@article{IgiligiVielhauerEhrenwirthetal.2023, author = {Igiligi, Anthony and Vielhauer, Armin and Ehrenwirth, Mathias and Hurm, Christian and Summ, Thorsten and Trinkl, Christoph and Navarro Gevers, Daniel}, title = {Assessment of Conservation Voltage Reduction in Distribution Networks with Voltage Regulating Distribution Transformers}, volume = {16}, pages = {3155}, journal = {Energies}, number = {7}, publisher = {MDPI}, address = {Basel}, issn = {1996-1073}, doi = {https://doi.org/10.3390/en16073155}, year = {2023}, abstract = {The application of voltage reduction in medium and low voltage grids to reduce peak power demand or energy consumption has been implemented since the 1980s using several approaches. Conservation Voltage Reduction (CVR), as one such approach, uses a voltage control device to reduce or increase the voltage setpoint on a busbar, thereby reducing or increasing the amount of active and reactive power supply in the network. Voltage regulation for CVR is always implemented according to established network planning standards in each country. Research in this field has proven that a CVR factor (CVRf) of 0.7-1.5 for peak demand reduction can be achieved. This is an evaluation metric of CVR. The aim of this research is to determine and validate CVRf for peak demand reduction by comparing actual results obtained during regular tap changes with other randomly distributed periods outside tap change operations, using a set of measurement data. It is important to understand CVR deployment capability by evaluating CVR potentials from historical random tap operations before a robust network-wide deployment is introduced. This research provides such guidance. It also provides a novel approach to determining tap changes from voltage measurements using a time-based algorithm. A CVRf ranging from 0.95 to 1.61 was estimated using a measurement dataset from a test field. The result of the entire evaluation shows that the CVRf are smaller during peak PV production and greater during peak demand periods. Further evaluation using statistical hypotheses testing and a control chart was used to validate the evaluation.}, language = {en} } @article{SummEhrenwirthTrinkletal.2023, author = {Summ, Thorsten and Ehrenwirth, Mathias and Trinkl, Christoph and Z{\"o}rner, Wilfried and Pischow, Kaj and Greenough, Richard and Oyinlola, Muyiwa}, title = {Effect of argon concentration on thermal efficiency of gas-filled insulating glass flat-plate collectors}, volume = {2023}, pages = {120657}, journal = {Applied Thermal Engineering}, number = {230, Part A}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-5606}, doi = {https://doi.org/10.1016/j.applthermaleng.2023.120657}, year = {2023}, abstract = {Insulating glass flat-plate collectors can save cost by being produced quickly and automatically in insulated glass production facilities, and they can be filled with argon to reduce heat loss. During its lifetime, the collector is likely to lose argon because of gradual material degradation of the sealing. However, information on the influence of the argon concentration on the collector efficiency is limited. Therefore, the objective of this research work was to analyse this effect. A theoretical material property calculation of argon-air mixtures was carried out to determine the convective losses with variable argon concentrations. Thermal collector performance was measured experimentally using an outdoor solar tracker test rig. The results strongly suggest, that the influence of argon concentration on both the convective losses and the thermal efficiency is non-linear. The measurements revealed that an argon concentration of 90 \% can increase average thermal performance by 6.7 ± 4.8 percentage points. An increase in argon concentration from 0 \% to 50 \% has almost twice the effect on average thermal efficiency as an increase from 50 \% to 90 \%. Concluding from these results, an argon leakage threshold of 2.5 percentage points per year is proposed to avoid disproportionate loss of efficiency over time.}, language = {en} } @article{VannahmeEhrenwirthSchrag2024, author = {Vannahme, Anna and Ehrenwirth, Mathias and Schrag, Tobias}, title = {Development and application of a guideline for assessing optimization potentials for district heating systems}, volume = {2024}, pages = {131226}, journal = {Energy}, number = {297}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1873-6785}, doi = {https://doi.org/10.1016/j.energy.2024.131226}, year = {2024}, abstract = {Integrating renewable energies into district heating systems has a large potential to reduce CO2-emissions in the heating sector. As district heating systems offer the possibility of incorporating renewable energies into the heat supply, new systems have to be built and the existing networks must be maintained. This study investigates ways to optimize existing district heating systems in order to ensure economic sustainability in the long-term. Previous case studies have elaborated on a variety of optimization measures. However, to date, these measures have neither been collected nor consistently assessed for a wider application range. Therefore, in the study presented here a system for assessing the ecological and economic benefits of optimization measures was developed and applied. The assessment method utilized showed that optimization of district heating consumer substations and adding of a central buffer storage tank has a high optimization potential in comparison to intermittent operation strategy, which has a significantly lower optimization potential. From this information and the transferability data, a district heating operator can determine which optimization measure should be prioritized, which is shown at the end of the paper on an example case.