To avoid a catastrophic failure of insulation in high-voltage (HV) applications, a monitoring of partial discharges (PD) is necessary. Fluorescently labelled polymer optical fibres (F-POF) offer an electrically passive method for PD detection in HV facilities. F-POF could be embedded into HV cable insulation material, which are usually made of silicone rubber. Due to the difficult accessibility of HV cable accessories, a self-healing silicone rubber, based on incorporated capsules, with prolonged service life after PD detection represents an attractive material design for HV electrical insulation.
Im Arbeitskreis von Herrn Prof. Dr. Menzel (TU Braunschweig) wurde in Sievershausen ein Vortrag zum Thema „Self-healing and mechanically reinforced silicone rubber by the use of multifuctional capsules“ gehalten. Der Vortrag beginnt mit einer kurzen Motivation und einem Überblick über selbstheilende Materialien. Daraufhin werden die Ergebnisse zur Entwicklung eines selbstheilenden Silikonelastomers auf Basis von Kapseln, bestehend aus einem PDMS Kern und einer POS Hülle, dargestellt. Es folgt die Analytik, die auf DLS, TGA, UV/Vis und Fluoreszenzspektroskopie sowie SEM beruht. Der Vortrag endet mit einem Ausblick über zukünftige Arbeiten auf dem Gebiet.
To avoid a catastrophic failure of insulation in high-voltage (HV) applications, a monitoring of partial discharges (PDs) is necessary. Fluorescently labelled polymer optical fibers (F-POF) offer an electrically passive method for PD detection in HV facilities. F-POFs could be embedded in HV cable accessories, which are usually made of silicone rubber. Herein they detect the light emitted by the PD and convert it into an electrical signal that can be monitored. Due to the difficult accessibility of HV cable accessories, a self-healing silicone rubber with prolonged service life after PD detection represents an attractive material design for HV accessories. With this contribution, we would like to present and discuss the possibilities of combining self-healing materials with POF-based sensors for PD detection in HV applications.