soleus muscle was measured non-invasively using MR elastography (MRE) at 0%, 5%, 10%, 15%, and 20% of the subject’s maximum applied force. The results from this study showed statistical differences between the patients and controls, even though there were no statistical differences in applied force.
Men afflicted with chronic obstructive pulmonary disease (COPD) show signs of muscle dysfunction, such as increased muscle fatigue and acidosis during exercise. We hypothesize that muscle elasticity of the lower extremities differs between patients with COPD and age-related controls. The shear modulus of the soleus muscle was measured non-invasively using MR elastography (MRE) at 0%, 5%, 10%, 15%, and 20% of the subject’s maximum applied force. The results from this study showed statistical differences between the patients and controls, even though there were no statistical differences in the maximum applied force.
Eye tracking is a measurement technique for determining the orientation and viewing direction of an individual’s eyes. It allows for an evaluation of the individual’s gaze and other related information.There is a wide variety of application areas for eye tracking, however the usage in engineeringindustry is still limited. This paper presents a case study for the use of eye tracking in a testingstation for electrical circuit breakers. The case study aims to evaluate the measurement and analysispossible with the Tobii wearable eye tracking system. From the case study, possibilities, limitationsand considerations for eye tracking in industrial settings are identified and discussed. The paperconcludes that while eye tracking can be used to effectively capture and visualize insightfulinformation, it faces major challenges related to subjectivity in analysis and labour intensiveness.
A numerical study is carried out meticulously to scrutinize the impact of different shapes of chimneys like circular (outer dia, dc), convergent (outer dia, 0.5dc), divergent (outer dia, 1.5dc), sudden contraction (outer dia, 0.5dc), and sudden expansion (outer dia, 1.5dc) on the performance of an SCPP. Furthermore, the parametric impact with different chimney divergence angles (CDA, ϕ), and ground absorber slope angle (GSA, γ) on the SCPP performance is also scrutinized. Optimum divergence angle (ϕ=+0.75◦) enhances the power generation up to ~ 47% (76 kW) with a horizontal ground absorber surface. An increase or decrease in CDA lessens the power generation. With a sloped ground absorber angle γ=0.6◦, the gain in power generation is 60% (82 kW). The study of combination of ground sloped absorber (γ=0.6◦) and divergent chimney (ϕ=+0.75◦) shows enhancement of the power generation upto 80% (92 kW) more than the classical Manzaranes plant.