TY - THES A1 - Taheruzzaman, Muhammad T1 - Design, modelling, and planning of renewable energy integrated microgrid for rural electrification in Bangladesh N2 - The Electric power crisis is one of the major problems in Bangladesh, the gap between demand and generation is increasing day by day. Moreover, most of the power plants are gas based which will be phased out in future. An alternate electric supply is an essential part for electrifying the developing countries, in this context an innovative approach of rural electrification including DC microgrid, mini-grid and nanogrid would be technically and economically feasible. The thesis draws also attention on the development of technology which enables community owned power system to emerge in the rural areas based on distributed SHS and demand of that community. Firstly, the electric status and renewable potential in Bangladesh are studied and considered those data into the software based simulation to analysis the technical feasibility to implement DC microgrid by Homer pro tools. The distributed RES (Renewable Energy sources) considered solar PV and biomass. The booming of a large number of individual SHS (Solar Home System) in Bangladesh, bottom-up energy sharing concept would have studied to configure the optimal design of microgrid system and different configuration including grid connected and DC and AC system studied. Secondly, The PV module is highly dependent on cell temperature and solar irradiance, the ambient temperature, and solar irradiance mathematical equation have been considered to model and simulate in MATLAB/SIMULINK based environment. Similarly charge controller, battery operation, and performance analysis with respect to the PV model. In the distributed energy sources are mainly SHS including large size and regular also model and simulate in MATLAB/SIMULINK software. For instance, the thesis mainly focuses on an optimal design, planning, sizing of DC hybrid microgrid, the SHS, and biomass-based power system with the goal of maximizing the efficiency and reliability. Homer Pro tool used in the work for design an optimal configuration and sizing for technical feasibility. Finally, a model of DC microgrid compresses with micro sources like SHS systems, µ-CHP, the household loads model in MATLAB/SIMULINK. Decentralized SHS control strategies (droop control) and operation also design and model in MATLAB/SIMULINK environment, where DC – DC converter needs to couple SHS and DC microgrid. KW - Biomass KW - Microgrid KW - Solar home system KW - Rural electrification KW - SIMULINK KW - Biomasse KW - Energiemanagement KW - Fotovoltaikanlage KW - Elektrifizierung KW - Ländlicher Raum Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-39884 ER - TY - THES A1 - Bonkarev, Maxim T1 - Concept analysis for High-Voltage Direct-Current circuit breakers for application in a network of HVDC transmission T1 - Konzeptanalyse für Hochspannungsgleichstrom-Übertragungsschalter für die Anwendung in einem HGÜ Übertragungsnetz N2 - For several decades HVDC technology was used primarily for point-to-point bulk power transmission. Although multiterminal HVDC systems are very few in number, it is expected that multiple HVDC links may be interconnected into HVDC transmission grid. Since every meshed grid requires reliable protection solution, an HVDC circuit breaker must be developed and introduced. This thesis focuses on the performance evaluation of different HVDC circuit breaker concepts. The performance evaluation study is carried out by means of numerical simulations. The obtained quantitative results describe capabilities and limitations of different HVDC circuit breaker concepts as well as the reaction of HVDC network on switching operations. Different converter protection measures and in particular application of fault current limiter were considered, too. Based on the research findings, a number of recommendations for HVDC circuit breaker development are given and suggestions for further research activities are presented. N2 - Seit mehreren Jahrzehnten wurde die HGÜ-Technologie hauptsächlich für die Punkt-zu-Punkt Übertragung der großen Strommengen verwendet. Obwohl multiterminale HGÜ-Systeme nicht zahlreich vertreten sind, wird erwartet, dass mehrere HGÜ-Leitungen in HGÜ-Netz verbunden werden können. Da jedes vermaschte Stromnetz zuverlässige Schutzlösung erfordert, muss ein HGÜ-Leistungsschalter entwickelt und eingesetzt werden. Diese Doktorarbeit konzentriert sich auf die Leistungsbewertung der verschiedenen