}, language = {en} } @article{SummOyinlolaKhattaketal.2024, author = {Summ, Thorsten and Oyinlola, Muyiwa and Khattak, Sanober and Ehrenwirth, Mathias and Trinkl, Christoph and Z{\"o}rner, Wilfried}, title = {Towards maximum cost-effectiveness: multi-objective design optimisation of insulating glass flat-plate collectors}, volume = {2025}, pages = {124594}, journal = {Applied Thermal Engineering}, number = {258}, publisher = {Elsevier}, address = {Amsterdam}, issn = {1359-4311}, doi = {https://doi.org/10.1016/j.applthermaleng.2024.124594}, year = {2024}, abstract = {A significant challenge in the advancement of solar thermal heating systems lies in the unexplored techno-economic potential of insulating glass flat-plate collectors. These collectors are constructed in accordance with the specifications of standard insulating glass units and have emerged over the past decade as a promising design concept for enhancing the cost-effectiveness of solar thermal systems. However, substantial findings regarding the techno-economic viability of their production are still pending. The aim of this paper is to optimise insulating glass collector designs for solar district heating applications by identifying key design parameters that maximise cost-effectiveness. This study employed a five-stage methodology. It included thermo-hydraulic collector modelling using MATLAB/Simscape and the CARNOT Toolbox. The model was validated against experimental performance tests. A Latin hypercube computational design with 250,000 samples was set up to train supervised machine learning metamodels and perform a multi-objective optimisation using an elitist genetic algorithm. The study identified the argon concentration, collector length, and width as critical parameters influencing efficiency. Larger, thinner collectors demonstrated superior performance due to reduced convective losses and increased aperture-to-surface ratios. The optimisation revealed that the insulating glass collectors could achieve a 7.7 percentage point increase in efficiency, a 19.4 \% reduction in material cost, and a 14.5 \% decrease in weight compared to market-available flat-plate collectors. However, the direct economic comparison was not considered strong in evidence due to a lack of economic data from technology providers. The most cost-effective designs featured an argon concentration of 99 \%, sealing thickness of 31.2 mm, and a glazing thickness of 4.1 mm, and 4.5 mm, while collector length and width varied more significantly. The research findings indicate the techno-economic potential of insulating glass collectors, demonstrating their ability to outperform conventional flat-plate collectors in terms of cost-effectiveness and efficiency. Future studies should focus on producing and testing larger modules and incorporating production costs to fully realise their potential for solar district heating applications. This study provides valuable guidelines for IGU designers and producers aiming to develop cost-effective and efficient solar thermal collectors for district heating systems.}, language = {en} } @article{MehtaLwakatareZoerneretal.2025, author = {Mehta, Kedar and Lwakatare, Bertha and Z{\"o}rner, Wilfried and Ehrenwirth, Mathias}, title = {Mini-grid performance in Sub-Saharan Africa: case studies from Tsumkwe and Gam, Namibia}, volume = {12}, pages = {30}, journal = {Sustainable Energy Research}, number = {1}, publisher = {SpringerOpen}, address = {Singapore}, issn = {2731-9237}, doi = {https://doi.org/10.1186/s40807-025-00174-y}, year = {2025}, abstract = {This paper investigates the performance analysis and operational challenges of mini-grids in Sub-Saharan Africa, focusing on the Tsumkwe and Gam mini-grids, the only officially recognized mini-grids in Namibia. The study addresses a critical gap in understanding mini-grid efficiency, technical difficulties, and future potential. The key research questions focus on assessing mini-grid performance, identifying technical and operational challenges, quantifying the relationship between electricity demand and supply, and providing recommendations for enhancing rural electrification through mini-grids. These insights are crucial for evaluating the effectiveness of mini-grids in the African context and understanding their role in advancing rural electrification. By using a mixed-method approach, the research combines quantitative and qualitative data to offer a comprehensive analysis of these two mini-grid systems of Namibia. The data collected from 2017 to 2022 include metrics on energy supply, consumption, photovoltaic generation, community load, and meteorological conditions. Qualitative insights were gathered through field visits, surveys, and interviews with mini-grid operators, allowing for a thorough examination of community perspectives, operational issues, and technical performance. The findings reveal that the Tsumkwe mini-grid has seen a decline in efficiency due to maintenance problems and battery overheating, while the Gam mini-grid, initially oversized, now struggles with increased demand and new connections. This study provides the first detailed technical insights, identifies consumer archetypes, and evaluates the energy dynamics of mini-grids in Namibia. Recommendations include improved maintenance protocols, advanced battery management, and enhanced data monitoring. By analyzing Tsumkwe and Gam, this paper offers valuable lessons for mini-grid development in Sub-Saharan Africa, stressing the need for continuous evaluation and strategic improvements to achieve sustainable rural electrification.}, language = {en} } @article{MehtaEhrenwirthZoerneretal.2023, author = {Mehta, Kedar and Ehrenwirth, Mathias and Z{\"o}rner, Wilfried and Greenough, Richard}, title = {Need of energy transition at roof of the world}, volume = {2023}, pages = {101271}, journal = {Energy for Sustainable Development}, subtitle = {Correlative approach to interpret energy identity of high-altitude Central Asian communities}, number = {76}, publisher = {Elsevier}, address = {Amsterdam}, issn = {2352-4669}, doi = {https://doi.org/10.1016/j.esd.2023.101271}, year = {2023}, language = {en} }