<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>5632</id>
    <completedYear/>
    <publishedYear>2024</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue>7</issue>
    <volume>10</volume>
    <type>article</type>
    <publisherName>Elsevier BV</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Pixelwise high-temperature calibration for in-situ temperature measuring in powder bed fusion of metal with laser beam</title>
    <abstract language="eng">High-temperature calibration methods in additive manufacturing involve the use of advanced techniques to accurately measure and control the temperature of the build material during the additive manufacturing process. Infrared cameras, blackbody radiation sources and non-linear optimization algorithms are used to correlate the temperature of the material with its emitted thermal radiation. This is essential for ensuring the quality and repeatability of the final product. This paper presents the calibration procedure of an imaging system for in-situ measurement of absolute temperatures and temperature gradients during powder bed fusion of metal with laser beam (PBF-LB/M) in the temperature range of 500 K–1500 K. It describes the design of the optical setup to meet specific requirements in this application area as well as the procedure for accounting the various factors influencing the temperature measurement. These include camera-specific effects such as varying spectral sensitivities of the individual pixels of the sensor as well as influences of the exposure time and the exposed sensor area. Furthermore, influences caused by the complex optical path, such as inhomogeneous transmission properties of the galvanometer scanner as well as angle-dependent transmission properties of the f-theta lens were considered. A two-step fitting algorithm based on Planck's law of radiation was applied to best represent the correlation. With the presented procedure the calibrated thermography system provides the ability to measure absolute temperatures under real process conditions with high accuracy.</abstract>
    <parentTitle language="eng">Heliyon</parentTitle>
    <identifier type="issn">2405-8440</identifier>
    <identifier type="doi">10.1016/j.heliyon.2024.e28989</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,16]],"date-time":"2024-05-16T00:30:15Z","timestamp":1715819415091},"reference-count":26,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,28]],"date-time":"2024-03-28T00:00:00Z","timestamp":1711584000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100021711","name":"Bayerisches Staatsministerium f\u00fcr Wissenschaft und Kunst","doi-asserted-by":"publisher"}],"content-domain":{"domain":["cell.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Heliyon"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1016\/j.heliyon.2024.e28989","type":"journal-article","created":{"date-parts":[[2024,4,2]],"date-time":"2024-04-02T16:39:17Z","timestamp":1712075957000},"page":"e28989","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Pixelwise high-temperature calibration for in-situ temperature measuring in powder bed fusion of metal with laser beam"],"prefix":"10.1016","volume":"10","author":[{"ORCID":"http:\/\/orcid.org\/0009-0003-5295-6709","authenticated-orcid":false,"given":"Dennis","family":"H\u00f6fflin","sequence":"first","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0009-0002-3191-9135","authenticated-orcid":false,"given":"Christian","family":"Sauer","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-1447-7331","authenticated-orcid":false,"given":"Andreas","family":"Schiffler","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-5319-6874","authenticated-orcid":false,"given":"Jochen","family":"Manara","sequence":"additional","affiliation":[]},{"ORCID":"http:\/\/orcid.org\/0000-0002-9645-5434","authenticated-orcid":false,"given":"J\u00fcrgen","family":"Hartmann","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.heliyon.2024.e28989_bib1","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.1177\/0954410014568797","article-title":"The present and future of additive manufacturing in the aerospace sector: a review of important aspects","volume":"229","author":"Uriondo","year":"2015","journal-title":"Proc. Inst. Mech. Eng. G J. Aerosp. Eng."