TY - INPR A1 - Ganz, Jonathan A1 - Marzahl, Christian A1 - Ammeling, Jonas A1 - Richter, Barbara A1 - Puget, Chloé A1 - Denk, Daniela A1 - Demeter, Elena A. A1 - Tabaran, Flaviu A. A1 - Wasinger, Gabriel A1 - Lipnik, Karoline A1 - Tecilla, Marco A1 - Valentine, Matthew J. A1 - Dark, Michael A1 - Abele, Niklas A1 - Bolfa, Pompei A1 - Erber, Ramona A1 - Klopfleisch, Robert A1 - Merz, Sophie A1 - Donovan, Taryn A1 - Jabari, Samir A1 - Bertram, Christof A1 - Breininger, Katharina A1 - Aubreville, Marc T1 - On the Value of PHH3 for Mitotic Figure Detection on H&E-stained Images N2 - The count of mitotic figures (MFs) observed in hematoxylin and eosin (H&E)-stained slides is an important prognostic marker as it is a measure for tumor cell proliferation. However, the identification of MFs has a known low inter-rater agreement. Deep learning algorithms can standardize this task, but they require large amounts of annotated data for training and validation. Furthermore, label noise introduced during the annotation process may impede the algorithm's performance. Unlike H&E, the mitosis-specific antibody phospho-histone H3 (PHH3) specifically highlights MFs. Counting MFs on slides stained against PHH3 leads to higher agreement among raters and has therefore recently been used as a ground truth for the annotation of MFs in H&E. However, as PHH3 facilitates the recognition of cells indistinguishable from H&E stain alone, the use of this ground truth could potentially introduce noise into the H&E-related dataset, impacting model performance. This study analyzes the impact of PHH3-assisted MF annotation on inter-rater reliability and object level agreement through an extensive multi-rater experiment. We found that the annotators' object-level agreement increased when using PHH3-assisted labeling. Subsequently, MF detectors were evaluated on the resulting datasets to investigate the influence of PHH3-assisted labeling on the models' performance. Additionally, a novel dual-stain MF detector was developed to investigate the interpretation-shift of PHH3-assisted labels used in H&E, which clearly outperformed single-stain detectors. However, the PHH3-assisted labels did not have a positive effect on solely H&E-based models. The high performance of our dual-input detector reveals an information mismatch between the H&E and PHH3-stained images as the cause of this effect. UR - https://doi.org/10.48550/arXiv.2406.19899 Y1 - 2024 UR - https://doi.org/10.48550/arXiv.2406.19899 UR - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:573-50155 PB - arXiv CY - Ithaca ER - TY - INPR A1 - Ganz, Jonathan A1 - Marzahl, Christian A1 - Ammeling, Jonas A1 - Rosbach, Emely A1 - Richter, Barbara A1 - Puget, Chloé A1 - Denk, Daniela A1 - Demeter, Elena A. A1 - Tabaran, Flaviu A. A1 - Wasinger, Gabriel A1 - Lipnik, Karoline A1 - Tecilla, Marco A1 - Valentine, Matthew J. A1 - Dark, Michael A1 - Abele, Niklas A1 - Bolfa, Pompei A1 - Erber, Ramona A1 - Klopfleisch, Robert A1 - Merz, Sophie A1 - Donovan, Taryn A1 - Jabari, Samir A1 - Bertram, Christof A1 - Breininger, Katharina A1 - Aubreville, Marc T1 - Information Mismatch in PHH3-Assisted Mitosis Annotation Leads to Interpretation Shifts in H&E Slide Analysis T2 - Research Square N2 - The count of mitotic figures (MFs) observed in hematoxylin and eosin (H&E)-stained slides is an important prognostic marker, as it is a measure for tumor cell proliferation. However, the identification of MFs has a known low inter-rater agreement. In a computer-aided setting, deep learning algorithms can help to mitigate this, but they require large amounts of annotated data for training and validation. Furthermore, label noise introduced during the annotation process may impede the algorithms' performance. Unlike H&E, where identification of MFs is based mainly on morphological features, the mitosis-specific antibody phospho-histone H3 (PHH3) specifically highlights MFs. Counting MFs on slides stained against PHH3 leads to higher agreement among raters and has therefore recently been used as a ground truth for the annotation of MFs in H&E. However, as PHH3 facilitates the recognition of cells indistinguishable from H&E staining alone, the use of this ground truth could potentially introduce an interpretation shift and even label noise into the H&E-related dataset, impacting model performance. This study analyzes the impact of PHH3-assisted MF annotation on inter-rater reliability and object level agreement through an extensive multi-rater experiment. Subsequently, MF detectors, including a novel dual-stain detector, were evaluated on the resulting datasets to investigate the influence of