    <title language="eng">Towards Sustainable Community Development through Renewable Energies in Kyrgyzstan: A Detailed Assessment and Outlook</title>
    <abstract language="eng">In rural Kyrgyzstan, the energy need is usually derived from multiple natural energy resources such as firewood, charcoal, agricultural residues, animal dung, and wood branches, which are considered common and predominant practices. Because of the non-sustainable resources and heavy reliance on the environment, Kyrgyzstan is one of the most vulnerable countries to climate change in Central Asia. On the contrary, the great renewable energy potential in Kyrgyzstan is untapped, which could be the most promising solution to ensuring sustainable energy supply in the country. However, because of the lack of scientific knowledge, current energy policies, and the lack of infrastructure, renewable resources are mainly untapped. To exploit the country’s renewable energy potential, there is a need for a systematic diagnosis to develop a strategy to explore renewables in Kyrgyzstan, which is currently missing in the existing literature. In that regard, the presented study aims to assess the current status of renewable energy sources by considering the local energy context from a potential point of view. Further to this, it provides a comparative overview through a matrix of strengths, weaknesses, opportunities, and threats. Such novel analysis would be the fundamental base for formulating policy advice and a national plan to enhance the utilization of renewable energy in Kyrgyzstan. The presented analysis was carried out based on the extensive literature review, the country’s national plan, and the existing energy policies of Kyrgyzstan. The article found out that there is huge potential available for the renewable energy market. As compared to other renewable energy sources, solar energy has great potential and can be considered one of the pioneer sustainable sources for integration into the country’s power generation framework.</abstract>
    <parentTitle language="eng">World</parentTitle>
    <identifier type="issn">2673-4060</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-28086</identifier>
    <enrichment key="opus.import.date">2022-09-03T17:24:36+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">deepgreen</enrichment>
    <enrichment key="opus.import.file">attachment; filename=deposit.zip</enrichment>
    <enrichment key="opus.import.checksum">60d17307b8bbc35146f858c07c319e62</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.3390/world3020018</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Kedar</first_name>
      <last_name>Mehta</last_name>
    </author>
    <author>
      <first_name>Mathias</first_name>
      <last_name>Ehrenwirth</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Wilfried</first_name>
      <last_name>Zörner</last_name>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Central Asia</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>energy services</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>high-altitude</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Kyrgyzstan</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>renewable energy resources</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>sustainable energy</value>
    </subject>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="persons" number="26227">Zörner, Wilfried</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="Import" number="deepgreen">DeepGreen</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/2808/world-03-00018-v2.pdf</file>
  </doc>
  <doc>
    <id>2782</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>18</pageNumber>
    <edition/>
    <issue>17</issue>
    <volume>15</volume>
    <articleNumber>6281</articleNumber>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace>Basel</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>2022-08-29</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Sector Coupling Potential of a District Heating Network by Consideration of Residual Load and CO2 Emissions</title>
    <abstract language="eng">The growing share of fluctuating renewable electricity production within the German energy system causes the increasing necessity for flexible consumers, producers, and storage technologies to balance supply and demand. District heating networks with combined heat and power units, Power-to-Heat applications, and thermal energy storage capacities can serve as one of these flexible options. In this context, a simulation model of the district heating network of the rural community Dollnstein, Germany, was built. With the residual load of different regional areas (Germany, Bavaria, Eichstätt, Dollnstein) it is investigated, how the heat generators can operate in an electricity market beneficial way. Two different control algorithms were evaluated: Due to a correlation between the residual loads and the CO2 emissions of the electricity mix, the CO2 savings achieved by this control algorithm are determined. Another way to operate electricity market beneficial is to consider the current CO2 emissions of each region. The main outcomes of this paper are, that there is a high potential for sector coupling by shifting the operation times of a CHP and a heat pump according to the residual load. The electricity demand of the heat pump can be met in terms of low CO2 emissions of the electricity mix, while the CHP can replace electricity with high CO2 emissions. These results can be improved, by considering not the residual load but the current CO2 emissions in the control algorithm.</abstract>
    <parentTitle language="eng">Energies</parentTitle>
    <identifier type="issn">1996-1073</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-27820</identifier>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.3390/en15176281</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Melanie</first_name>
      <last_name>Werner</last_name>
    </author>
    <author>
      <first_name>Sebastian</first_name>
      <last_name>Muschik</last_name>
    </author>
    <author>
      <first_name>Mathias</first_name>
      <last_name>Ehrenwirth</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Tobias</first_name>
      <last_name>Schrag</last_name>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>district heating networks</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>sector coupling</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>residual load</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>CO2 emissions</value>
    </subject>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="persons" number="26717">Schrag, Tobias</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/2782/Werner_et_al_2022.pdf</file>
  </doc>
  <doc>
    <id>3344</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>14</pageNumber>
    <edition/>
    <issue>7</issue>
    <volume>16</volume>
    <articleNumber>3155</articleNumber>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace>Basel</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Assessment of Conservation Voltage Reduction in Distribution Networks with Voltage Regulating Distribution Transformers</title>
    <abstract language="eng">The application of voltage reduction in medium and low voltage grids to reduce peak power demand or energy consumption has been implemented since the 1980s using several approaches. Conservation Voltage Reduction (CVR), as one such approach, uses a voltage control device to reduce or increase the voltage setpoint on a busbar, thereby reducing or increasing the amount of active and reactive power supply in the network. Voltage regulation for CVR is always implemented according to established network planning standards in each country. Research in this field has proven that a CVR factor (CVRf) of 0.7–1.5 for peak demand reduction can be achieved. This is an evaluation metric of CVR. The aim of this research is to determine and validate CVRf for peak demand reduction by comparing actual results obtained during regular tap changes with other randomly distributed periods outside tap change operations, using a set of measurement data. It is important to understand CVR deployment capability by evaluating CVR potentials from historical random tap operations before a robust network-wide deployment is introduced. This research provides such guidance. It also provides a novel approach to determining tap changes from voltage measurements using a time-based algorithm. A CVRf ranging from 0.95 to 1.61 was estimated using a measurement dataset from a test field. The result of the entire evaluation shows that the CVRf are smaller during peak PV production and greater during peak demand periods. Further evaluation using statistical hypotheses testing and a control chart was used to validate the evaluation.</abstract>
    <parentTitle language="eng">Energies</parentTitle>
    <identifier type="issn">1996-1073</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-33449</identifier>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.3390/en16073155</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Anthony</first_name>
      <last_name>Igiligi</last_name>
    </author>
    <author>
      <first_name>Armin</first_name>
      <last_name>Vielhauer</last_name>
    </author>
    <author>
      <first_name>Mathias</first_name>
      <last_name>Ehrenwirth</last_name>
    </author>
    <author>
      <first_name>Christian</first_name>
      <last_name>Hurm</last_name>
    </author>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Daniel</first_name>
