In an ongoing project, low-investment measures for the optimization of district heating systems are analyzed. The optimization strategies are collected in a catalog, which is the core of a guideline. The application of this guideline is demonstrated using two concrete district heating networks as examples. In this study, the improvement of an analog controlled district heating substation by an electronic controller is investigated. High supply temperatures and heat losses are often a challenge in district heating networks. The district heating substations have a major influence on the network return temperatures. The comparison of the two substation setups with analog and electronic controllers is carried out by laboratory measurement. It can be shown that the return temperatures can be reduced by an average of 20 K in winter and transition, as well as 16 K in summer. The district heating network losses are calculated for one of both specific district heating networks. They are calculated from the ratio of network losses to generated energy. The generated energy is the sum of network losses and consumer demand. The thermal losses of the network can be reduced by 3%. The volume flow in the heating network can be reduced to a quarter. Therefore, the pumping energy requirement drops sharply since these changes cubically affect the volume flow
This study compares two district heating substation systems for implementation in rural district heating networks with non-retrofitted single- and two-family houses. The aim is to determine which system has the potential to provide lower return temperatures and/or lower power peak demand. A hardware-in-the-loop-test rig was utilized to measure the two district heating substations under real operation conditions. This experimental study demonstrates that load balancing of the district heating network is attainable with the district heating substation with storage. This is especially advantageous when there is a high demand for domestic hot water. Overall, both systems yield comparable return temperatures.
Integrating renewable energies into district heating systems has a large potential to reduce CO2-emissions in the heating sector. As district heating systems offer the possibility of incorporating renewable energies into the heat supply, new systems have to be built and the existing networks must be maintained. This study investigates ways to optimize existing district heating systems in order to ensure economic sustainability in the long-term. Previous case studies have elaborated on a variety of optimization measures. However, to date, these measures have neither been collected nor consistently assessed for a wider application range. Therefore, in the study presented here a system for assessing the ecological and economic benefits of optimization measures was developed and applied. The assessment method utilized showed that optimization of district heating consumer substations and adding of a central buffer storage tank has a high optimization potential in comparison to intermittent operation strategy, which has a significantly lower optimization potential. From this information and the transferability data, a district heating operator can determine which optimization measure should be prioritized, which is shown at the end of the paper on an example case.