Sonstiges
Filtern
Erscheinungsjahr
Dokumenttyp
- Sonstiges (379) (entfernen)
Sprache
- Englisch (203)
- Deutsch (167)
- Mehrsprachig (8)
- Italienisch (1)
Schlagworte
- Corrosion (16)
- Korrosion (14)
- Gefahrgutunfälle (9)
- Unfallstatistik (9)
- Wassergefährdende Stoffe (9)
- Boden (8)
- Eignungsprüfung (8)
- MKW (8)
- Archaeometry (7)
- Brückenbeläge (7)
- Coating (7)
- Gesamtcyanid (7)
- PAK (7)
- Spurenelemente (7)
- Antibodies (6)
- Corona (6)
- Digitalisierung (6)
- Nanoparticles (6)
- Beton (5)
- Cultural heritage (5)
- ELISA (5)
- MALDI-TOF-MS (5)
- NEXAFS (5)
- Nano (5)
- PAH (5)
- Proficiency testing (5)
- Soil (5)
- TPH (5)
- Trace elements (5)
- Antibody (4)
- Antikörper (4)
- Asphaltbauweise (4)
- COVID-19 (4)
- FTIR (4)
- Nanomaterial (4)
- Nanoparticle (4)
- Peptide (4)
- Potentialfeldmessung (4)
- Qualitätsinfrastruktur (4)
- Stahl (4)
- Standardisation (4)
- Testing (4)
- Total cyanide (4)
- Traceability (4)
- Zerstörungsfreie Prüfung (4)
- Asphaltbauweisen (3)
- Bioconjugation (3)
- Concrete (3)
- Eigenspannungen (3)
- Electron microscopy (3)
- Elektrochemie (3)
- Fahrbahnübergänge (3)
- Hochfester Stahl (3)
- Imaging (3)
- Keramik (3)
- Korrosionsschutz (3)
- Legierung (3)
- Linker (3)
- MAG-Schweißen (3)
- Metrology (3)
- Monitoring (3)
- Nanomaterials (3)
- OECD (3)
- Organic materials (3)
- PmB Schweißbahn (3)
- Polymer (3)
- Protein A (3)
- Protein G (3)
- Qualitätsmanagement (3)
- Qualitätssicherung (3)
- Reference materials (3)
- SARS-CoV-2 (3)
- SAXS (3)
- SDS-PAGE (3)
- Sicherheitstechnische Kenngrößen (3)
- Stahlbeton (3)
- Steel (3)
- Sustainability (3)
- Synchrotron (3)
- Synchrotron infrared radiation (3)
- Tabellenwerk (3)
- Technische Anforderungen (3)
- Ultraschall (3)
- Werkstoffprüfung (3)
- XPS (3)
- AAAA (2)
- ABID (2)
- AFM (2)
- Additive Fertigung (2)
- Affinity (2)
- Affinity chromatography (2)
- Alloys (2)
- Baustoffe (2)
- Bauwesen (2)
- Beschaffenheitsanforderung (2)
- Betonstahl (2)
- Biofilms (2)
- Bundesoberbehörden (2)
- Ceramic (2)
- Copper (2)
- Crosslinker (2)
- DICONDE (2)
- Dauerhaftigkeit (2)
- Druckbehälterverordnung (2)
- Druckgasbehälterverordnung (2)
- Dynamische Lichtstreuung (2)
- E. coli (2)
- EDS (2)
- Edelstahl Rostfrei (2)
- Elastomer (2)
- Electrochemistry (2)
- Elektrolytwiderstand (2)
- Ellipsometrie (2)
- Entzündlichkeit (2)
- Environmental pollution (2)
- Explosionsbereiche (2)
- Explosive Eigenschaft (2)
- Failure (2)
- Fenster (2)
- Fingerprint (2)
- Fluoreszenz (2)
- Forschungsstrategie (2)
- GAeF (2)
- Gasflasche (2)
- Gasgemische (2)
- Gefahrstoff (2)
- Glas (2)
- Haftfestigkeit (2)
- Herceptin (2)
- Hydrogen (2)
- IgG (2)
- Internal standards (2)
- Interoperability (2)
- Kaltrisssicherheit (2)
- Klebfestigkeit (2)
- Konformitätsbewertung (2)
- Konformitätsbewertungsstellen (2)
- Künstliche Intelligenz (2)
- Labor (2)
- Laser ablation ICP-MS (2)
- Lining (2)
- Magnesium (2)
- Magnetische Maßverkörperungen (2)
- Materials (2)
- NDT (2)
- Nachhaltigkeit (2)
- Nanomaterialien (2)
- Nanopartikel (2)
- Nanotubes (2)
- Nitrieren (2)
- OBOC library (2)
- Oberflächenanalytik (2)
- Particle size distribution (2)
- Partikel (2)
- Peptide mass fingerprinting (2)
- Physik (2)
- Plasma (2)
- Properties (2)
- Protein A cys (2)
- Prozessanalytik (2)
- Prüfbericht (2)
- Prüfung (2)
- Purification (2)
- RBD (2)
- RFA (2)
- Recycling (2)
- Reproducibility (2)
- Resilienz (2)
- Restaurierung (2)
- Roadmap (2)
- Röntgenfluoreszenzanalyse (2)
- SEM/EDX (2)
- Safety (2)
- Schweißen (2)
- Sensoren (2)
- Sensors (2)
- Separatormaterial (2)
- Sequencing (2)
- Silberoxid-Elektrode (2)
- Spike-Protein (2)
- Standard (2)
- Supernatant (2)
- Synchrotronstrahlung (2)
- Tensile strength (2)
- Terahertzsysteme (2)
- Test guideline (2)
- Thermodynamik (2)
- Ultrasonic testing (2)
- Virus (2)
- Werkstoffe (2)
- Wärmebehandlung (2)
- X-ray fluorescence analysis (2)
- XRF (2)
- Zertifizierung (2)
- ZfP (2)
- Zink (2)
- Zulassung (2)
- wiederbefüllbar (2)
- 1,3-Butadiendiepoxid (1)
- 3D (1)
- 3D Druck von Beton (1)
- 3D-Metal-Printing (1)
- A Greek palimpsest (1)
- AAA (1)
- ACE2 (1)
- ACE2-Rezeptor (1)
- ACEnano (1)
- ADC (1)
- AI tool (1)
- AKR (1)
- AOX (1)
- Abfallverbrennung (1)
- Abhilfemaßnahmen (1)
- Abschlussbauwerke (1)
- Absorbtion (1)
- Acidic cleavage (1)
- Additive manufacturing (1)
- Adhesion (1)
- AdvanceBio Peptide Map (1)
- Aerogels (1)
- Aerosol (1)
- Aerosole (1)
- Aerosolforschung (1)
- Affinity extraction (1)
- Affinitätschromatographie (1)
- Affinitätskonstante (1)
- Air-coupled ultrasound (1)
- Akkreditierung (1)
- Albrecht Dürer (1)
- Albumin (1)
- Algen (1)
- Alkali-Kieselsäure-Reaktion (1)
- Alkylierung (1)
- Aluminium (1)
- Aluminiumoxid (1)
- Ameisensäure (1)
- Amino acid analysis (1)
- Amperometrie (1)
- Analyse (1)
- Analytical centrifugation (1)
- Analytical methods (1)
- Analytical services (1)
- Anisotropie (1)
- Antibody ID (1)
- Antibody drug conjugate (1)
- Antibody identification (1)
- Antibody immobilization (1)
- Antibody light chain (1)
- Antibody subclass (1)
- Antiquity (1)
- Aqueous Solutions (1)
- Arbeit (1)
- Archäometrie (1)
- Aromatic amino acid analysis (1)
- Aromatic amino acid analysis aaaa (1)
- Aromatische Aminosäureanalytik (1)
- Aromatische Aminosäuren (1)
- Artificial intelligence (1)
- Atmospheric Corrosion (1)
- Atmosphärische Korrosion (1)
- Au-nanocubes (1)
- Ausgleichsfeuchte (1)
- Auslagerungsversuche (1)
- Autonomer Messroboter (1)
- BCA (1)
- BNP (1)
- BOS (1)
- BSA (1)
- Base damage (1)
- Base loss (1)
- Basics (1)
- Batteries (1)
- Bau- und Abbruchabfälle (1)
- Bauartprüfung (1)
- Bauschuttaufbereitung (1)
- Berührungsloser Ultraschall (1)
- Beschichtung (1)
- Betonbrechsand (1)
- Betonfahrbahndecke (1)
- Betonherstellung (1)
- Betriebsfestigkeit (1)
- Bewehrung (1)
- Bimetallkorrosion (1)
- Bio-Imaging (1)
- Bio-electrochemical (1)
- Biofilm (1)
- Biofuel (1)
- Bioregenerative ceramics (1)
- Biorezeptivität (1)
- Biosensor (1)
- Bioseparation (1)
- Biozidanalytik (1)
- Boehmite (1)
- Bohrlochsonde (1)
- Bonding analysis (1)
- Border surveillance (1)
- Borosilicate glass (1)
- Bradford-Assay (1)
- Brandschutz (1)
- Brandschutzmaßnahmen (1)
- Brass (1)
- Brennbare Flüssigkeiten (1)
- Brennbare Gase (1)
- Bridge (1)
- Bronzezeit (1)
- Building Material (1)
- Byzantine manuscript (1)
- CCMV (1)
- CCS (1)
- CO2-Corrosion (1)
- COVID (1)
- Calculation method (1)
- Calibration (1)
- Cancer (1)
- Cancer therapy (1)
- Carbamazepine (1)
- Carbon hard coating (1)
- Carrier (1)
- Cartilage (1)
- Catalogue of services (1)
- Catena-X (1)
- Cathodic protection (1)
- Cell studies (1)
- Cement technologies (1)
- Certificate (1)
- Ceruloplasmin (1)
- Characterization (1)
- Charakterisierung (1)
- Chemical imaging analysis (1)
- Chemie (1)
- Chemischer Angriff (1)
- Chip (1)
- Chloridinduzierte Korrosion (1)
- Chlorinated volatile organic compounds (VOC) (1)
- Chloropren (1)
- Chrom (1)
- Chrom(VI) (1)
- Chromatographie (1)
- Chromium(VI) (1)
- Circular Economy (1)
- Circular economy (1)
- Cispaltin (1)
- Cladding (1)
- Classification stem (1)
- Click chemistry (1)
- Clones (1)
- Cmos (1)
- Coatings (1)
- Collision and reaction cells (1)
- Column regeneration (1)
- Commercially pure iron (1)
- Communication (1)
- Compact spectrometers (1)
- Competition (1)
- Competitive Immunoassay (1)
- Composites (1)
- Computed Tomography (1)
- Computertomographie (1)
- Concrete and screed (1)
- Concrete technologies (1)
- Confiscation (1)
- Conservation (1)
- Contaminated sites (1)
- Copper alloy (1)
- Copper-catalyzed (1)
- Coronavirus (1)
- Corrosion in maritime environment (1)
- Corrosion protection (1)
- Corrosivity (1)
- Cost (1)
- Coupler systems (1)
- Covalent conjugation (1)
- Covid (1)
- Crossreactivity (1)
- Customs (1)
- Cyclisierung (1)
- DCC (1)
- DECHEMA (1)
- DEI (1)
- DFT (1)
- DIN (1)
- DLS (1)
- DM1 (1)
- DNA (1)
- DNA radiation damage (1)
- DPP (1)
- Damage cases (1)
- Data Spaces (1)
- Data book (1)
- Data fusion (1)
- Data in brief (1)
- Data science (1)
- Data storage (1)
- Database (1)
- Datenmanagement (1)
- Datenräume (1)
- Datenspeicherung (1)
- Datenwissenschaft (1)
- Datenökosystem (1)
- Degradation (1)
- Dehnfugen (1)
- Delamination (1)
- Delamination depth (1)
- Delamination width (1)
- Delaminationen (1)
- Destillation (1)
- Detection (1)
- Diagnostic antibodies (1)
- Dickenbestimmung (1)
- Dieselpartikelfilter (1)
- Diffusion (1)
- Digitales Zertifikat (1)
- Digitalization (1)
- Digitization (1)
- Dissociative electron attachment (DEA) (1)
- Double-strand break (DSB) (1)
- Drawings (1)
- Druckgasspeicher (1)
- Drug search (1)
- Drug trafficking (1)
- Ductility (1)
- Duftstoffe (1)
- Durchflusszytometrie (1)
- Durchflußzytometrie (1)
- Dye (1)
- Dynamic binding capacity (1)
- EC4SafeNano (1)
- EDX (1)
- EOS (1)
- EPMA (1)
- ETD (1)
- EXAFS (1)
- Ecodesign (1)
- Economic growth (1)
- Efficiency (1)
- Eigenschaften (1)
- Eingebettete Sensorik (1)
- Electrocatalysts (1)
- Electronic Power Device IC (1)
- Electropolishing (1)
- Elektrische Spezialzelle (1)
- Elektromagnetische Schmelzbadbeeinflussung (1)
- Elemental mass spectrometry (1)
- Elementanalyse (1)
- Ellipsometry (1)
- Embedded humidity sensors (1)
- Emissionsmesskammer (1)
- Endlager Konrad (1)
- Endlagerbehälter (1)
- Energie (1)
- Energiespeicherung (1)
- Energy (1)
- Energy Labelling (1)
- Englisch (1)
- Enrichment (1)
- Environment (1)
- Environmental analyses (1)
- Epoxy (1)
- Epoxy silanes (1)
- Erdboden (1)
- Erde (1)
- Ermüdung (1)
- Erosion (1)
- Estrichfeuchte (1)
- Ethanol (1)
- European Centre (1)
- Evanescent wave (1)
- Explosion regions (1)
- Explosionsschutz (1)
- Explosives (1)
- Exposure (1)
- Expression (1)
- FEM (1)
- Fab Fragment (1)
- False Positives (1)
- Fertigungsprozess (1)
- Festphasenextraktion (1)
- Feuchtemesstechnik (1)
- Feuerverzinkter Stahl (1)
- Flammability (1)
- Flammability Limit (1)
- Flood protection (1)
- Flood risks (1)
- Flow rate (1)
- Fluidische Anregung (1)
- Fluidischer Oszillator (1)
- Fluorescence (1)
- Fluorescence label (1)
- Fluoreszenzspektroskopie (1)
- Force controlled TMF testing (1)
- Formeln (1)
- Frequenzmodulation (1)
- Fugen (1)
- Fumonisin (1)
- Fundamentals (1)
- GC-ICP-MS (1)
- GHS Classifikation (1)
- GMR-Sensoren (1)
- Gaia-X (1)
- Galvanische Korrosion (1)
- Gas Adsorption (1)
- Gas Mixtures (1)
- Gas mixtures (1)
- Gasdetektion (1)
- Gassensorik (1)
- Gastheorie (1)
- Geant4 (1)
- Gefahrgut (1)
- Gefahrgut-Tankschiff (1)
- Gefügedegradation (1)
- Geoenergie (1)
- Geothermie (1)
- Getränkekühler (1)
- Glasspeicher (1)
- Glassy polynorbornenes (1)
- Gleichungssysteme (1)
- Glutaraldehyd (1)
- Glutaraldehyde (1)
- Gold (1)
- Gold particles (1)
- Gold-Nanopartikel (1)
- Gothic incursions (1)
- Ground penetrating radar (1)
- Ground water pollution (1)
- Größenausschlusschromatographie (1)
- Guideline (1)
- HBr (1)
- HCl (1)
- HPLC (1)
- Halomonas elongata (1)
- Hapten Immunoassay (1)
- Hard protein corona (1)
- Hartmann-Effekt (1)
- Hazardous substances (1)
- Hg porosimetry (1)
- High resolution MS (1)
- High temperature (1)
- High-performance concrete (1)
- High-purity iron (1)
- High-speed (1)
- Hochentropielegierung (1)
- Hochtemperaturverhalten (1)
- Hochwasserschutz (1)
- Hortfund (1)
- Human antibodies (1)
- Human antibody (1)
- Human factors (1)
- Human serum (1)
- Hybridoma (1)
- Hydrated DNA (1)
- Hydration shell (1)
- Hydrobromic acid (1)
- Hydrochloric acid (1)
- Hydrolysis (1)
- Hyperbranched polymer (1)
- IC50 (1)
- ICP-MS (1)
- IFAFRI (1)
- IGUS (1)
- IMS (1)
- ISI effectiveness (1)
- ISO 21363 (1)
- ISO/TC 202 (1)
- ISO/TC 202 Microbeam Analysis (1)
- ISO/TC 229 (1)
- ISO/TC 229 Nanotechnologies (1)
- Ideal delamination (1)
- Identification (1)
- Identity (1)
- Igg (1)
- Illicit drug (1)
- Immobilisierung (1)
- Immobilization (1)
- Immunglobulin (1)
- Immunoassay (1)
- Immunoglobulins (1)
- Immunoprecipitation (1)
- Immunosensor (1)
- Immunpräzipitation (1)
- Impedance spectroscopy (1)
- Impurity assessment approach (1)
- In-service inspection (1)
- Industrie 4.0 (1)
- Infrastruktur (1)
- Innovative Werkstoffe (1)
- Interface analysis (1)
- International drug trade (1)
- Interoperabilität (1)
- Ionenmobilitätsspektrometrie (1)
- Ionization (1)
- Iron Gall Ink Corrosion (1)
- Isotope ratio mass spectrometry (1)
- Java GUI (1)
- KMU (1)
- Kalibrierung (1)
- Kalzienieren (1)
- Kavernenspeicher (1)
- Klassifizierungssystem (1)
- Klon A1.1.1 (1)
- Klon EW75C (1)
- Kobaltlegierung (1)
- Kommunikation (1)
- Kondensatorentladungsfunke (1)
- Konformität (1)
- Konstruktionszeichnungen (1)
- Kontaktloses Impakt-Echo (1)
- Korrelationsmatrix (1)
- Korrespondierende relative Luftfeuchte (1)
- Korrosion im maritimen Bereich (1)