HGÜ-Leistungsschalterkonzepte. Die Leistungsbewertungsstudie wird durch numerische Simulationen durchgeführt. Die erhaltenen quantitativen Ergebnisse beschreiben Möglichkeiten und Grenzen der verschiedenen HGÜ-Leistungsschalterkonzepte sowie die Gegenwirkung des HGÜ-Netzwerkes auf Schaltvorgänge. Verschiedene Umrichter-Schutzmaßnahmen und insbesondere Anwendung der Strombegrenzer wurden auch untersucht. Auf Grundlage der Forschungsergebnisse werden eine Reihe von Empfehlungen für die Entwicklung des HGÜ-Leistungsschalters gegeben und Anregungen für weitere Forschungsaktivitäten vorgestellt. KW - Multi-terminal HVDC KW - HVDC circuit breaker KW - Fault protection methods KW - Network response KW - Simulation-based performance evaluation KW - Multiterminale HGÜ KW - HGÜ-Leistungsschalter KW - Fehlerschutzmethoden KW - Netzwerkreaktion KW - Simulationsbasierte Leistungsbewertung KW - Hochspannungsgleichstromübertragung KW - Vermaschtes Netz KW - Netzschutz KW - Leistungsschalter KW - Fehlererkennung Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-35459 ER - TY - THES A1 - Dewi, Sari T1 - Repowering public utility grid by integrating hydro, PV and wind into the grid to supply electricity in Palu (Indonesia) T1 - Erneuerung des öffentlichen Stromversorgungsnetzes durch Integration von Wasserkraft, PV und Wind in das Netz zur Stromversorgung in Palu (Indonesien) N2 - The use of renewable energy sources, either off-grid or on-grid to supply electricity, has been done by developed countries since many years ago. Developing countries, for example Indonesia especially east part of Indonesia have recently started this way whereas renewable energy potential for example hydro, PV and wind are abundantly available. The lack of research and data is one of the obstacles to precede the use of renewable energy in this area, meanwhile this area has electricity shortages problem that occurred quite often. Combined hydro, PV, wind, coal and diesel generators will solve electricity shortages problem in Palu (Indonesia). Integration of Hydro, PV and wind into PALAPAS utility grid will decrease levelized cost of energy from US$ 0.145 per kWh to US$ 0.133 per kWh. Sensitivity analysis against fluctuating fuel cost (from US$ 0.4 per litre to US$ 1.6 per litre) will increase levelized cost of energy before integrating renewable energy into the grid from US$ 0.145 per kWh to US$ 0.455 per kWh and will increase levelized cost of energy after integrating RE into the grid from US$ 0.133 per kWh to US$ 0.403 per kWh. Repowering grid with integrating hydro, PV and wind will increase power quality especially by using configuration based on homer results. Buses voltage and buses frequency showed better result before, during and after some faults based on Homer simulation results. Voltage spectrum and sinusoidal waveform voltage are showing less distortion after integrating hydro, PV and wind into the grid even with no distortion based on Homer results. N2 - Die Nutzung erneuerbarer Energiequellen, die entweder netzunabhängig oder netzfern Strom liefern, ist seit vielen Jahren Aufgabe der Industrieländer. Entwicklungsländer wie Indonesien, insbesondere der östliche Teil, haben kürzlich damit begonnen. Mangelnde Forschung und Datenmangel sind eines der Hindernisse, die der Nutzung erneuerbarer Energien in diesem Bereich entgegenstehen. In diesem Gebiet treten häufig Probleme mit Stromengpässen auf. Die Kombination von Wasserkraft-, PV-, Wind-, Kohle- und Dieselgeneratoren wird das Problem der Stromknappheit in Palu (Indonesien) lösen. Durch die Integration von Wasserkraft, PV und Wind in das Versorgungsnetz von PALAPAS werden die gestaffelten Energiekosten von 0,145 US-Dollar pro kWh auf 0,133 US-Dollar pro kWh gesenkt. Sensitivitätsanalysen bei schwankenden Brennstoffkosten (von 0,4 US-Dollar pro Liter auf 1,6 US-Dollar pro Liter) erhöhen die Energiekosten vor der Integration erneuerbarer Energien von 0,145 US-Dollar pro kWh auf 0,455 US-Dollar pro kWh und erhöhen die Energiekosten nach der Integration von RE in das Stromnetz von 0,133 US-Dollar pro kWh auf 0,403 US-Dollar pro kWh. Das Repowering-Grid mit integrierter Wasserkraft-, PV- und Windenergie wird die Stromqualität erhöhen, insbesondere durch die Konfiguration auf Grund von Homer-Ergebnissen. Die Busspannung und die Busfrequenz zeigten ein besseres Ergebnis vor, während und nachdem einige Fehler auf der Grundlage von Homer-Ergebnissen passierten. Das Spannungsspektrum und die sinusförmige Wellenformspannung zeigen weniger