      <last_name>Navarro Gevers</last_name>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>conservation voltage reduction</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>peak power</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>tap change</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>voltage regulating distribution transformers</value>
    </subject>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="persons" number="26816">Navarro Gevers, Daniel</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/3344/energies-16-03155.pdf</file>
  </doc>
  <doc>
    <id>3787</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>10</pageNumber>
    <edition/>
    <issue>230, Part A</issue>
    <volume>2023</volume>
    <articleNumber>120657</articleNumber>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace>Amsterdam</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>2023-07-14</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Effect of argon concentration on thermal efficiency of gas-filled insulating glass flat-plate collectors</title>
    <abstract language="eng">Insulating glass flat-plate collectors can save cost by being produced quickly and automatically in insulated glass production facilities, and they can be filled with argon to reduce heat loss. During its lifetime, the collector is likely to lose argon because of gradual material degradation of the sealing. However, information on the influence of the argon concentration on the collector efficiency is limited. Therefore, the objective of this research work was to analyse this effect. A theoretical material property calculation of argon-air mixtures was carried out to determine the convective losses with variable argon concentrations. Thermal collector performance was measured experimentally using an outdoor solar tracker test rig. The results strongly suggest, that the influence of argon concentration on both the convective losses and the thermal efficiency is non-linear. The measurements revealed that an argon concentration of 90 % can increase average thermal performance by 6.7 ± 4.8 percentage points. An increase in argon concentration from 0 % to 50 % has almost twice the effect on average thermal efficiency as an increase from 50 % to 90 %. Concluding from these results, an argon leakage threshold of 2.5 percentage points per year is proposed to avoid disproportionate loss of efficiency over time.</abstract>
    <parentTitle language="eng">Applied Thermal Engineering</parentTitle>
    <identifier type="issn">1873-5606</identifier>
    <identifier type="issn">1359-4311</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-37875</identifier>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.1016/j.applthermaleng.2023.120657</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Mathias</first_name>
      <last_name>Ehrenwirth</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Wilfried</first_name>
      <last_name>Zörner</last_name>
    </author>
    <author>
      <first_name>Kaj</first_name>
      <last_name>Pischow</last_name>
    </author>
    <author>
      <first_name>Richard</first_name>
      <last_name>Greenough</last_name>
    </author>
    <author>
      <first_name>Muyiwa</first_name>
      <last_name>Oyinlola</last_name>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulating glass</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Flat-plate collector</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Argon</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Gas concentration</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Efficiency measurement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Convective heat transfer</value>
    </subject>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="persons" number="26227">Zörner, Wilfried</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/3787/1-s2.0-S1359431123006865-main.pdf</file>
  </doc>
  <doc>
    <id>4996</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>205</pageFirst>
    <pageLast>211</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <articleNumber/>
    <type>conferenceobject</type>
    <publisherName>Atlantis Press</publisherName>
    <publisherPlace>Dordrecht</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>2024-08-13</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Potential of a Long-Term Predictive Controller for Managing Energy Storages to Reduce the Electric Grid-Load of an Air-Source Heat Pump</title>
    <abstract language="eng">Electrifying the domestic heating sector is mandatory to decarbonize the buildings sector but leads to additional peak loads in the public grid. Air-source heat pumps the mostly used technology in this regard even though, they suffer from lower efficiency during times of high heat demands. The usage of energy storages and predictive controllers enables operation shifting and hence offers potential to decrease the peak loads in the electric grid. This potential can be increased by using a longer prediction horizon as extended operation shifting can be performed. In this contribution, a methodology to derive the theoretical potential on the grid peak load reduction of such a long-term predictive controller is introduced. The electric load profile of an air-source heat pump in a typical German single-family home was generated based on different weather data scenarios for the city of Ingolstadt. Based on the profile the dependency between peak load reduction and required storage capacity was identified. In the case study a reduction of the peak load from 21 – 31% for an unrenovated building was achieved using a 500 L buffer storage. Further investigation needs to be done to derive a more realistic potential for renovated or new buildings.</abstract>
    <parentTitle language="eng">Proceedings of the International Renewable Energy Storage and Systems Conference (IRES 2023)</parentTitle>
    <identifier type="isbn">978-94-6463-455-6</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-49963</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:22:45Z","timestamp":1720657365408},"publisher-location":"Dordrecht","reference-count":0,"publisher":"Atlantis Press International BV","isbn-type":[{"value":"9789464634549","type":"print"},{"value":"9789464634556","type":"electronic"}],"license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"},{"start":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:00:00Z","timestamp":1720656000000},"content-version":"vor","delay-in-days":192,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024]]},"DOI":"10.2991\/978-94-6463-455-6_21","type":"book-chapter","created":{"date-parts":[[2024,7,10]],"date-time":"2024-07-10T06:02:10Z","timestamp":1720591330000},"page":"205-211","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Potential of a Long-Term Predictive Controller for Managing Energy Storages to Reduce the Electric Grid-Load of an Air-Source Heat Pump"],"prefix":"10.2991","author":[{"given":"David","family":"Schmitt","sequence":"first","affiliation":[]},{"given":"Tobias","family":"Reum","sequence":"additional","affiliation":[]},{"given":"Thorsten","family":"Summ","sequence":"additional","affiliation":[]},{"given":"Christoph","family":"Trinkl","sequence":"additional","affiliation":[]},{"given":"Tobias","family":"Schrag","sequence":"additional","affiliation":[]}],"member":"1574","published-online":{"date-parts":[[2024,7,11]]},"container-title":["Atlantis Highlights in Engineering","Proceedings of the International Renewable Energy Storage and Systems Conference (IRES 2023)"],"original-title":[],"language":"en","deposited":{"date-parts":[[2024,7,10]],"date-time":"2024-07-10T06:02:45Z","timestamp":1720591365000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.atlantis-press.com\/doi\/10.2991\/978-94-6463-455-6_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"ISBN":["9789464634549","9789464634556"],"references-count":0,"URL":"http:\/\/dx.doi.org\/10.2991\/978-94-6463-455-6_21","relation":{},"ISSN":["2731-7927","2589-4943"],"issn-type":[{"value":"2731-7927","type":"print"},{"value":"2589-4943","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024]]},"assertion":[{"value":"11 July 2024","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"IRES","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Renewable Energy Storage and Systems Conference","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Aachen","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Germany","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2023","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"27 November 2023","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"29 November 2023","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"ires-12023","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.eurosolar.org\/ires\/ires-conference-2023\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}</enrichment>
    <enrichment key="local_crossrefDocumentType">book-chapter</enrichment>
    <enrichment key="local_crossrefLicence">https://creativecommons.org/licenses/by-nc/4.0</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PublisherName,PublisherPlace,TitleMain_1,Language,TitleParent_1,PageNumber,PageFirst,PageLast,CompletedYear,IdentifierIsbn,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.2991/978-94-6463-455-6_21</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_conferenceName">17th International Renewable Energy Storage and Systems Conference (IRES 2023), Aachen (Germany) &amp; online, 28.-30.11.2023</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons BY-NC 4.0</licence>