- Korrosionsindikation (1)
- Korrosionstest (1)
- Kreislaufwirtschaft (1)
- Kreuzreaktion (1)
- Kupfer (1)
- Kurzfaser-verstärkte Thermoplaste (1)
- LEE (1)
- LFIA (1)
- LIBS (1)
- Lab on a chip (1)
- Label (1)
- Laborarbeit (1)
- Laboratorium (1)
- Ladder sequencing (1)
- Lateral flow immunoassays (1)
- Latex particles (1)
- Leichtbeton (1)
- Leichte Gesteinskörnung (1)
- Leichtmörtel (1)
- Leise Fahrbahnbeläge (1)
- Lichtbogenofen (1)
- Life cycle analysis (1)
- Light elements (1)
- Liposomes (1)
- Low energy electrons (1)
- Luftgekoppelter Ultraschall (1)
- MMAE (1)
- MMC (1)
- MNPQ (1)
- MST (1)
- Machine Learning (1)
- Magnesium Alloy (1)
- Magnetic beads (1)
- Magnetische Materialcharakterisierung (1)
- Magnetische Messsysteme (1)
- Magnetische Messysteme (1)
- Magnetism (1)
- Manufacturing (1)
- Manufacturing-X (1)
- Mapping (1)
- Mapping of subsurface pollution (1)
- Markierung (1)
- Mass Spectroscopy (1)
- Mass content (1)
- Mass spectroscopy (MS) (1)
- Massenspektrometrie (1)
- MatLab (1)
- Material (1)
- Material design (1)
- Material moisture (1)
- Materialprüfung (1)
- Materials behavior (1)
- Mathematics and Statistics (1)
- Matrix effects (1)
- Mecklenburg-Vorpommern (1)
- Mediumentropielegierung (1)
- Mehr-Proben-Vorbehandeln/Kleben/Prüfen (1)
- Mercury Intrusion Porosimetry (1)
- Merrifield (1)
- Mertansine (1)
- Messgeräte (1)
- Messunsicherheit (1)
- Metabolomics (1)
- Metal assay approach (1)
- Metal foams (1)
- Metallurgie (1)
- Metallurgy (1)
- Method development (1)
- Micro-XANES (1)
- Micro-XRF (1)
- Microarray (1)
- Microbeam Analysis (1)
- Microplastic particles (1)
- Microplastics (1)
- Microscopic slides (1)
- Microstructure (1)
- Mikroparticles (1)
- Mini-UAV (1)
- Mischungsregel (1)
- Modulated photothermal radiometry (1)
- Monoclonal (1)
- Monoclonal Antibodies (1)
- Monoclonal antibody (1)
- Monoklonal (1)
- Monolith (1)
- Monomethyl Auristatin E (1)
- Multisensorik (1)
- Mutationen (1)
- Mykotoxin (1)
- Mykotoxine (1)
- N-capsid (1)
- N2 sorption (1)
- NAP-XPS (1)
- NHS-Iodacetamid-Crosslinker SIAB (1)
- NaCl-Methode (1)
- Nano characterization (1)
- Nano-characterisation (1)
- Nano-safety (1)
- Nanobody (1)
- Nanocubes (1)
- Nanodiamant (1)
- Nanotechnologie (1)
- Nanotechnologies (1)
- Narcotics (1)
- Nasssammlung (1)
- Near Ambient Pressure XPS (1)
- Near ambient pressure XPS (1)
- Near-infrared (1)
- Neutralisierende Antikörper (1)
- Neutron backscattering (1)
- Neutron radiography (1)
- Neutron scattering (1)
- Nichtrostender Stahl (1)
- Nickellegierung (1)
- Nitroaromaten (1)
- Nitrocarburieren (1)
- Nitromoschus (1)
- Non-destructive testing (1)
- Norm (1)
- Normen (1)
- Normung (1)
- Normung Roadmap (1)
- Nuclear power (1)
- Nucleocapsid-Protein (1)
- Nutrient recovery (1)
- OH radical (1)
- Oberflächen (1)
- Oberflächen behandeln (1)
- Oberflächenausführung (1)
- Oberflächenenergie (1)
- Online software (1)
- Open data (1)
- Optical Spectroscopy (1)
- Optical konstantyss (1)
- Organic coatings (1)
- Organic layers (1)
- Organic peroxides (1)
- Organic products (1)
- Organische Beschichtungen (1)
- Organische Filme (1)
- Oriented immobilization (1)
- Orientierte Immobilisierung (1)
- Oxidizers (1)
- PC (1)
- PCB (1)
- PES (1)
- PIM-1 (1)
- PRP-C18 (1)
- Particle Synthesis (1)
- Particle size and shape distribution (1)
- Patent (1)
- Payload (1)
- Peak overlap (1)
- Peer review (1)
- Peptid-Aptamer (1)
- Peptid-Synthese (1)
- Peptidbibliothek (1)
- Peptide coverage (1)
- Peptide library (1)
- Peptides (1)
- Performance comparison (1)
- Periodate oxidation (1)
- Periplasma (1)
- Permeable reactive barrier systems (1)
- Pflanzenvirus (1)
- Phase analysis (1)
- Phenylalanine (1)
- Photovoltaics (1)
- Physicochemistry (1)
- Phytoscreening (1)
- Pipeline (1)
- Plasma-Polymer (1)
- Plasmapolymere (1)
- Plasmapolymerisation (1)
- Plastic (1)
- Policy making (1)
- Polybrominated diphenylether (1)
- Polycarbonate (1)
- Polycyclic aromatic hydrocarbons (1)
- Polyethylen (1)
- Polyglycerol (1)
- Polymer beads (1)
- Polymers (1)
- Polymers of Intrinsic Microporosity (1)
- Polymerwerkstoff (1)
- Polypropylenfasern (PPF) (1)
- Polytetrafluorethylen (1)
- Pore volume distribution (1)
- Porosity (1)
- Porosität (1)
- Positionspapier (1)
- Potentialmessung (1)
- Power-to-Gas (1)
- Precision Profile (1)
- Pressure (1)
- Probe (1)
- Probenvorbereitung (1)
- Process sustainability (1)
- Processing (1)
- Programmierung (1)
- Projektmanagement (1)
- Protection (1)
- Protein (1)
- Protein engineering (1)
- Protein hydrolysis (1)
- Protein interaction (1)
- Protein quantification (1)
- Proteins (1)
- Prozess-Sensoren (1)
- Prozessindustrie (1)
- Prozessmanagement (1)
- Prozessüberwachung (1)
- Präzisionsprofil (1)
- Pulskompression (1)
- Pure iron (1)
- Purity assessment (1)
- Purity level (1)
- QI-Digital (1)
- Quality (1)
- Quality Assurance (1)
- Quality Infrastructure (1)
- Quality Management (1)
- Quality control (1)
- Quantifizierung realer Verformungen (1)
- RFID-sensors (1)
- ROS (1)
- Rauheit (1)
- Reactive oxygen species (1)
- Reaktive Brandschutzsysteme (1)
- Recombinant protein expression (1)
- Recycling- und Deponiestoffe (1)
- Reductive amination (1)
- Reference material (1)
- Reference-free investigation (1)
- Regeneration (1)
- Reinforcement (1)
- Rekombinante Antikörper (1)
- Renewable energy (1)
- Renewable energy technologies (1)
- Reparaturschweißen (1)
- Reproducibility crisis (1)
- Research Agenda (1)
- Resistance (1)
- Resonanzverfahren (1)
- Resource efficiency (1)
- Resources (1)
- Ressourceneffizienz (1)
- Restoration (1)
- Reststoffe (1)
- Reversed-phase (1)
- Risikoanalyse (1)
- Rohrprobekörper (1)
- Rostasche (1)
- Round robin test (1)
- Round-Robin (1)
- Röntgenabsorptionsspektroskopie (1)
- Röntgenstrukturanalyse (1)
- Rückgewinnung (1)
- SAFIA (1)
- SARS (1)
- SARS-CoV-2 antibody (1)
- SBAP (1)
- SC-ICP-MS (1)
- SDS PAGE (1)
- SEM (1)
- SEVESO III-Richtlinie (1)
- SIA (1)
- SIAB (1)
- SIMS (1)
- SPPS (1)
- SPR (1)
- Safe-by-Design (1)
- Safety characteristic data (1)
- Saure Hydrolyse (1)
- Schiffshavarie (1)
- Schlacke (1)
- Schweißnaht (1)
- Schwerflüchtige organische Verbindungen (1)
- Schwermetalle (1)
- Schwimmstabilität (1)
- Scythica Vindobonensia, (1)
- Security (1)
- Selbstentzündungsgefährdung (1)
- Selbstverdichtender Beton (SVB) (1)
- Self-assembled monolayer (SAM) (1)
- Self-reactive substances (1)
- Sensor (1)
- Sensorik (1)
- Sequenzierung (1)
- Sewage sludges (1)
- Sicherheit (1)
- Silanization (1)
- Silber(II)-oxid (1)
- Silberstiftzeichnung (1)
- Silica and Polystyrene Particles (1)
- Silverpoint drawing (1)
- Single cell ICP-MS (1)
- Single particle ICP-MS (1)
- Single-strand break (SSB) (1)
- Sintered (1)
- Site-selective bioconjugation (1)
- Sludge disposal (1)
- Smart Standard (1)
- Smarte Sensoren (1)
- Sodium chloride method (1)
- Soft protein corona (1)
- Solid phase (1)
- Solid-phase peptide synthesis (1)
- Speciation (1)
- Spectral interferences (1)
- Spectrum imaging (1)
- Split and mix technology (1)
- Sponsorship programme (1)
- Sprengstoffspurendetektion (1)
- Stahlkonstruktion (1)
- Standardization roadmap (1)
- Standards (1)
- Strain rate (1)
- Struktur (1)
- Strukturaufklärung (1)
- Strukturen (1)
- Störausfallwirkungsbetrachtung (1)
- Störfall-Verordnung (1)
- Succinimidyl(4-iodacetyl)aminobenzoat (SIAB) (1)
- Suffosion (1)
- Sulfo-SIAB (1)
- Sulfuric acid (1)
- Supraleiter (1)
- Surface (1)
- Surface Analysis (1)
- Surface analysis (1)
- Surface area (1)
- Surface chemical analysis (1)
- Surface derivatization (1)
- Surface groups (1)
- Sustainable development (1)
- Synchrotron Laue Contrast Radiography SLCR (1)
- Synchrotron Radiation (1)
- Synchrotron Refraction CT (1)
- Synchrotron based FTIR (1)
- TDS-Systeme (1)
- TED-GC/MS (1)
- THz-Wellen (1)
- TNT (1)
- TOPAS (1)
- TOPAS-nbio (1)
- TXRF-NEXAFS (1)
- Taxonomie (1)
- Technical progress (1)
- Technology transfer (1)
- Temperaturmessung (1)
- Tensile properties (1)
- Tensile test (1)
- Tentagel (1)
- Terminologie (1)
- Test methods (1)
- Test specification (1)
- Theory (1)
- Therapeutic antibodies (1)
- Thermal conductivity (1)
- Thermische Beanspruchung (1)
- Thermische Isolation (1)
- Thermisches Ausfugen (1)
- Thermoanalytical (1)
- Thermografie (1)
- Thin film (1)
- Thin film analysis (1)
- Tieftemperatursensor (1)
- Tissue Engineering (1)
- ToF-SIMS (1)
- Topographie (1)
- Toxin (1)
- Trastuzumab (1)
- Treatment (1)
- Tree cores (1)
- Trennen (1)
- Tribologie (1)
- Tribology (1)
- Tributyltin (1)
- Trinitrotoluol (1)
- Trypsin (1)
- Tyrosine (1)
- Ultra-high-purity iron (1)
- Ultrasound (1)
- VAMAS (1)
- Validation (1)
- Value (1)
- Verarbeitung (1)
- Verbundfestigkeit (1)
- Verflüssigter Wasserstoff (1)
- Vergällungsmittel (1)
- Verification (1)
- Verkehrswegebau (1)
- Vernetzung (1)
- Verschleiß (1)
- Verteilte faseroptische akustische Sensorik (1)
- Vhh (1)
- Vienna manuscript (1)
- VitraPOR (1)
- Vorhaben (1)
- WIG-Schweißen (1)
- Wasserstoff (1)
- Wasserstofferzeugung (1)
- Wasserstoffspeicher (1)
- Water analysis (1)
- Water polluntants (1)
- Water-bearing (1)
- Werkstoff (1)
- Werkstoffauswahl (1)
- Wirbelstromprüfung (1)
- Wirbelstromsenoren (1)
- Wischprobenahme (1)
- Writing Materials (1)
- X-ray Computed Tomography (1)
- X-ray Refraction (1)
- X-ray absorption analysis (1)
- X-ray spectrometry (1)
- XAFS (1)
- XANES-Spektrum (1)
- XRF analysis (1)
- Yield strength (1)
- ZFP (1)
- Zeichnungen (1)
- Zentrifugentechnologie (1)
- ZfP im Bauwesen (1)
- Zink-Elektrode (1)
- Zug-Druck-Schubprüfung (1)
- Zugglieder (1)
- Zugversuch (1)
- Zwangsspannung (1)
- binäres Regressionsverfahren (1)
- calculation (1)
- digitale Transformation (1)
- eAttestation (1)
- geschweißt (1)
- gold (1)
- k-values (1)
- nPSize (1)
- nahtlos (1)
- nichtrostender Stahl (1)
- optische Konstanten (1)
- pH Wert in Baustoffen (1)
- pH probe (1)
- programme (1)
- rekombinante Protein Expression (1)
- temperatures (1)
- thermische Sensibilität (1)
- transient (1)
- µ-XRF (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (63)
- 7.6 Korrosion und Korrosionsschutz (53)
- 1 Analytische Chemie; Referenzmaterialien (32)
- 8 Zerstörungsfreie Prüfung (27)
- 6 Materialchemie (23)
- 1.5 Proteinanalytik (19)
- 6.1 Oberflächen- und Dünnschichtanalyse (16)
- 4 Material und Umwelt (9)
- 7.1 Baustoffe (9)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (9)
- 1.8 Umweltanalytik (7)
- 8.4 Akustische und elektromagnetische Verfahren (7)
- 6.6 Physik und chemische Analytik der Polymere (6)
- 8.0 Abteilungsleitung und andere (6)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (6)
- 9 Komponentensicherheit (6)
- S Qualitätsinfrastruktur (6)
- 4.2 Material-Mikrobiom Wechselwirkungen (5)
- 5 Werkstofftechnik (5)
- VP Vizepräsident (5)
- VP.1 eScience (5)
- 1.4 Prozessanalytik (4)
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- S.2 Digitalisierung der Qualitätsinfrastruktur (4)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 9.2 Versuchsanlagen und Prüftechnik (3)
- 9.4 Integrität von Schweißverbindungen (3)
- 9.5 Tribologie und Verschleißschutz (3)
- 1.1 Anorganische Spurenanalytik (2)
- 1.2 Biophotonik (2)
- 3.2 Gefahrguttanks und Unfallmechanik (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (2)
- 5.4 Multimateriale Fertigungsprozesse (2)
- 6.3 Strukturanalytik (2)
- S.3 Ökodesign und Energieverbrauchskennzeichnung (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 1.9 Chemische und optische Sensorik (1)
- 2.0 Abteilungsleitung und andere (1)
- 3.0 Abteilungsleitung und andere (1)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (1)
- 3.6 Elektrochemische Energiematerialien (1)
- 4.3 Schadstofftransfer und Umwelttechnologien (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 5.0 Abteilungsleitung und andere (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 5.6 Glas (1)
- 6.0 Abteilungsleitung und andere (1)
- 7.2 Ingenieurbau (1)
- 8.6 Faseroptische Sensorik (1)
- 9.0 Abteilungsleitung und andere (1)
Wasserstoff stellt einen potenziellen Energieträger für den großskaligen Import von Energie nach Europa dar. Von seinen verschiedenen Speicherformen eignet sich hierfür insbesondere verflüssigter Wasserstoff, mit dem sich auf gleichem Volumen deutlich mehr Energie speichern lässt als bei der druckbasierten Speicherung. Verflüssigter Wasserstoff wird bei minus 253°C gespeichert und muss für dessen Transport lange bei dieser niedrigen Temperatur gehalten werden. Dies stellt besondere Herausforderungen an die thermische Isolation von Tanks. Der Erforschung nachhaltiger, kosten- und energieeffizienter sowie sicherer thermischen Isolationen wird im NICOLHy Projekt, unter Leitung der BAM, nachgegangen.