Verzerrung, nachdem Wasserkraft, PV und Wind in das Netz integriert wurden, selbst wenn keine Verzerrungen aufgrund von Homer-Ergebnissen auftraten. KW - Shortage KW - Repowering KW - Grid KW - Integration KW - Energy KW - Engpass KW - Erneuerung KW - Netz KW - Integration KW - Energie KW - Palu, Indonesien KW - Erneuerbare Energien KW - Energieversorgungsnetz KW - Elektrizitätseinspeisung Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-45472 ER - TY - THES A1 - Schmoger, Christin T1 - Sicherheitsbetrachtungen im Fall von stromstarken Erdfehlern in NOSPE-Netzen und bei Netzkopplung T1 - Safety assessments in the case of high-current earth faults in networks with low-impedance neutral point treatment and with network coupling N2 - Der von der Energiewende-bedingte Verteilnetzausbau mit Kabelstrecken beeinflusst den Umgang mit der Sternpunktbehandlung. Neben klassischen Umstellungsmaßnahmen sind neue Lösungen zur Kopplung von Netzen mit unterschiedlicher Sternpunktpunkterdung zu diskutieren. Schwerpunkt stellt jeweils die Auslegung von Erdungsanlagen in Kombination mit einem geeigneten Schutzkonzept zur Einhaltung der Personensicherheit dar. Auf Basis der DIN EN 50522 ist ein mögliches personengefährdendes Potential zu bewerten, welches aus der Stromverteilung an der Fehlerstelle resultiert. In der Praxis wird dabei rechnerisch die zulässige Erdungsimpedanz über den relevanten Teilstrom (dargestellt über den Reduktionsfaktor) und dem, aus dem Schutzkonzept resultierenden, Grenzwert für die Berührungsspannung vorgegeben und messtechnisch geprüft. Vorrangig in Mittelspannungsnetzen mit niederohmiger Sternpunkterdung bestehen Unsicherheiten in der korrekten Interpretation der Norm respektive der Wahl und Beurteilung geeigneter Parameter. Die Dissertation konzentriert sich auf die Schwerpunkte Bestimmung des Reduktionsfaktors in einer inhomogenen, offen betriebenen Ringstruktur von Mittelspannungsnetzen, sowie Diskussion möglicher Modelle und der Wirkungsweise heutiger Messverfahren von Erdungsimpedanzen. Aufbauend auf theoretischen Modell-Analysen wurde eine Methodik zur Auswertung beider Parameter u. a. durch Aufnahme einer Stromverteilung in einem Erdkurzschlussversuch entwickelt und erstmals in einer Netzgruppe durchgeführt. Die Herausforderung bestand darin, Lösungen zum eindeutigen messtechnischen Nachweis beider Parameter infolge von Überlagerungseffekten zu entwickeln. Mithilfe der Versuchsergebnisse konnten bestehende Berechnungs- und Messverfahren sowie unterschiedlichen Modelle zur Interpretation der Erdungsimpedanz bewertet und Handlungsempfehlungen abgeleitet werden. Reduktionsfaktor und Erdungsimpedanz erfahren verschiedene Interpretationen in der Praxis. Daher widmete sich die Dissertation der Analyse des Modells der DIN EN 50522 und schlägt aufgrund der Herausforderungen in der Praxis eine Erweiterung zur eindeutigen Definition vor. Erstmalig konnten anhand des Versuchs die Modellansätze von Berechnungsverfahren für den Reduktionsfaktor geprüft und bestätigt werden. Am Beispiel des VPE-Kabels konnte mit einem Sicherheitsaufschlag ein Planungswert vorgeschlagen werden. Auf Basis des Versuchs und der heutigen Messverfahren wurde diskutiert, dass die Erdungsimpedanz infolge der unterschiedlichen Einbeziehung von Kettenleitern verschiedene Werte annehmen kann. Aufgrund des Zusammenhangs mit dem Reduktionsfaktor resultieren für die Bewertung der Berührungsspannung Kombinationspaare, die nach dem Modell der DIN EN 50522 oder Modifizierungen in der Berechnung ausgelegt und mittels klassischer Messung bewertet werden können. Die Dissertation liefert damit einen Diskussionsbeitrag, wie sich die Auslegung von Erdungsanlagen durch geeignete Verfahren weiterentwickeln kann. N2 - The grid expansions caused by the German Renewable Energies Act (EEG) have an impact on the neutral point treatment of grids due to the addition of power cables instead of overhead lines. Besides conversion measures new solutions for the coupling of networks with different neutral earthing have to be discussed. The focus of the dimensioning of grids with high fault currents is on the rating of the grounding systems in combination with an appropriate selective protection concept to meet personal safety requirements. The concept of calculation and measurement of the grounding impedance is based on the DIN EN 50522. Especially in medium-voltage networks, uncertainties occur within the planning process regarding the appropriate choice of parameters according to the right interpretation of