TY - JOUR A1 - Hartmann, Jürgen A1 - Manara, Jochen A1 - Stark, Thomas A1 - Zipf, Matthias A1 - Arduini, Mariacarla A1 - Ebert, Hans-Peter A1 - Tutschke, Andreas A1 - Hallam, Andrew A1 - Hanspal, Jagdevinder A1 - Langley, Mark T1 - Entwicklung und Test eines langwelligen Strahlungsthermometers zur berührungslosen Temperaturmessung in Gasturbinen während des Betriebs JF - tm - Technisches Messen N2 - The aim of this work was the development of a long wavelength infrared radiation thermometer for the non-contact measurement of surface temperatures in stationary gas turbines during operation within the EU-project „Sensors Towards Advanced Monitoring and Control of Gas Turbine Engines (acronym STARGATE)“. In this work, the infrared-optical properties of the thermal barrier coatings and the combustion gases were determined at ZAE Bayern at high temperatures up to 1600 K and pressures up to 13 bar. Based on these experimental characterizations, a suitable spectral range could be identified which lies around 10 μm for the long-wavelength infrared radiation thermometer. According to these findings, a laboratory setup with suitable optical components (filters, IR-fibers, etc.) was firstly realized and verified. Subsequently, a prototype for measurements in gas turbines during operation of the turbines has … N2 - Das Ziel dieser Arbeit bestand in der Entwicklung eines langwelligen Strahlungsthermometers zur berührungslosen Messung von Oberflächentemperaturen in stationären Gasturbinen während des Betriebs der Turbinen innerhalb des EU-geförderten Projektes „Sensors Towards Advanced Monitoring and Control of Gas Turbine Engines (Acronym STARGATE)“. Im Rahmen der Arbeit wurden die infrarot-optischen Eigenschaften der Wärmedämmschichten und der vorhandenen Brenngase am ZAE Bayern bei hohen Temperaturen bis 1600 K und Drücken bis 13 bar bestimmt. Mit Hilfe dieser experimentellen Charakterisierungen konnte ein geeigneter Spektralbereich um 10 μm für das langwellige Strahlungsthermometer identifiziert werden. Entsprechend dieser Erkenntnisse wurde zunächst ein Laboraufbau mit geeigneten optischen Bauteilen (Filter, IR-Wellenleiter, etc.) realisiert und verifiziert. Anschließend wurde ein Prototyp für Messungen in Gasturbinen während des Betriebs der Turbinen entwickelt und in einem Turbinenteststand der Firma Siemens AG in Berlin erfolgreich getestet. Abschließend wurde eine Unsicherheitsanalyse durchgeführt, die eine erweiterte Messunsicherheit der gemessenen Temperaturen von etwa ± 30 K ergab. T2 - Development and test of a long wavelength infrared radiation thermometer for non-contact temperature measurements in gas turbines during operation KW - Berührungslose Temperaturmessung KW - Strahlungsthermometrie KW - Wärmedämmschicht KW - Gasturbine KW - Emissionsgrad KW - Infrarot-Strahlung KW - Non-contact temperature measurement KW - radiation thermometry KW - thermal barrier coating KW - gas turbine KW - emissivity KW - infrared radiation Y1 - 2017 U6 - https://doi.org/https://doi.org/10.1515/teme-2017-0077 VL - 85 IS - 1 SP - 28 EP - 39 PB - Oldenbourg Wissenschaftsverlag CY - Berlin/Boston ER - TY - JOUR A1 - Jürgen, Hartmann A1 - Arduini, Mariacarla A1 - Manara, Jochen A1 - Stark, Thomas A1 - Ebert, Hans-Peter T1 - Development and Evaluation of an Improved Apparatus for Measuring the Emissivity at High Temperatures JF - Sensors N2 - An improved apparatus for measuring the spectral directional emissivity in the wavelength range between 1 µm and 20 µm at temperatures up to 2400 K is presented in this paper. As a heating unit an inductor is used to warm up the specimen, as well as the blackbody reference to the specified temperatures. The heating unit is placed in a double-walled vacuum vessel. A defined temperature, as well as a homogenous temperature distribution of the whole surrounding is ensured by a heat transfer fluid flowing through the gap of the double-walled vessel. Additionally, the surrounding is coated with a high-emitting paint and serves as blackbody-like surrounding to ensure defined boundary conditions. For measuring the spectral directional emissivity at different emission angles, a movable mirror is installed in front of the specimen, which can be adjusted by a rotatable arrangement guiding the emitted radiation into the attached FTIR-spectrometer. The setup of the emissivity measurement apparatus (EMMA) and the measurement procedure are introduced, and the derived measurement results are presented. For evaluating the apparatus, measurements were performed on different materials. The determined emissivities agree well with values published in literature within the derived relative uncertainties below 4% for most wavelengths. KW - emissivity KW - reflectivity KW - infrared radiation KW - high temperature KW - Temperatur KW - Emissivität Y1 - 2021 UR - https://www.mdpi.com/1424-8220/21/18/6252 U6 - https://doi.org/10.3390/s21186252 SN - 1424-8220 VL - 21 IS - 18 ER -