Produktion und Handel in immer komplexeren Wertschöpfungsnetzwerken, die fortschreitende digitale und grüne Transformation sowie technologische Innovationen sind in hohem Maße auf die verlässliche Sicherung und den effizienten Nachweis der Qualität, Sicherheit und Nachhaltigkeit von Waren, Dienstleistungen und Prozessen angewiesen. Unverzichtbar dafür ist eine moderne und leistungsfähige Qualitätsinfrastruktur (QI). Der Artikel stellt die Initiative QI-Digital, ihre Ziele und Aktivitäten für die digitale Transformation der QI vor.
A thousand times thinner than a human hair, nanoparticles (NPs) are finding applications in a range of modern products. However, as some can affect human health or the environment, knowing the types present is essential. Electron microscopy is the ‘gold standard’ for NP analysis, allowing identification based on manual size analysis, but a new method was required to analyse these particles quickly, accurately and in a consistent way.
The impact of magnetism on chemical ordering in face-centered cubic CrCoNi medium entropy alloy is studied by a combination of ab initio simulations, machine learning potentials, and Monte Carlo simulations. Large magnetic energies are revealed for some mixed L12 /L10 type ordered configurations, which are rooted in strong nearest-neighbor magnetic exchange interactions and chemical bonding among the constituent elements. There is a delicate interplay between magnetism and stability of MoPt2 and L12 /L10 type of ordering which may explain opposing experimental and theoretical findings.
Antikörper sind in der medizinischen Welt nicht mehr wegzudenken. Ihr Einsatz-Repertoire als Therapeutika für die Behandlung diverser Krankheiten und Infektionen weitet sich von Jahr zu Jahr mehr aus. Dabei basiert ein Großteil der verwendeten Antikörper zu diesem Zeitpunkt auf monoklonalen Antikörpern auf Basis von Hybridomazellen. Doch hier könnten rekombinante Antikörper aufgrund ihrer Vektor-basierten Expression eine vielversprechende und womöglich sogar revolutionierende Alternative bieten. So ergeben sich neue Optimierungsoptionen für Merkmale wie Affinität, Stabilität und Kompatibilität über Anpassungen auf genetischer oder posttranslationaler Ebene. Allerdings ergibt sich kein Anwendungszweck ohne die vorhergehende detaillierte Charakterisierung der Antikörper. Denn nur mit spezifischem Wissen über die diversen Eigenschaften und Wechselwirkungen kann eine effektive und präzise Verwendung in der Diagnostik und Therapeutik gewährleistet werden und auf diese Weise Leben retten.
Aus diesem Grund beschäftigt sich diese Masterarbeit mit der Vertiefung der rekombinanten Antikörper-Thematik. Dazu soll ein Anti-Tetanus-Antikörper erstmals rekombinant in verschiedenen Zelllinien hergestellt und anschließend über umfangreiche analytische Verfahren mit einem Fokus auf die Einflussanalyse der unterschiedlichen posttranslationalen Glykosylierungen charakterisiert werden. Zu diesem Zweck wurden als Grundlage einerseits zwei P1316-Dual-Expressions-Vektoren mit variierenden Insert-Positionen der schweren und leichten Kette durch Gibson-Assembly sowie individuellen pRK5-Plasmide für eine separiert Expression der Antikkörperketten mithilfe Restriktionsfragment-Ligation generiert. In einer Gegenüberstellung der der Expressionsausbeuten stellte sich die Überlegenheit der P1316-Plasmid-Konfiguration heraus, in der das Leichtketten-Insert an der ersten Expressionsstelle positioniert ist. Deshalb wurde dieser Vektor als Ausgangspunkt für die anschließende hochskalierten Herstellung des Anti-Tetanus-Antikörpers in Expi293F-GnTI- und ExpiCHO-S-Zellen verwendet. Ein ELISA bestätigte die Bindungsaktivität der rekombinanten Antikörper am Tetanus-Toxoid unabhängig vom Expressionssystem. Nach einer folgenden Optimierung der für die Aufreinigung verwendeten Protein-A-Affinitätschromatographie, wurde über weitere Charakterisierungsmethoden wie Größenausschlusschromatographie und dynamische Lichtstreuung eine vergleichbare Aggregation aufgrund der sauren Elution aufgezeigt. In diesem Kontext wurde die Notwendigkeit einer Zweistufen-Präparation mit Affinitäts- und Größenausschlusschromatografie für den Erhalt monodisperser Proben verdeutlicht. Zudem wurden die verschiedenen intakten Massen mitsamt ihrer spezifischen Glykan-abhängigen Streumaßen in Relation zum monoklonalen NISTmAB-Referenzantikörper bestimmt. Dabei konnte den Erwartungen nach sowohl die geringere Masse als auch die uniformere Glykosylierung der in Expi293 GnTI- exprimierten Immunoglobuline in Relation zum ExpiCHO-S-Antikörper nachgewiesen werden. Anschließend wurde das Stabilitätsverhalten mittels thermischer Entfaltung und dynamischer Lichtstreuung über einen ausgeweiteten Zeitraum sowie verschiedenen Temperaturen dokumentiert. Grundlegend wurde eine höhere thermische Stabilität der zweiten konstanten Schwerketten-Domäne des aus ExpiCHO-S-Zellen stammenden Antikörpers nachgewiesen. Außerdem konnte eine problemlose Lagerungsfähigkeit beider unterschiedlich glykosylierter Antikörper bei Raumtemperatur für mindestens 4 Wochen festgestellt werden. Des Weiteren wurde die Langzeitlagerung im Rahmen der Auswirkung von Gefrier-Auftau-Zyklen mit gleichbleibenden Methoden sowie zusätzlicher Größenausschlusschromatographie erprobt. Hierbei stellte sich der Erhalt der strukturellen Integrität nach bis zu 15 Zyklen heraus. Allerdings geht die Monodispersität bereits nach wenigen Zyklen verloren, wobei die geringfügiger glykosylierten Expi293F-GnTI-Anti-Tetanus-Antikörper eine stärkere Beeinträchtigung durch multiple Gefrier-Auftau-Zyklen aufwiesen.
Die Pulskompression wird in der Radartechnik eingesetzt, um den Signal-Rausch-Abstand zu erhöhen. Das Ziel ist es die Entdeckungswahrscheinlichkeit eines Nutzsignals bei gleichbleibender Auflösung zu erhöhen. Durch den Einsatz von Barker Codes oder komplementären Golay Codes werden Sendesignale von Luftultraschallanwendungen pulscodiert. Dies ermöglicht in der zerstörungsfreien Prüfung die Inspektion von dickeren Bauteilen, da die Signalenergie durch zeitlich gestreckte Sendesignale bei gleicher Auflösung vergrößert wird.
In dieser Arbeit wird die Pulskompression durch die Einführung von unipolaren Sequenzen zur Pulscodierung für thermoakustische Ultraschallwandler ermöglicht. Der Signal-Rausch-Abstand wird in der Anwendung der Pulscodierung und anschließenden Filterung mit einem signalangepassten Filter in Luftultraschallmessungen mit dem thermoakustischen Wandler und Wandlern aus zellulärem Polypropylen erhöht.
Nanoparticles (NPs) are tiny – around 1 to 100 billionths of a meter – and can have different chemistries and behaviours than the same material of larger size. This property has led to advances in a wide range of industries, but it can also confer toxicity. Size measurements are the main way NPs are identified but a lack of standardised methods for identifying ones with complex shapes has hindered evaluation of their potential harm.
Bio-electrochemical CO2 conversion into organic products using precious-metal free electrocatalysts
(2024)
For the realization of a sustainable economy, it is of great importance to make use of CO2 for the production of multi-carbon organic chemicals used as feedstock in the chemical industry as well as carbon-neutral fuels (Varela et al. 2019). A promising approach is the electrochemical CO2 reduction followed by microbial conversion of the reduced products.
This document constitutes the Strategic Research Agenda (SRA) for the European Metrology Network for Mathematics and Statistics in Metrology (EMN Mathmet). The EMN Mathmet is an alliance of European National Metrology Institutes (NMIs), Designated Institutes (DIs) and an EMN Partner that aims to strengthen research and cooperation in the field. The SRA has been developed within a European project (EMPIR 18NET05 MATHMET) to promote and support the network. The SRA was developed based on a consultation process with stakeholders and the strategies of individual NMIs and DIs, and in alignment with the EURAMET 2030 strategy.
As a key result, the SRA defines a long-term research goal: the EMN Mathmet will coordinate research to strengthen the trust in algorithms, software tools and data to underpin digital transformation. For this purpose, new emerging research topics where algorithms, software tools and data play a significant role were identified: (i) Artificial Intelligence and Machine Learning, and (ii) Computational Modelling and Virtual Metrology. The foundation for the development of these new topics is given by the traditional focus on (iii) Data Analysis and Uncertainty Evaluation. The SRA characterises the future needs and challenges in the field of mathematics and statistics in metrology and provides an outline of how the EMN Mathmet can meet these new emerging requirements.
Harmonized and interoperable national Quality Infrastructure (QI) systems are essential for fostering cooperation, promoting mutual trust, and facilitating trade. The true potential of the QI is realized when its elements and actors are seamlessly integrated into a cohesive digital QI ecosystem. Recent developments towards industrial international data spaces enable such an ecosystem but require the integration of QI principles. Recognizing the lack of such a platform, Quality-X aims at setting the stage for the implementation of a QI ecosystem in international data spaces (IDS), GAIA-X and related German and European projects dedicated to secure data sharing. Quality-X is not about the construction of a platform; it is the creation of an inclusive QI ecosystem with harmonized interfaces. Instead of imposing rigid data structures, it prioritizes interoperability. Through the utilization of Decentralized Identifiers (DIDs), Verifiable Credentials, and Identity Hubs, Quality-X seeks seamless interactions across diverse service provider systems.
This white paper introduces the concept and vision of Quality-X and discusses the general prerequisites for integrating QI processes within data spaces. Further on, we introduce existing testbeds, which will serve as an experimental proving ground for exploring various use cases related to the implementation of the vision of a QI-Digital.
+++
Harmonisierte und interoperable nationale Qualitätsinfrastrukturen (QI) sind für die Förderung der Zusammenarbeit, des gegenseitigen Vertrauens und der Erleichterung des Handels unerlässlich. Das wahre Potenzial der QI kommt zum Tragen, wenn ihre Elemente und Akteure nahtlos in ein kohärentes digitales QI-Ökosystem integriert werden. Die jüngsten Entwicklungen hin zu industriellen internationalen Datenräumen ermöglichen ein solches Ökosystem, erfordern jedoch die Integration von QI-Prinzipien. Angesichts des Fehlens einer solchen Plattform zielt Quality-X darauf ab, die Voraussetzungen für die Umsetzung eines QI-Ökosystems in internationalen Datenräumen (IDS), GAIA-X und verwandten deutschen und europäischen Projekten zum sicheren Datenaustausch zu schaffen. Bei Quality-X geht es nicht um den Aufbau einer Plattform, sondern um die Schaffung eines umfassenden QI-Ökosystems mit harmonisierten Schnittstellen. Anstatt starre Datenstrukturen aufzuerlegen, steht die Interoperabilität im Vordergrund. Durch die Verwendung von dezentralen Identifikatoren (DIDs), überprüfbaren Berechtigungsnachweisen und Identitäts-Hubs strebt Quality-X eine nahtlose Interaktion zwischen verschiedenen Systemen von Dienstleistern an.
Dieses Whitepaper stellt das Konzept und die Vision von Quality-X vor und erörtert die allgemeinen Voraussetzungen für die Integration von QI-Prozessen in Datenräumen. Darüber hinaus stellen wir bestehende Testbeds vor, die als experimentelles Versuchsfeld für die Erforschung verschiedener Anwendungsfälle im Zusammenhang mit der Umsetzung der Vision einer QI-Digital dienen sollen.
Aus wirtschaftlichen, konstruktiven sowie ästhetischen Aspekten werden moderne Stahlbaukonstruktionen immer schlanker und leichter ausgeführt. Dazu werden zunehmend hochfeste Feinkornbaustähle mit Dehngrenzen ≥ 690 MPa eingesetzt, wodurch eine Gewichtsreduzierung von 30 % bis 50 % und eine Kostenersparnis von 5 % bis 15 % erreicht werden kann.
Das Potential hochfester Feinkornbaustähle ist unter Beachtung der heutigen Richtlinien und Regelwerke jedoch nicht ohne weiteres nutzbar. Durch das Forschungsvorhaben wurde der Einfluss der Wärmeführung auf die Eigenspannungsausbildung und Kaltrissbildung unter Berücksichtigung realitätsnaher Steifigkeitsbedingungen untersucht. Auf der Grundlage dieser Erkenntnisse wurde ein Beitrag zur Verbesserung der Verarbeitungsrichtlinien erarbeitet, welche dem Verarbeiter eine sichere schweißtechnische Verarbeitung bei verbesserter Ausnutzung der Materialeigenschaften ermöglicht. Vor allem die Tragfähigkeit und die Sicherheit der Schweißverbindung bestimmen die Bemessung der Konstruktion und somit den nachhaltigen und ökonomischen Einsatz dieser Güten. Der Zusammenhang zwischen der Höhe der entstehenden Eigenspannungen und der Wärmeführung in realen Konstruktionen ist zurzeit nur qualitativ überschaubar und führt zu einer eher konservativen Auslegung heutiger Schweißkonstruktionen. Die wirtschaftliche Verarbeitung hochfester Stähle wird neben dem Erreichen anforderungsgerechter mechanischer Eigenschaften im Schweißnahtbereich vor allem durch die Vermeidung von Kaltrissen bestimmt. Die diesbezüglichen Empfehlungen in den geltenden Regelwerken beruhen jedoch vornehmlich auf Erkenntnissen aus Laborschweißungen an Kleinproben unter freier äußerer Schrumpfung. Die Hauptursachen für die Entstehung von Eigenspannungen wie inhomogene, lokale Erwärmung und Abkühlung der schweißnahtnahen Bereiche und insbesondere die konstruktive Schrumpfbehinderung infolge umgebender Montagegruppen werden damit jedoch nicht abgebildet. Der Einfluss der Wärmeführung, insbesondere der lokalen Vorwärmung, auf die Eigenbeanspruchung einer Konstruktion ist derzeit weitgehend unbekannt.