the German standard DIN EN 50522. Hence, this thesis focusses on the following core areas Development of computational procedures for the determination of reduction factors in inhomogeneous and open ring systems of a medium-voltage network; Discussion of models and present measurement standard methods for earthing impedances. To answer the questions, a methodology for the evaluation of data gathered in a short-circuit to earth trial was developed and actually tested in a real existing network for the first time in the German-speaking countries. Especially in the trial an explicit separation of both parameters is essential for a proper interpretation of the results. The Thesis concentrates on the overlapping effect and elaborates possible solution concepts for the parameters metrological evidence. The results of the trial have been compared with calculation methods, measurement methods and existing models of the earthing impedances. The scientific discoveries of this Thesis have been compared with the requirements of the German standard DIN EN 50522 to derive recommendations for the practical application. Reduction factor and earthing impedance are interpreted differently. For this reason, the dissertation analysis the overhead line model of the DIN EN 50522 and proposes to an enhanced model to define discussed practical challenges explicit. Theoretical and practical analyses of the reduction factor further qualify already developed calculation methods and suggest corresponding safety margins for VPE-cables. The comparison of the trial and standard methods indicates that different earthing impedances, caused by the chain conductor, are possible. The interpretation of the earthing impedance has an immediate impact on the reduction factor determination. Within the trial, different combinations of reduction factors with earthing impedances were investigated for the valuation of safety requirements. By means of the evaluation of the short-circuit to earth trials within this Thesis an approach is shown, how the dimensioning of grounding systems with consideration of appropriate measuring and calculation procedures can be developed further. KW - Erdungsanlagen KW - Reduktionsfaktor KW - Erdungsimpedanz KW - Sternpunkterdung KW - DIN EN 50522 KW - Grounding system KW - Reduction factor KW - Earthing impedance KW - Neutral point treatment KW - EN 50522 KW - Mittelspannungsnetz KW - Erdschluss KW - Sternpunkterdung KW - Wechselstromwiderstand KW - Impedanzmessung Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-51131 ER - TY - THES A1 - Dhara, Madhavi T1 - Wirkung von Kabelschirmungskonzepten auf abgestrahlte Magnetfelder von elektrischen Antriebssträngen in Elektro- und Hybridfahrzeugen T1 - Influence of cable shielding concepts on radiated magnetic fields from electric drive trains in pure electric and hybrid vehicles N2 - Jede elektrische, elektronische Komponente für Kraftfahrzeugsanwendungen muss auf Komponentenebene und nach der Montage im Fahrzeug die elektrischen, magnetischen und elektromagnetischen Emissionsanforderungen gemäß Normen erfüllen. Die Entwicklung von Konzepten der elektromagnetischen Verträglichkeit für ein elektrisches Kraftfahrzeug erfordert ein gründliches Verständnis der elektromagnetischen Kopplungsmechanismen des Hochvoltsystems. An einen Elektroantrieb werden vielfältige Anforderungen gestellt. Daraus ergibt sich eine eingeschränkte Handlungsfreiheit zum Erreichen der elektromagnetischen Verträglichkeit. Daher ist es im Entwicklungszyklus nötig, Ressourcen mit Kenntnis der elektromagnetischen Verträglichkeit frühzeitig zielgereicht einsetzen zu können. Hierbei gilt es Designparameter frühzeitig festzulegen und bereits dabei eine Ergebnisbewertung vornehmen zu können. Die Wellenlängen der dominanten Spektren elektromagnetischer Störungen von Spannungsquellenpulswechselrichtern im Vergleich zu den geometrischen Abmaßen eines normal großen Fahrzeugs fallen in den Nahfeldbereich. Dies ermöglicht einen quasistationären Ansatz, bei dem das elektrische Feld und das Magnetfeld getrennt untersucht und analysiert werden können. Der Schwerpunkt dieser Arbeit liegt auf der gestrahlten Magnetfeldkopplung in einem Kraftfahrzeug mit einem Elektroantrieb. Üblicherweise erfordert ein Elektroantrieb für seinen Betrieb funktionale Ströme höherer Größenordnung. Das pulsweitenmodulierte Spannungsschalten der leistungselektronischen Wandler, z.B. bei Pulswechselrichter und Gleichstrom (DC)/DC Wandler, verursacht zusätzlich zu den funktionalen Strömen auch