Refine
Labor/Institute
- BIOMEMS Lab (4)
Keywords
- Biosensor (2)
- Mikroelektrode (2)
- Röntgenspiegel (2)
- Röntgenteleskop (2)
- X-ray (2)
- iridium (2)
- mirror (2)
- telescope (2)
- Alginate (1)
- Array (1)
Document Type
- Article (6)
- Conference Proceeding (2)
Language
- English (8)
Reviewed
- ja (1)
Transparent poly(3,4-ethylenedioxythiophene)-based microelectrodes for extracellular recording
(2018)
It is well known that at the interface between neuronal tissue and recording electrode low electrical impedance is required. However, if simultaneous optical detection or stimulation is an issue, good optical transmittance of the electrode material is desirable as well. State-of-the-art titanium nitride electrodes provide superior low impedance compared to gold or iridium, but are nontransparent. Transparent electrode materials like the transparent conducting oxide, indium tin oxide (ITO), or graphene offer high light transmittance (>80%) but reveal relatively high impedance. In this paper, the authors propose the conducting polymer poly(3,4-ethylenedioxythiophene) with the counter ion NO−3 as the electrode material for low impedance and good optical transmittance properties. The polymer is electrochemically deposited onto ITO improving the relatively high impedance of ITO. This multilayer electrode allows not only for electrophysiological recordings of cardiomyocytes but also for monitoring of cell contraction under the microscope. Electrochemical impedance spectroscopy and action potential recordings reveal that the new transparent electrodes are a good compromise in terms of low impedance and transparency if deposition parameters are optimized.
Our drinking water contains residues of pharmaceuticals. A sub-group of these contaminants are neuro-active
substances, the antiepileptic carbamazepine being one of the most relevant. For assessment of the neurotoxicity of this
drug at a sub-therapeutic level, a cell-based sensor chip platform has been realized and characterized. For this
purpose, a microelectrode array chip was designed and processed in a clean room and optimized in terms of low
processing costs and good recording properties. For characterization of the system neuronal cells were plated on
microelectrode array chips and electrical activity was measured as a function of applied carbamazepine concentration.
We found that the relative spike rate decreased with increasing drug concentration resulted in IC50 values of around 36 μM. This value is five orders of magnitude higher than the maximal dose found in drinking water. IC50 values for
burst rate, burst duration and synchrony were slightly higher, suggesting spike rate being a more sensitive parameter to
carbamazepine.
Iridium-based layer systems are highly effective mirror coatings for space-born X-ray telescopes. During the recent years, Aschaffenburg University of Applied Sciences and its partners developed stress compensated chromium-iridium coatings for such astronomical applications, using chromium as an adhesive layer between iridium reflective layer and mirror substrate. However, there was room for improvement: To overcome the disturbing reflectivity reduction of the iridium absorption edge around 2 keV photon energy, thin overcoat layers of chromium are applied in addition now. This layer system has been analyzed by atomic force microscopy and transmission electron microscopy images. Furthermore, the reflectivity of such innovative X-ray mirrors based on chromium-iridium tri-layer coatings was recently measured at PTB's four-crystal monochromator beamline at the synchrotron radiation facility BESSY II. The experimental results, obtained for photon energies between 1.9 keV and 11 keV at two grazing incidence angles (0.6 degree and 0.9 degree) and their comparison with corresponding simulations are presented in this contribution. When compared to simulations of pure iridium coatings, a significantly higher reflectivity was achieved especially in the soft X-ray regime between 2 keV and 4 keV. Such chromium-iridium tri-layer coatings have high potential to increase the effective area for X-ray telescopes in Lobster Eye Design, for Wolter-I type X-ray optics, and for silicon pore optics as considered for the ATHENA telescope of the European Space Agency.
For space-born astronomical X-ray telescopes, iridium-based reflective layer systems are known as highly effective
mirrors coatings. During the recent years, Aschaffenburg University of Applied Sciences and the Czech Technical
University in Prague jointly developed stress compensated chromium-iridium coatings for this application. To overcome the disturbing reflectivity reduction of the iridium absorption edge around 2 keV photon energy, thin overcoat layers of chromium were applied in addition. Now a prototype of a wide-field, imaging X-ray telescope
of Lobster Eye type is assembled at the company RIGAKU. For this purpose a small series of 34 mirrors based on 100 x 50 mm semiconductor grade silicon substrates has been coated at Aschaffenburg University. The applied tri-layer system consists of a stack of 40 nm chromium, which act as adhesive layer and compensates layer stress, a 30 nm iridium thick reflective layer, and an additional overcoat layer of 6 nm chromium. This layer system
have been analysed by AFM and TEM images. The mirrors are assembled into an aluminium frame to build a 2D Lobster Eye type telescope. The designed focal length of this wide field X-ray telescope is two meter. To study the performance of the tri-layer coating system, a twin LE telescope with convenient gold coatings was manufactured also. Performance measurements of both telescopes and under same conditions are planned at the PANTER test facility at the Max-Planck Institute for Extraterrestrial Physics. First experimental results,
their comparison with theoretical simulations and the comparison between both models will be presented in this contribution.
