Refine
Labor/Institute
Keywords
- Bragg-Reflektor (5) (remove)
Document Type
- Article (5) (remove)
Language
- English (5)
Reviewed
- ja (1)
This contribution quantifies the birefringence within injection-molded cyclic olefin copolymer plates and discusses its impact on the mechanical properties of the plates. It also focuses on the impact of birefringence on integrated waveguides and Bragg gratings and provides fabrication guidelines for such structures. The anisotropy in all three dimensions of the workpiece is examined by means of polarimetry and a prism coupler. It is found that the birefringence is inhomogenously distributed within the workpieces, whereas the maximum birefringence not only varies locally, but also depends on the observation direction. Overall, a maximum birefringence of 10 × 10−4 is found at the plate’s surface near the injection gate. The anisotropy then reduces exponentially towards the center of the workpiece and saturates at 1.8 × 10−4, in a depth of 0.4 mm. Thus, the birefringence strongly affects near-surface photonic structures. It is found that, depending on their orientation and the local birefringence of the substrate, waveguides and Bragg gratings fabricated with comparable parameters behave completely differently in terms of polarization-dependent optical attenuation, cross-sectional intensity distribution and Bragg reflection signal. For example, the support of the TM mode can vary between total loss and an optical attenuation of 0.9 dB × cm−1. In consequence, this study underlines the importance of quantifying the birefringent state of an injection-molded cyclic olefin copolymer workpiece if it is supposed to serve as a substrate for integrated photonic structures. The study furthermore demonstrates that birefringence effects can be omitted by burying the photonic structures deeper into the volume of the thermoplastic.
This study demonstrates and discusses a novel approach for the fabrication and rapid prototyping of monolithic photonic platforms comprising a ridge-type waveguide with integrated sensing structures. First, the bulk injection-molded cyclic olefin copolymer substrates are micromilled in order to define the physical extension of the ridge structure. Cross-sections down to 30 × 30 µm2, exhibiting a mean surface roughness of 300 nm, are achieved with this process. Subsequently, UV radiation is used to modify the ridge structure’s refractive index, which leads to the formation of an optical waveguide. By employing a phase mask, it is possible to equip the photonic platform with a Bragg grating suitable for temperature measurements with a sensitivity of −5.1 pm K-1. Furthermore, an integrated Fabry-Pérot cavity, generated during the micromilling step as well, enables refractive index measurements with sensitivities up to 1154 nm RIU-1.
This contribution demonstrates and discusses electrically tunable polymer planar Bragg gratings based on bulk cyclic olefin copolymers. A lithographic single-writing-step method and femtosecond laser reductive sintering of copper(II) oxide nanoparticles are subsequently employed in order to generate buried photonic structures and copper conducting paths on top of the polymer substrate. This way, the necessary number of process steps for fabricating a planar polymer-based electro-optical device is greatly reduced. The response of a fully electrified grating structure follows temperature changes, induced by the copper conducting path, with sensitivities up to −31 pm K−1. Dilatometric measurements show that the specimen's behavior is correlated to the situationally reduced thermal expansion of the bulk polymer substrate. In consequence, the tuning response of the photonic platform follows a second order polynomial, whereas a direct current of 30 mA, which correlates to a power consumption of 18.3 mW, leads to a local temperature increase and a residual Bragg wavelength shift of 19.6 K and −547 pm, respectively. Moreover, the outstanding flexibility of the proposed fabrication concept is underlined by demonstrating alternative conducting path geometries, whereas one of the additional designs is adapted to control the spectral width of the Bragg grating's reflection peak.
This contribution demonstrates the functionality of polymer planar Bragg grating (PPBG) sensors integrated into commercial-grade carbon fiber reinforced polymer (CFRP) components. Multiple CFRP specimens are generated by curing a stack of pre-impregnated fibers inside of a heated mechanical press, exposing the polymer sensor to a pressure of 7 bar and a temperature of 120 °C for 2 h. After integration, the sensor still exhibits a strong and evaluable signal. Subsequent flexural experiments reveal a linear response of the integrated sensor’s Bragg wavelength to the CFRP specimen’s maximum deflection. Additional findings demonstrate that the embedded PPBG can be used to detect plastic deformations of a CFRP workpiece, whereas a linear correlation of plastic deformation to the resulting Bragg signal offset is determined. A plausibility check of the obtained results is delivered by a comparison of three-point flexural experiments on bulk CFRP workpieces, without integrated sensors and additional specimens featuring external optical sensors affixed to their surface. It is found that PPBGs based on cyclic olefin copolymers are able to overcome the temperature-related limitations of traditional polymer-based optical sensors and can thus be directly integrated into commercial-grade composites during production.
Hypersensitive H2 sensor based on polymer planar Bragg gratings coated with Pt-loaded WO3-SiO2
(2020)
This letter demonstrates a novel hydrogen sensor based on a polymer planar Bragg grating coated with Pt-loaded WO3-SiO2. The reflected Bragg signal shows a distinct peak splitting correlated to substrate anisotropies originating from the injection molding process. Especially at low H2 concentrations, both sensing peaks
exhibit an outstanding response to the heat generated by the exothermic reaction between hydrogen molecules and coating. Thereby, a hydrogen volume ratio of 50 ppm
leads to a Bragg wavelength shift of -37 pm, which yields an outstandingly low detection limit of only 5 ppm H2 in air. Thus, functionalized polymer planar Bragg gratings are eminently suitable for H2 leak detection applications.