<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>1115</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpart</type>
    <publisherName>VDE</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Erfassung transienter elektrischer Potentialverteilungen in thermisch hoch belasteten Gleichspannungsdurchführungen</title>
    <abstract language="deu">Mit Hilfe kapazitiver Steuerung können Durchführungen hochspannungsführende Leiter durch geerdete Wände in Gebäuden oder Geräten führen. Bei zeitveränderlichen Belastungen (Stoß-, Wechselspannungen) wird die gewünschte Potentialaufteilung durch die Kapazitäten zwischen den leitfähigen Steuerbelägen erzwungen. Bei Gleichspannung ergibt sich eine resistive Steuerung, die bei homogener Leitfähigkeit des Isolierkörpers eine prinzipiell gleichartige Potentialaufteilung ergibt. Durchführungen sind jedoch thermisch hoch belastete Betriebsmittel, in denen starke Temperaturgradienten und in ihrer Folge starke Leitfähigkeitsgradienten entstehen, die zu einer erheblichen Verschiebung der Potentialverteilung führen können [1]. Für Design und Diagnose ist das Verständnis dieser bisher nur theoretisch erfassbaren Vorgänge von großer Bedeutung. Deshalb wurden für experimentelle Untersuchungen zwei identische Durchführungskörper hergestellt, die mit Temperaturfühlern für thermische Messungen bzw. mit Anzapfungen für die Erfassung von elektrischen Potentialen ausgerüstet wurden. Die identische Beheizung beider Leiterrohre erlaubt es, eine Korrelation gemessener thermischer und elektrischer Profile und Transienten herzustellen. Für rückwirkungsfreie Messung der Gleichspannungspotentiale wurde ein Rotationsvoltmeter benutzt. Die Untersuchungen bestätigen das theoretisch erwartete thermisch-elektrische Verhalten und sie zeigen, dass erhebliche transiente und stationäre elektrische Belastungen auftreten können, die im Zusammenhang mit thermischen Transienten und Belastungen gesehen werden müssen. Sie sind beim Design in Rechnung zu stellen und sie zeigen, dass die bei dielektrischen Diagnosemessungen erfassten Materialkenngrößen wichtige Aussagen über den elektrischen Belastungszustand der Durchführung liefern können.</abstract>
    <parentTitle language="deu">ETG-Fachbericht 144</parentTitle>
    <subTitle language="deu">ETG-Fachtagung Diagnostik Elektrischer Betriebsmittel</subTitle>
    <identifier type="url">https://www.vde-verlag.de/proceedings-de/453648016.html</identifier>
    <author>Andreas Küchler</author>
    <author>Andreas Reumann</author>
    <author>Isabell Wirth</author>
    <author>Achim Langens</author>
    <author>Frank Berger</author>
    <collection role="institutes" number="fe">Fakultät Elektrotechnik</collection>
    <collection role="institutes" number="fm">Fakultät Maschinenbau</collection>
    <collection role="Autoren" number="küchler">Andreas Küchler</collection>
  </doc>
  <doc>
    <id>1116</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace>Osijek, Croatia</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Parameter influences on HVDC transformer insulation and its link to conduction processes</title>
    <parentTitle language="eng">32nd International Conference “Science in Practice”</parentTitle>
    <author>Andreas Küchler</author>
    <author>F. Schober</author>
    <author>A. Krieg</author>
    <author>M. Liebschner</author>
    <author>Frank Berger</author>
    <collection role="institutes" number="fe">Fakultät Elektrotechnik</collection>
    <collection role="Autoren" number="küchler">Andreas Küchler</collection>
  </doc>
  <doc>
    <id>1117</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>276</pageFirst>
    <pageLast>280</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace>Philadelphia, Pennsylvania, USA</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Interaction of Pressboard with Impregnating Fluids in HVDC Insulation Systems</title>
    <parentTitle language="eng">IEEE Electrical Insulation Conference</parentTitle>
    <author>Andreas Küchler</author>
    <author>F. Schober</author>
    <author>W. Exner</author>
    <author>Ch. Krause</author>
    <author>M. Liebschner</author>
    <author>Frank Berger</author>
    <collection role="institutes" number="fe">Fakultät Elektrotechnik</collection>
    <collection role="Autoren" number="küchler">Andreas Küchler</collection>
  </doc>
  <doc>
    <id>1114</id>
    <completedYear/>
    <publishedYear>2014</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>bookpart</type>
    <publisherName>VDE</publisherName>
    <publisherPlace>Berlin</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Leitfähigkeit von Pressspan als diagnostische Kenngröße für HGÜ-Betriebsmittel</title>
    <parentTitle language="deu">ETG-Fachbericht 144</parentTitle>
    <subTitle language="deu">ETG-Fachtagung Diagnostik Elektrischer Betriebsmittel</subTitle>
    <author>Andreas Küchler</author>
    <author>F. Schober</author>
    <author>S. Harrer</author>
    <author>T. Wolfinger</author>
    <author>Ch. Krause</author>
    <author>W. Exner</author>
    <author>Frank Berger</author>
    <collection role="institutes" number="fe">Fakultät Elektrotechnik</collection>
    <collection role="Autoren" number="küchler">Andreas Küchler</collection>
  </doc>