TY - JOUR A1 - Mandal, Dipak Kumar A1 - Bose, Sharmistha A1 - Biswas, Nirmalendu A1 - Manna, Nirmal K. A1 - Cuce, Erdem A1 - Benim, Ali Cemal T1 - Solar Chimney Power Plants for Sustainable Air Quality Management Integrating Photocatalysis and Particulate Filtration: A Comprehensive Review JF - Sustainability N2 - Urban air pollution has become a pressing challenge in recent times, demanding innovative solutions. This review delves into the potential of Solar Chimney Power Plants (SCPPs) as a sustainable approach to mitigating air pollution. The idea of mitigation of pollution may be an added advantage to the use of SCPPs in practice. Recent advancements, such as the integration of photocatalytic reactors (PCRs) for the elimination of greenhouse gases (GHGs), emphasizing the importance of addressing non-CO2 GHGs like CH4 and N2O are analyzed. The novelty of this review is that it not only focuses on the shifting and removal of particulate matter but also on the removal of greenhouse gases. Numerous case studies, ranging from filter-equipped SCPPs to Solar-Assisted Large-Scale Cleaning Systems (SALSCSs), are reviewed, providing a comprehensive understanding of their design, performance, and potential benefits. This review serves as a guide for researchers and policymakers, emphasizing the need for multifaceted approaches to address the intricate nexus of air pollution, renewable energy generation, and climate change mitigation. KW - solar chimney KW - air pollution KW - greenhouse gases KW - particulate matter KW - photocatalysis KW - Luftverschmutzung KW - Photokatalyst KW - Treibhausgas KW - Feinstaub KW - Aufwindkraftwerk Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-45814 SN - 2071-1050 VL - 16 IS - 6 PB - MDPI ER - TY - JOUR A1 - Mandal, Dipak Kumar A1 - Biswas, Nirmalendu A1 - Manna, Nirmal K. A1 - Gayen, Dilip Kumar A1 - Benim, Ali Cemal T1 - An application of artificial neural network (ANN) for comparative performance assessment of solar chimney (SC) plant for green energy production JF - Scientific Reports N2 - This study aims to optimize the power generation of a conventional Manzanares solar chimney (SC) plant through strategic modifications to the collector inlet height, chimney diameter, and chimney divergence. Employing a finite volume-based solver for numerical analysis, we systematically scrutinize influential geometric parameters, including collector height (hi = 1.85 to 0.1 m), chimney inlet diameter (dch = 10.16 to 55.88 m), and chimney outlet diameter (do = 10.16 to 30.48 m). Our findings demonstrate that reducing the collector inlet height consistently leads to increased power output. The optimal collector inlet height of hi = 0.2 m results in a significant power increase from 51 to 117.42 kW (~ 2.3 times) without additional installation costs, accompanied by an efficiency of 0.25%. Conversely, enlarging the chimney diameter decreases the chimney base velocity and suction pressure. However, as turbine-driven power generation rises, the flow becomes stagnant beyond a chimney diameter of 45.72 m. At this point, power generation reaches 209 kW, nearly four times greater than the Manzanares plant, with an efficiency of 0.44%. Nevertheless, the cost of expanding the chimney diameter is substantial. Furthermore, the impact of chimney divergence is evident, with power generation, collector efficiency, overall efficiency, and collector inlet velocity all peaking at an outer chimney diameter of 15.24 m (corresponding to an area ratio of 2.25). At this configuration, power generation increases to 75.91 kW, approximately 1.5 times more than the initial design. Remarkably, at a low collector inlet height of 0.2 m, combining it with a chimney diameter of 4.5 times the chimney inlet diameter (4.5dch) results in an impressive power output of 635.02 kW, signifying a substantial 12.45-fold increase. To model the performance under these diverse conditions, an artificial neural network (ANN) is effectively utilized. Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-45190 SN - 2045-2322 N1 - Data availability declaration: The data that support the findings of this scientific publication are available from the corresponding author upon reasonable request. Funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - 532148125 and supported by the central publication fund of Hochschule Düsseldorf University of Applied Sciences VL - 14 IS - 1 PB - Springer Nature ER - TY - JOUR A1 - Mandal, Dipak Kumar A1 - Biswas, Nirmalendu A1 - Manna, Nirmal K A1 - Benim, Ali Cemal T1 - Impact of chimney divergence and sloped absorber on energy efficacy of a solar chimney power plant (SCPP) JF - Ain Shams Engineering Journal N2 - A numerical study is carried out meticulously to scrutinize the impact of different shapes of chimneys like circular (outer dia, dc), convergent (outer dia, 0.5dc), divergent (outer dia, 1.5dc), sudden contraction (outer dia, 0.5dc), and sudden expansion (outer dia, 1.5dc) on the performance of an SCPP. Furthermore, the parametric impact with different chimney divergence angles (CDA, ϕ), and ground absorber slope angle (GSA, γ) on the SCPP performance is also scrutinized. Optimum divergence angle (ϕ=+0.75◦) enhances the power generation up to ~ 47% (76 kW) with a horizontal ground absorber surface. An increase or decrease in CDA lessens the power generation. With a sloped ground absorber angle γ=0.6◦, the gain in power generation is 60% (82 kW). The study of combination of ground sloped