Ziel des Forschungsvorhabens war es, den Einfluss der Wärmeführung auf die Eigenspannungsausbildung in geschweißten Konstruktionen zu quantifizieren sowie Aussagen zur Beeinflussung und Absenkung der Eigenspannungen und somit der Gesamteigenbeanspruchung von Schweißkonstruktionen zu erarbeiten. Dazu wurden durch die sukzessive Steigerung des Einspanngrades der Zusammenhang zwischen Wärmeführung und resultierender Eigenspannung unter zusätzlicher Schrumpfbehinderung geklärt. Ferner wurde die Übertragbarkeit der den Regelwerken zugrundeliegenden Kleinprobenergebnisse auf reale Konstruktionen untersucht. Mithilfe systematischer Klein- und Großlastschweißversuche an definiert schrumpfbehinderten Proben konnte der Einfluss der Wärmeführung sowohl auf die lokalen nahtnahen Eigenspannungen als auch globale Eigenbeanspruchungen durch Reaktionsspannungen analysiert werden. Es zeigte sich, dass eine Reduktion der lokalen Eigenspannungen und der Eigenbeanspruchung von geschweißten Konstruktionen durch eine geringere Wärmeeinbringung möglich ist. Eine Absenkung der Zwischenlagentemperatur erwies sich dabei unter anderem als besonders günstig. Damit ist es möglich vorhandene Wärmeführungskonzepte für hochfeste Stähle zu optimieren und dadurch die Kaltrissbildung zu vermeiden.
Mykotoxine sind sekundäre Stoffwechselprodukte, die von Schimmelpilzen gebildet werden. Sie sind unvermeidliche Lebensmittelkontaminanten und stellen daher ein ernstes Gesundheitsrisiko für Mensch und Tier dar. Aus diesem Grund hat die Europäische Kommission Vorschriften erlassen, die Höchstwerte für Mykotoxine in bestimmten Lebensmitteln vorsehen. Um die gesetzlichen Grenzwerte einzuhalten, müssen in der Lebensmittelindustrie Mykotoxinanalysen der eingehenden Waren durchgeführt werden.
Gegenwärtig umfasst die Analyse zeitaufwändige Probenvorbereitungsschritte, denen in der Regel eine chromatographische Analyse folgt.
Immunoassays ermöglichen eine Vor-Ort-Analyse, aber in der Regel sind für feste Lebensmittelproben lösungsmittelbasierte Extraktionsschritte erforderlich. Da Immunoassays in der Regel nicht mit den hohen Lösungsmittelkonzentrationen kompatibel sind, die üblicherweise für die Mykotoxinextraktion verwendet werden (z.B. Acetonitril oder Methanol), war es das Ziel dieser Arbeit, ein Extraktionsverfahren für die Mykotoxine Deoxynivalenol und Ochratoxin A aus Weizenmehl und Getreide zu entwickeln, das für Immunoassays und -sensoren verwendet werden kann. Vier verschiedene Lösungsmittel, Methanol (10 %), Ethanol (5 %) und Acetonitril (10 %) sowie Milli-Q-Wasser wurden für die Extraktion des Analyten Deoxynivalenol getestet. Um negative Umweltaspekte zu vermeiden und aufgrund der vergleichbaren Extraktionseffizienz von Milli-Q-Wasser gegenüber den anderen Lösungsmitteln, wurde Milli-Q-Wasser als Extraktionslösung im optimierten Extraktionsprotokoll für Deoxynivalenol verwendet.
Es wurden verschiedene Extraktionsbedingungen, wie die Extraktionszeit, das Lösungsmittel-Feststoff-Verhältnis, der Filtrationsschritt, der Zentrifugationsschritt sowie die Zusammensetzung des Wassers untersucht. Auf der Grundlage der Ergebnisse wurde ein Extraktionsprotokoll festgelegt, mit dem Wiederfindungsraten in einem Bereich von x bis x erzielt wurden. Das Extraktionsprotokoll umfasste die Extraktion von 2 g Weizenmehl mit 40 ml Milli-Q-Wasser für 30 Minuten, die anschließende Zentrifugation bei 3000 U/min für 15 Minuten bei 4 °C und die Filtration des Überstands.
Liaison activities within ISO/TC 202 'Microbeam Analysis' which are relevant to ISO/TC 229 'Nanotechnologies' are reported acoording to the structure defined by ISO/TC229 Nanotechnologies Liaisons Coordination Group (NLCG): new standards/documents, coordination issues, and further detailed specific information, e.g. publications, events, comments.
Das gesellschaftliche Ziel der Defossilisierung der Energieversorgung erfordert eine disruptive Veränderung der Wärmebereitstellung. In Berlin und in den größten Brandenburger Städten Potsdam und Cottbus werden noch über 80 % der Nutzwärme über fossile Energieträger bereitgestellt. Die notwendigen Veränderungen erfordern Lösungen, die den tiefen Untergrund der Region nutzen. Allein die Nutzung der tiefen Geothermie kann mindestens 25% des Wärmebedarfs in Deutschland decken. Die Infrastruktur zur Verteilung dieser erneuerbaren Wärme ist bereichsweise vorhanden. Sie muss allerdings lokal und in ländlichen Gebieten weiter ausgebaut werden.
Für die Sektoren Strom und Verkehr steht zwar Energie insbesondere aus Sonne und Wind bereit, aber wegen des zeitlich variablen Angebots besteht ein erheblicher Bedarf an großtechnischen Speichern für Strom und Wärme oder auch für Energieträger (z. B. Wasserstoff). Die saisonale oder temporale Überproduktion an Strom und Wärme aus erneuerbaren Energien zwingt dazu, eine urbane Speicherinfrastruktur aufzubauen, um eine grundlastfähige und bedarfsgerechte Lieferung zu realisieren. Hinzu kommt die Aufgabe das Treibhausgas Kohlendioxid aus der Atmosphäre zu reduzieren und unterirdisch dauerhaft zu lagern. Auch hier werden Speichertechnologien und ‐räume benötigt.
Die nachhaltige energetische Nutzung des unterirdischen Raumes ist geeignet, entscheidende Beiträge zu einer zukünftigen Energiewirtschaft ohne fossile Brennstoffe zu leisten. Diese große interdisziplinäre Aufgabe erfordert die Zusammenarbeit vieler Fach‐, und Forschungseinrichtungen, die im Raum Berlin‐
Brandenburg vorhanden sind und in einer regionalen Forschungsallianz gebündelt werden sollen. Für die Region Berlin‐Brandenburg ergibt sich daraus die Chance, eine Schlüsselrolle in der Grundlagen‐ und angewandter Forschung zur Transformation des Energiesystems zu übernehmen und weltweit als Vorbild zu dienen.
Im vorliegenden Papier werden die Formen einer nachhaltigen Geoenergienutzung, das geologische Potenzial der Region Berlin Brandenburg und dessen bisherige geoenergetische Nutzung dargestellt. Aus diesem Wissen wird der Ist‐Zustand hinsichtlich des energiewirtschaftlichen Potenzials und der sich daraus ergebenden Nutzungsoptionen abgeleitet, um darauf aufbauend Maßnahmen darzustellen, mit denen spürbare Beiträge zur Dekarbonisierung erreicht werden können. Daraus ergeben sich Handlungsempfehlungen für die Region, verbunden mit einem möglichen Beitrag der GEB² zum Risikomanagement, Investitionen in Schlüsseltechnologien, der Aus‐ und Weiterbildung, sowie der Akzeptanzerhöhung für geoenergetische Projekte.
DICONDE in der ZfP
(2023)
DICONDE (Digital Imaging and Communication in Non-Destructive Evaluation) ist ein offener internationaler Standard zur Speicherung und zum Austausch industrieller Prüfdaten und prozessbezogener Informationen. Der DICONDE-Standard definiert sowohl die Semantik für eine strukturierte Speicherung von Daten als auch die netzwerkbasierte Kommunikation zwischen zwei Endpunkten. Damit lassen sich viele Vorgänge von Prüfprozessen digital und sicher abbilden und gleichzeitig normative Anforderungen wie eine Rückführbarkeit zum Prüfer und Prüfobjekt sowie eine Reproduzierbarkeit von Prüfergebnissen erfüllen.
DICONDE (Digital Imaging and Communication in Non-Destructive Testing) is an open international standard for storing and exchanging industrial test data and process-related information. The DICONDE standard defines both the semantics for structured storage of data and the network-based communication between two endpoints. This allows many test processes to be mapped digitally and securely, while at the same time meeting normative requirements such as traceability to the tester and test object and reproducibility of test results.
Die Verwendung hochfester Feinkornbaustähle hat für viele Anwendungen des Stahlbaus ein großes Potenzial für gewichtsoptimierte, effiziente Strukturen mit ho-her mechanischer Beanspruchbarkeit. Weitere Zugewinne an Effizienz sind durch generative Fertigungsschritte sowie bionische Bauweisen erzielbar. Hierzu stehen bereits kommerzielle hochfeste drahtförmige Zusatzwerkstoffe für formgebendes MSG-Schweißen zur Verfügung. Dem Einsatz stehen noch fehlende quantitative Aussagen zu den fertigungsbedingten Beanspruchungen und der Bauteilsicherheit während Herstellung und Betrieb im Wege. Dies betrifft insbesondere prozess- sowie materialbedingte Einflüsse und die konstruktive Schrumpfbehinderung verbunden mit der Ausbildung hoher Zugeigenspannungen und damit zusammenhängenden Kaltrissbildung.
Hierfür wurden im Projekt detaillierte und anwenderbezogene Kenntnisse zu den komplexen Wechselwirkungen zwischen Schweißprozess und Wärmeführung während der Fertigung, der metallurgischen Vorgänge und insbesondere der vorliegenden konstruktiven Einflüsse auf die entstehenden Eigenspannungen erarbeitet, um ein frühzeitiges Bauteilversagen aufgrund eines hohen fertigungsbedingten Beanspruchungsniveaus bis hin zu einer Rissbildung während der Fertigung sicher zu vermeiden. Gleichzeitig wurden die Einflüsse auf die mechanisch-technologischen Gütewerte systematisch analysiert. Zudem wurden die Auswirkungen trennender Verfahren durch Entfernen der Substratplatte sowie durch die spanende Bearbeitung der Vorformlinge zu Endbauteilgeometrien geklärt, da diese unmittelbar den Eigenspannungszustand beeinflussen und deutlichen Verzug der Bauteile auslösen.
Für das generative Schweißen konnten Verarbeitungsempfehlungen sowie Normenvorgaben erarbeitet werden. Dies hilft insbesondere KMU eine wirtschaftliche, beanspruchungsgerechte und risssichere generative Fertigung von Bauteilen aus hochfesten Feinkornbaustählen zu ermöglichen.
Es handelt sich hierbei um die erste Veröffentlichung einer verifizierbaren eAttestation (DCC mit DAkkS-Siegel). Sie wurde vom akkreditierten Kalibrierlabor D-K-11075-08, im Rahmen des QI-Digital Vorhabens, für den Fachbereich 8.1 erstellt und dient im Zusammenhang mit dem Vortrag "Digitale Kalibrierzertifikate – die Umsetzung in akkreditierten Laboratorien" auf dem 324. PTB-Seminar "Berechnung der Messunsicherheit – Empfehlungen für die Praxis" als Anschauungsmaterial für die Digitalisierung in der Metrologie.
In den Zeiten der Globalisierung und der beschleunigten technologischen Entwicklungen lassen sich in den Industrieländern nur mit einer entsprechenden Innovationsdynamik und -dichte die Herausforderungen im Hinblick auf Wachstum, Beschäftigung und Strukturwandel erfüllen. Grundvoraussetzung hierfür ist eine leistungsfähige Forschung. Um die Forschungsinfrastruktur in der Bundesrepublik zu erhalten und global wettbewerbsfähig zu bleiben, sind verstärkte Investitionen des Staates und der Wirtschaft notwendig. Mit den Investitionen im Rahmen der Hightech-Strategie hat die Bundesregierung einen wichtigen Schritt zur Förderung des wissenschaftlich-technischen Fortschritts in Deutschland getan. Die Investitionen in die Forschungsinfrastruktur des Landes sind nun von den Forschungseinrichtungen und Universitäten effektiv und effizient zu nutzen.
Für einen möglichst wirksamen Einsatz der Forschungsetats sind Forschungsprogramme sowohl für die Forschungseinrichtung als auch für die Mittelgeber ein wichtiges Instrument im Hinblick auf die Darstellung der Aktivitäten. Dies gilt insbesondere für die Ressortforschungseinrichtungen des Bundes, zu denen die Bundesanstalt für Materialforschung und -prüfung (BAM) zählt. Diese Einrichtungen verfügen über einen klaren Auftrag und ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Forschungsprogramme dienen daher besonders in diesen Einrichtungen dazu, Perspektiven im Bereich ihres Aufgabenfeldes sowie ihre Forschungsaktivitäten transparent darzustellen und politisch vertretbar zu machen.
Das vorliegende Forschungsprogramm der BAM gibt einen Überblick über die in den nächsten Jahren aktuellen Forschungsthemen und die hierfür erforderlichen Ressourcen und Rahmenbedingungen.
The outbreak of SARS-CoV-2 in December of 2019, led to a worldwide still on-going pandemic. Since then, several so-called waves of SARS-CoV-2 infections, a time period with a high and fast rising number of new infections, have occurred all over the world. Classic surveillance approaches are hardly applicable, and further, non-detected cases cannot be covered by them. Wastewater-based Epidemiology (WBE) was proven to be a reliable tool for the prediction of new SARS-CoV-2 infection waves, due to the discharge of virus particles in fecal shedding of infectious people. Until now, for the monitoring of SARS-CoV-2 in wastewater, Polymerase Chain Reaction (PCR) is used as analytical tool. Even though PCR is a highly sensitive analytical tool, is presents several disadvantages, such as the need for trained personnel, specific technical equipment, as well as a difficult performance. An analytical tool, to which these disadvantaged do not apply, are immunoassays. In this work, a sandwich Enzyme-Linked Immunosorbent Assay (ELISA), with the immobilization of the capture antibodies on the surface of a Microtiter Plate (MTP), as well as a sandwich Magnetic Bead-Based Assay (MBBA), with immobilization of the capture antibodies on the surface of Magnetic Beads (MBs), targeting the SARS-CoV-2 N-protein, were developed and optimized. Both assay formats were performed with a colorimetric and chemiluminescent detection. The developed assay is composed of the two monoclonal antibodies (mAb) AH2 and DE6 - which was biotinylated in the course of the work - which bind to two different epitops of the antigen N-protein. As tracer, Neutravidin-HRP was used, which binds, through interaction of the Neutravidin with the biotin, to the mAb DE6-Biotin. The assay development and optimization procedure included the investigation of the surface saturation with the mAb AH2, the concentration and dilution of the mAb DE6-Biotin and Neutravidin-HRP, the ideal MBs, the ideal coating as well as dilution buffers, and the colorimetric and chemiluminescent substrates. For the developed and fully optimized colorimetric ELISA, a test midpoint x0 of 388 μg/L, for the chemiluminsecent ELISA of 371 μg/L, for the colorimetric MBBA of 251 μg/L and for the chemiluminescent MBBA of 243 μg/L was obtained. Validation of the colorimetric MBBA was done by measurement of three wastewater samples collected at the Wastewater Treatment Plant (WWTP) Potsdam. Whilst no N-protein could be detected in the samples, by spiking of the wastewater samples with certain concentrations of the N-protein, 10- to 18-times lower concentrations could be back-calculated, which can be attributed to matrix-effects of the wastewater sample. Next to the matrix-effects, also several other reason exist, why no N-protein could be determined in the samples. Because of that, further investigation of the handling, and the measurement of the wastewater samples, as well as the improvement of the assay sensitivity through further optimization steps or exchange of the antibodies, is still necessary.