    <author>
      <first_name>David</first_name>
      <last_name>Schmitt</last_name>
    </author>
    <editor>
      <first_name>Peter</first_name>
      <last_name>Droege</last_name>
    </editor>
    <author>
      <first_name>Tobias</first_name>
      <last_name>Reum</last_name>
    </author>
    <editor>
      <first_name>Lelia</first_name>
      <last_name>Quint</last_name>
    </editor>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Tobias</first_name>
      <last_name>Schrag</last_name>
    </author>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="persons" number="26717">Schrag, Tobias</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/4996/126001380.pdf</file>
  </doc>
  <doc>
    <id>4736</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>16</pageNumber>
    <edition/>
    <issue>8</issue>
    <volume>17</volume>
    <articleNumber>1908</articleNumber>
    <type>article</type>
    <publisherName>MDPI</publisherName>
    <publisherPlace>Basel</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">PV-Optimized Heat Pump Control in Multi-Family Buildings Using a Reinforcement Learning Approach</title>
    <abstract language="eng">For the energy transition in the residential sector, heat pumps are a core technology for decarbonizing thermal energy production for space heating and domestic hot water. Electricity generation from on-site photovoltaic (PV) systems can also contribute to a carbon-neutral building stock. However, both will increase the stress on the electricity grid. This can be reduced by using appropriate control strategies to match electricity consumption and production. In recent years, artificial intelligence-based approaches such as reinforcement learning (RL) have become increasingly popular for energy-system management. However, the literature shows a lack of investigation of RL-based controllers for multi-family building energy systems, including an air source heat pump, thermal storage, and a PV system, although this is a common system configuration. Therefore, in this study, a model of such an energy system and RL-based controllers were developed and simulated with physical models and compared with conventional rule-based approaches. Four RL algorithms were investigated for two objectives, and finally, the soft actor–critic algorithm was selected for the annual simulations. The first objective, to maintain only the required temperatures in the thermal storage, could be achieved by the developed RL agent. However, the second objective, to additionally improve the PV self-consumption, was better achieved by the rule-based controller. Therefore, further research on the reward function, hyperparameters, and advanced methods, including long short-term memory layers, as well as a training for longer time periods than six days are suggested.</abstract>
    <parentTitle language="eng">Energies</parentTitle>
    <identifier type="issn">1996-1073</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-47361</identifier>
    <enrichment key="opus.import.date">2024-05-07T09:02:27+00:00</enrichment>
    <enrichment key="opus.source">sword</enrichment>
    <enrichment key="opus.import.user">deepgreen</enrichment>
    <enrichment key="opus.import.file">attachment; filename=deposit.zip</enrichment>
    <enrichment key="opus.import.checksum">8b8e10c70c45a3bb55883535f9e60274</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.3390/en17081908</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Michael</first_name>
      <last_name>Bachseitz</last_name>
    </author>
    <author>
      <first_name>Muhammad</first_name>
      <last_name>Sheryar</last_name>
    </author>
    <author>
      <first_name>David</first_name>
      <last_name>Schmitt</last_name>
    </author>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Wilfried</first_name>
      <last_name>Zörner</last_name>
    </author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>reinforcement learning</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>PV-optimization</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>heat pump</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>multi-family building</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>energy-management system</value>
    </subject>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="persons" number="26227">Zörner, Wilfried</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="Import" number="deepgreen">DeepGreen</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/4736/energies-17-01908.pdf</file>
  </doc>
  <doc>
    <id>5361</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>19</pageNumber>
    <edition/>
    <issue>258</issue>
    <volume>2025</volume>
    <articleNumber>124594</articleNumber>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace>Amsterdam</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>2024-11-29</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Towards maximum cost-effectiveness: multi-objective design optimisation of insulating glass flat-plate collectors</title>
    <abstract language="eng">A significant challenge in the advancement of solar thermal heating systems lies in the unexplored techno-economic potential of insulating glass flat-plate collectors. These collectors are constructed in accordance with the specifications of standard insulating glass units and have emerged over the past decade as a promising design concept for enhancing the cost-effectiveness of solar thermal systems. However, substantial findings regarding the techno-economic viability of their production are still pending. The aim of this paper is to optimise insulating glass collector designs for solar district heating applications by identifying key design parameters that maximise cost-effectiveness. This study employed a five-stage methodology. It included thermo-hydraulic collector modelling using MATLAB/Simscape and the CARNOT Toolbox. The model was validated against experimental performance tests. A Latin hypercube computational design with 250,000 samples was set up to train supervised machine learning metamodels and perform a multi-objective optimisation using an elitist genetic algorithm. The study identified the argon concentration, collector length, and width as critical parameters influencing efficiency. Larger, thinner collectors demonstrated superior performance due to reduced convective losses and increased aperture-to-surface ratios. The optimisation revealed that the insulating glass collectors could achieve a 7.7 percentage point increase in efficiency, a 19.4 % reduction in material cost, and a 14.5 % decrease in weight compared to market-available flat-plate collectors. However, the direct economic comparison was not considered strong in evidence due to a lack of economic data from technology providers. The most cost-effective designs featured an argon concentration of 99 %, sealing thickness of 31.2 mm, and a glazing thickness of 4.1 mm, and 4.5 mm, while collector length and width varied more significantly. The research findings indicate the techno-economic potential of insulating glass collectors, demonstrating their ability to outperform conventional flat-plate collectors in terms of cost-effectiveness and efficiency. Future studies should focus on producing and testing larger modules and incorporating production costs to fully realise their potential for solar district heating applications. This study provides valuable guidelines for IGU designers and producers aiming to develop cost-effective and efficient solar thermal collectors for district heating systems.</abstract>
    <parentTitle language="eng">Applied Thermal Engineering</parentTitle>
    <identifier type="issn">1359-4311</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-53618</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,24]],"date-time":"2024-11-24T20:10:10Z","timestamp":1732479010699,"version":"3.28.0"},"reference-count":50,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T00:00:00Z","timestamp":1728518400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100021130","name":"Bundesministerium f\u00fcr Wirtschaft und Klimaschutz","doi-asserted-by":"publisher","award":["03ETW015-A"],"id":[{"id":"10.13039\/100021130","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Applied Thermal Engineering"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.applthermaleng.2024.124594","type":"journal-article","created":{"date-parts":[[2024,10,11]],"date-time":"2024-10-11T17:31:57Z","timestamp":1728667917000},"page":"124594","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"PC","title":["Towards maximum cost-effectiveness: multi-objective design optimisation of insulating glass flat-plate collectors"],"prefix":"10.1016","volume":"258","author":[{"given":"Thorsten","family":"Summ","sequence":"first","affiliation":[]},{"given":"Muyiwa","family":"Oyinlola","sequence":"additional","affiliation":[]},{"given":"Sanober","family":"Khattak","sequence":"additional","affiliation":[]},{"given":"Mathias","family":"Ehrenwirth","sequence":"additional","affiliation":[]},{"given":"Christoph","family":"Trinkl","sequence":"additional","affiliation":[]},{"given":"Wilfried","family":"Z\u00f6rner","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.applthermaleng.2024.124594_b0005","unstructured":"REN21 Secretariat, Renewables 2023 Global Status Report: Energy Supply, 2023, https:\/\/www.ren21.net\/gsr-2023\/, accessed 19 January 2024."