absorber (γ=0.6◦) and divergent chimney (ϕ=+0.75◦) shows enhancement of the power generation upto 80% (92 kW) more than the classical Manzaranes plant. KW - Solar chimney power plant (SCPP) KW - Chimney divergence angle KW - Sloped absorber surface KW - Power generation KW - Efficiency KW - Regression analysis KW - DEAL KW - HSD Publikationsfonds Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-42410 SN - 2090-4495 N1 - Datenverfügbarkeitserklärung: Daten, die die Ergebnisse dieser wissenschaftlichen Publikation stützen, sind auf begründete Anfrage bei dem*der korrespondierenden Autor*in erhältlich. PB - Elsevier ER - TY - JOUR A1 - Benim, Ali Cemal T1 - Introducing the “Mathematical Modelling and Numerical Simulation of Combustion and Fire” Section of the Journal Fire JF - fire Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-40257 SN - 2571-6255 VL - 5 IS - 6 PB - MDPI ER - TY - JOUR A1 - Mabrouk, Riheb A1 - Naji, Hassane A1 - Benim, Ali Cemal A1 - Dhahri, Hacen T1 - A State of the Art Review on Sensible and Latent Heat Thermal Energy Storage Processes in Porous Media: Mesoscopic Simulation JF - Applied Sciences KW - DOAJ Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-40343 VL - 12 IS - 14 PB - MDPI ER - TY - JOUR A1 - Biswas, Nirmalendu A1 - Mandal, Dipak Kumar A1 - Manna, Nirmal K. A1 - Benim, Ali Cemal T1 - Magneto-hydrothermal triple-convection in a W-shaped porous cavity containing oxytactic bacteria JF - scientific reports N2 - Bioconvective heat and mass transport phenomena have recently been the subject of interest in diverse fields of applications pertaining to the motion of fluids and their thermophysical properties. The transport processes in a system involving triple convective phenomena, irregular geometry, and boundary conditions constitute a complex phenomenon. This work aims to explore the mixed thermo-bioconvection of magnetically susceptible fluid containing copper nanoparticles and oxytactic bacteria in a novel W-shaped porous cavity. The buoyant convention is generated due to the isothermal heating at the wavy bottom wall, whereas the mixed convection is induced due to the shearing motion of the top-cooled sliding wall. Furthermore, the bioconvection is induced due to the manifestation of oxytactic bacteria or organisms. The inclined sidewalls are insulated. The geometry is packed with water based Cu nanoparticle mixed porous structure, which is subjected to a magnetizing field acted horizontally. The complex transport equations are transformed into nondimensional forms, which are then computed using the finite volume-based developed code. The coupled triple-convective flow physics are explored for a wide range of involved controlling parameters, which could provide helpful insight to the system designer for its proper operation. The shape of geometry can be considered one of the important parameters to control the heat and mass transport phenomena. In general, the influence of amplitude (δ) is more compared to the waviness number (m) of the undulations. The magnitude of heat (Nu) and mass (Sh) transfer rate for the W-shaped cavity is high compared to conventional square and trapezoidal-shaped cavities. The output of the analysis could be very helpful for the designer for modeling devices operating on nanotechnology-based bioconvection, microbial fuel cells, and others. KW - DOAJ Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-40041 SN - 2045-2322 VL - 12 PB - Springer Nature ER - TY - JOUR A1 - Benim, Ali Cemal A1 - Canal, Cansu Deniz A1 - Boke, Yakup Erhan T1 - A Validation Study for RANS Based Modelling of Swirling Pulverized Fuel Flames JF - Energies N2 - A swirling pulverized coal flame is computationally investigated. A Eulerian–Lagrangian formulation is used to describe the two-phase flow. Turbulence is modelled within a RANS (Reynolds averaged numerical simulation) framework. Four turbulence viscosity- (TV) based models, namely the standard k-ε model, realizable k-ε model, renormalization group theory k-ε model, and the shear stress transport k-ω model are used. In addition, a Reynolds stress transport model (RSM) is employed. The models are assessed by comparing the predicted velocity fields with the measurements of other authors. In terms of overall average values, the agreement of the predictions to the measurements is observed to be within the range 20–40%. A better performance of the RSM compared to the TV models is observed, with a nearly twice as better overall agreement to the experiments, particularly for the swirl velocity. In the second part of the investigation, the resolution of the discrete particle phase in modelling the turbulent particle dispersion (TPD) and particle size distribution (SD) is investigated. Using the discrete random walk model for the TPD, it is shown that even five random walks are sufficient for an accuracy that is quite high, with a less than 1% mean deviation from the solution obtained by thirty random walks. The approximation of the measured SD is determined by a continuous Rosin–Rammler distribution function, and inaccuracies that can occur in its subsequent discretization are demonstrated and discussed. An investigation on the resolution of the SD by discrete particle size classes (SC) indicates that 12 SC are required for an accuracy with a less than 1% mean deviation from the solution with 18 SC. Although these numbers may not necessarily be claimed to be sufficiently universal, they may serve as guidance, at least