The corrosion of stainless steel components is a problem of global scale, economically as well as in regards to the safety of industrial equipment and facilities. With microorganisms involved (microbial influenced corrosion, MIC), the problem becomes more complex. Iron reducing bacteria (IRB) for example accelerate the corrosion of iron based materials like stainless steel via the reduction of iron oxides in the passive layer. When co-cultivated with iron oxidizing bacteria, IRBs can induce deep, heterogeneously distributed pits on stainless steel surfaces. The analysis of localized corrosion – or pitting corrosion – is of great relevance since it can lead to unpredictable material failure. In general, macroscopic electrochemical methods are not capable of providing information about the spatial heterogeneity of a sample and thus need to be complemented by multi-electrode based techniques or scanning electrochemical methods.
The aim of this work is to develop methods for the analysis of localized corrosion, on stainless steel surfaces induced by IRB biofilms. The greatest challenge is to address the complexity of two heterogeneous systems at the metal/biofilm interface. First there is the variation in the passive layer composition and microstructure. Secondly, the microbial biofilm with its heterogeneous tree-dimensional structure resulting in local differential aeration cells and electrochemical parameters. To be able to differentiate between individual effects, artificial biofilms mimicking the physical properties of a natural biofilm are used in this study as model systems. This artificial biofilm is applied on a multi-electrode probe to identify local anodic sites during exposure experiments. The detailed analysis of active sites by means of scanning electrochemical microscopy (SECM) allows the investigation of local properties within the biofilm and its immediate vicinity.
The presented analytical approach delivers promising results in clarifying how localized corrosion of stainless steels develops chronologically and spatially in the presence of IRBs. Furthermore, our results on model systems provide the basis for the application of the methodology for the investigation of natural or multi-species biofilms in the future.
Presentation of the MIC-project (Microbially Induced Corrosion) within the focus area Materials of the BAM. Strategies, developments and innovations in the area of analytical tools, surface modifications, polymer stability and biofilm-enhanced deteriorations of materials in the context of microbially induced corrosion processes.
Microbiologically Influenced Corrosion (MIC) is a phenomenon that is increasingly becoming a problem
for the society. MIC describes the negative effects a material can experience due to the presence of
microorganisms. In Europe, several research groups/ other industrial stakeholders are already dealing with
MIC. Unfortunately, the discussions are fragmented and the exchange of information is limited. A true
transdisciplinary approach is hardly ever experienced, although this would be logical for this
material/biology related challenge.
USA, Canada and Australia have strong networks, and develop methods, prevention measures and
standards, which Europe is forced to use, since nothing similar exists for a network and combined
knowledge to design them according to european standards. This makes Europe extremely dependent and,
in some cases, the potential measures or standards cannot been used because the suggested solutions
are prohibited by European laws (e.g. use of biocides).
Therefore, it is important to initiate a new European MIC-network. Europe needs to combine the efforts as
experts in different fields and develop prevention measures according to the European rules, in close
cooperation with industry and plant operators and owners of critical infrastructure. This COST Action will
provide the necessary interaction and communication, knowledge sharing, training of personnel and of
researchers of different disciplines. This will bring Europe to a leading role in this process, bringing ideas on
an equal level with other nations, considering the values which are important for Europe and attitudes (e.g.environmental protection) and representing greater protection for people, property and the environment.
The main aim and objective of the Action is to , in the context of MIC-research/control, encourage a
fluent/synergistic collaboration/communication, closing the gap between materials scientists, engineers,
microbiologists, chemists and integrity managers to encourage sufficient interaction between academia and
industry. This Action will create a common MIC-Network, including the important stakeholders.
Microbiologically induced corrosion due to bacterial biofilms causes several problems in industrial systems, technical applications and in medicine. Prior to the formation of a biofilm on a substrate, planktonic cells attach on the surface. Hence, the properties of the surface play a key role in biofilm formation and are of great importance for the development of strategies to prevent bacterial attachment and biofilm formation.
This project aims at clarifying to which extent surface micro-/nanostructuring and chemical functionalization affects bacterial attachment and whether a synergistic combination of the two can be used to control bacterial adhesion. To answer these questions, model surfaces with regular patterns of 5-10 micrometers in size have been prepared, which provide distinct zones differing in terms of their chemistry or nano-roughness. This was achieved by micro contact printing of self-assembled monolayers with different functional groups and deposition of patterned ZnO nanorod arrays for studying the effect of surface chemistry and morphology, respectively. Typical contrasts studied were combinations of positively/negatively charged, hydrophobic/hydrophilic or flat/rough.
The attachment behavior of bacteria on tailored surfaces were studied in a flow chamber as a function of time. The strain Pseudomonas fluorescens SBW25 was chosen as a model organism. DNA-intercalating dyes such as Syto9 have a high affinity to adsorb on ZnO nanorods. To overcome this limitation a genetic modification was performed by introducing a gene which expresses a green fluorescent protein in P. fluorescens SBW25 enabling the quantitative evaluation of the flow chamber studies by means of fluorescence microscopy. Further analysis of the attachment behavior was performed by means of scanning electron microscopy.
The presentation will summarize the results of our systematic study on the role of individual parameters on bacterial attachment and highlight synergistic combinations, showing an inhibition or enhancing effect. As the investigations with model substrates enable a precise control of the surface parameters, this approach can be applied to different microorganisms and material systems to achieve a correlative description of bacterial adhesion on solid surfaces.