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0010","doi-asserted-by":"crossref","DOI":"10.1016\/j.apenergy.2023.122154","article-title":"District heating potential in the EU-27: evaluating the impacts of heat demand reduction and market share growth","volume":"353","author":"Fallahnejad","year":"2024","journal-title":"Appl. Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0015","unstructured":"J. Brandes, M. Haun, D. Wrede, P. J\u00fcrgens, C. Kost, H.-M. Henning, Wege zu einem klimaneutralen Energiesystem: Update Klimaneutralit\u00e4t 2045. Update November 2021: Klimaneutralit\u00e4t 2045, 2021, https:\/\/www.ise.fraunhofer.de\/content\/dam\/ise\/de\/documents\/publications\/studies\/Fraunhofer-ISE-Studie-Wege-zu-einem-klimaneutralen-Energiesystem-Update-Klimaneutralitaet-2045.pdf."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0020","doi-asserted-by":"crossref","unstructured":"B.V. Mathiesen, K. Hansen, The role of Solar thermal in Future Energy Systems: Country cases for Germany, Italy, Austria and Denmark. Subtask A report in the IEA SHC Task 52 Programme, 2017.","DOI":"10.18777\/ieashc-task52-2017-0002"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0025","unstructured":"W. Weiss, M. Sp\u00f6rk-D\u00fcr, Solar Heat Worldwide: Global Market Development and Trends 2022 Detailed Market Figures 2021. Edition 2023, 2023, https:\/\/www.iea-shc.org\/Data\/Sites\/1\/publications\/Solar-Heat-Worldwide-2023.pdf, accessed 2 September 2023."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0030","unstructured":"B. Epp, IEA SHC investigates cost reduction potential of solar district heating, 2023, https:\/\/solarthermalworld.org\/news\/iea-shc-investigates-cost-reduction-potential-of-solar-district-heating\/, accessed 3 March 2023."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0035","doi-asserted-by":"crossref","DOI":"10.1016\/j.apenergy.2020.114997","article-title":"Large-scale solar thermal systems in leading countries: a review and comparative study of Denmark China, Germany and Austria","volume":"270","author":"Tschopp","year":"2020","journal-title":"Appl. Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0040","series-title":"Online-Symposium Solarthermie Und Innovative W\u00e4rmesysteme","first-page":"435","article-title":"Entwicklung eines Gro\u00dffl\u00e4chenkollektors in Isolierglasbauweise f\u00fcr den Einsatz in W\u00e4rmenetzen","author":"Summ","year":"2020"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0045","doi-asserted-by":"crossref","unstructured":"H. Riess, M. Kl\u00e4rner, W. Z\u00f6rner, R. Greenough, Thermal Simulation and Efficiency of a Hermetically Sealed Flat Plate Collector with a Fully Adhesive Edge Bond, in: International Solar Energy Society (Ed.), Proceedings of the ISES EuroSun 2016 Conference, Freiburg, Germany, 2016, pp. 1100\u20131113, doi: 10.18086\/eurosun.2016.07.07.","DOI":"10.18086\/eurosun.2016.07.07"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0050","doi-asserted-by":"crossref","DOI":"10.1016\/j.applthermaleng.2023.120657","article-title":"Effect of argon concentration on thermal efficiency of gas-filled insulating glass flat-plate collectors","author":"Summ","year":"2023","journal-title":"Appl. Therm. Eng."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0055","doi-asserted-by":"crossref","unstructured":"F. Giovannetti, M. Kirchner, Performance and Reliability of Insulated Glass Collector Prototypes, in: International Solar Energy Society (Ed.), Proceedings of the EuroSun 2014 Conference, Freiburg, Germany, 2015, pp. 355\u2013361, doi: 10.18086\/eurosun.2014.16.07.","DOI":"10.18086\/eurosun.2014.16.07"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0060","doi-asserted-by":"crossref","unstructured":"P. Leibbrandt, T. Schabbach, Numerical Investigation on Heat Transfer, Fluid Distribution and Solid Stress to a New Type of Solar Flat Plate Collector, in: International Solar Energy Society (Ed.), Proceedings of the EuroSun 2014 Conference, Freiburg, Germany, 2015, pp. 1\u201310, doi: 10.18086\/eurosun.2014.16.13.","DOI":"10.18086\/eurosun.2014.16.13"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0065","doi-asserted-by":"crossref","unstructured":"H. Riess, S. Brandmayr, W. Z\u00f6rner, A Novel Production Technique for Flat Plate Solar Collectors with a Fully Adhesive Edge Bond, in: International Solar Energy Society (Ed.), Proceedings of the EuroSun 2014 Conference, Freiburg, Germany, 2015, pp. 1\u20139, doi: 10.18086\/eurosun.2014.16.19.","DOI":"10.18086\/eurosun.2014.16.19"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0070","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.egypro.2014.02.025","article-title":"Analysis of the mechanical behaviour of an all-round fully adhesive supported absorber","volume":"48","author":"Riess","year":"2014","journal-title":"Energy Procedia"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0075","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.egypro.2014.02.008","article-title":"Development of an insulated glass solar thermal collector","volume":"48","author":"Giovannetti","year":"2014","journal-title":"Energy Procedia"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0080","doi-asserted-by":"crossref","unstructured":"T. Summ, B. Sturm, C. Scherer, C. Trinkl, W. Z\u00f6rner, Analysis of Thermo-Mechanical Stresses and Strains for a Novel Design of Insulating Glass Flat-Plate Collector, in: International Solar Energy Society (Ed.), Proceedings: ISES Solar World Congress 2023, 2024, pp. 372\u2013382, doi: 10.18086\/swc.2023.04.14.","DOI":"10.18086\/swc.2023.04.14"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0085","unstructured":"The MathWorks, Inc., Simscape, 2022, https:\/\/de.mathworks.com\/products\/simscape.html."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0090","unstructured":"Solar-Institut J\u00fclich, CARNOT Toolbox, 2023, https:\/\/www.fh-aachen.de\/forschung\/solar-institut-juelich\/carnot\/, accessed 14 January 2024."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0095","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.solener.2017.06.023","article-title":"Thermo-economic modeling and multi-objective optimization of solar water heater using flat plate collectors","volume":"155","author":"Hajabdollahi","year":"2017","journal-title":"Sol. Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0100","doi-asserted-by":"crossref","DOI":"10.1016\/j.solener.2023.112201","article-title":"Multi-objective optimizations of solar receiver based on deep learning strategy in different application scenarios","volume":"267","author":"Shuai","year":"2024","journal-title":"Sol. Energy"},{"journal-title":"Dissertation, M\u00fcnchen","article-title":"Theoretical and Experimental Analysis of Polymer-Based Solar Thermal Drain Back Systems","year":"2021","author":"Ehrenwirth","key":"10.1016\/j.applthermaleng.2024.124594_b0105"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0110","unstructured":"Deutsches Institut f\u00fcr Normung e. V., Solarenergie - Thermische Sonnenkollektoren - Pr\u00fcfverfahren (ISO 9806:2017); Deutsche Fassung EN ISO 9806:2017, Beuth Verlag GmbH, Berlin ICS 27.160, 2018."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0115","unstructured":"The MathWorks, Inc., MATLAB &amp; Simulink: Simscape Reference, 2022, https:\/\/de.mathworks.com\/help\/releases\/R2022b\/pdf_doc\/simscape\/simscape_ref.pdf, accessed 13 January 2024."},{"year":"1999","series-title":"Heat transfer","author":"Mills","key":"10.1016\/j.applthermaleng.2024.124594_b0120"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0125","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1002\/qj.49708938105","article-title":"Long-wave radiation from clear skies","volume":"89","author":"Swinbank","year":"1963","journal-title":"Quart J Royal Meteoro Soc"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0130","unstructured":"J.A. Duffie, W.A. Beckman, Solar engineering of thermal processes, Wiley, Hoboken, New Jersey, 2013. ISBN: 978-0-470-87366-3, http:\/\/site.ebrary.com\/lib\/alltitles\/docDetail.action?docID=10683270."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0135","unstructured":"Savosolar Oyi, Savosolar: The sun rises in the North!, 2017, https:\/\/meriauragroup.com\/wp-content\/uploads\/archive\/savosolar.com\/wp-content\/uploads\/Savosolar-DH-industrial-EN-1.pdf, accessed 27 January 2024."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0140","doi-asserted-by":"crossref","unstructured":"Verein Deutscher Ingenieure (Ed.), VDI-W\u00e4rmeatlas, 11th ed., Springer Vieweg, Berlin, 2013. ISBN: 978-3-642-19981-3. https:\/\/doi.org\/10.1007\/978-3-642-19981-3.","DOI":"10.1007\/978-3-642-19981-3"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0145","doi-asserted-by":"crossref","unstructured":"T. Summ, M. Abdalsalam, M. Ehrenwirth, C. Trinkl, W. Z\u00f6rner, A Detailed Investigation on the Convective Heat Transfer Inside the Enclosed Cavity of Insulated Glass Solar Thermal Flat-Plate Collectors, in: International Solar Energy Society (Ed.), Proceedings of the Solar World Congress 2021, 2021, doi:10.18086\/swc.2021.22.09.","DOI":"10.18086\/swc.2021.22.09"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0150","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/BF02560793","article-title":"Berechnung mittlerer W\u00e4rme- und Stoff\u00fcbergangskoeffizienten an laminar und turbulent \u00fcberstr\u00f6mten Einzelk\u00f6rpern mit Hilfe einer einheitlichen Gleichung","volume":"41","author":"Gnielinski","year":"1975","journal-title":"Forsch Ing-Wes"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0155","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1115\/1.3240948","article-title":"Simple and explicit formulas for the friction factor in turbulent pipe flow","volume":"105","author":"Haaland","year":"1983","journal-title":"J. Fluids Eng."