Das Ziel der vorliegenden Arbeit war die rekombinante Herstellung der AnFAO in E. coli, welche ursprünglich von A. niger produziert wird, und deren anschließende Anwendung in der Entwick-lung eines Fumonisin- Biosensors für die Lebensmittelanalytik. In Bezug auf die aktuell steigen-den Lebensmittel- und Rohstoffpreise ist die Entwicklung eines Schnelltestsystems zur Detektion von Kontaminationen mit Mykotoxinen besonders gefragt, da zusätzliche Verluste und Kosten verhindert werden können. Für die Herstellung der AnFAO als MBP-Fusionsprotein und Biotin-Fusionsprotein mit zusätzlichem 6x His-Tag wurden die pET-MBP-AnFAO und pRSET-BH6-An-FAO Expressionsvektoren erfolgreich konstruiert. Die lösliche Expression im Cytoplasma wurde von MBP-AnFAO erreicht, wobei die Expression von BH6-AnFAO in inclusion bodies erfolgte und keine Aktivität des Enzyms nachgewiesen wurde. Die Enzymaktivität von MBP-AnFAO wurde im optischen Assay und amperometrisch durch die Detektion von H2O2 ermittelt. Im optischen Assay wurde die maximale spezifische Aktivität von 2,45 U/mg bei 45 °C, einer Enzymkonzentration von 3 μM und 50 μM FB1 erreicht. Generell wurden mit FB1 als Enzymsubstrat höhere Fluoreszenzsig-nale und dementsprechend höhere Enzymaktivitäten als für FB2 beobachtet. Es wurde ein linearer Zusammenhang der Enzymaktivitäten mit der Substratkonzentration beobachtet. Außerdem wurde ein Anstieg der H2O2-Konzentration mit zunehmender Inkubationszeit (bis zu 60 Minuten) erkannt. Des Weiteren wurde der Einfluss des MBP-Fusionsproteins auf die Enzymaktivität des AnFAO untersucht. Dabei wurde anhand von wesentlich geringeren Aktivitäten für AnFAO allein ein eventueller Einfluss des MBP auf dessen Aktivität festgestellt. Ein elektrochemischer Aufbau wurde zur Entwicklung eines Fumonisin- Sensors genutzt. Dazu wurde nachgewiesen, dass FB1 von rekombinant hergestelltem MBP-AnFAO unter Bildung von NH3 und H2O2 zu weniger toxi-schem FB1, dem FPy1, oxidiert werden kann. An der PB/Kohlenstoff-Elektrode, welche sensitiver gegenüber H2O2 und stabiler als die CoPC/Kohlenstoff Elektrode war, wurde die Reduktion des enzymatisch gebildeten H2O2 gemessen. Die Erstellung einer FB1- Kalibriergerade mit FB1- Lösun-gen verschiedener Konzentrationen zeigte, dass das Enzym auch in immobilisierter Form in der Lage ist unterschiedliche Konzentrationen an FB1 zu desaminieren. Dazu gehört auch der Kon-zentrationsbereich unterhalb des festgelegten Grenzwertes von 2,7 μmol/kg für Fumonisin. Die amperometrischen Kurven hierfür wurden an der PB/Kohlenstoff-Elektrode erfolgreich aufge-nommen. Störungen des H2O2- Redoxstroms durch das Enzym, der Enzymsubstrate und der Ne-benprodukte während der amperometrischen Messung wurden ausgeschlossen. Sowohl im opti-schen als auch im amperometrischen Assay wurde ausschließlich das enzymatisch gebildete H2O2 bestimmt.
Virus-like particles are of great interest. Due to the lack of functional amino acids, they are non-infectious and are widely investigated for their usage in the biomedical field, such as nanomaterials, vaccines, drug delivery.
This thesis is about the engineering of virus-like particles, which are formed by self-assembly of LRV1 capsid proteins. Basis was a publication by Procházková et al. (2021), where the structure of virus-like particles, derived from recombinant LRV1 capsid proteins, was determined using cryo-electron microscopy.
Goal of my work was to investigate, whether it is possible to modify the surface of LRV1 virus-like particles by protein engineering. Next to an LRV1 capsid protein with a C-termini polyhistidine-tag like in the publication, a genetically modified LRV1 capsid protein with an internal polyhistidine-tag was supposed to be expressed. It was supposed to be analyzed, whether it still comes to a self-assembly of the capsid proteins.
The genetical constructs were generated by PCR based on a complementary LRV1 DNA, cloned into an expression vector, and using Sanger sequencing it was shown that the amino acid sequences were like expected. For the recombinant expression different E. coli (BL21 STAR (DE3), BL21 (DE3) pLysS, BL21 STAR (DE3) pRARE3 and T7 express lysY/Iq) strains were used, as well as different expression conditions tested by varying temperature, medium, isopropyl-ß-D-thiogalactoside oncentration, and induction duration. Best results were obtained expressing in T7 express lysY/Iq for 5 hours in Terrific Broth medium at 16 °C and 3 mM Isopropyl ß-D-1thiogalactopyranoside. After that, the recombinant proteins were purified under native conditions by their polyhistidine-tags using nickel affinity chromatography. Overall, a higher yield was obtained for the capsid protein with the C-termini polyhistidine-tag during expression, which was also visible in all following experiments. The expression of both constructs in E. coli was comparably low. Still, it was possible to validate for virus-like particles for both proteins using transmission electron microscopy. Thus, it was demonstrated for the first time that surface-modified LRV1 capsid proteins are able to assemble into virus-like particles. For further experiments and higher yield of soluble LRV1 capsid proteins for virus-like particle production, a different expression system should be used: Therefore, the LEXSY expression system should be optimal, it bases on Leishmania tarenolae, a natural LRV1 host system.
Die voranschreitende Digitalisierung, die Globalisierung sowie die daraus resultierende beschleunigte technologische Entwicklung bringen heute für die Industrieländer Herausforderungen im Hinblick auf Wachstum, Beschäftigung und Strukturwandel mit sich, denen nur mit einer entsprechenden Innovationsdynamik und -dichte begegnet werden kann. Grundvoraussetzung hierfür ist eine leistungsfähige Forschung und Entwicklung ebenso wie Wissens- und Technologietransfer zur Umsetzung von Forschungsergebnissen in marktfähige Produkte und Dienstleistungen. Europa hat sich im Rahmen des Lissabon-Prozesses zum Ziel gesetzt, den Anteil der Forschungsausgaben am Bruttoinlandsprodukt auf 3 % zu steigern. Um die Forschungsinfrastruktur in der Bundesrepublik zu stärken und global wettbewerbsfähig zu bleiben, hat die Bundesregierung mit der Hightech-Strategie 2025 einen weiteren wichtigen Schritt zur Förderung des wissenschaftlich-technischen Fortschritts in Deutschland getan.
Forschungsprogramme sind sowohl für Forschungseinrichtungen als auch für Mittelgeber ein wichtiges Instrument für die Darstellung und Steuerung ihrer Aktivitäten. Dies gilt auch für die Bundeseinrichtungen mit Forschungs- und Entwicklungsaufgaben, zu denen die Bundesanstalt für Materialforschung und -prüfung (BAM) zählt. Die BAM verfügt über einen klaren gesetzlichen Auftrag für die Sicherheit in Technik und Chemie. Ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Das Forschungsprogramm zeigt Perspektiven im Bereich ihres Aufgabenfeldes sowie ihrer damit verbundenen Forschungsaktivitäten transparent und politisch nutzbar auf und dient darüber hinaus der Koordinierung der Ressortforschung. Das Forschungsprogramm der BAM wird alle zwei Jahre aktualisiert. Es gibt einen Überblick über die aktuellen und zukünftigen Forschungsthemen und die hierfür erforderlichen Rahmenbedingungen.
Der Koalitionsvertrag der Bundesregierung betont in seiner Präambel zur Zukunft Deutschlands in Bezug auf die notwendige Modernisierung, dass „dieser Fortschritt auch mit einem Sicherheitsversprechen einhergehen muss“. Die Bundesanstalt für Materialforschung und -prüfung (BAM) stellt mit ihrem Auftrag „Sicherheit in Technik und Chemie“ und ihrer über 150-jährigen Kompetenz sicher, dass ein nachhaltiger technischer Fortschritt von einem Sicherheitsversprechen für die Bürger*innen begleitet ist.
Durch ihre Interdisziplinarität, die thematische Breite, die langjährige Erfahrung und die unabhängige Rolle als Ressortforschungseinrichtung ist die BAM in einer herausragenden Lage, als zentraler Akteur die Entwicklung unterschiedlichster Technologien unter Berücksichtigung sicherheitstechnischer Aspekte voranzubringen, das Vertrauen der Gesellschaft in diese Technologien sicherzustellen und dadurch die Basis für erfolgreiche Innovationen zu schaffen.
Der Fokus ihrer Arbeit liegt auf den fünf Themenfeldern Energie, Infrastruktur, Umwelt, Material und Analytical Sciences. Wichtige Themen betreffen dabei sowohl die Energiewende (Wasserstoff, elektrische Energiespeicher, Windenergie) als auch Bereiche der Technologiesouveränität wie die additive Fertigung, zuverlässige Materialdaten, Zustandsüberwachung und Kreislaufwirtschaft.
Die Digitalisierung und den digitalen Wandel unterstützt die BAM in Bezug auf technologieübergreifende Rahmenbedingungen besonders in der Initiative Qualitätsinfrastruktur-Digital (QI-Digital), in der gemeinsam mit weiteren zentralen Akteuren der deutschen QI Lösungen für die Qualitätssicherung in einer digitalisierten Welt entwickelt werden.
Grundvoraussetzung für sichere Technologien und Innovationen ist eine leistungsfähige Forschung und Entwicklung ebenso wie Wissens- und Technologietransfer zur Umsetzung von Forschungsergebnissen in marktfähige Produkte und Dienstleistungen. Dafür bildet die Arbeit der BAM eine wichtige Basis.
Ihre Forschung ist mit der Wahrnehmung öffentlicher Aufgaben verbunden. Das Forschungsprogramm zeigt Perspektiven im Bereich ihres Aufgabenfeldes sowie ihrer damit verbundenen Forschungsaktivitäten transparent und politisch nutzbar auf und dient darüber hinaus der Koordinierung der Ressortforschung.
Das Forschungsprogramm der BAM wird alle zwei Jahre aktualisiert. Es gibt einen Überblick über die aktuellen und zukünftigen Forschungsthemen und die hierfür erforderlichen Rahmenbedingungen.
Continuing progress in the field of X-ray scattering methods empowers scientists with new possibilities to capture the most important piece of information about the structure of the sample - its 3D electron density.
Although the first methods appeared almost a century ago, recovering the density structure of a sample is still very problematic. Most avail-able imaging techniques transform a 3D electron density of a realspace structure into the 2D Fourier Transform of the intensity of scattered waves in the reciprocal space. This process causes a loss of information.
Firstly, instead of a 3D sample, a 2D image is created, and secondly, the phase information of the scattered waves is lost. The latter is known as the ”phase problem” and poses a serious obstacle on a way to recover a 3D electron density. In this work, we draw attention to the problem of forward and inverse Small Angle X-Ray Scattering. In the first, forward, part, we rethink the existing pipelines to computationally simulate such scattering experiments. Although there are efficient implementations of fast Fourier transformation, they often have some drawbacks. For instance, to calculate a 3D fast Fourier transform it is required to place its density in the RAM. For high-resolution structures of size > 1024 3 , this becomes very problematic, as the whole density structure requires more than 16 GB of memory.
CUDA solution allows for a very fast and parallelizable implementation of high-resolution data on hundreds of last-generation machines.
Such computations are very pricy and inaccessible for most scientists.
To bypass this limitation, we propose a solution for a split-up 3D fast Fourier transform, which is implemented as a sequence of 2D and 1D operations. We compare our implementation on the simulated 3D shapes and show the result of a proof-of-concept on 4096 3 Metallorganic framework density structure. In the second, inverse problem, we train an invertible neural network, that given scattering data can predict the shape and its parameters. The architecture is built such, that the inverse problem is learned together with the forward process - the Fourier Transformation. We achieved very good results with this architecture, nonetheless, further testing is required, as the current training set only encompasses three simple shapes: sphere, hard sphere and cylinder.
All code to reproduce and analyze the results is available at https: //github.com/sofyalaski/SAXS-simulations.
The liaison report from the ISO Technical Committee ISO/TC 202 'Microbeam Analysis' for the November 2022 ISO/TC 229 Nanotechnologies Plenary Meeting Nanotechnologies Liaison Coordination Group (NLCG) is provided. Essential Information such as newly published standards and projects in develeopment relevant for ISO/TC 229 resulted from the progress within the last year and additional comments on behalf of ISO/TC 202 are included in the report.
Im Auftrag des Bundesministeriums für Wirtschaft und Klimaschutz haben DIN und DKE im Januar 2022 die Arbeiten an der zweiten Ausgabe der Deutschen Normungsroadmap Künstliche Intelligenz gestartet. In einem breiten Beteiligungsprozess und unter Mitwirkung von mehr als 570 Fachleuten aus Wirtschaft, Wissenschaft, öffentlicher Hand und Zivilgesellschaft wurde damit der strategische Fahrplan für die KI-Normung weiterentwickelt. Koordiniert und begleitet wurden diese Arbeiten von einer hochrangigen Koordinierungsgruppe für KI-Normung und -Konformität.
Mit der Normungsroadmap wird eine Maßnahme der KI-Strategie der Bundesregierung umgesetzt und damit ein wesentlicher Beitrag zur „KI – Made in Germany“ geleistet.
Die Normung ist Teil der KI-Strategie und ein strategisches Instrument zur Stärkung der Innovations- und Wettbewerbsfähigkeit der deutschen und europäischen Wirtschaft. Nicht zuletzt deshalb spielt sie im geplanten europäischen Rechtsrahmen für KI, dem Artificial Intelligence Act, eine besondere Rolle.
Quantitative 1H Nuclear Magnetic Resonance (qNMR) of Aromatic Amino Acids for Protein Quantification
(2022)
qNMR is a valuable technique for metrological studies due to the uniformity of its signal response for all chemical species of an isotope of interest, which enables compound-independent calibration. However, protein quantification remained challenging as large molecules produce wide, low-intensity signals that reduce the already low sensitivity. Combining qNMR with the hydrolysis of protein samples into amino acids circumvents many of these issues and facilitates the use of NMR spectroscopy for absolute protein and peptide quantification.In this work, different conditions have been tested for quantifying aromatic amino acids and proteins. First, we examined the pH-based signal shifts in the aromatic region. The preferable pH depends on the selection of the amino acids for quantification and which internal standard substance should be used to avoid peak overlap. Several aromatic compounds, such as terephthalic acid, sulfoisophthalic acid, and benzene tricarboxylic acid, have been applied as internal standards. The quantification of amino acids from an amino acid standard, as well as from a certified reference material (bovine serum albumin), was performed. Using the first two suggested internal standards, recovery was ~ 97 % for histidine, phenylalanine, and tyrosine at a concentration of approximately 1 mM in solution. Acidic hydrolysis of a certified reference material (CRM) of bovine serum albumin (BSA) and subsequent quantification of Phe and Tyr yielded recoveries of 98 ± 2 and 88 ± 4 %, respectively, at a protein concentration of 16 g/L or 250 µM.
This guideline was drafted following and complementing the norm ISO 22232-2:2020(E) to include air-coupled ultrasonic transducers. This document specifies the characteristics of probes used for non-destructive air-coupled ultrasonic testing with center frequencies above 20 kHz, with focusing or without focusing means.
„Getränkekühler optimal einsetzen“: So sparen Sie die Energiekosten und schonen das Klima.
Wussten Sie, dass Sie durch den Einsatz eines effizienten Getränkekühlers (Energieeffizienzklasse B) ca. 114 € pro Jahr sparen im Vergleich zu einem weniger effizienten Gerät (Energieeffizienzklasse D)? Aber nicht immer gibt es die Möglichkeit ein Neugerät anzuschaffen. Oft werden die Kühlgeräte von Getränkeherstellern zur Präsentation ihrer Waren zur Verfügung gestellt. Trotzdem tragen am Ende die Betreiber:innen die Betriebskosten der Geräte.
Aber auch beim Einsatz Ihres weniger effizienten Getränkekühler gibt es verschiedene Möglichkeiten, die Energiekosten zu senken. Beispielsweise kann schon der Einsatz einer Zeitschaltuhr zu einer Stromreduzierung von bis zu 50 Prozent oder auch die richtige Platzierung der Geräte an kühlen Orten ohne Zugluft zu einem geringeren Strombedarf von bis zu 30% führen.
