An experimental facility is presented, which allows calibration and detailed investigation of infrared camera systems. Various blackbodies operating in the temperature range from -60 degree(s)C up to 3000 degree(s)C serve as standard radiation sources, enabling calibration of camera systems in a wide temperature and spectral range with highest accuracy. Quantitative results and precise long-term investigations, especially in detecting climatic trends, require accurate traceability to the International Temperature Scale of 1990 (ITS-90). For the used blackbodies the traceability to ITS- 90 is either realized by standard platinum resistance thermometers (in the temperature range below 962 degree(s)C) or by absolute and relative radiometry (in the temperature range above 962 degree(s)C). This traceability is fundamental for implementation of quality assurance systems and realization of different standardizations, for …
Radiator standards for accurate IR calibrations in remote sensing based on heatpipe blackbodies
(1999)
The demand of instrumentation in the field of remote sensing is increasing rapidly. For international compatibility, for reliable results and precise long-term investigation, necessary for example in the measurement of climatic trends, accurate traceability of the results to international standards or SI-units is mandatory. Additionally, interpretation of the results strongly requires a careful evaluation of the involved errors and the resulting uncertainties in order to allow for a rating of the obtained results. For that purpose quality assurance was introduced, not only for industrial fabrication, but also, and with increasing tendency, for industrial and scientific research. As an overview, the necessity and the possibilities of quality assurance in the area of remote sensing are discussed. Taking remote sensing of temperature as an example, the general approach is described. For that purpose, a description of heatpipe blackbodies …
An advanced method for the calibration of tungsten strip lamps is reviewed in detail. The method is based on measuring the ratio of the spectral radiances of two sources at different radiance temperatures TL by radiation thermometry. Instead of using the distribution temperature and the colour emissivity for the calculation of the radiance temperature, the derivative dTL/dλ in the vicinity of the effective wavelength of the detection system is applied. In a first step high-stability vacuum tungsten strip lamps are calibrated as first-order working standards with respect to fixed points of the International Temperature Scale of 1990 (ITS-90). In a subsequent step, secondary working standards are calibrated relative to these first order working standards with light of different wavelengths determined by interference filters. A detailed description of the evaluation procedure for the determination of the radiance temperature of the lamps is given and several problems encountered in operating the lamps are discussed. The standard uncertainties of the radiance temperature are below 0.2 K for the first order working standards.
The large area double-heatpipe blackbody (LABB) used for comparing thermodynamic temperatures with the International Temperature Scale of 1990 (ITS-90) at temperatures higher than 600 C is based on two sodium heat pipes. The lowest temperature at which the sodium heat pipes work properly is strongly correlated to the onset of sodium evaporation. This is expected for temperatures well above 500 C. Planning to use the LABB for extending the comparison of thermodynamic temperatures with the ITS-90 to temperatures as low as possible, we measured the isothermal behaviour of the blackbody cavity starting at heatpipe temperatures of 400 C. The temperature of the cylindrical part of the cavity was measured with a standard platinum resistance thermometer (SPRT) sensing the bottom of the cavity and up to three quarter of the cylindrical part of the cavity. The obtained temperature profiles are well explained assuming the occurrence of two superimposing effects: a real nonisothermal behaviour of the LABB for temperatures below 500 C and a cooling of the SPRT caused by radiation loss through the aperture of the cavity. Applying a Monte-Carlo simulation we calculated the emissivity of the LABB at different heatpipe temperatures below 600 C using the obtained non-isothermal temperature distribution at the cylindrical walls. It was found that even at temperatures as low as 415 C the accuracy of the LABB is sufficient for comparison of thermodynamic temperatures and the ITS-90.