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0160","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/0038-092X(80)90320-5","article-title":"Transmission of diffuse radiation through CPC and flat plate collector glazings","volume":"24","author":"Brandemuehl","year":"1980","journal-title":"Sol. Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0165","unstructured":"LISEC Austria GmbH, Anlagen f\u00fcr Isolierglasherstellung, 2023, https:\/\/www.lisec.com\/solutions\/systems-lines\/detail\/insulating-glass-line-for-thermoplastic-spacers\/fastlane-insulating-glass-line-for-thermoplastic-spacers-tpa#, accessed 2 December 2023."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0170","first-page":"239","article-title":"A comparison of three methods for selecting values of input variables in the analysis of output from a computer code","volume":"21","author":"Mckay","year":"1979","journal-title":"Technometrics"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0175","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1080\/03610927708827533","article-title":"Robust regression using iteratively reweighted least-squares","volume":"6","author":"Holland","year":"1977","journal-title":"Communications in Statistics - Theory and Methods"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0180","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1023\/A:1010933404324","article-title":"Random forests","volume":"45","author":"Breiman","year":"2001","journal-title":"Mach. Learn."},{"year":"2005","series-title":"Support Vector Machines: Theory and Applications","author":"Wang","key":"10.1016\/j.applthermaleng.2024.124594_b0185"},{"year":"2005","series-title":"Gaussian Processes for Machine Learning","author":"Rasmussen","key":"10.1016\/j.applthermaleng.2024.124594_b0190"},{"article-title":"Random Features for Large-Scale Kernel Machines","year":"2007","series-title":"Advances in Neural Information Processing Systems","author":"Rahimi","key":"10.1016\/j.applthermaleng.2024.124594_b0195"},{"year":"2017","series-title":"Classification And Regression Trees","author":"Breiman","key":"10.1016\/j.applthermaleng.2024.124594_b0200"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0205","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/j.renene.2016.12.095","article-title":"Machine learning methods for solar radiation forecasting: A review","volume":"105","author":"Voyant","year":"2017","journal-title":"Renew. Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0210","unstructured":"The MathWorks, Inc., Regression Learner App, 2022, https:\/\/www.mathworks.com\/help\/stats\/regression-learner-app.html."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0215","unstructured":"The MathWorks, Inc., bayesopt: Select optimal machine learning hyperparameters using Bayesian optimization, 2022, https:\/\/www.mathworks.com\/help\/releases\/R2022b\/stats\/bayesopt.html?s_tid=doc_ta, accessed 13 January 2024."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0220","doi-asserted-by":"crossref","DOI":"10.1098\/rsos.160125","article-title":"Fast methods for training Gaussian processes on large datasets","volume":"3","author":"Moore","year":"2016","journal-title":"R. Soc. Open Sci."},{"year":"2004","series-title":"Multi-objective optimization using evolutionary algorithms","author":"Deb","key":"10.1016\/j.applthermaleng.2024.124594_b0225"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0230","unstructured":"The MathWorks, Inc., Constrained Nonlinear Optimization Algorithms: fmincon Interior Point Algorithm, 2022, https:\/\/www.mathworks.com\/help\/releases\/R2022b\/optim\/ug\/constrained-nonlinear-optimization-algorithms.html?searchHighlight=Constrained%20Nonlinear%20Optimization%20Algorithms&amp;s_tid=doc_srchtitle, accessed 13 January 2024."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0235","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2015\/280694","article-title":"A dynamic multinode model for component-oriented thermal analysis of flat-plate solar collectors","volume":"2015","author":"Reiter","year":"2015","journal-title":"Journal of Solar Energy"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0240","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1002\/sam.11507","article-title":"A comparison of Gaussian processes and neural networks for computer model emulation and calibration","volume":"14","author":"Myren","year":"2021","journal-title":"Statistical Analysis"},{"key":"10.1016\/j.applthermaleng.2024.124594_b0245","unstructured":"Solar Heat Europe, The Solar Keymark Database: CEN Keymark Scheme, 2022, https:\/\/solarkeymark.eu\/database\/, accessed 24 November 2022."},{"key":"10.1016\/j.applthermaleng.2024.124594_b0250","article-title":"Statistical analysis of solar thermal collectors in the Solar Keymark Database","volume":"61","author":"Summ","year":"2024","journal-title":"Sustainable Energy Technol. Assess."}],"container-title":["Applied Thermal Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1359431124022622?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1359431124022622?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,11,24]],"date-time":"2024-11-24T19:31:12Z","timestamp":1732476672000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1359431124022622"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":50,"alternative-id":["S1359431124022622"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.applthermaleng.2024.124594","relation":{},"ISSN":["1359-4311"],"issn-type":[{"type":"print","value":"1359-4311"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Towards maximum cost-effectiveness: multi-objective design optimisation of insulating glass flat-plate collectors","name":"articletitle","label":"Article Title"},{"value":"Applied Thermal Engineering","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.applthermaleng.2024.124594","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"124594"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,Volume,CompletedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.1016/j.applthermaleng.2024.124594</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Muyiwa</first_name>
      <last_name>Oyinlola</last_name>
    </author>
    <author>
      <first_name>Sanober</first_name>
      <last_name>Khattak</last_name>
    </author>
    <author>
      <first_name>Mathias</first_name>
      <last_name>Ehrenwirth</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Wilfried</first_name>
      <last_name>Zörner</last_name>
    </author>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="persons" number="26227">Zörner, Wilfried</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/5361/1-s2.0-S1359431124022622-main.pdf</file>
  </doc>
  <doc>
    <id>4398</id>
    <completedYear/>
    <publishedYear>2023</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>9</pageNumber>
    <edition/>
    <issue>61</issue>
    <volume>2024</volume>
    <articleNumber>103581</articleNumber>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace>Amsterdam</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Statistical analysis of solar thermal collectors in the Solar Keymark Database</title>
    <abstract language="eng">Experimental, analytical, or numerical investigations are ordinarily conducted to reveal optimisation potential for solar thermal collectors. At the same time, the ‘Solar Keymark Database’ contains more than 2,000 test reports from certified laboratories featuring properties including thermal efficiency, dimensions, or optical properties. This dataset offers untapped potential for statistical analyses as an alternative optimisation approach. Hence, this paper aims to provide a) the first statistical findings of solar thermal collector properties listed in the Solar Keymark Database and b) insights into statistical relations between these properties. The key correlations observed from the analysis of flat-plate collectors were between efficiency and both gross height (R = 0.30) and gross area (R = 0.27). We concluded that preferable collector designs may be featured with larger area to height ratios. The analyses of evacuated tube collectors revealed a strong correlation between efficiency and transversal incidence angle modifier (R = -0.65) as a result from different tube spacing. It was noticeable that the quasi-dynamic test method reported significantly higher efficiencies (7.14 percentage points) for evacuated tube collectors, which should be carefully considered for future test procedures. Overall, the statistical analysis was in accordance with conventional bottom-up analyses and revealed insightful dependencies for the present collector data.</abstract>
    <parentTitle language="eng">Sustainable Energy Technologies and Assessments</parentTitle>