In unserer Checkliste für die Aufstellung und das Betreiben von Getränkekühlgeräten zeigen wir Ihnen einfache Schritte, um den Energieverbrauch schnell zu senken.
Bei der Montage von Stahlkonstruktionen kommt es trotz anforderungsgerechter schweißtechnischer Fertigung vereinzelt zur Detektion von unzulässigen Unregelmäßigkeiten im Schweißbereich.
In einem Forschungsprojekt (FOSTA P1311) wurden Untersuchungen durchgeführt und Kenntnisse erarbeitet, um mittelfristig vor allem KMU beanspruchungsgerechte Reparaturkonzepte zur Verfügung zu stellen. Damit können letztlich Schäden und zumeist teure Nacharbeiten verhindert und eine verbesserte Ausnutzung des hohen Festigkeitspotentials hochfester Stähle erreicht werden. Gerade KMU können mit Blick auf die Kosten für Fertigung, Schweißarbeit und Material von den Erkenntnissen beim Einsatz hochfester Stähle, die für eine effiziente Realisierung der Energiewende in Deutschland notwendig sind, profitieren.
Nonporous corundum powder, known as an abrasive material in the industry, was functionalized covalently with protein binders to isolate and enrich specific proteins from complex matrices. The materials based on corundum were characterized by TEM, ESEM, BET, DLS, and zeta potential measurements. The strong Al-O-P bonds between the corundum surface and amino phosphonic acids are used to introduce functional groups for further conjugations. The common cross-linker glutaraldehyde was compared with a hyperbranched polyglycerol (PG) of around 10 kDa. The latter is oxidized with periodate to generate aldehyde groups that can covalently react with the amines of the surface and the amino groups from the protein via a reductive amination process. The amount of bound protein was quantified via aromatic amino acid analysis (AAAA). This work shows that oxidized polyglycerol can be used as an alternative to glutaraldehyde. With polyglycerol, more of the model protein bovine serum albumin (BSA) could be attached to the surface under the same conditions, and lower nonspecific binding (NSB) was observed. As a proof of concept, IgG was extracted with protein A from crude human plasma. The purity of the product was examined by SDS-PAGE. A binding capacity of 1.8 mg IgG per g of corundum powder was achieved. The advantages of corundum are the very low price, extremely high physical and chemical stability, pressure resistance, favorable binding kinetics, and flexible application.
In 2020, the European Commission has announced to propose a Sustainable Product Policy for the EU which shall ensure that the performance of front-runners in sustainability progressively becomes the norm. In addition, the European Commission has re-emphasised the necessity to significantly improve the effectiveness of the current Ecodesign framework for energy-related products.
With this paper, we present an initial outline of a policy approach which we call the “EU frontrunner approach”. The approach aims at installing a regulatory framework which enables a semi-automated, progressive adaptation of ecodesign minimum requirements for products. It builds on performance levels of the best products available on the market by aggregating information in a database.
The “front-runner approach” could first be applied to progressively adapt product-related minimum energy-efficiency requirements. This way it would serve as a starting point to introduce this conceptto the EU policy arena.
While the approach can be applied for energy efficiency, it is neither limited to energy-related products nor to energy-related requirements. It can be applied to the wide range of nonenergy related products within the scope of the upcoming Ecodesign for Sustainable Products Regulation (ESPR) as well as to non-energy-related requirements, such as minimum requirements for durability, reparability, recyclability and recycled content.
Exposure sites and outdoor exposure have always been a part of atmospheric corrosion research providing the “final answer”, although at the cost of long exposure times. Individual exposure programs such as ISOCORRAG, MICAT and ICP Materials have resulted in collaborative networks of exposure sites. So far, however, there has been no collective effort to put together currently active sites in a comprehensive manner and across programs and nations. The information collected in the catalogue is possible thanks to the work of all individual site managers listed as contact persons, efforts of members of Working Party 25 (WP25) Atmospheric Corrosion of the European Federation of Corrosion (EFC) and financial support of the EFC. With this Catalogue you can both get a general overview of what is available and be guided if you are looking for a particular environment with certain characteristics.
The OECD Working Party on Manufactured Nanomaterials (WPMN) has actively worked towards understanding possible safety issues for manufactured nanomaterials and has contributed significantly to resolving these by developing Test Guidelines, Guidance Documents, Test Reports and other publications with the aim of a safe use of manufactured nanomaterials. To address the specific needs of manufactured nanomaterials, the OECD Test Guideline No. 110 “Particle Size Distribution/Fibre Length and Diameter Distributions” was identified as one of the test guidelines (TGs) to require an update. The current TG 110 (adopted in 1981) is only valid for particles and fibres with sizes above 250 nm. The WPMN prioritised to either update TG 110 to be applicable also to particles at the nanoscale or draft a new nanomaterial specific (TG).
Eventually, it was decided to develop a new TG that covers the size range from 1 nm to 1000 nm, intended for particle size and particle size distribution measurements of nanomaterials. Paragraph 11 provides further justification on the need for such measurements for nanomaterials. This TG overlaps with TG 110 in the size range from 250 nm to 1000 nm. When measuring particulate or fibrous materials, the appropriate TG should be selected depending on the size range of particles tested. In line with TG 110, the new TG for nanomaterials includes separate parts for particles and fibres.
For the part of this TG which addresses particles, several methods applicable to nanomaterials were reviewed and included to take into account developments since 1981 when the TG 110 was adopted. This TG includes the following methods: Atomic Force Microscopy (AFM), Centrifugal Liquid Sedimentation (CLS)/Analytical Ultracentrifugation (AUC), Dynamic Light Scattering (DLS), Differential Mobility Analysis System (DMAS), (Nano)Particle Tracking Analysis (PTA/NTA), Small Angle X-Ray Scattering (SAXS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). The method Single Particle Inductively Coupled Plasma Mass Spectrometry (sp-ICP-MS) could not be sufficiently validated within the interlaboratory comparison (ILC) carried out for the different methods in this TG (see also paragraph 6 for further details on the ILC). Applicability of sp-ICP-MS is strongly limited to nanomaterials with high mass values in combination with a sufficiently high particle size. However, the general method ICP-MS is widely used and the sp-mode for the size measurement of specific nanomaterials was successfully performed in ILCs elsewhere. The method is therefore included in the Appendix Part C of this TG, which further details the limitations of sp-ICP-MS.
For measuring the diameter and length of fibres, analysing images captured with electron microscopy is currently the only method available. This TG includes Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM).
To test the validity of this TG, an ILC was performed. Test materials were chosen to reflect a broad range of nanomaterial classes, e.g. metals, metal oxides, polymers and carbon materials. Where possible, well-characterised test materials were used.
Additionally, the test materials were chosen to reflect a broad range of sizes representing the size range 1 nm to 1000 nm. Specifically for fibres, a broad range of aspect ratios was included (length/diameter of 3 to > 50). Some of the test materials used are commercially available and further references are given in the validation report of the ILC. Sample preparation for physical chemical characterisation is critical for all listed methods. Due to the differences between individual nanomaterials and due to the wide range of individual material properties it is impossible to have a generic protocol to obtain the best possible sample preparation for every nanomaterial. Therefore, a generic protocol on sample preparation is not part of this TG. Information on sample preparation is given in the paragraphs 25-29, 33, 34 and 39 for particles and in paragraphs 159) for fibres. Further information on sample preparation of nanomaterials for physical chemical characterisation can be found in the OECD Guidance on Sample Preparation and Dosimetry for the Safety Testing of Manufactured Nanomaterials and elsewhere.
Im Jahre 2011 wurde in Deutschland nach 50 Jahren der Ausstieg aus der kommerziellen Kernenergie beschlossen. Fünf Jahre später war Deutschland mit 80.000 GWh immer noch unter den zehn größten Atomstromproduzenten. Im darauffolgenden Jahr wurden weltweit 2.500.000 GWh Atomstrom produziert. Durch die Atomstromproduktion fallen große Mengen an radioaktiven Reststoffen an, die bis zu mehrere tausend Jahre für einen vollständigen Abbau benötigen. Aus dieser Problematik geht die Debatte über den Verbleib der Reststoffe hervor. Die Endlagerung in tiefen Gesteinsschichten ist eine Lösung für das Problem. Voraussetzung ist hierbei allerdings die Gewährleistung eines dauerhaften Schutzes vor ionisierender Strahlung, die durch Verschlüsse der tiefen Gesteinsschichten in Form von Verschlussbauwerken erzielt werden sollen. Es gilt die bauliche Integrität sowie die Dichtwirkung der Verschlussbauwerke dauerhaft zu überwachen und zu prüfen, um eine langfristige Verzögerung der Radionuklidfreisetzung zu gewährleisten.
Dieses Wissensdokument führt zu den Vertragstexten der früheren ZTV BEL-FÜ (ZTV-ING 8-2) und heutigen ZTV-ING Teil 6 Abschnitt 7 aus und erläutert die „Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Ingenieurbauten, Teil 6: Bauwerksausstattung, Abschnitt 7: Fahrbahnübergänge aus Asphalt“. Dabei geht es insbesondere um Fugen von Ingenieurbauwerken des Verkehrswegebaus, die quer oder in einem bestimmten Winkel zur Fahrbahn verlaufen und befahren werden. Diese Fugen müssen deshalb einerseits in fahrtechnischem Sinne verschlossen werden, damit die Fahrzeuge den Spalt störungsfrei und verkehrssicher überqueren können. Andererseits ist ein Fugenverschluss zum Schutz des Tragwerks vor Feuchte- oder Schadstoffbeanspruchung (Korrosionsgefahr) erforderlich. Je nach Größe des Fugenspaltes und der auftretenden Bewegungen müssen die Fugenfüllungen unterschiedlich ausgebildet werden, um die überquerenden Lasten sicher in das Tragwerk abzuleiten. Bauteile oder Konstruktionen, die diese verkehrstechnische Aufgabe übernehmen, werden allgemein als Fahrbahnübergänge bezeichnet.
Die H ZTV-ING 6-7 ersetzen die „Hinweise und Erläuterungen zu den Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für die Herstellung von Fahrbahnübergängen aus Asphalt in Belägen auf Brücken und anderen Ingenieurbauwerken aus Beton“, Ausgabe 2001.
Die Überarbeitung der „Hinweise und Erläuterungen“ wurde aufgrund der Überarbeitung der ZTV-ING 6-7 erforderlich. Außerdem wurden in den Hinweisen neue Entwicklungen in den Bereichen der Fahrbahnübergänge aus Asphalt mit größeren Einbaubreiten und dehnungsverteilenden Einbauten, der Belagsdehnfugen sowie des Oberflächenabschlusses mit GFK-Platten berücksichtigt.
Die Forschungsgesellschaft für Straßen- und Verkehrswesen hat den „Abschnitt 1: Brückenbeläge auf Beton mit einer Dichtungsschicht aus einer Polymerbitumen-Schweißbahn“ zu dem Teil 7: „Brückenbeläge“ der ZTV-ING überarbeitet und neu herausgegeben. Die Neuausgabe berücksichtigt die aktuellen Anforderungen durch die Europäische Normung bezüglich der Polymerbitumen-Schweißbahnen. Weitere Änderungen zur Vorgängerausgabe von 2003 wurden notwendig durch die Neuauflagen weiterer FGSV-Regelwerke, insbesondere der TL Bitumen-StB (FGSV 794), der ZTV Fug-StB (FGSV 897/1), der TL Fug-StB (FGSV 897/2), der TP Asphalt-StB (FGSV 756) und der E KvB (FGSV 727).
Die ZTV-ING Teil 7 Abschnitt 1 führt insbesondere aus zu den Grundlagen des Brückenbelages, zur Ausführung und Qualitätssicherung sowie zur Herstellung unmittelbar auf Trog- und Tunnelsohlen aus Beton.
Der Anhang enthält die „Vorgaben für die Prüfungen während der Bauausführung“ sowie das Formblatt „Protokoll über die Entnahme von Rückstellproben“ und eine tabellarische Zusammenstellung über „Art und Umfang sowie Anforderungen und Toleranzen für die Baustoffeinangsprüfungen“. Das Bundesverkehrsministerium hat mit seinem ARS 23/2021 zur Fortschreibung der ZTV-ING die Neuausgabe der Teils 7 Abschnitt 1 bekannt gemacht.
Die „Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Ingenieurbauten, Teil 7: Brückenbeläge, Abschnitt 1: Brückenbeläge auf Beton mit einer Dichtungsschicht aus einer Polymerbitumen-Schweißbahn“, Ausgabe 2021 ersetzen die „Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Ingenieurbauten, Teil 7: Brückenbeläge, Abschnitt 1: Brückenbeläge auf Beton mit einer Dichtungsschicht aus einer Bitumen-Schweißbahn“, Ausgabe 2003.
Die "Technischen Prüfvorschriften für die Dichtungsschicht aus einer Polymerbitumen-Schweißbahn zur Herstellung von Brückenbelägen auf Beton" (TP BEL-B 1) enthalten alle notwendigen Angaben zur Durchführung der nach den "Technischen Lieferbedingungen für die Dichtungsschicht aus einer Polymerbitumen-Schweißbahn zur Herstellung von Brückenbelägen auf Beton" (TL BEL-B 1) geforderten Prüfungen. Art und Umfang der Einzelprüfungen sowie die entsprechenden Anforderungen sind den zugehörigen TL BEL-B 1 zu entnehmen.
In den "Technischen Lieferbedingungen für die Dichtungsschicht aus einer Polymerbitumen-Schweißbahn zur Herstellung von Brückenbelägen auf Beton" (TL BEL-B 1) sind die Regelungen über die erforderlichen Voraussetzungen zur Verwendung von Polymerbitumen-Schweißbahnen zur Ausbildung einer Dichtungsschicht aus einer einlagigen Polymerbitumen-Schweißbahn auf Beton aufgeführt. Sie umfassen den grundsätzlichen Nachweis der Funktionsfähigkeit und Dauerhaftigkeit sowie die Sicherstellung des nachgewiesenen Qualitätsniveaus.
Es wurde im Rahmen dieser Arbeit eine neue Methode der Biokonjugation entwickelt, die es ermöglicht humane Antikörper ortspezifisch mit IgG-bindenden Peptiden zu konjugieren. Als Basis fungierte ein Peptid, welches für den Einsatz gezielt modifiziert wurde. So sollte am C-Terminus ein Biotin eingefügt werden, dass für die spätere Detektion der Biokonjugation genutzt werden kann, während am N-Terminus ein Cross-Linker für die kovalente Bindung zum Antikörper eingefügt wurde. Das Biotin wurde mittels Biotin-Lysin eingebaut. Dies hat den Vorteil, dass die modifizierte Aminosäure direkt in der SPPS genutzt werden kann. Auch der Cross-Linker soll schon während der SPPS in das Peptid integriert werden. Als Cross Linker wurden die zwei heterobifunktionellen Succinimidyl(3-bromoacetamid)propionate und Succinimidyl(4-iodacetyl)aminobenzoat untersucht. Die Aktivierung des Peptides mit dem SBAP-Cross-Linker erfolgte am besten im pH-Bereich zwischen 7,0 und 9,0. Die Modifizierung des Peptides mit dem Iodid-Cross-Linker SIAB unter den gleichen Bedingungen zeigte allerdings keine zufriedenstellenden Ergebnisse. Da das erste Peptid allerdings in den Folgeexperimenten sehr gute Ergebnisse zeigte, musste kein weiterer Linker getestet werden. Zusätzlich zu der Cross-Linker-Wahl sollte der Abstand zwischen dem Cross-Linker und dem Grundgerüst des Peptides auf den Einfluss der Bindung untersucht werden. Dazu wurden drei Kontrollpeptide synthetisiert, die entweder um zwei Aminosäuren zwischen dem ursprünglichen N-Terminus des Peptides und dem SBAP-Linker verlängert wurden, keinen SBAP-Linker beinhalten oder die Verlängerung ohne SBAP-Linker besaßen. Die erfolgreiche Synthese aller vier Peptide wurde mittels MALDI-TOF-MS bestätigt.