PHH3-assisted labeling on the models' performance. We found that the annotators' object-level agreement significantly increased when using PHH3-assisted labeling (F1: 0.53 to 0.74). However, this enhancement in label consistency did not translate to improved performance for H&E-based detectors, neither during the training phase nor the evaluation phase. Conversely, the dual-stain detector was able to benefit from the higher consistency. This reveals an information mismatch between the H&E and PHH3-stained images as the cause of this effect, which renders PHH3-assisted annotations not well-aligned for use with H&E-based detectors. Based on our findings, we propose an improved PHH3-assisted labeling procedure. UR - https://doi.org/10.21203/rs.3.rs-4900505/v1 Y1 - 2024 UR - https://doi.org/10.21203/rs.3.rs-4900505/v1 UR - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:573-57630 SN - 2693-5015 PB - Research Square CY - Durham ER - TY - JOUR A1 - Ganz, Jonathan A1 - Marzahl, Christian A1 - Ammeling, Jonas A1 - Rosbach, Emely A1 - Richter, Barbara A1 - Puget, Chloé A1 - Denk, Daniela A1 - Demeter, Elena A. A1 - Tabaran, Flaviu A. A1 - Wasinger, Gabriel A1 - Lipnik, Karoline A1 - Tecilla, Marco A1 - Valentine, Matthew J. A1 - Dark, Michael A1 - Abele, Niklas A1 - Bolfa, Pompei A1 - Erber, Ramona A1 - Klopfleisch, Robert A1 - Merz, Sophie A1 - Donovan, Taryn A1 - Jabari, Samir A1 - Bertram, Christof A1 - Breininger, Katharina A1 - Aubreville, Marc T1 - Information mismatch in PHH3-assisted mitosis annotation leads to interpretation shifts in H&E slide analysis JF - Scientific Reports N2 - The count of mitotic figures (MFs) observed in hematoxylin and eosin (H&E)-stained slides is an important prognostic marker, as it is a measure for tumor cell proliferation. However, the identification of MFs has a known low inter-rater agreement. In a computer-aided setting, deep learning algorithms can help to mitigate this, but they require large amounts of annotated data for training and validation. Furthermore, label noise introduced during the annotation process may impede the algorithms’ performance. Unlike H&E, where identification of MFs is based mainly on morphological features, the mitosis-specific antibody phospho-histone H3 (PHH3) specifically highlights MFs. Counting MFs on slides stained against PHH3 leads to higher agreement among raters and has therefore recently been used as a ground truth for the annotation of MFs in H&E. However, as PHH3 facilitates the recognition of cells indistinguishable from H&E staining alone, the use of this ground truth could potentially introduce an interpretation shift and even label noise into the H&E-related dataset, impacting model performance. This study analyzes the impact of PHH3-assisted MF annotation on inter-rater reliability and object level agreement through an extensive multi-rater experiment. Subsequently, MF detectors, including a novel dual-stain detector, were evaluated on the resulting datasets to investigate the influence of PHH3-assisted labeling on the models’ performance. We found that the annotators’ object-level agreement significantly increased when using PHH3-assisted labeling (F1: 0.53 to 0.74). However, this enhancement in label consistency did not translate to improved performance for H&E-based detectors, neither during the training phase nor the evaluation phase. Conversely, the dual-stain detector was able to benefit from the higher consistency. This reveals an information mismatch between the H&E and PHH3-stained images as the cause of this effect, which renders PHH3-assisted annotations not well-aligned for use with H&E-based detectors. Based on our findings, we propose an improved PHH3-assisted labeling procedure. UR - https://doi.org/10.1038/s41598-024-77244-6 Y1 - 2024 UR - https://doi.org/10.1038/s41598-024-77244-6 UR - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:573-53559 SN - 2045-2322 VL - 14 IS - 1 PB - Springer Nature CY - London ER - TY - JOUR A1 - Haghofer, Andreas A1 - Parlak, Eda A1 - Bartel, Alexander A1 - Donovan, Taryn A1 - Assenmacher, Charles-Antoine A1 - Bolfa, Pompei A1 - Dark, Michael A1 - Fuchs-Baumgartinger, Andrea A1 - Klang, Andrea A1 - Jäger, Kathrin A1 - Klopfleisch, Robert A1 - Merz, Sophie A1 - Richter, Barbara A1 - Schulman, F. Yvonne A1 - Janout, Hannah A1 - Ganz, Jonathan A1 - Scharinger, Josef A1 - Aubreville, Marc A1 - Winkler, Stephan M. A1 - Kiupel, Matti A1 - Bertram, Christof T1 - Nuclear pleomorphism in canine cutaneous mast cell tumors: Comparison of reproducibility and prognostic relevance between estimates, manual morphometry, and algorithmic morphometry JF - Veterinary Pathology