Refine
Has Fulltext
- no (5)
Document Type
- Conference Proceeding (4)
- Article (1)
Is part of the Bibliography
- yes (5)
Institute
This paper presents a complete workflow for the evaluation of GaN transistors in voltage source inverters. With the associated high switching speed of transistors based on GaN, it is important to consider some critical points in the design phase as well as in the measurement setup in order to be able to utilise and verify the advantages of GaN properly. For this reason, the presented circuit board’s design focuses on a minimised power loop inductance. Simulation models, an analytical approach and measurement results with the aim of determining this inductance are compared with each other. A good compliance results between the presented methods. Additionally, the description of a test bench is given, which enables the performance of the opposition method. This setup allows the measurement of the designed H-bridge’s arising losses and the GaN-transistor’s switching behaviour. In comparison to the conventional double pulse method, this approach enables results that are more accurate for determining losses.
In industrial applications, a transformer is the interface between medium and low voltage grid. At this coupling point, disturbances may transmit to the supply grid. Hence, an influence on other electrical loads in the same supply grid may occur. Power electronic components in electric drive systems with high switching frequencies and high voltage slew rates of the switching transitions are able to excite unexpected disturbance currents through parasitic paths. According to legal regulations, the system operator is obliged to keep them in specified limits. In this paper, measurement data recorded at a medium voltage transformer in several typical grid applications with different filters are analysed to show the coupling from low to medium voltage grid and to identify advantages and disadvantages of different commonly used topologies.
According to parasitic effects, unwanted resonant circuits occur in electric applications. In power electronic systems, resonances might be excited. Modulation methods are decisive for the frequency dependent voltage excitation generated by power electronic components. In this paper a delta-sigma modulated voltage source inverter is considered with the aim of reducing common mode disturbances. Simulative and experimental results are discussed in order to state out advantages and disadvantages in comparison to a pulse width modulation. Especially significant peaks in voltage spectra can be reduced with a delta-sigma modulated inverter.
This paper presents a method of impedance analysis in power electronic systems during operation. The switching behavior of power electronic components causes harmonic excitation in a system. These harmonics in voltage and current are analyzed with a polyphase filter bank. Afterwards they are used to calculate the system’s frequency dependent impedance. The method is validated with simulations and verified by measurements of a real power converter. The results give incentive for further researches.
In this paper, a high-frequency model for three-phase coils with iron core is presented. This model also considers the ohmic behavior. The basis is a equivalent circuit for air core coils, which has been extended. For validation, a test bench consisting of a power converter, a choke and a capacitor was set up. Currents and voltages were measured and compared with the high-frequency model. In the standard equivalent circuit, the system oscillation is present. However, in the simulation with the high-frequency model and in the measurements on the test bench, the system oscillations are strongly damped.