@inproceedings{HartmannTaubertFriedrichetal., author = {Hartmann, J{\"u}rgen and Taubert, Dieter Richard and Friedrich, R. and Sperfeld, P. and Hollandt, J{\"o}rg}, title = {Long-Term Stability of the Spectral Responsivity of Filter Radiometers at the PTB}, series = {Proceedings of Tempmeko 2004}, booktitle = {Proceedings of Tempmeko 2004}, editor = {Zvizdic, D.}, address = {Zagrep}, pages = {977 -- 982}, language = {en} } @inproceedings{HartmannMcEvoyMachinetal., author = {Hartmann, J{\"u}rgen and McEvoy, H.C. and Machin, Graham and Friedrich, R. and Hollandt, J{\"o}rg}, title = {Comparison of the New NPL Primary Standard Ag Fixed-Point Blackbody Source with the Primary Standard Fixed Point of PTB}, series = {AIP Conference Proceedings (684)}, booktitle = {AIP Conference Proceedings (684)}, publisher = {American Institute of Physics}, isbn = {0-7354-0153-5}, pages = {909 -- 914}, abstract = {Above the freezing point of silver (961.78 °C), the International Temperature Scale of 1990 is defined in terms of Planck's radiation law. The scale is maintained and disseminated using a validated and linear pyrometer in conjunction with a blackbody reference source at either the Ag, Au (1064.18 °C) or Cu (1084.62 °C) freezing point. In order to realize the scale with the highest precision high quality, well-characterised, reproducible fixed-point blackbody sources are required. Such sources have been maintained at NPL for a number of years, but it was felt that improvements to the design would be beneficial. A new Ag point blackbody source has therefore been constructed. The new design will improve the quality and reproducibility of the melting and freezing plateaux and reduce errors due to the 'out-of-focus' size-of-source effect which is difficult to measure and to eliminate. Full details of the design of the new …}, language = {en} } @inproceedings{HartmannFriedrichSchilleretal., author = {Hartmann, J{\"u}rgen and Friedrich, R. and Schiller, S. and Fischer, J.}, title = {Non-isothermal temperature distribution and resulting emissivity corrections for the high temperature blackbody BB3200}, series = {Proc. 8th International Symposium on Temperature and Thermal Measurements in Industry and Science - Proceedings of Tempmeko 2001}, booktitle = {Proc. 8th International Symposium on Temperature and Thermal Measurements in Industry and Science - Proceedings of Tempmeko 2001}, editor = {Fellmuth, B. and Seidel, J. and Scholze, G.}, publisher = {VDI Verlag}, address = {Berlin}, pages = {227 -- 232}, language = {en} } @inproceedings{HartmannMcEvoyMachinetal., author = {Hartmann, J{\"u}rgen and McEvoy, H.C. and Machin, Graham and Friedrich, R. and Hollandt, J{\"o}rg}, title = {Comparison of the new NPL primary standard Ag fixed-point blackbody source with the primary standard fixed-point of PTB}, address = {Chicago (USA)}, language = {en} } @misc{HartmannTaubertFriedrichetal., author = {Hartmann, J{\"u}rgen and Taubert, Dieter Richard and Friedrich, R. and Hollandt, J{\"o}rg}, title = {Improved calibration of the spectral responsivity of interference filter radiometers in the visible and near infrared spectral range at PTB}, address = {Gaithersburg (USA)}, language = {en} } @article{HartmannHollandtFriedrichetal., author = {Hartmann, J{\"u}rgen and Hollandt, J{\"o}rg and Friedrich, R. and Gutschwager, B. and Taubert, Dieter Richard}, title = {High-Accuracy Radiation Thermometry at the National Metrology Institute of Germany}, series = {High Temperatures - High Pressures}, volume = {35/36}, journal = {High Temperatures - High Pressures}, number = {4}, pages = {379 -- 415}, language = {en} } @article{HartmannFriedrichTaubertetal., author = {Hartmann, J{\"u}rgen and Friedrich, R. and Taubert, Dieter Richard and Hollandt, J{\"o}rg}, title = {Improved calibration of the spectral responsivity of interference filter radiometers in the visible and near infrared spectral range at PTB}, series = {Metrologia}, journal = {Metrologia}, number = {40}, pages = {35 -- 38}, language = {en} }