    <identifier type="issn">2213-1396</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-43981</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T00:26:48Z","timestamp":1704846408778},"reference-count":19,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,12,8]],"date-time":"2023-12-08T00:00:00Z","timestamp":1701993600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Sustainable Energy Technologies and Assessments"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.seta.2023.103581","type":"journal-article","created":{"date-parts":[[2023,12,13]],"date-time":"2023-12-13T23:26:25Z","timestamp":1702509985000},"page":"103581","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Statistical analysis of solar thermal collectors in the Solar Keymark Database"],"prefix":"10.1016","volume":"61","author":[{"ORCID":"http:\/\/orcid.org\/0000-0002-4712-1067","authenticated-orcid":false,"given":"Thorsten","family":"Summ","sequence":"first","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-5760-672X","authenticated-orcid":false,"given":"Muyiwa","family":"Oyinlola","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-5007-0969","authenticated-orcid":false,"given":"Sanober","family":"Khattak","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-1395-7819","authenticated-orcid":false,"given":"Christoph","family":"Trinkl","sequence":"additional","affiliation":[]},{"given":"Wilfried","family":"Z\u00f6rner","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.seta.2023.103581_b0005","doi-asserted-by":"crossref","unstructured":"Weiss W, Sp\u00f6rk-D\u00fcr M. Solar Heat Worldwide: Global Market Development and Trends 2021 Detailed Market Figures 2020. Edition 2022. [June 24, 2022]; Available from: https:\/\/www.iea-shc.org\/Data\/Sites\/1\/publications\/Solar-Heat-Worldwide-2022.pdf.","DOI":"10.18777\/ieashc-shw-2021-0001"},{"key":"10.1016\/j.seta.2023.103581_b0010","doi-asserted-by":"crossref","DOI":"10.1016\/j.apenergy.2020.115129","article-title":"Experimental and numerical analysis of an efficiently optimized evacuated flat plate solar collector under medium temperature","volume":"269","author":"Gao","year":"2020","journal-title":"Appl Energy"},{"issue":"2","key":"10.1016\/j.seta.2023.103581_b0015","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/S0038-092X(98)00122-4","article-title":"High Efficiency Evacuated Flat-Plate Solar Collector for Process Steam Production","volume":"65","author":"Benz","year":"1999","journal-title":"Sol Energy"},{"key":"10.1016\/j.seta.2023.103581_b0020","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.solener.2010.03.022","article-title":"Development of a new flat stationary evacuated CPC-collector for process heat applications","volume":"84","author":"Buttinger","year":"2010","journal-title":"Sol Energy"},{"issue":"19","key":"10.1016\/j.seta.2023.103581_b0025","doi-asserted-by":"crossref","first-page":"3093","DOI":"10.1016\/S0196-8904(03)00013-X","article-title":"Thermal performance of flat plate solar collector using various arrangements of compound honeycomb","volume":"44","author":"Abdullah","year":"2003","journal-title":"Energ Conver Manage"},{"key":"10.1016\/j.seta.2023.103581_b0030","doi-asserted-by":"crossref","first-page":"935","DOI":"10.1016\/j.solener.2020.06.059","article-title":"A review on recent development of thermal performance enhancement methods of flat plate solar water heater","volume":"206","author":"Vengadesan","year":"2020","journal-title":"Sol Energy"},{"key":"10.1016\/j.seta.2023.103581_b0035","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.rser.2018.11.014","article-title":"Performance enhancement analysis of The flat plate collectors: A comprehensive review","volume":"102","author":"Sakhaei","year":"2019","journal-title":"Renew Sustain Energy Rev"},{"key":"10.1016\/j.seta.2023.103581_b0040","article-title":"Systematic review of solar air collector technologies: Performance evaluation, structure design and application analysis","volume":"54","author":"Zhang","year":"2022","journal-title":"Sustainable Energy Technol Assess"},{"key":"10.1016\/j.seta.2023.103581_b0045","article-title":"Numerical and experimental study of thermal efficiency of a spiral flat plate solar collector by changing the spiral diameter, flow rate, and pipe diameter","volume":"53","author":"Aghakhani","year":"2022","journal-title":"Sustainable Energy Technol Assess"},{"key":"10.1016\/j.seta.2023.103581_b0050","article-title":"A detailed review on the performance of photovoltaic\/thermal system using various cooling methods","volume":"51","author":"Pathak","year":"2022","journal-title":"Sustainable Energy Technol Assess"},{"key":"10.1016\/j.seta.2023.103581_b0055","unstructured":"D. Institut f\u00fcr Normung e. V. Solarenergie -, Thermische Sonnenkollektoren - Pr\u00fcfverfahren (ISO 9806: 2017); Deutsche Fassung EN ISO 9806: 2017 (DIN EN ISO 9806 2018 Beuth Verlag GmbH Berlin 2018 \u201304)."},{"key":"10.1016\/j.seta.2023.103581_b0060","unstructured":"Solar Heat Europe. The Solar Keymark Database: CEN Keymark Scheme. [November 24, 2022]; Available from: https:\/\/solarkeymark.eu\/database\/."},{"key":"10.1016\/j.seta.2023.103581_b0065","article-title":"Performance optimization of flat plate solar collector through the integration of different slats arrangements made of transparent insulation material","volume":"46","author":"Ammar","year":"2021","journal-title":"Sustainable Energy Technol Assess"},{"key":"10.1016\/j.seta.2023.103581_b0070","article-title":"Numerical study on the thermal performance of photovoltaic thermal (PV\/T) collector with different parallel cooling channels","volume":"45","author":"Shen","year":"2021","journal-title":"Sustainable Energy Technol Assess"},{"key":"10.1016\/j.seta.2023.103581_b0075","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2020\/6671576","article-title":"Assessment of Uncertainties in Energetic and Exergetic Performances of a Flat Plate Solar Water Heater","volume":"2020","author":"Harrabi","year":"2020","journal-title":"Math Probl Eng"},{"issue":"7","key":"10.1016\/j.seta.2023.103581_b0080","doi-asserted-by":"crossref","first-page":"756","DOI":"10.3390\/pr8070756","article-title":"Thermal Performance Enhancement in Flat Plate Solar Collector Solar Water Heater: A Review","volume":"8","author":"Shamsul Azha","year":"2020","journal-title":"Processes"},{"key":"10.1016\/j.seta.2023.103581_b0085","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.enconman.2018.04.039","article-title":"Optimization of a solar collector with evacuated tubes using the simulated annealing and computational fluid dynamics","volume":"166","author":"Alfaro-Ayala","year":"2018","journal-title":"Energ Conver Manage"},{"issue":"4","key":"10.1016\/j.seta.2023.103581_b0090","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.renene.2008.06.014","article-title":"Exergetic optimization of flat plate solar collectors","volume":"34","author":"Farahat","year":"2009","journal-title":"Renew Energy"},{"issue":"2","key":"10.1016\/j.seta.2023.103581_b0095","article-title":"Design Optimization and Experimental Validation of Low-Cost Flat Plate Collector Under Central Qasssim Climate","volume":"7","author":"Nejlaoui","year":"2021","journal-title":"Journal of Applied and Computational Mechanics"}],"container-title":["Sustainable Energy Technologies and Assessments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221313882300574X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S221313882300574X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,1,9]],"date-time":"2024-01-09T05:21:03Z","timestamp":1704777663000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S221313882300574X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":19,"alternative-id":["S221313882300574X"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.seta.2023.103581","relation":{},"ISSN":["2213-1388"],"issn-type":[{"value":"2213-1388","type":"print"}],"subject":["Energy Engineering and Power Technology","Renewable Energy, Sustainability and the Environment"],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Statistical analysis of solar thermal collectors in the Solar Keymark Database","name":"articletitle","label":"Article Title"},{"value":"Sustainable Energy Technologies and Assessments","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.seta.2023.103581","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"103581"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">SubjectUncontrolled_1,SubjectUncontrolled_2,PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorIdentifierOrcid_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorIdentifierOrcid_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorIdentifierOrcid_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorIdentifierOrcid_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,Volume,CompletedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.1016/j.seta.2023.103581</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Muyiwa</first_name>
      <last_name>Oyinlola</last_name>
    </author>
    <author>
      <first_name>Sanober</first_name>
      <last_name>Khattak</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Wilfried</first_name>
      <last_name>Zörner</last_name>
    </author>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="persons" number="26227">Zörner, Wilfried</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/4398/1-s2.0-S221313882300574X-main.pdf</file>
  </doc>
  <doc>
    <id>5271</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber>17</pageNumber>
    <edition/>
    <issue>312</issue>
    <volume>2024</volume>
    <articleNumber>133585</articleNumber>
    <type>article</type>
    <publisherName>Elsevier</publisherName>
    <publisherPlace>Amsterdam</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>2024-10-25</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Technical and economic analysis of digitally controlled substations in local district heating networks</title>