Die neue Crosslinking-Methode ist hilfreich, um Immunglobuline des Isotyps G ortspezifisch an ihrer Bindungsstelle mit Protein A oder G zu konjugieren. Die Kopplungen von Protein A und G konnten erfolgreich an Maus- und Human-IgG durchgeführt, sowie die Bedingungen untersucht und optimiert werden. Die Aktivierung von Protein G mit Glutaraldehyd erfolgt am besten bei pH 8 und die anschließende Kopplung mit Maus-IgG1 bei einem pH-Wert von 6. Jedoch wurden mit SIAB und Sulfo-SIAB als Crosslinker im Vergleich zu Glutaraldehyd noch höhere Signale erhalten. Für die Kopplung von SIAB sind 40% DMSO im Reaktionspuffer günstig, währenddessen Sulfo-SIAB gut wasserlöslich ist daher keine Lösungsvermittler benötigt. Es ergab sich ein optimaler pH-Wert von 7,4 um Protein A mit SIAB zu aktivieren und den gleichen pH-Wert um die Kopplung mit Maus-IgG1 durchzuführen. Für die Kopplung von Protein G mit Maus-IgG1 hingegen zeigten die Experimente, dass ein leicht saurer pH-Wert bei pH 6 für den IgG-Kopplungsschritt am günstigsten ist. Während die Inkubationszeit von Maus-IgG1 mit Protein G bei 16 h liegt, muss mit Protein A bis zu 40 h inkubiert werden, um das Kopplungsmaximum zu erreichen. Des Weiteren wurde das Crosslinking von Human-IgG (Herceptin) mit SIAB untersucht. Dabei zeigte sich, wie in der Abbildung 47 zu sehen ist, dass Protein A und G vergleichbar gut an Human-IgG zu koppeln sind. Für das Crosslinking von Protein G mit Maus-IgG1 ist dagegen ein deutlich besserer Umsatz im Vergleich zu Protein A zu erkennen (Abbildung 48). Heterobifunktionale Linker können mit der reaktiveren Gruppe die erste Bindung eingehen, um erst nach Zugabe eines weiteren Reagenzes die zweite Bindung auszubilden und zudem intramolekulare Reaktionen möglichst zu vermeiden.
Das Ziel der Arbeit war die Entwicklung einer magnetischen Anreicherungsmethode für eine Bead-basierte Substanzbibliothek zur Identifizierung von Proteinbindern. Im Ramen des Forschungsbelegs wurde bereits eine Anreicherungsmethode für ein Modellsystem einer Peptidbibliothek entwickelt. Das Modellsystem bestand dabei aus zwei verschiedenen Peptiden. Als Positivkontrolle wurde das FLAG-Peptid gewählt, welches selektiv gegen den Anti-FLAG-Antikörper bindet, und ein weiteres Peptid wurde als Negativkontrolle gewählt. Anhand dieses Modellsystems konnte die zuvor entwickelte Anreicherungsmethode von 20.000 auf 1.000.000 Beads vergrößert werden. Hierbei wurde ein Anreicherungsfaktor von 818 und eine gute Wiederfindungsrate von 82% erreicht.
Ausgehend von dem in der Literatur beschriebenen Verfahren zur Bestimmung aromatischer Aminosäuren konnte eine Analysemethode zur Proteinbestimmung über die optische Detektion von Tyrosin und Phenylalanin nach chromatographischer Trennung der Protein-Hydrolysate entwickelt werden, die gegenüber dem Verfahren aus der Literatur erhebliche Vorteile besitzt. Der Einsatz von Rundbodenvials stellt eine Neuerung und kostengünstige Alternative zu der konventionellen Hydrolyse in Vakuumhydrolyseröhrchen wie auch zu den Mikrowellenvials der Mikrowellenhydrolyse dar, die das Potential für Miniaturisierungen der Proben hat und sich zudem für große Probendurchsätze eignet. Anstelle der Mikrowellenheizungen wurde ein konventionelles Ölbad als Heizquelle verwendet. Somit ergibt sich eine Verbesserung auch darin, dass diese Methode geringere Geräteinvestitionen erfordert. Wie die Ergebnisse nahelegen, sind sowohl Salzsäure als auch Bromwasserstoffsäure geeignete Reagenzien, die bei der sauren Hydrolyse von Proteinen verwendet werden können. Mit Hilfe antioxidativer Zusätze können Nebenreaktionen erfolgreich vermieden werden. Hier haben sich L-Cystein und Oxalsäure als wirkungsvolle Additive herausgestellt. Wichtige Verbesserungen betreffen vor allem die Zeitersparnis bei der Hydrolyse, die Aufarbeitung der Hydrolysate und die chromatographischen Separationen. Erstere konnte gegenüber der konventionellen Methode von 22 Stunden auf 45 Minuten reduziert werden. Die chromatographische Trennung wurde so weit optimiert, dass die Laufzeit von 64 auf 35 Minuten verkürzt werden konnte. Zudem konnte auf das zeitraubende und kontaminationsanfällige Eindampfen der Hydrolysate verzichtet werden. Während der Aufarbeitung der Hydrolysate konnten die Menge eingesetzter Chemikalien reduziert und damit mögliche Störungen während der optischen Detektion verringert werden. Letztere wurde zum einen durch das Einbeziehen der UV-Absorption bei 260 nm erweitert, sodass eine Alternative zur Absorption bei 215 nm vorliegt, die ebenere Basislinien im Chromatogramm ermöglicht. Zum anderen wurde gezeigt, dass mit Hilfe der Fluoreszenz die Empfindlichkeit der Methode gegenüber der UV-Absorption erheblich verbessert werden kann. Anhand der Probe eines Birkenpollenextraktes ließ sich die Anwendbarkeit der optimierten Methode auf Realproben demonstrieren.
In this thesis a protocol based on a direct competitive and non-competitive immunoassay using the microarray format was developed to screen emulated hybridoma supernatants against the drug carbamazepine (CBZ). As support, epoxy slides were manufactured by coating microscope glass slides with epoxy silanes. The manufactured epoxy slides showed similar capacity for protein immobilization as commercially available NEXTERION slides, but showed a higher autofluorescence background. On the epoxy slides, protein A, Cys-A, G and Cys-G were immobilized as antibody capturing coating. It could be shown that the Cys-tag considerably increased the immobilization of all compared proteins, especially of protein G. Protein Cys-G immobilized at pH 8-9 was considered the most suitable protein for antibody immobilization due to good spot uniformity and a high binding capacity for IgG. Additionally, in immobilization experiments it could be shown, that 10-500 fold excess of bovine IgG, introduced by two different fetal bovine serum (FBS) products, showed no significant competition on the immobilization of mice or goat IgG on protein Cys-G. To examine the captured antibodies for affinity to CBZ, the CBZ-TOTA-DY654 tracer was custom synthesized. It could be demonstrated, that the tracer antibody interaction was competitive with the tracer precursor, CBZ-TOTA-NH2 and CBZ. Furthermore, the synthesized tracer was also successfully used by externals to evaluate CBZ affine hybriodoma cells in flow cytometry. In the simulated screening, five antibodies with known affinity to CBZ were diluted in a cell culture medium. The screening method allowed to differentiate between affine antibodies (IC50 < 20 µg/ml) and unaffine antibodies (IC50 > 20 µg/ml), when concentrations of 0.1 µg/ml IgG or greater have been used. Of five applied antibodies, all highly affine clones (CE2 and B3212M) were reported as positives while no false-positive samples were observed. The screening included competitive, with around 89500 fold excess of CBZ, and non-competitive tracer incubation on different segments of the same chip, which resulted in total signal suppression on the competitive segment. The screening was performed in 20 hours, only a few nanoliters, of each simulated supernatant, were consumed in the screening process, furthermore in the method standard 96 well MTPs were used and no cleanroom facilities were required.
Ziel dieser Arbeit war die Entwicklung einer Methode zur Hochdurchsatzanalyse von partikelgebundenen Split-and-Mix-Peptidbibliotheken. Dabei wurde ein System entwickelt, das Partikelbibliotheken in kurzer Zeit auf ihre Bindung zu einem Zielmolekül hin untersucht und im nächsten Schritt eine direkte „Ein-Partikel“-Sequenzierung der Peptide von der festen Phase ermöglicht. Die Analyse der Bindung eines Zielmoleküls an ein selektiv bindendes Peptid wurde dabei in einem Modellsystem simuliert. Dazu wurde FITC-markiertes Neutravidin 3 mit festphasengebundenen biotinylierten und nicht-biotinylierten Peptiden inkubiert. Die Bindung von Neutravidin-FITC an die biotinylierten Peptide konnte erfolgreich mittels eines Fluoreszenzmikroskops nachgewiesen werden, wobei diese Methode für eine Hochdurchsatzanalyse ungeeignet war. So wurde die Analyse des Fluoreszenzassays auf einen Microarrayscanner übertragen (siehe Abbildung 33). Dies gelang erfolgreich wobei die hohe Eigenfluoreszenz des Tentagel-Harzes zu falsch positiven Ergebnissen führte. Mit einem Wechsel zum längerwelligen Fluoreszenzfarbstoff ATTO-633 konnten falsch positive Ergebnisse vermieden werden. Somit wurde die zeitintensive Fluoreszenzanalyse von einem Fluoreszenzmikroskop erfolgreich auf einen Microarrayscanner übertragen, welcher in kurzer Zeit (ca. 5 min pro Objektträger) eine Vielzahl an peptidbeladenen Partikeln gleichzeitig analysieren kann.
Im Vergleich zu anderen Proteinen ist die Identifizierung von Antikörpern anhand ihrer Sequenz zum Beispiel mittels "peptide mass fingerprinting" schwierig. Da die Sequenzinformation eines Antikörpers aufgrund der hypersomatischen Mutation während der Affinitätsreifung nicht im Genom eines Organismus gespeichert ist, kann die Aminosäuresequenz nicht auf einfachem Weg der DNA-Sequenzierung gewonnen werden. Das ist nur in seltenen Fällen möglich, wenn dem Endanwender der Zellklon der Antikörper-produzierenden Zelle zugänglich ist. Eine Sequenzierung auf Protein-Ebene ist sehr aufwändig und teuer und wird daher fast nie für die Charakterisierung von analytischen Antikörpern verwendet. Der Mangel an Validierung dieser analytischen Antikörper, die bei Experimenten verwendeten werden, löst aber eine Reihe Probleme aus, die die Wiederholbarkeit dieser Experimente schwierig und in einigen Fällen unmöglich macht. Das sorgt jährlich für verschwendete Forschungsgelder in Milliardenhöhe und hindert den wissenschaftlichen Fortschritt.
Ziel der vorliegenden Arbeit war die Entwicklung einer einfachen und schnellen Methode, die es trotzdem ermöglicht, die Identifikation von Antikörpern sicherzustellen. Dazu wurde eine Methode basierend auf dem "peptide mass fingerprinting" gewählt. Das Problem der unbekannten Aminosäuresequenz der Antikörper wurde gelöst, indem lediglich die Peptidmuster der entstehenden Fingerprint-Spektren zur Identifikation herangezogen wurden. MALDI wurde dabei als Ionisationsmethode für die Massenspektrometrie gewählt, da die resultierenden Spektren im Gegensatz zu ESI-MS einfach auszuwerten sind. Auch kann auf eine vorige Trennung der Peptide mittels LC verzichtet werden, was zusätzlich Analysenzeit spart. Für die Proteinspaltung wurde eine simple saure Hydrolyse mittels Ameisensäure gewählt. Im Vergleich zum herkömmlichen Trypsin-Verdau konnten auf zeitraubende Arbeitsschritte wie Denaturierung, Reduktion und Alkylierung der Antikörper verzichtet werden. Die Hydrolyse mittels Ameisensäure wurde bisher nur auf kleine und mittelgroße Proteine angewendet, sodass im ersten Teil dieser Arbeit mehrere Schritte optimiert wurden bevor zufriedenstellende Fingerprint-Spektren von Antikörpern erhalten wurden.
In dieser Arbeit wurden drei verschiedene Nanomaterialien auf ihre Bindungsfähigkeit zu Proteinen untersucht. Zu Beginn standen dabei die Herstellung stabiler Dispersionen der einzelnen Nanopartikel und die Stabilität der gebildeten Konjugate im Vordergrund. Der Nachweis einer erfolgreichen Konjugatbildung, sprich der Beschichtung von Nanopartikel mit Proteinen, wurde sowohl qualitativ mittels DLS-Messungen als auch über quantitative Protein-Bestimmungen erbracht. Für die Quantifizierung konnten verschiedene Methoden eingesetzt werden. Neben der klassischen Vorgehensweise, welche indirekt über die Quantifizierung von ungebundenem Protein im Überstand erfolgt, konnten ihm Rahmen dieser Arbeit verschiedene direkte Bestimmungsmethoden entwickelt werden. So wurden mittels kolorimetrischer Tests, wie dem BCA-Assay und dem Bradford-Assay, Nanodiamantdispersionen mit Hilfe einer Korrekturwellenlänge vermessen und quantifiziert. Ebenso zum Einsatz kam die Methode der Aminosäureanalytik, welche aufgrund ihrer guten Rückführbarkeit auf Aminosäurestandards Ergebnisse mit hoher Richtigkeit generieren kann und ebenso die Detektion kleiner Proteinmengen möglich macht.
Nach den erfolgten quantitativen Betrachtungen wurden die Protein-beschichteten Nanopartikel auf ihre Anwendbarkeit als Analoga von Virus-like Particles (VLP) bei einer Immunisierung zur Gewinnung von polyklonalen Antikörpern gegen humanes Ceruloplasmin in Kaninchen überprüft. Es konnte mittels ELISA gezeigt werden, dass die Konjugate erfolgreich für die Herstellung von Antikörpern eingesetzt werden können und im zeitlichen Verlauf einer Immunisierung eine Steigerung des Antikörper-Titers zu erreichen ist.
Vergleichende Darstellung SARS-CoV-2-spezifischer Nanobodys aus unterschiedlichen Wirtsorganismen
(2021)
Aufgrund der anhaltenden COVID-19-Pandemie werden neutralisierende Therapeutika benötigt. Eine Möglichkeit zur Behandlung stellt die Verwendung monoklonaler Anti-SARS-CoV-2-Immun-globuline dar. Ihre Produktion in Säugetierzellen ist jedoch schwer skalierbar, um den weltweiten Bedarf zu decken. VHH-Antikörper, auch Nanobodys genannt, bieten hierfür eine Alternative, da sie eine hohe Temperaturstabilität aufweisen und eine kostengünstige Produktion in prokaryotischen Wirtsorganismen ermöglichen.
The aim of this work was the preparation of a novel stationary monolithic phase for affinity chromatography and HPLC-applications. Therefore, we have chosen porous glass filters that are available with different pore sizes as raw materials to prepare monolithic columns. We purchased VitraPOR 4 (10-16 μm pore size) and VitraPOR 5 (1.0-1.6 μm pore size) monolithic glass filters. The physical properties of these glass filters were characterized. The surface area, pore size distribution and the porosity were determined using mercury intrusion porosimetry and BET. These glass filters only exhibit flow through pores and therefore show no bimodal pore size distribution in the mercury intrusion curves. Due to their low permeability, the applied filters that exhibit an inner diameter of 8.0 mm and a length of 15.0±0.1 mm could be operated at flow rates more than 10 ml/min. High flow rates are favorable for fast separation experiments.
In 2019 over 30 000 people were killed or injured by explosions caused by explosives like TNT, PETN, HMX and RDX. Therefore, highly sensitive assays for the detection of TNT are needed. In this study we compared two commercially available TNT antibodies: A1.1.1 and EW75C with a highly optimized indirect competitive ELISA based on a BSA-TNA conjugate. As a result, a precision profile for both antibodies was determined with a LOD of 170 pmol L-1 for the clone A1.1.1 and a LOD of 3,2 nmol L-1 for the clone EW75C. The measurements showed that the clone A1.1.1 is a highly sensitive antibody for the detection of TNT while the clone EW75C does show medium performance at most.
In the cross-reactivity characterization of both antibodies many substances, closely related to the structure of TNT were tested. Both antibodies showed strong cross reactivity with trinitroaniline and trinitrobenzene. For the clone A1.1.1, which is known to originate from immunization of mice with an TNP-glycine-KLH conjugate, this has to be expected. Interestingly the clone EW75C, which was not characterized yet, showed similar behavior. This suggests a TNA-conjugate as immunogen for the EW75C antibody as well. None of both antibodies showed cross-reactions to the high explosives PETN, HMX and RDX. Also, the cross-reactions of nitro musks with the antibodies were investigated. Despite their prohibition, nitro musks are still used in Asia especially and are particularly popular in India. The overall superior clone A1.1.1 showed a significant cross-reactivity to musk ambrette. For practical reasons the influence of musk ambrette on this assay when used in natural environment should be investigated.