},{"key":"10.1016\/j.heliyon.2024.e28989_bib2","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.cobme.2017.05.006","article-title":"Biomedical applications of additive manufacturing: present and future","volume":"2","author":"Singh","year":"2017","journal-title":"Current Opinion in Biomedical Engineering"},{"key":"10.1016\/j.heliyon.2024.e28989_bib3","first-page":"1","article-title":"Additive manufacturing in automobile industry","volume":"7","author":"Sarvankar","year":"2019","journal-title":"Int. J. Res. Aeronaut. Mech. Eng."},{"key":"10.1016\/j.heliyon.2024.e28989_bib4","doi-asserted-by":"crossref","first-page":"112001","DOI":"10.1088\/1361-6501\/ac0b6b","article-title":"In-situ measurement and monitoring methods for metal powder bed fusion: an updated review","volume":"32","author":"Grasso","year":"2021","journal-title":"Meas. Sci. Technol."},{"key":"10.1016\/j.heliyon.2024.e28989_bib5","doi-asserted-by":"crossref","first-page":"5943","DOI":"10.3390\/s22165943","article-title":"Process monitoring using synchronized path infrared thermography in PBF-LB\/M","volume":"22","author":"H\u00f6fflin","year":"2022","journal-title":"Sensors"},{"key":"10.1016\/j.heliyon.2024.e28989_bib6","doi-asserted-by":"crossref","first-page":"2789","DOI":"10.1007\/s00170-020-06441-0","article-title":"On-line melt pool temperature control in L-PBF additive manufacturing","volume":"112","author":"Rezaeifar","year":"2021","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"10.1016\/j.heliyon.2024.e28989_bib7","doi-asserted-by":"crossref","first-page":"2887","DOI":"10.1007\/s00170-019-04195-y","article-title":"Closed loop control of melt pool width in robotized laser powder\u2013directed energy deposition process","volume":"104","author":"Akbari","year":"2019","journal-title":"Int. J. Adv. Des. Manuf. Technol."},{"key":"10.1016\/j.heliyon.2024.e28989_bib8","doi-asserted-by":"crossref","first-page":"2247","DOI":"10.1007\/s00170-022-08929-3","article-title":"In situ monitoring plasma arc additive manufacturing process with a fully convolutional network","volume":"120","author":"Zhang","year":"2022","journal-title":"Int. J. Adv. Des. Manuf. Technol."},{"key":"10.1016\/j.heliyon.2024.e28989_bib9","doi-asserted-by":"crossref","first-page":"46","DOI":"10.3390\/s22010046","article-title":"Opto-thermal investigation of additively manufactured steel samples as a function of the Hatch distance","volume":"22","author":"H\u00f6fflin","year":"2022","journal-title":"Sensors"},{"key":"10.1016\/j.heliyon.2024.e28989_bib10","first-page":"600","article-title":"In-situ characterization and quantification of melt pool variation under constant input energy density in laser powder bed fusion additive manufacturing process","volume":"28","author":"Guo","year":"2019","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.heliyon.2024.e28989_bib11","first-page":"548","article-title":"Melt pool temperature and cooling rates in laser powder bed fusion","volume":"22","author":"Hooper","year":"2018","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.heliyon.2024.e28989_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.6028\/jres.126.013","article-title":"Measurement uncertainty of surface temperature distributions for laser powder bed fusion processes","volume":"126","author":"Deisenroth","year":"2021","journal-title":"Journal of Research of the National Institute of Standards and Technology"},{"key":"10.1016\/j.heliyon.2024.e28989_bib13","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s40192-020-00169-1","article-title":"Measurements of melt pool geometry and cooling rates of individual laser traces on IN625 bare plates","volume":"9","author":"Lane","year":"2020","journal-title":"Integr Mater Manuf Innov."},{"key":"10.1016\/j.heliyon.2024.e28989_bib14","series-title":"Sim-AM 2019: II International Conference on Simulation for Additive Manufacturing","first-page":"246","article-title":"In-situ thermogr phic monitoring of the laser metal deposition process","author":"Scheuschner","year":"2019"},{"key":"10.1016\/j.heliyon.2024.e28989_bib15","doi-asserted-by":"crossref","first-page":"1546","DOI":"10.3390\/met10111546","article-title":"Experimental determination of the emissivity of powder layers and bulk material in laser powder bed fusion using infrared thermography and thermocouples","volume":"10","author":"Mohr","year":"2020","journal-title":"Metals"},{"key":"10.1016\/j.heliyon.2024.e28989_bib16","series-title":"Thermosense: Thermal Infrared Applications XXXVIII","first-page":"42","article-title":"Calibrating IR cameras for in-situ temperature measurement during the electron beam melt processing of Inconel 718 and Ti-Al6-V4","author":"Dinwiddie","year":"2016"},{"key":"10.1016\/j.heliyon.2024.e28989_bib17","doi-asserted-by":"crossref","first-page":"2639","DOI":"10.1364\/AO.10.002639","article-title":"Evaluation of the emissivity of a cavity source by reflection measurements","volume":"10","author":"Bauer","year":"1971","journal-title":"Appl. Opt."