    <abstract language="eng">Since the 1990s, there has been a noticeable increase in the establishment of local district heating networks in Germany, coinciding with the use of thermal energy from biogas and biomass facilities. Historically, the prioritization of economically efficient heat utilization was subdued due to favorable electricity feed-in tariffs. However, with the expiration of Renewable Energy Sources Act subsidies, operators shifted focus to the operational costs of district heating networks. This study aims to examine the effects of optimizing controllers and valves at district heating substations in single-family homes, utilizing two local district heating networks. The emphasis is on evaluating impacts on operating costs and determining whether the economic and energetic benefits justify implementation. Simulation studies in MATLAB/Simulink Simscape depict both consumers and district heating networks individually, without aggregation. In the most favorable scenario, investing in enhancing substation controllers in single-family homes is projected to yield returns after 13 years. Comprehensive optimization of all substation controls in single-family homes can potentially result in up to 9% savings in thermal energy demand due to reduced heat losses and a corresponding 9% reduction in electrical power consumption for the main pump.</abstract>
    <parentTitle language="eng">Energy</parentTitle>
    <identifier type="issn">0360-5442</identifier>
    <identifier type="urn">urn:nbn:de:bvb:573-52718</identifier>
    <identifier type="issn">1873-6785</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T04:22:56Z","timestamp":1729743776021,"version":"3.28.0"},"reference-count":44,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Energy"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.energy.2024.133585","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T16:37:28Z","timestamp":1729701448000},"page":"133585","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Technical and economic analysis of digitally controlled substations in local district heating networks"],"prefix":"10.1016","author":[{"ORCID":"http:\/\/orcid.org\/0000-0003-2980-0469","authenticated-orcid":false,"given":"Anna","family":"Vannahme","sequence":"first","affiliation":[]},{"given":"Dharmik","family":"Patel","sequence":"additional","affiliation":[]},{"given":"David","family":"Schmitt","sequence":"additional","affiliation":[]},{"given":"Thorsten","family":"Summ","sequence":"additional","affiliation":[]},{"given":"Christoph","family":"Trinkl","sequence":"additional","affiliation":[]},{"given":"Tobias","family":"Schrag","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.energy.2024.133585_bib1","article-title":"Gesetz f\u00fcr den Vorrang erneuerbarer Energien (Erneuerbare-Energien-Gesetz - EEG): Synoptische Gegen\u00fcberstellung des Stromeinspeisungsgesetzes 1998, des Gesetzentwurfs vom Dezember 1999 und des endg\u00fcltigen Gesetzestextes","author":"Oschmann","year":"2000","journal-title":"Zeitschrift f\u00fcr neues Energierecht"},{"key":"10.1016\/j.energy.2024.133585_bib2","unstructured":"Fachverband Biogas. Anzahl der Biogasanlagen in Deutschland in den Jahren 1992 bis 2022.: Biogas Branchenzahlen 2021 und Prognose der Branchenentwilckungl 2022. [March 21, 2023]; Available from: https:\/\/de.statista.com\/statistik\/daten\/studie\/167671\/umfrage\/anzahl-der-biogasanlagen-in-deutschland-seit-1992\/."},{"key":"10.1016\/j.energy.2024.133585_bib3","doi-asserted-by":"crossref","DOI":"10.1016\/j.energy.2024.131226","article-title":"Development and Application of a Guideline for Assessing Optimization Potentials for District Heating Systems","author":"Vannahme","year":"2024","journal-title":"Energy. The International Journal"},{"key":"10.1016\/j.energy.2024.133585_bib4","unstructured":"DassaultSystem. Dymola. Available online: https:\/\/www.3ds.com\/products-services\/catia\/products\/dymola\/ (accessed on 1 September 2018)."},{"key":"10.1016\/j.energy.2024.133585_bib5","doi-asserted-by":"crossref","unstructured":"Wetter M, Fuchs M, Grozman P, Helsen, L., Jorissen, F., Lauter, M., M\u00fcller D, Nytsch-Geusen C et al. IEA EBC annex 60 modelica library-an international collaboration to develop a free open-source model library for buildings and community energy systems. Proceedings of building simulation 2015:395\u2013402.","DOI":"10.26868\/25222708.2015.2414"},{"key":"10.1016\/j.energy.2024.133585_bib6","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1016\/j.energy.2018.06.192","article-title":"Simulation based evaluation of large scale waste heat utilization in urban district heating networks: Optimized integration and operation of a seasonal storage","volume":"159","author":"K\u00f6finger","year":"2018","journal-title":"Energy"},{"key":"10.1016\/j.energy.2024.133585_bib7","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1016\/j.rser.2017.06.109","article-title":"Models for fast modelling of district heating and cooling networks","volume":"82","author":"del","year":"2018","journal-title":"Renewable and Sustainable Energy Reviews"},{"key":"10.1016\/j.energy.2024.133585_bib8","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.simpat.2018.11.008","article-title":"A comparative study of two simulation tools for the technical feasibility in terms of modeling district heating systems: An optimization case study","volume":"91","author":"Dahash","year":"2019","journal-title":"Simulation Modelling Practice and Theory"},{"key":"10.1016\/j.energy.2024.133585_bib9","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.enconman.2014.10.002","article-title":"A method for the simulation and optimization of district heating systems with meshed networks","volume":"89","author":"Vesterlund","year":"2015","journal-title":"Energy Conversion and Management"},{"key":"10.1016\/j.energy.2024.133585_bib10","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.enconman.2016.04.074","article-title":"A method for the steady-state thermal simulation of district heating systems and model parameters calibration","volume":"120","author":"Wang","year":"2016","journal-title":"Energy Conversion and Management"},{"key":"10.1016\/j.energy.2024.133585_bib11","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.enconman.2018.03.034","article-title":"Thermo-economic optimization of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series","volume":"165","author":"Tian","year":"2018","journal-title":"Energy Conversion and Management"},{"key":"10.1016\/j.energy.2024.133585_bib12","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.energy.2017.09.135","article-title":"Analysis and validation of a quasi-dynamic model for a solar collector field with flat plate collectors and parabolic trough collectors in series for district heating","volume":"142","author":"Tian","year":"2018","journal-title":"Energy"},{"key":"10.1016\/j.energy.2024.133585_bib13","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/j.egypro.2015.02.163","article-title":"Towards Solar District Heating with More than 70% Solar Fraction","volume":"70","author":"Trier","year":"2015","journal-title":"Energy Procedia"},{"key":"10.1016\/j.energy.2024.133585_bib14","unstructured":"Rebollar JV, Himpe E, Janssens A. Performance assessment of district heating substations based on dynamic simulations. In: Proceedings of the 9th International Conference on Simulation and Modeling Methodologies, Technologies and Applications. SCITEPRESS - Science and Technology Publications; 2019."},{"issue":"7-8","key":"10.1016\/j.energy.2024.133585_bib15","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1016\/j.enconman.2003.08.006","article-title":"A comparison of aggregated models for simulation and operational optimisation of district heating networks","volume":"45","author":"Larsen","year":"2004","journal-title":"Energy Conversion and Management"},{"key":"10.1016\/j.energy.2024.133585_bib16","doi-asserted-by":"crossref","unstructured":"Gustafsson J, Delsing J, van Deventer J. Thermodynamic Simulation of a Detached House with District Heating Subcentral. SysCon 2008 - IEEE International Systems Conference 2008;2008.","DOI":"10.1109\/SYSTEMS.2008.4519054"},{"key":"10.1016\/j.energy.2024.133585_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.energy.2017.05.115","article-title":"District heating and cooling systems \u2013 Framework for Modelica-based simulation and dynamic optimization","author":"Schweiger","year":"2017","journal-title":"Energy"},{"key":"10.1016\/j.energy.2024.133585_bib18","doi-asserted-by":"crossref","unstructured":"Ikonen E, Selek I, Kovacs J, Neuvonen M, Szabo Z, Bene J et al. Short term optimization of district heating network supply temperatures. In: 2014 IEEE International Energy Conference (ENERGYCON). IEEE; 2014, p. 996\u20131003.","DOI":"10.1109\/ENERGYCON.2014.6850547"},{"key":"10.1016\/j.energy.2024.133585_bib19","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1016\/j.energy.2018.09.141","article-title":"Operational optimization in district heating systems with the use of thermal energy storage","volume":"165","author":"Le\u015bko","year":"2018","journal-title":"Energy"},{"key":"10.1016\/j.energy.2024.133585_bib20","doi-asserted-by":"crossref","DOI":"10.1016\/j.energy.2020.117650","article-title":"A simulation-based evaluation of substation models for network flexibility characterisation in district heating networks","volume":"201","author":"Vandermeulen","year":"2020","journal-title":"Energy"},{"issue":"3","key":"10.1016\/j.energy.2024.133585_bib21","article-title":"Impact of network modelling in the analysis of district heating systems","volume":"213","author":"Guelpa","year":"2020","journal-title":"Energy"},{"issue":"6","key":"10.1016\/j.energy.2024.133585_bib22","doi-asserted-by":"crossref","first-page":"1996","DOI":"10.1016\/j.apenergy.2009.12.015","article-title":"Improved district heating substation efficiency with a new control strategy","volume":"87","author":"Gustafsson","year":"2010","journal-title":"Applied Energy"},{"key":"10.1016\/j.energy.2024.133585_bib23","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1016\/j.enbuild.2017.11.049","article-title":"Improving thermal performance of an existing UK district heat network: A case for temperature optimization","volume":"158","author":"Tunzi","year":"2018","journal-title":"Energy and Buildings"},{"key":"10.1016\/j.energy.2024.133585_bib24","doi-asserted-by":"crossref","DOI":"10.1016\/j.energy.2021.120250","article-title":"What does a well-functioning heating system look like? Investigation of ten Danish buildings that utilize district heating efficiently","volume":"227","author":"\u00d8stergaard","year":"2021","journal-title":"Energy"},{"key":"10.1016\/j.energy.2024.133585_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.segy.2023.100105","article-title":"Testing and evaluation of a smart controller for reducing peak loads and return temperatures in district heating networks","volume":"10","author":"van Oevelen","year":"2023","journal-title":"Smart Energy"},{"key":"10.1016\/j.energy.2024.133585_bib26","unstructured":"Frederiksen S, Werner S. District heating and cooling. Lund: Studentlitteratur; 2013."