N2 - Variation in nuclear size and shape is an important criterion of malignancy for many tumor types; however, categorical estimates by pathologists have poor reproducibility. Measurements of nuclear characteristics can improve reproducibility, but current manual methods are time-consuming. The aim of this study was to explore the limitations of estimates and develop alternative morphometric solutions for canine cutaneous mast cell tumors (ccMCTs). We assessed the following nuclear evaluation methods for accuracy, reproducibility, and prognostic utility: (1) anisokaryosis estimates by 11 pathologists; (2) gold standard manual morphometry of at least 100 nuclei; (3) practicable manual morphometry with stratified sampling of 12 nuclei by 9 pathologists; and (4) automated morphometry using deep learning–based segmentation. The study included 96 ccMCTs with available outcome information. Inter-rater reproducibility of anisokaryosis estimates was low (k = 0.226), whereas it was good (intraclass correlation = 0.654) for practicable morphometry of the standard deviation (SD) of nuclear size. As compared with gold standard manual morphometry (area under the ROC curve [AUC] = 0.839, 95% confidence interval [CI] = 0.701–0.977), the prognostic value (tumor-specific survival) of SDs of nuclear area for practicable manual morphometry and automated morphometry were high with an AUC of 0.868 (95% CI = 0.737–0.991) and 0.943 (95% CI = 0.889–0.996), respectively. This study supports the use of manual morphometry with stratified sampling of 12 nuclei and algorithmic morphometry to overcome the poor reproducibility of estimates. Further studies are needed to validate our findings, determine inter-algorithmic reproducibility and algorithmic robustness, and explore tumor heterogeneity of nuclear features in entire tumor sections. UR - https://doi.org/10.1177/03009858241295399 Y1 - 2024 UR - https://doi.org/10.1177/03009858241295399 UR - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:573-53661 SN - 1544-2217 SN - 0300-9858 VL - 62 IS - 2 SP - 161 EP - 177 PB - Sage CY - London ER - TY - JOUR A1 - Glahn, Imaine A1 - Haghofer, Andreas A1 - Donovan, Taryn A1 - Degasperi, Brigitte A1 - Bartel, Alexander A1 - Kreilmeier-Berger, Theresa A1 - Hyndman, Philip S. A1 - Janout, Hannah A1 - Assenmacher, Charles-Antoine A1 - Bartenschlager, Florian A1 - Bolfa, Pompei A1 - Dark, Michael A1 - Klang, Andrea A1 - Klopfleisch, Robert A1 - Merz, Sophie A1 - Richter, Barbara A1 - Schulman, F. Yvonne A1 - Ganz, Jonathan A1 - Scharinger, Josef A1 - Aubreville, Marc A1 - Winkler, Stephan M. A1 - Bertram, Christof T1 - Automated Nuclear Morphometry: A Deep Learning Approach for Prognostication in Canine Pulmonary Carcinoma to Enhance Reproducibility JF - Veterinary Sciences N2 - The integration of deep learning-based tools into diagnostic workflows is increasingly prevalent due to their efficiency and reproducibility in various settings. We investigated the utility of automated nuclear morphometry for assessing nuclear pleomorphism (NP), a criterion of malignancy in the current grading system in canine pulmonary carcinoma (cPC), and its prognostic implications. We developed a deep learning-based algorithm for evaluating NP (variation in size, i.e., anisokaryosis and/or shape) using a segmentation model. Its performance was evaluated on 46 cPC cases with comprehensive follow-up data regarding its accuracy in nuclear segmentation and its prognostic ability. Its assessment of NP was compared to manual morphometry and established prognostic tests (pathologists’ NP estimates (n = 11), mitotic count, histological grading, and TNM-stage). The standard deviation (SD) of the nuclear area, indicative of anisokaryosis, exhibited good discriminatory ability for tumor-specific survival, with an area under the curve (AUC) of 0.80 and a hazard ratio (HR) of 3.38. The algorithm achieved values comparable to manual morphometry. In contrast, the pathologists’ estimates of anisokaryosis resulted in HR values ranging from 0.86 to 34.8, with slight inter-observer reproducibility (k = 0.204). Other conventional tests had no significant prognostic value in our study cohort. Fully automated morphometry promises a time-efficient and reproducible assessment of NP with a high prognostic value. Further refinement of the algorithm, particularly to address undersegmentation, and application to a larger study population are required. UR - https://doi.org/10.3390/vetsci11060278 Y1 - 2024 UR - https://doi.org/10.3390/vetsci11060278 UR - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:573-48612 SN - 2306-7381 VL - 11 IS - 6 PB - MDPI CY - Basel ER -