},{"key":"10.1016\/j.heliyon.2024.e28989_bib18","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1063\/1.1721341","article-title":"Spectral emissivities of graphite and carbon","volume":"24","author":"Thorn","year":"1953","journal-title":"J. Appl. Phys."},{"key":"10.1016\/j.heliyon.2024.e28989_bib19","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.physrep.2008.09.001","article-title":"High-temperature measurement techniques for the application in photometry, radiometry and thermometry","volume":"469","author":"Hartmann","year":"2009","journal-title":"Phys. Rep."},{"key":"10.1016\/j.heliyon.2024.e28989_bib20","series-title":"Strahlungstemperaturmessung, Handbuch Der Technischen Temperaturmessung","first-page":"1161","author":"Hartmann","year":"2014"},{"key":"10.1016\/j.heliyon.2024.e28989_bib21","first-page":"1526","article-title":"Is Levenberg-Marquardt the most efficient optimization algorithm for implementing bundle adjustment?","volume":"vol. 1","author":"Lourakis","year":"2005"},{"key":"10.1016\/j.heliyon.2024.e28989_bib22","doi-asserted-by":"crossref","first-page":"6252","DOI":"10.3390\/s21186252","article-title":"Development and evaluation of an improved apparatus for measuring the emissivity at high temperatures","volume":"21","author":"Arduini","year":"2021","journal-title":"Sensors"},{"key":"10.1016\/j.heliyon.2024.e28989_bib23","series-title":"VDI\/VDE 5585 - Temperature Measurements with Thermographic Cameras Calibration","year":"2021"},{"key":"10.1016\/j.heliyon.2024.e28989_bib24","series-title":"Infrared Thermography: Errors and Uncertainties","author":"Minkina","year":"2009"},{"key":"10.1016\/j.heliyon.2024.e28989_bib25","series-title":"Theory and Practice of Radiation Thermometry","author":"DeWitt","year":"1991"},{"key":"10.1016\/j.heliyon.2024.e28989_bib26","article-title":"In-situ sensing, process monitoring and machine control in Laser Powder Bed Fusion: a review","volume":"45","author":"McCann","year":"2021","journal-title":"Addit. Manuf."}],"container-title":["Heliyon"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024050205?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2405844024050205?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,5,15]],"date-time":"2024-05-15T10:27:10Z","timestamp":1715768830000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2405844024050205"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["S2405844024050205"],"URL":"http:\/\/dx.doi.org\/10.1016\/j.heliyon.2024.e28989","relation":{},"ISSN":["2405-8440"],"issn-type":[{"value":"2405-8440","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Pixelwise high-temperature calibration for in-situ temperature measuring in powder bed fusion of metal with laser beam","name":"articletitle","label":"Article Title"},{"value":"Heliyon","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e28989","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"e28989"}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorIdentifierOrcid_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorIdentifierOrcid_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorIdentifierOrcid_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorIdentifierOrcid_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorIdentifierOrcid_5,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,Issue,Volume,CompletedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <author>Dennis Höfflin</author>
    <author>Christian Sauer</author>
    <author>Andreas Schiffler</author>
    <author>Jochen Manara</author>
    <author>Jürgen Hartmann</author>
    <collection role="institutes" number="fm">Fakultät Maschinenbau</collection>
    <collection role="institutes" number="idee">Institut Digital Engineering (IDEE)</collection>
    <collection role="oa-colour" number="">Gefördert (Gold)</collection>
  </doc>
</export-example>