parasitäre Ströme. Diese werden durch Spannungsänderungen am Ausgang der Leistungselektronik erzeugt, die die verteilten Kapazitäten z.B. Statorwicklung zu Rahmenkapazität der elektrische Maschine, anregen. Diese Ströme führen zu Magnetfeldemissionen, an die strenge Anforderungen auf Fahrzeugebene gestellt werden. Abschirmungen werden systematisch zur Verringerung der abgestrahlten Emissionen bei elektrischen Antriebsanwendungen in Kraftfahrzeugen eingesetzt, so auch für die Hochvoltkabel. Die relativ geringen Mengen einer nicht idealen Kabelschirmung sind aufgrund des hohen Grades an abgestrahlten Emissionen von Bedeutung. Folglich sind die Schirm- und Masseschleifenströme, d.h. die Schirmwirkung, entscheidend für die Magnetfelder. Neben diesen Stromverteilungen sind die Magnetfelder wesentlich von der Geometrie der Hochvoltkabelführung und dem Frequenzbereich abhängig. In dieser Arbeit werden drei Arten von Schirmungskonzepten für Hochvoltkabel mittels analytischer Modellierung betrachtet. Die drei Schirmungskonzepte sind einzeln geschirmte Kabel in koaxialer Ausführung, mehradrige geschirmte Kabel in Summenschirmausführung und ungeschirmte Kabel mit parallelem Massedraht als Schirm. Die erstellten analytischen Modelle werden genutzt, um die gestrahlten Magnetfeldemissionen vorherzusagen. Ein Vergleich zur Bestätigung der Anwendbarkeit der analytischen Modelle für ein Elektroantriebssytem wird vorgestellt. Die Wirkung der verschiedenen Schirmungskonzepte für das Kraftfahrzeug wird dargelegt. N2 - Every electronic, electrical component for automotive applications has to comply with the electric, magnetic and electromagnetic emission requirements according to the norms and standards during component test and after its assembly in the vehicle. The development of electromagnetic compatibility concepts for electric vehicles require a thorough understanding of electromagnetic coupling mechanisms of the high volatage system. Limited freedom of modifications in vehicle electric drive necessitates the optimal utilization of available resources which further requires adequate recognition and assessment of electromagnetic compatibility related design parameters. The wavelengths of dominant electromagnetic interferences from voltage source inverter compared to geometrical dimension of a regularly sized vehicle will fall into near field region. It enables a quasi-steady approach in which the electric and magnetic fields can be investigated and analysed seperately. The focus of this work is laid on the radiated magnetic field coupling in an automotive electric drive. Usually automotive electric drive involves higher order functional currents for its operation. Pulse width modulated voltage switching of the power electronic converters like inverter and DC/DC converter causes parasitic currents additional to the functional ones. Parasitic currents are generated due to unbalanced voltages at the output of the power electronics which excite the distributed capacitances for e.g. stator winding to frame capacitance of the motor. These currents result in magnetic field emissions which face stringent requirements on vehicle level. Magnetic fields depend on the current strength, geometry, coupling on antennas and wires or other electronic devices. Shields are systematically used to reduce radiated emissions in automotive electric drive applications, so for the high voltage cables. The relatively small quantities of a non ideal cable shield are of importance due to the high level of radiated emissions. As a consequence, the shield and ground loop currents i.e. shielding effectiveness are decisive for magnetic fields. Along with these current distributions, the magnetic fields are significantly dependent on the geometry of high voltage cable routes and the characteristics in frequency domain. In this work, three types of shielding strategies for high voltage cables i.e. individually shielded cables, multiconductor shielded cables and unshielded cables with parallel ground wire which functions as shield are considered for analytical modelling to predict radiated magnetic field emissions. A comaparitive study on their applicabilty in the automotive electrical drive system is presented. KW - Magnetfeld KW - HV Kabelschirmungskonzepte KW - Gleichtaktströme KW - Gegentaktströme KW - Übertragungsfunktionen KW - Magnetic field KW - HV cable shielding concepts KW - Common mode currents KW - Differential mode currents KW - Transfer functions KW - Elektrofahrzeug KW - Hybridfahrzeug KW - Triebstrang KW - Kabel KW - Elektromagnetische Verträglichkeit KW - Magnetische Abschirmung Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-55008 ER - TY - THES A1 - Jende, Enrico T1 - Ein Beitrag zur modellgestützten Planung und zum Betrieb sektorenübergreifender Energiespeicher mit Fokus auf die Strom- und Wärmeversorgung in Microgrids T1 - A contribution to model-based planning and operation of cross-sectoral energy storage systems with focus on power and heat supply in Microgrids N2 - Zur Einhaltung der Dekarbonisierungsziele und Bewältigung der Herausforderungen bei der ganzheitlichen Transformation des Energiesystems im Kontext der politisch geforderten Energiewende, ist zunehmend der Begriff Sektorenkopplung zu verzeichnen. Eine wesentliche Rolle nimmt dabei die auf den Begriff Power-to-X (P2X) zusammengefasste Elektrifizierung der Sektoren Gas, Wärme, Kälte und Mobilität ein. P2X-Energiewandler und die damit einhergehende Nutzung Erneuerbarer Energien (EE), z.B. aus Photovoltaik (PV) und Wind, sind aufgrund der volatilen Stromerzeugung der EE-Anlagen als dargebotsabhängige Energiewandlung zu verstehen. Aus diesem Grund werden P2X-Energiewandler mit sektoralen Energiespeichern und flexiblen bedarfsgerechten Energiewandlern hin zu sektorenübergreifenden Energiespeichern aggregiert. Diese sind nicht nur in der Lage den Herausforderungen eines zunehmend aus EE bestehenden Energieversorgungssystems (EVS) entgegenzuwirken, sondern einen Beitrag zur sektorenübergreifenden Energiebedarfsdeckung und Dekarbonisierung zu leisten. In diesem Zusammenhang ist in den vergangenen Jahren auf dem Campus der Brandenburgischen Technischen Universität Cottbus-Senftenberg (BTU) eine Forschungs- und Demonstrationsanlage entstanden, welche sektorale und sektorenübergreifende Energiespeicher topologisch lokal aggregiert und hinsichtlich der Netzbetriebsführung verknüpft. Dieser dezentrale Anlagenverbund bietet eine herausragende Möglichkeit, einen sektorenübergreifenden Betrieb der dezentralen EVS auf lokaler Ebene zu untersuchen. Als Forschungsgegenstand und Teilsystem der Forschungs- und Demonstrationsanlage gilt im Folgenden der sektorenübergreifende Energiespeicher bestehend aus den Technologien der Kraft-Wärme-Kopplung, Power-to-Heat und einem thermischen Energiespeicher. Dieser Anlagenverbund wird innerhalb der Systemgrenzen eines Microgrid unter größtmöglicher Nutzung erneuerbarer Energien am Beispiel der PV untersucht. Ein Simulationsmodell erweitert diesen Forschungsgegenstand und zielt auf modellgestützte Untersuchungen zur Planung und zum Betrieb des sektorenübergreifenden Energiespeichers, insbesondere zur stromnetzdienlichen Systemintegration. Die Ergebnisse der Untersuchungen werden im Folgenden dargestellt und gelten als Beitrag zur Systemintegration von sektorenübergreifenden Energiespeichern in die lokale dezentrale Energieversorgung. N2 - To comply with the decarbonisation objectives and to tackle the challenges of the holistic transformation of the energy system in the context of the politically demanded energy transition, is increasingly being used the term sector coupling. The electrification of the gas, heat, cooling and mobility sectors, which is based on the term Power-to-X (P2X), plays a key role here. P2X energy converters and the associated use of renewable energies (EE), e.g. from photovoltaic (PV) and wind, are as a supply-dependent energy conversion to understand in to the volatile power generation of renewable energy plants. For this reason P2X energy converters with sectoral energy storage systems and flexible demand-oriented energy converters are aggregated into cross-sectoral energy storage systems. These are not only able to contract the challenges of an increasing renewable energy supply system (EVS), but also to make a contribute to cross-sectoral energy coverage and decarbonisation. In this context, a research and demonstration facility was built in recent years on the campus of the Brandenburg Technical University Cottbus-Senftenberg (BTU), which aggregates sectoral and cross-sectoral energy storage topologically local and links it regard in to grid operation management. This decentralized network of facilities provides an excellent opportunity to investigate cross-sectoral operation of decentralized EVS in a local level. In the following the research subject and subsystem of the research and demonstration plant is named the cross-sector energy storage consisting of the technologies of combined heat and power, power-to-heat and a