Refine
Year of publication
Document Type
- Conference Proceeding (112)
- Article (19)
- Part of a Book (15)
- Article trade magazine (2)
- Diploma Thesis (1)
- Doctoral Thesis (1)
- Periodical (1)
Language
- English (136)
- German (12)
- Multiple languages (3)
Has Fulltext
- no (151) (remove)
Keywords
- VSVR (46)
- Virtual (TV) Studio (21)
- FHD (17)
- Sound Spatialization (8)
- Resource Management (6)
- Poster (5)
- audio rendering (5)
- human perception (5)
- virtual studio (5)
- Mixed Reality (4)
Department/institution
- Creative Media Production and Entertainment Computing (151) (remove)
CAD/CAM techniques are increasingly used in dentistry for the design and fabrication of teeth restorations. Important concerns are the correction of articulation problems that existed beforetreatment and the prevention of treatment-generated problems. These require interactive evaluation of the occlusal surfaces of teeth during mastication. Traditional techniques based on the use of casts with mechanical articulators require manual adjustment of occlusal surfaces, which becomes impractical when hard restoration materials like porcelain are used; they are also time and labor consuming and provide little visual information. We present new visual tools and a related user interface for global articulation simulation, developed for the Intelligent Dental Care System project. The aim of the simulation is visual representation of characteristics relevant to the chewing process. The simulation is based on the construction of distance maps, which are visual representations of the distributions of the distances of points in a tooth to the opposite jaw. We use rasterizing graphics hardware for fast calculation of the distance maps. Distance maps are used for collision detection and for the derivation of various characteristics showing the distribution of load on the teeth and the chewing capability of the teeth. Such characteristics can be calculated for particular positions of the jaws; cumulative characteristics are used to describe the properties of jaw movement. This information may be used for interactive design of the occlusal surfaces of restorations and for jaw articulation diagnosis. We also demonstrate elements of a user interface that exploit metaphors familiar to dentists from everyday practice.
Dynamic characteristics of occlusion during lower jaw motion are useful in the diagnosis of jaw articulation problems and in computer-aided design/manufacture of teeth restorations. The Functionally Generated Path (FGP), produced as a surface which envelops the actual occlusal surface of the moving opponent jaw, can be used for compact representation of dynamic occlusal relations. In traditional dentistry FGP is recorded as a bite impression in a patient’s mouth. We propose an efficient computerized technique for FGP reconstruction and validate it through implementation and testing. The distance maps between occlusal surfaces of jaws, calculated for multiple projection directions and accumulated for mandibular motion, provide information for FGP computation. Rasterizing graphics hardware is used for fast calculation of the distance maps. Real-world data are used: the scanned shape of teeth and the measured motion of the lower jaw. We show applications of FGP to analysis of the occlusion relations and occlusal surface design for restorations.
A filtering model for efficient rendering of the spatial image of an occluded virtual sound source
(1999)
Rendering realistic spatial sound imagery for complex virtual environments must take into account the effects of obstructions such as reflectors and occluders. It is relatively well understood how to calculate the acoustical consequence that would be observed at a given observation point when an acoustically opaque object occludes a sound source. But the interference patterns generated by occluders of various geometries and orientations relative to the virtual source and receiver are computationally intense if accurate results are required. In many applications, however, it is sufficient to create a spatial image that is recognizable by the human listener as the sound of an occluded source. In the interest of improving audio rendering efficiency, a simplified filtering model was developed and its audio output submitted to psychophysical evaluation. Two perceptually salient components of occluder acoustics were identified that could be directly related to the geometry and orientation of a simple occluder. Actual occluder impulse responses measured in an anechoic chamber resembled the responses of a model incorporating only a variable duration delay line and a low-pass filter with variable cutoff frequenc
Given limited computational resources available for the rendering of spatial sound imagery, we seek to determine effective means for choosing whatcomponents of the rendering will provide the most audible differences in the results. Rather than begin with an analytic approach that attempts to predict audible differences on the basis of objective parameters, we chose to begin with subjective tests of how audibly different the rendering result may be heard to be when that result includes two types of sound obstruction: reflectors and occluders. Single-channel recordings of 90 short speech sounds were made in an anechoic chamber in the presence and absence of these two types of obstructions, and as the angle of those obstructions varied over a 90 degree range. These recordings were reproduced over a single loudspeaker in that anechoic chamber, and listeners were asked to rate how confident they were that the recording of each of these 90 stimuli included an obstruction. These confidence ratings can be used as an integral component in the evaluation function used to determine which reflectors and occluders are most important for rendering.
In this paper we introduce a system for tracking persons walking or standing on a large planar surface and for using the acquired data to easily configure position based interactions for virtual studio productions. The tracking component of the system, radarTRACK, is based on a laser scanner device capable of delivering interaction points on a large configurable plane. By using the device on the floor it is possible to use the delivered data to detect feet positions and derive the position and orientation of one or more users in real time. The second component of the system, named OscCalibrator, allows for the easy creation of multidimensional linear mappings between input and output parameters and the routing of OSC messages within a single modular design environment. We demonstrate the use of our system to flexibly create position-based interactions in a virtual studio environment.