In recent years, there has been an increasing interest in electrically conductive hydrogels for a wide range of biomedical applications, like tissue engineering or biosensors. In this study, we present a cost-effective conductive hydrogel based on alginate and graphene nanoplatelets for extrusion-based bioprinters. The hydrogel is prepared under ambient conditions avoiding high temperatures detrimental for cell culture environments. Investigation of the hydrogel revealed a conductivity of up to 7.5 S/cm, depending on the ratio of platelets. Furthermore, in vitro tests with human embyronic kidney cells - as an example cell type - showed good adhesion of the cells to the surface of the conductive hydrogel. Electrochemical measurements revealed a low electrode impedance which is desirable for the extracellular recording, but also low electrode capacitance, which is unfavorable for electrical stimulation purposes. Therefore, future experiments with the graphene nanoplatelets-based hydrogels will focus on electrodes for biosensors and extracellular recordings of neurons or cardiac myocytes.
Piezoelectrets fabricated from fluoroethylenepropylene (FEP)-foils have shown drastic increase of their piezoelectric
properties during the last decade. This led to the development of FEP-based energy harvesters, which are about to evolve
into a technology with a power-generation-capacity of milliwatt per square-centimeter at their resonance frequency. Recent
studies focus on piezoelectrets with solely negative charges, as they have a better charge stability and a better suitability for
implementation in rising technologies, like the internet of things (IOT) or portable electronics. With these developments
heading towards applications of piezoelectrets in the near future, there is an urgent need to also address the fabrication
process in terms of scalability, reproducibility and miniaturization. In this study, we firstly present a comprehensive review
of the literature for a deep insight into the research that has been done in the field of FEP-based piezoelectrets. For the first
time, we propose the employment of microsystem-technology and present a process for the fabrication of thermoformed
FEP piezoelectrets based on thermoforming SU-8 templates. Following this process, unipolar piezoelectrets were fabricated with air void dimensions in the range of 300–1000 lm in width and approx. 90 lm in height. For samples with a void
size of 1000 lm, a d33-coefficient up to 26,508 pC/N has been achieved, depending on the applied seismic mass. Finally,
the properties as energy harvester were characterized. At the best, an electrical power output of 0.51 mW was achieved for
an acceleration of 1 g with a seismic mass of 101 g. Such piezoelectrets with highly defined dimensions show good
energy output in relation to volume, with high potential for widespread applications.
This paper presents an optimized laser-bonding process for piezoelectric energy-harvesters based on thin fluorinated-ethylene-propylene (FEP) foils, using an ultra-short-pulse(USP) laser. Due to the minimized thermal stress in the material during bonding, achieved bypulse durations of few picoseconds, we created seams down to 40μm width without generatingholes in the 12.5μm thick FEP-foils. Using a galvanometer scanning system allowed for fastbonding-speed up to several centimeters per second, making the process also suitable for largestructures and areas. The achieved bond strength of the seams under influence of shearingstress was examined using tensile testing, which showed a sufficient strength of about 25 % of the maximum strength of an unbonded, single layer of FEP.
In recent years, the demand for sustainable and degradable materials and electronic devices has increased significantly.
Among a range of biodegradable polymers, poly(lactic acid) (PLA) is a good alternative to conventional petrol-based polymers because of its attractive mechanical properties and its easy processability. Recently, PLA has also been described as a promising dielectric material with piezoelectric and electret properties. We expect that PLA—after further optimization— will play an important role as a material for environmentally friendly sensors in the future, where first applications such as air filters and pressure sensors have already been proposed. However, degradation under normal ambient conditions is very slow, and an accelerated and controllable degradation process is highly desirable for any type of PLA-based sensors.
Enzymatic hydrolysis with embedded enzymes has been proposed as an approach to accelerate and control degradation. In this work, we investigate the properties of PLA in terms of dielectric and mechanical properties with a focus on its ability to store charges after the enzyme proteinase K (Trit. album) has been incorporated. Results reveal that proteinase K has a positive effect on the charge stability of solvent-cast PLA electrets after complete evaporation of the solvent. Furthermore, we observed a concentration-dependent acceleration of mass loss in a Tris-HCl buffer. A fast degradation within only one day occurred at a concentration of 6 wt% proteinase K.