thermal energy storage. This system composite is investigated within the system limits of a microgrid with the greatest possibility use of renewable energies using e.g. PV. A simulation model extends this research thesis and aims at a model-based investigations for the planning and operation of the cross-sector energy storage, in particular for grid-compliened system integration. The results of the investigations are presented below and are considered to contribute to the system integration of cross-sectoral energy storage into the local distributed energy supply system. KW - Microgrid KW - Sektorenkopplung KW - Dezentrale Energieversorgung KW - Sektorenübergreifender Energiespeicher KW - Sector coupling KW - Decentralized energy supply KW - Cross-sectoral energy storage KW - Microgrid KW - Microgrid KW - Elektrizitätsversorgungsnetz KW - Dezentrale Energieversorgung KW - Dezentrale Wärmeversorgung Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-52906 ER - TY - THES A1 - Engelbrecht, Daniel T1 - Untersuchung der Potentiale und Anforderungen an ein Wirkleistungsmanagement im Verteilnetz mit hohem Anteil von dezentralen Erzeugungsanlagen T1 - Study of the potentials and requirements for an Active Power Management in the distribution system with high propotion of regenerative generation units N2 - In der Dissertation werden neue Potentiale und Anforderungen sowie neue Verfahren und Methoden zur Bereitstellung von Systemdienstleistungen erarbeitet. Der Fokus wird dabei auf das Wirkleistungsmanagement im Verteilnetz gelegt. Bei einer zunehmenden Durchdringung von Erneuerbaren Energien steigt der gegenseitige Einfluss mit den technischen Systemen im Netzbetrieb und bestehenden sowie zukünftigen Märkten. In der Arbeit werden organisatorische und technische Lösungen entwickelt, welche eine sichere Bereitstellung von Regelleistung sowie eine Unterstützung durch den Verteilnetzbetreiber für ein systemdienliches Engpassmanagement des Übertragungsnetzbetreibers ermöglichen. Anhand eines 110-kV-Modellnetzes werden die technischen Lösungen aufgezeigt und bewertet. Dabei zeigt sich, dass eine erweiterte Betriebsplanung im Verteilnetz notwendig wird. Mögliche Konflikte können im Vorfeld durch eine Netzzustandsbewertung und Informationsübermittlung gelöst werden. Weiterhin können Anforderungen des ÜNB zur Unterstützung zum Redispatch im Rahmen einer Vortagesplanung integriert werden. Zur Realisierung der Prozesse und somit Erfüllung der neuen Anforderungen sind zum Teil technische Ände-rungen in den Systemen der Netzführung sowie organisatorische und rechtliche Anpassungen in der Handhabung des Engpassmanagements notwendig. Hierzu werden in der vorliegenden Arbeit konkrete Empfehlungen ausgesprochen. N2 - This thesis presents new potentials and requirements as well as procedures and methods for provision of ancillary services in an electrical system. The focus of the thesis is the Active Power Management in the distribution system. With increasing penetration of renewable energies, the mutual influence of technical systems in the system operation and existing and future markets increases. In this thesis, organizational and technical solutions are developed which enable a secure supply of control power and support from the distribution system operator for a congestion management of the transmission system. Elaborated technical solutions are presented and evaluated using the 110-kV network model. The results of the network simulation show that an extended operational planning is necessary in the operation of the distribution system. Possible can be solved in a forecast process with a network status evaluation and provision of information. Furthermore, requirements of the TSO regarding a support of the Redispatch can be integrated into a forecast process of the system operation of the distribution system. For the realization of the process and to fulfill the new requirements, some technical changes are required in the network operation systems as well as organizational and legal adaptations for the application of the congestions management. In this regard, concrete recommendations are made in this thesis. KW - Wirkleistungsmanagement KW - Verteilnetz KW - Erneuerbare Energien KW - Regelleistung KW - Redispatch KW - Active power management KW - Distribution system KW - Control power KW - Redispatch KW - Renewable energy KW - Lastverteilung KW - Erneuerbare Energien KW - Wirkleistung KW - Verteilungsnetz Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:co1-opus4-43479 ER -