for SD with similar characteristics KW - DOAJ Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-37365 SN - 1996-1073 VL - 14 IS - 21 PB - MDPI ER - TY - JOUR A1 - Pfeiffelmann, Björn A1 - Benim, Ali Cemal A1 - Joos, Franz T1 - Water-Cooled Thermoelectric Generators for Improved Net Output Power: A Review JF - Energies N2 - Thermoelectric generators (TEGs) have the ability to convert waste heat into electrical energy under unfavorable conditions and are becoming increasingly popular in academia, but have not yet achieved a broad commercial success, due to the still comparably low efficiency. To increase the efficiency and economic viability of TEGs, research is performed on the materials on one hand and on the system connection on the other. In the latter case, the net output power of the cooling system plays a key role. At first glance, passive cooling seems preferable to active cooling because it does not affect the net electrical output power. However, as shown in the present review, the active cooling is to be preferred for net output power. The situation is similar in air and water-cooling. Even though air-cooling is easier to set up, the water-cooling should be preferred to achieve higher net output power. It is shown that microchannel cooling has similar hydraulic performance to conventional cooling and inserts increase the net output power of TEG. As the review reveals that active water-cooling should be the method of choice to achieve high net output power, it also shows that a careful optimization is necessary to exploit the potential. KW - Energy Engineering and Power Technology KW - Renewable Energy, Sustainability and the Environment KW - Electrical and Electronic Engineering KW - Control and Optimization KW - DOAJ Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-37323 SN - 1996-1073 VL - 14 IS - 24 PB - MDPI ER - TY - JOUR A1 - Benim, Ali Cemal T1 - Numerical Calculation of Sink Velocities for Helminth Eggs in Water JF - Computation N2 - The settling velocities of helminth eggs of three types, namely Ascaris suum (ASC), Trichuris suis (TRI), and Oesophagostomum spp. (OES), in clean tap water are computationally determined by means of computational fluid dynamics, using the general-purpose CFD software ANSYS Fluent 18.0. The previous measurements of other authors are taken as the basis for the problem formulation and validation, whereby the latter is performed by comparing the predicted sink velocities with those measured in an Owen tube. To enable a computational treatment, the measured shapes of the eggs are parametrized by idealizing them in terms of elementary geometric forms. As the egg shapes show a variation within each class, “mean” shapes are considered. The sink velocities are obtained through the computationally obtained drag coefficients. The latter are defined by means of steady-state calculations. Predicted sink velocities are compared with the measured ones. It is observed that the calculated values show a better agreement with the measurements, for ASC and TRI, compared to the theoretical sink values delivered by the Stokes theory. However, the observed agreement is still found not to be very satisfactory, indicating the role of further parameters, such as the uncertainties in the characterization of egg shapes or flocculation effects even in clean tap water. KW - Applied Mathematics KW - Modeling and Simulation KW - General Computer Science KW - Theoretical Computer Science KW - DOAJ Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-37318 SN - 2079-3197 VL - 9 IS - 12 PB - MDPI ER - TY - JOUR A1 - Benim, Ali Cemal A1 - Frank, Thiemo A1 - Assmann, Alexander A1 - Lichtenberg, Artur A1 - Akhyari, Payam T1 - Computational investigation of hemodynamics in hardshell venous reservoirs: A comparative study JF - Artificial Organs N2 - Extracorporeal circulation using heart‐lung‐machines is associated with a profound activation of corpuscular and plasmatic components of circulating blood, which can also lead to deleterious events such as systemic inflammatory response and hemolysis. Individual components used to install the extracorporeal circulation have an impact on the level of activation, most predominantly membrane oxygenators and hardshell venous reservoirs as used in extracorporeal systems. The blood flows in two different hardshell reservoirs are computationally investigated. A special emphasis is placed on the prediction of an onset of transition and turbulence generation. Reynolds‐averaged numerical simulations (RANS) based on a transitional turbulence model, as well as large eddy simulations (LES) are applied to achieve an accurate prediction. In the LES analysis, the non‐Newtonian behavior of the blood is considered via the Carreau model. Blood damage potential is quantified applying the Modified Index of Hemolysis (MIH) based on the predicted flow fields. The results indicate that the flows in both reservoirs remain predominantly laminar. For one of the reservoirs, considerable turbulence generation is observed near the exit site, caused by the specific design for the connection with the drainage tube. This difference causes the MIH of this reservoir to be nearly twice as large as compared to the alternative design. However, a substantial improvement of these performance criteria can be expected by a local geometry modification. Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:due62-opus-29070 SN - 1525-1594 VL - 44 IS - 4 SP - 411 EP - 418 PB - Wiley ER -