Refine
Labor/Institute
Keywords
- Bragg-Reflektor (15)
- Femtosekundenlaser (8)
- Laserbearbeitung (8)
- Laserschneiden (7)
- Lumineszenzdiode (6)
- Sensor (6)
- Ultrakurzzeitlaser (5)
- Faserlaser (4)
- Kohlendioxidlaser (4)
- Wellenleiter (3)
Year of publication
Document Type
- Conference Proceeding (60) (remove)
Reviewed
- nein (6)
This contribution reviews recent advancements, current research and possible applications of polymer planar Bragg grating (PPBG) sensors with a focus on the utilization of cyclic olefin copolymer (COC) substrates. COC-PPBGs can be handled and fabricated efficiently by employing a single writing step procedure which features simultaneous generation of waveguide and Bragg grating structure within an injection molded substrate. The resulting photonic structures exhibit an attenuation as low as 1.2 dB cm-1 and a reflectivity up to 99 %. The potential of COC-PPBGs for high-temperature applications is proven by demonstrating temperature measurements up to 160 °C. Moreover, it is possible to employ single PPBGs for multidimensional stress and strain sensing or even three-dimensional shape reconstruction. Due to their excellent properties, it is feasible to integrate COC-PPBGs into commercial-grade carbon fiber reinforced polymer workpieces for structural health monitoring. Furthermore, utilization of appropriate coatings enables functionalization of PPBGs for refractive index sensing and thus biochemical applications. Beside the fabrication and characterization of COC-based PPBGs, this contribution exemplifies and reviews such applications.
Lab-on-chip systems are based on components to transport, mix, separate and analyse small volumes of different fluids. The consecutive integration of more complex functions into a single and compact chip demands on multilayer systems. As the classical production using a stacking and joining of single processed layers is elaborate and limited in terms of multilayer structures, an uprising trend to fabricate those devices is the internal, three dimensional processing of transparent substrates by using ultrashort laser pulses. In this study, we report on the generation of internal hollow architectures created by focused 514nm femtosecond laser pulses inside optical polymer bulk materials of different polymers. The three-dimensional channel layout is implemented by moving the sample using three-dimensional motorized stages, allowing arbitrary complex shaped internal channel architectures. Size and cross sectional shape of a single internal generated microchannel are determined by the intensity distribution of the focal voxel. In particular, we show a comprehensive parameter study to improve this laser process with respect to a higher processing speed and stability.
Microfluidic lab on chip systems require components to transport, mix, separate and analyse small volumes of different fluids. In this study, we report on the laser generation of internal hollow architectures created by focused 514 nm femtosecond laser pulses inside PMMA bulk material. Size and cross-sectional shape of a single internal generated microchannel are determined by the intensity distribution inside the focal voxel and can be controlled either by the numerical aperture of the focusing objective or by laser beam shaping. As both approaches are practically limited with respect to the realizable cross-sectional shapes, we present a process based on an internal hatching to expand the achievable channel cross-sections and thereby enable the possibility to create complex 3D shaped internal structures. This process is applied to create fully internal functional microfluidic elements such as mixers which are part of most polymer lab-on-chip systems.
This contribution discusses the integration of polymer planar Bragg grating sensors (PPBG) into carbon fiber reinforced polymer (CFRP) components. For the first time, it is shown that PPBGs based on cyclic olefin copolymers can be integrated into commercial-grade composites, thereby withstanding the demanding production processes. Pre-impregnated fibers are stacked and partially modified to form a sensor pocket. Afterwards, the CFRP specimen containing the optical sensor is cured in a heated mechanical press for 2 hours at a pressure of 7 bar and a temperature of 120 °C. A subsequent evalutaion of the sensor signal shows a Bragg wavelength shift of 1236 pm and a decline in signal amplitude of -2 dB. Three-point flexural tests of the cured sample reveal a linear behavior of the sensor signal towards external loads. The determined sensitivity in dependence of the CFRP specimen's maximum central deflection is -112 pm/mm, while correlation to the applied force results in a sensitivity of -5 pm/N.