},{"key":"10.1016\/j.energy.2024.133585_bib27","unstructured":"Persson T. District heating for residential areas with single-family housing: With special emphasis on domestic hot water comfort. Lund: Dept. of Heat and Power Engineering, Univ; 2005."},{"key":"10.1016\/j.energy.2024.133585_bib28","unstructured":"AGFW | Der Energieeffizienzverband f\u00fcr W\u00e4rme, K\u00e4lte und KWK e. V. Merkblatt AGFW FW 523 Teil 1: Trinkwassererw\u00e4rmungssysteme-Vergleich \/ Comparison of drinking water heating systems; 2015."},{"key":"10.1016\/j.energy.2024.133585_bib29","unstructured":"Samson. Einbau- und Bedienungsanleitung: EB 2171. Originalanleitung. Temperaturregler - Typ 43-1 - Typ 43-2;2019."},{"key":"10.1016\/j.energy.2024.133585_bib30","unstructured":"Vannahme A, Schmitt D, Summ T, Trinkl C, Schrag T, Blab, Sebastian, Heinloth, Ludwig. Abschlussbericht Verbundvorhaben: EnEff: W\u00e4rme \u2013 OREWA: Optimierung und Restrukturierung von W\u00e4rmenetzen einschlie\u00dflich der Bewertung von \u00dcbertragbarkeit, \u00d6kologie und \u00d6konomie; Available from: https:\/\/www.enargus.de\/pub\/bscw.cgi\/?op=enargus.eps2&amp;q=OREWA&amp;v=10&amp;id=1276450."},{"issue":"5","key":"10.1016\/j.energy.2024.133585_bib31","doi-asserted-by":"crossref","DOI":"10.3390\/resources10050053","article-title":"Enhancement of a District Heating Substation as Part of a Low-Invest Optimization Strategy for District Heating Systems","volume":"10","author":"Vannahme","year":"2021","journal-title":"Resources"},{"key":"10.1016\/j.energy.2024.133585_bib32","unstructured":"Hafner Bea. Carnot Blockset Version 1.0 - Conventional and renewable enrgy systems optimization blockset - User's guide. Solar-Institut J\u00fclich, Fachhochschule 1999."},{"key":"10.1016\/j.energy.2024.133585_bib33","unstructured":"Verein Deutscher Ingenieure. VDI-Richtlinie VDI 4655. Referenzlastprofile von Wohngeb\u00e4uden f\u00fcr Strom, Heizung und Trinkwarmwasser sowie Referenzerzeugungsprofile f\u00fcr Fotovoltaikanlagen Reference load profiles of residential buildings for power, heat, and domestic hot water as well as reference generation profiles for photovoltaic plants VDI 4655 Ausg. Berlin: Beuth Verlag GmbH; 2021. [January 11, 2022]."},{"key":"10.1016\/j.energy.2024.133585_bib34","unstructured":"Aldenderfer MS, Blashfield RK. Cluster analysis. 22nd ed. Newbury Park (Ca): Sage; 1987."},{"issue":"2","key":"10.1016\/j.energy.2024.133585_bib35","article-title":"Multidimensional analysis of excitonic spectra of monolayers of tungsten disulphide: toward computer-aided identification of structural and environmental perturbations of 2D materials","volume":"2","author":"Kolesnichenko","year":"2021","journal-title":"Mach. Learn.: Sci. Technol."},{"key":"10.1016\/j.energy.2024.133585_bib36","unstructured":"The MathWorks, Inc. Matlab (R2022a). [September 04, 2023]; Available from: https:\/\/de.mathworks.com\/products\/new_products\/release2022a.html."},{"key":"10.1016\/j.energy.2024.133585_bib37","article-title":"Dekarbonisierung von Energieinfrastrukturen: Ein politischer Unterst\u00fctzungsrahmen f\u00fcr das Beispiel W\u00e4rmenetze Abschlussbericht","author":"Ortner","year":"2023","journal-title":"Dessau-Ro\u00dflau: Umweltbundesamt"},{"key":"10.1016\/j.energy.2024.133585_bib38","unstructured":"Diefenbach N, Loga T, Born R, Gro\u00dfklos M, Herbert C. Energetische Kenngr\u00f6\u00dfen f\u00fcr Heizungsanlagen im Bestand: Eine Untersuchung im Auftrag des Ingenieurb\u00fcros f\u00fcr energieeffiziente Geb\u00e4udetechnik VENTECS, Bremen. Darmstadt; 2002."},{"key":"10.1016\/j.energy.2024.133585_bib39","doi-asserted-by":"crossref","unstructured":"Terstege U, Bitz M, Ewert J. Investitionsrechnung klipp &amp; klar. Wiesbaden: Springer Gabler; 2019.","DOI":"10.1007\/978-3-658-20992-6"},{"key":"10.1016\/j.energy.2024.133585_bib40","unstructured":"Holm A, Mayer C, Sprengard C. Wirtschaftlichkeit von w\u00e4rmed\u00e4mmenden Ma\u00dfnahmen - Kritische Bewrtung von unterschiedlichen Methoden und Einflussfaktoren. [January 30, 2023]; Available from: https:\/\/xps-spezialdaemmstoff.de\/wp-content\/uploads\/2014-12-4-Wirtschaftlichkeit-von-waermedaemmenden-Massnahmen.pdf."},{"key":"10.1016\/j.energy.2024.133585_bib41","unstructured":"Deutsche Bundesbank. Effektivzinssatz f\u00fcr Kredite (Neugesch\u00e4ft) an nichtfinanzielle Kapitalgesellschaften in Deutschland von 2003 bis 2022. [October 14, 2023]; Available from: htttps:\/\/de.statistsa.com\/statistik\/daten\/studie\/899113\/umfrage\/zinssatz-fuer-kredite-neugeschaeft-an-nichtfinanzielle-kapitalgeselsschaften\/."},{"key":"10.1016\/j.energy.2024.133585_bib42","unstructured":"Statistisches Bundesamt (Destatis) 2. Verbraucherpreisindex f\u00fcr Deutschland von 2000 bis 2022; Available from: https:\/\/www-genesis.destatis.de\/genesis\/online?operation=abruftabelleBearbeiten&amp;levelindex=1&amp;levelid=1697274627895&amp;auswahloperation=abruftabelleAuspraegungAuswaehlen&amp;auswahlverzeichnis=ordnungsstruktur&amp;auswahlziel=werteabruf&amp;code=61111-0001&amp;auswahltext=&amp;werteabruf=Werteabruf#abreadcrumb."},{"key":"10.1016\/j.energy.2024.133585_bib43","unstructured":"Bundesnetzagentur, Bundeskartellamt. Monitoringbericht 2022. [December 13, 2022]; Available from: https:\/\/www.bundesnetzagentur.de\/DE\/Sachgebiete\/ElektrizitaetundGas\/Unternehmen_Institutionen\/Monitoringberichte\/start.html."},{"key":"10.1016\/j.energy.2024.133585_bib44","unstructured":"Grebe C, Issler R, Karpenstein-Machan M, Baub\u00f6ck R, Kappas M, Schmuck P et al. Vom Bioenergiedorf zum Energiewendedorf: Leitfaden. 2022nd ed. Kassel, G\u00f6ttingen: Universit\u00e4t Kassel; Georg-August-Universit\u00e4t; 2022."}],"container-title":["Energy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360544224033632?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360544224033632?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T16:37:43Z","timestamp":1729701463000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0360544224033632"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":44,"alternative-id":["S0360544224033632"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.energy.2024.133585","relation":{},"ISSN":["0360-5442"],"issn-type":[{"value":"0360-5442","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Technical and economic analysis of digitally controlled substations in local district heating networks","name":"articletitle","label":"Article Title"},{"value":"Energy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.energy.2024.133585","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"133585"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorIdentifierOrcid_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,CompletedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="THI_relatedIdentifier">https://doi.org/10.1016/j.energy.2024.133585</enrichment>
    <enrichment key="THI_articleversion">published</enrichment>
    <enrichment key="THI_review">peer-review</enrichment>
    <enrichment key="THI_openaccess">ja</enrichment>
    <licence>Creative Commons BY 4.0</licence>
    <author>
      <first_name>Anna</first_name>
      <last_name>Vannahme</last_name>
    </author>
    <author>
      <first_name>Dharmik</first_name>
      <last_name>Patel</last_name>
    </author>
    <author>
      <first_name>David</first_name>
      <last_name>Schmitt</last_name>
    </author>
    <author>
      <first_name>Thorsten</first_name>
      <last_name>Summ</last_name>
    </author>
    <author>
      <first_name>Christoph</first_name>
      <last_name>Trinkl</last_name>
    </author>
    <author>
      <first_name>Tobias</first_name>
      <last_name>Schrag</last_name>
    </author>
    <collection role="institutes" number="15985">Fakultät Maschinenbau</collection>
    <collection role="open_access" number="">open_access</collection>
    <collection role="institutes" number="19321">Institut für neue Energie-Systeme (InES)</collection>
    <collection role="persons" number="26717">Schrag, Tobias</collection>
    <thesisPublisher>Technische Hochschule Ingolstadt</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-haw/files/5271/1-s2.0-S0360544224033632-main.pdf</file>