Refine
Year of publication
Document Type
- Article (228)
- Announcement (104)
- Conference Proceeding (99)
- Part of a Book (43)
- Workingpaper / Report (25)
- Article trade magazine (21)
- Doctoral Thesis (4)
- Book (3)
- Collection (3)
- Course Material (3)
Keywords
- Amtliche Mitteilungen (101)
- Prüfungsrecht (77)
- Prüfungsordnung (66)
- Bachelor (41)
- Master (41)
- MV (31)
- Maschinenbau (30)
- Änderung (29)
- DOAJ (22)
- Satzung (21)
Department/institution
- Fachbereich - Maschinenbau und Verfahrenstechnik (543) (remove)
Rotary mowers are ofen used for forage harvesting in agriculture, as this technology can achieve a high throughput. These knives are therefore exposed to high levels of wear and tear, and will also be ofen changed because of loss of material by bad cutting quality. That
is why it is interesting to save costs during manufacturing in spite of a correspondingly long service life. This research records the current manufacturing quality of the mower blades and examines how they behave in comparison. Based on the obtained results, further decisions on the methods, procedures and ways of extending the life of the disc mower blades should be proposed. For the investigations, a test bench based on a wear pot was used. The wear that occurs on the blade is determined using several parameters and compared accordingly. The parameters of the test setup determined as a result of the test can be used for further studies of wear resistance.
Artificial intelligence and design of experiments for resource adequacy assessment in power systems
(2024)
Nachstehend wird der Wortlaut der Prüfungsordnung für den Masterstudiengang „Simulations- und Experimentaltechnik“ an der Hochschule Düsseldorf vom 17.06.2021 (Verkündungsblatt der Hoch-schule Düsseldorf, Amtliche Mitteilung Nr. 786) unter ihrer neuen Überschrift neu bekannt gemacht. Die Neubekanntmachung berücksichtigt die Erste Satzung zur Änderung der Prüfungsordnung für den Masterstudiengang „Simulations- und Experimentaltechnik“ an der Hochschule Düsseldorf vom 02.03.2022 (Verkündungsblatt der Hochschule Düsseldorf, Amtliche Mitteilung Nr. 829) sowie die Zweite Satzung zur Änderung der Prüfungsordnung für den Masterstudiengang „Simulations- und Ex-perimentaltechnik“ an der Hochschule Düsseldorf vom 14.02.2024 (Verkündungsblatt der Hochschule Düsseldorf, Amtliche Mitteilung Nr. 915).
A two-component system for control and monitoring of solar power towers with molten salt receivers is proposed. The control component consists of a model predictive control applica-tion (MPC) with a flexible objective function and on-line tunable weights, which runs on a In-dustrial PC and uses a reduced order dynamic model of the receiver’s thermal and flow dy-namics. The second component consists of a service-life monitoring unit, which estimates the service-life consumption of the absorber tubes depending on the current mode of operation based on thermal stresses and creep fatigue in the high temperature regime. The calculation of stresses is done based on a detailed finite element study, in which a digital twin of the re-ceiver was developed. By parallelising the model solver, the estimation of service-life con-sumption became capable of real-time operation. The system has been implemented at a test facility in Jülich, Germany, and awaits field experiments. In this paper, the modeling and archi-tecture are presented along simulation results, which were validated on a hardware-in-the-loop test bench. The MPC showed good disturbance rejection while respecting process variable constraints during the simulation studies.
Magnetic Resonance (MR) elastography is a method for measuring tissue elasticity via phase images acquired with an MR scanner. The propagation of periodic mechanical waves through the tissue can be captured by means of a modified phase contrast sequence. These waves are generated with a mechanical oscillator (actuator) and coupled into the tissue through the skin. The actuator must be capable of generating a sinusoidal excitation with excellent phase and amplitude stability, while not disturbing the MR imaging process. In this work, an actuator based on a piezoelectric principle was developed. Based on the imaging evaluation of several material samples, the housing for the piezoelectric ceramic was constructed of aluminum. Smaller parts of the housing were manufactured from brass and titanium to fulfill the mechanical constraints. A lever was used to transfer the oscillation generated by the piezoelectric ceramic to the point of excitation. The lever amplifies the piezoelectric motion, allowing for a more compact design. Three different lever designs were characterized by an acceleration sensor both outside and inside the magnet. It was shown that the rigidity of the lever, as determined by its material and form, was decisive in determining the resonant frequency of the system and therefore the maximum practical frequency of operation. It was also shown that the motion of the oscillator is unaffected by the electromagnetic fields of the MR imager. The final design can be placed directly in the magnet bore within a few centimeters of the tissue volume to be imaged without generating significant artifacts. An amplitude range of 0–1 mm in the frequency range from 0 to over 300 Hz was achieved, sufficient for performing most MR elastography applications. © 2002 Wiley Periodicals, Inc. Concepts in Magnetic Resonance (Magn Reson Engineering) 15: 239–254, 2002