In further experiments, the highly sensitive TNT antibody A1.1.1 was digested with papain to obtain monovalent Fab-fragments. Due to its high stability against the digestion, a custom protocol for the IgG1 subclass of mice, to which the clone A1.1.1 belongs, was developed, resulting in a quantitative digestion of the intact antibody to Fab fragments. The success of the digestion was determined with MALDI-TOF-MS and SDS-PAGE. It was shown that this protocol worked for many different antibodies of IgG1 subclass as well.
Das Ziel dieser Arbeit war es, die Vernetzung (Crosslinking) zwischen Protein G und einem Antikörper so durchzuführen, dass es zu keiner Modifikation der Antigen-Bindungsstelle des Antikörpers kommt. Zudem wurde im Rahmen dieser Arbeit ein Immunoassay entwickelt, mithilfe dessen zwanzig verschiedene Crosslinker in Hinblick auf ihre Fähigkeit Protein G zu funktionalisieren, untersucht werden konnten. Es konnten fünf Reagenzien identifiziert werden, die eine Derivatisierung von Protein G sowie eine anschließende Immobilisierung des Antikörpers auf dem Protein ermöglichen. Des Weiteren wurde gezeigt, dass mithilfe dieses Verfahrens sowohl die Immunpräzipitation als auch die massenspektrometrische Identifizierung und Charakterisierung von Proteinkomplexen erleichtert und verbessert werden kann.
Protein immobilization for the functionalization of particles is used in various applications, including biosensors, lateral-flow immunoassays (LFIA), bead-based assays, and others. Common methods for the quantification of bound protein are measuring protein in the supernatant before and after coating and calculating the difference. This popular approach has the potential for a significant overestimation of the amount of immobilized protein since layers not directly bound to the surface (soft protein corona) are usually lost during washing and handling. Only the layer directly bound to the surface (hard corona) can be used in subsequent assays. A simplified amino acid analysis method based on acidic hydrolysis and RP-HPLC-FLD of tyrosine and phenylalanine (aromatic amino acid analysis, AAAA) is proposed to directly quantify protein bound to the surface of gold nano- and latex microparticles. The results are compared with indirect methods such as colorimetric protein assays, such as Bradford, bicinchoninic acid (BCA), as well as AAAA of the supernatant. For both particle types, these indirect quantification techniques show a protein overestimation of up to 1700% compared to the direct AAAA measurements. In addition, protein coating on latex particles was performed both passively through adsorption and covalently through EDC/sulfo-NHS chemistry. Our results showed no difference between the immobilization methodologies. This finding suggests that usual protein determination methods are no unambiguous proof of a covalent conjugation on particles or beads.
MALDI-TOF-MS-based identification of monoclonal murine anti-SARS-CoV-2 antibodies within one hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used thirty-five monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied onto the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 45 minutes and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 °C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0 (https://gets.shinyapps.io/ABID/). This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
Development of an affinity-based method for the site-selective synthesis of antibody-drug-conjugates
(2021)
For the site-selective synthesis of ADCs, a variety of obstacles must be overcome. Those include designing bifunctional affinity peptides with reasonably low 𝐾𝑑-values that couple to the mAb in a site-selective manner. These peptides should also include a functional group that links the payload to the mAb under mild conditions without adversely affecting it. The bioconjugation between peptide and antibody and the linker between peptide and payload must be stable and durable to provide safety when used for medical purposes. The usage of metals and organic solvents should be minimized. Within the project, new types of functionalized affinity peptides were designed, and their affinity towards the Fc-fragment was determined.
Die Autoren zeigen dazu die gesetzlichen und energiepolitischen Rahmenbedingungen und Perspektiven auf, widmen sich in aktuellen Beiträgen zur Verfahrenstechnik der thermischen Abfallbehandlung sowohl den thermischen Hauptverfahren als auch der Abgasreinigung und gehen auf das Thema Wertstoffrückgewinnung ein. Ihr Fazit: Durch Anstrengungen, das stoffliche Recycling weiter zu optimieren, können künftig weitere Kreisläufe von Produkten und Materialien hochwertig geschlossen werden. Für manche Abfallströme wird dies aber aus verschiedenen Gründen nicht möglich sein – hier bleibt die thermische Abfallbehandlung unverzichtbar.
In der Masterarbeit wurde ein Screening gegen den CCMV mit einer linearen Peptidbibliothek entwickelt, wobei zwei lineare Binder identifiziert wurden. Das resynthetisierte Peptid wurde auf seine Bindungseigenschaften mittels ELISA und MST untersucht. Aufgrund eines Aminosäurefehlers in der selbst durchgeführten Resynthese des Peptids sind die Ergebnisse nicht vollständig übertragbar. Um eine umsetzbare Cyclusgröße für die Peptidbibliothek zu finden, wurden Ringgrößen mit sechs bis acht Aminosäuren untersucht. Da keiner der gewählten Ringgrößen bevorzugt war, wurde die Ringgröße aus acht Aminosäuren für die Peptidbibliothek gewählt. Der Ringschluss wurde durch die Bildung einer Disulfidbrücke erreicht. Dadurch war die Alkylierung der vorhandenen Thiolgruppe in den Abbruchsequenzen notwendig.
Neben den etablierten Alkylierungsreagenzien Iodessigsäure, Iodacetamid und Acrylamid wurden zwei Epoxide mituntersucht. Hierbei konnte nur bei Acrylamid und Propylenoxid eine vollständige Alkylierung beobachtet werden. Eine synthetische Peptidbibliothek aus zehn Aminosäuren pro Kopplungsschritt und einer Peptidlänge von acht Aminosäuren wurde erfolgreich nach der Split-and-Mix-Synthese hergestellt. Neben den kanonischen Aminosäuren wurde die synthetische Aminosäure 3-(3-Pyridyl)-alanin in die Peptidbibliothek mit eingebaut. Peptidsequenzen aus der cyclische Peptidbibliothek konnte mittels MALDI-TOF-MS identifiziert werden. Es konnte außerdem gezeigt werden, dass synthetische Aminosäuren mit proteinogenen Aminosäuren erfolgreich übersetzt werden. Anschließend wurde das entwickelte Screening auf eine cyclische Peptidbibliothek übertragen. Dabei konnte kein Binder identifiziert werden, da zu viele Nebenreaktionen auftraten. Ein alternativer Ringschluss über die Seitenketten von Lysin und Cystein wurden mit ortho-Phthaldialdehyd und 2,4,6-Trichloro-1,3,5-triazin (Cyanurchlorid) untersucht. Beide Bedingungen wiesen keinen erfolgreichen Ringschluss auf. Obwohl der Ringschluss über die Seitenketten von Lysin und Cystein nicht erfolgreich war, sollte ein Austausch von Cystein angestrebt werden, so dass kein freies Cystein in den Abbruchsequenzen vorhanden ist und die Alkylierung überflüssig wäre. Der Ringschluss durch Verwendung anderer Seitenketten bietet einen vielseitigen Ansatz.
Die zielgerichtete Weiterentwicklung von Bauteilen und Konstruktionselementen im Straßenbau hochbeanspruchter Verkehrswege unserer Infrastruktur (Bundesfernstraßen) erfordert spezielle, bauteiladaptierte technische Möglichkeiten/Sensorik zur Quantifizierung des Gebrauchsverhaltens. Bei Fugen in Verkehrsflächen stellen insbesondere langsam und schnell ablaufende Plattendeformationen infolge jahreszeitlicher und verkehrlicher Beanspruchungen maßgebende Beanspruchungszustände dar. Eine Quantifizierung dieser Einwirkungen hilft bei der Weiterentwicklung sowie auch bei der Bewertung optimierter technischer Lösungen. In Forschung kompakt 17/21 „Innovative Sensorik für Fugensysteme“ wird eine neuartige, robuste Lösung der BAM zur Datenerfassung und Bauwerksmonitoring von hochbeanspruchten Verkehrsflächen aus Beton vorgestellt.
Many studies have already shown that viruses can spread via aerosol particles. An aerosol is a mixture of air with solid or liquid particles dispersed in it. To understand the role of aerosol particles as a transmission path of SARS-CoV-2, knowledge of the different processes in an Aerosol is therefore of particular importance. With this paper, GAeF would like to contribute to a better understanding of the term “aerosol” and the relevant aerosol processes. In the context of this paper only the essential basics will be discussed. For a deeper understanding of the partly complex processes, please refer to the literature mentioned at the end of the paper.
The paper summarises a large number of studies on the formation of virus-laden aerosol particles and their spread. Based on this, it can be concluded that exhaled aerosol particles may play a prominent role in the spread of viruses in the corona pandemic. Finally, this paper discusses possible measures to reduce the spread of aerosol particles. The measures discussed are based on the current public debate including ventilation, air purifiers, HVAC systems and masks. Advice is given on the correct and sensible use of these measures.
An aerosol is always dynamic, as particles are newly formed, transported in or with the air, removed from the air or change in the airborne state. Aerosol particles have sizes between approx. 0.001 and several 100 micrometres (and not < 5 μm as currently defined in many publications) and spread relatively quickly with air currents, even over longer distances. Larger aerosol particles sink to the ground, depending on their size and density, while small aerosol particles can remain in the air for a very long time (see Section 3). Every person emits liquid aerosol particles of various sizes through breathing and when speaking, coughing and sneezing (see Section 4). If a person is infected with a virus, such as SARS-CoV-2, these aerosol particles can contain viruses that can be released into the air and inhaled by other people. SARS-CoV-2 has a size of 0.06 to 0.14 micrometres, but the exhaled liquid aerosol particles are larger. The liquid aerosol particles can shrink by evaporation, depending on the ambient conditions (see Section 3.3). Particle size is relevant for particle transport and particle separation. The highest risk of infection exists in closed indoor spaces, as aerosol particles can accumulate there.
Here in particular, appropriate measures must be taken to reduce the concentration of aerosol particles (see Section 5).
Against the background of aerosol science, the GAeF classifies the current measures to contain the pandemic as follows:
• In principle, no measure can work on its own! According to the current state of knowledge, the interaction of the most varied measures is the best way to minimise the risk of infection.
• Keeping distance is important, because with increasing distance, directly exhaled viruses are diluted and the probability of infection decreases. The often prescribed minimum distance can be used as a guide, but it should be increased and supplemented by other measures (see below), especially for longer meetings and also indoors with reduced air movement.
• Masks help to filter some of the exhaled particles (and viruses). This reduces the concentration of exhaled particles (and viruses) in a room and thus the risk of infection. It should be noted here that the exhaled aerosol particles are relatively large due to adhering moisture and can therefore also be efficiently retained by simple masks. However, since these particles shrink with longer dwell time in the room air, simple mouth-nose masks are less efficient for self-protection. Respiratory masks are required for this purpose, which show a high degree of separation even for fine particles, e.g. of classes FFP2, N95 or KN95. These are efficient for both self-protection and protection of others unless they have an exhalation valve. Masks with an exhalation valve, on the other hand, are only for self-protection and therefore contradict the solidarity concept that fellow human beings are protected by collective mask wearing. Face shields which are used without additional masks are largely useless with regard t• aerosol particles, as the air with particles (and viruses) flows unfiltered around the shields. In everyday clinical practice, facial shields are worn in addition to masks to prevent droplet infection via the mucous membranes of the eyes. Mobile or permanently installed Plexiglas barriers are also largely ineffective against the spread of aerosols indoors. These can only prevent the smallscale spread of an aerosol in the short term, e.g. in the checkout area of a supermarket, but offer no protection in the longer term. Face shields and Plexiglas panels essentially serve as spit and splash protection against large droplets.
• Outdoors, there are practically no infections caused by aerosol transmission. However, droplet infections can still occur, especially in crowds, if minimum distances are not observed and/or masks are not worn. In closed rooms, ventilation is essential to replace the exhaled air in a room with fresh air from outside. Frequent airing and cross-ventilation is just as effective as leaving the window open all the time. From an energy point of view, however, it is more efficient to ventilate the room, especially in winter. CO2 monitors can help to monitor indoor air quality. They indicate when it is necessary to ventilate and when the air in a room has been sufficiently changed during ventilation. However, they can only be used as an indicator and even if the proposed CO2 limit concentrations are met, they do not prevent direct infection by people in the immediate vicinity.
• Air purifiers can make a useful contribution to reducing the concentration of particles and viruses in a room. When procuring air purifiers, care must be taken to ensure that they are adequately dimensioned for the room and application in question in order to significantly reduce the particle and virus load. The air throughput of the unit is more important than the pure efficiency of the filter. For energy and cost reasons, the use of highly efficient filters can even be counterproductive. Permanently installed ventilation systems can also be useful, provided they filter the air to reduce the particle and virus load in a room. To avoid infections, it is advisable to operate them with 100 % fresh air if possible.
From the point of view of the Gesellschaft für Aerosolforschung, there is a considerable need for research, especially at the interdisciplinary borders to research fields of epidemiology, infectiology, virology, ventilation technology and fluid mechanics. The implementation of targeted studies should be made possible at short notice with special funding and research programmes.
This paper was written originally in German by members of the Gesellschaft für Aerosolforschung and is supported by a large number of international aerosol experts. Both the English and German version as well as all images in the paper are available for free download at the following link: https://www.info.gaef.de/positionspapier. The “Gesellschaft für Aerosolforschung e. V.” must be named as the source, whenever an image is used.
Dass Viren sich über Aerosolpartikel ausbreiten können, wurde bereits in vielen Studien gezeigt. Als Aerosol bezeichnet man ein Gemisch aus Luft mit darin verteilten festen oder flüssigen Partikeln. Ein Aerosol ist dabei immer dynamisch, da Partikel neugebildet, in oder mit der Luft transportiert und aus der Luft entfernt werden oder sich im luftgetragenen Zustand verändern. Zum Verständnis der Rolle von Aerosolpartikeln als Übertragungsweg von SARS-CoV-2 ist daher die Kenntnis der verschiedenen Prozesse in einem Aerosol von besonderer Bedeutung. Mit diesem Papier möchte die GAeF einen Beitrag dazu leisten, den momentan so häufig anzutreffenden Begriff „Aerosol“ sowie die relevanten Aerosolprozesse anschaulich darzustellen und zu erläutern. Dabei wird im Rahmen dieses Papiers nur auf die wesentlichen Grundlagen eingegangen.
Für ein tiefergehendes Verständnis der teilweise komplexen Prozesse sei auf die angeführte Sekundärliteratur verwiesen. Das Papier fasst eine Vielzahl von Studien zur Entstehung von virenbeladenen Aerosolpartikeln sowie deren Ausbreitung zusammen. Darauf basierend kann festgestellt werden, dass ausgeatmete Aerosolpartikel auch bei der Corona-Pandemie eine prominente Rolle bei der Verbreitung der Viren spielen. Abschließend geht dieses Papier auf mögliche Maßnahmen zur Verringerung der Ausbreitung von Aerosolpartikeln ein. Die diskutierten Maßnahmen orientieren sich an der derzeitigen öffentlichen Diskussion und beinhalten entsprechend die folgenden Punkte: Lüften, Luftreiniger, Lüftungsanlagen und Masken. Es werden Hinweise zum richtigen und sinnvollen Einsatz dieser Maßnahmen gegeben. Aerosolpartikel haben Größen zwischen ca. 0,001 und mehreren 100 Mikrometern (und nicht wie in vielen Publikationen derzeit definiert < 5μm) und verteilen sich mit Luftströmungen relativ schnell, auch über größere Distanzen. Größere Aerosolpartikel sinken – abhängig von ihrer Größe und Dichte – zu Boden; kleine Aerosolpartikel können hingegen sehr lange in der Luft verbleiben (s. Kapitel 3). Jeder Mensch stößt durch die Atmung sowie beim Sprechen, Husten und Niesen flüssige Aerosolpartikel unterschiedlicher Größen aus (s. Kapitel 4). Ist eine Person mit einem Virus, wie z. B. SARS-CoV-2, infiziert, so können diese Aerosolpartikel Viren enthalten, die in die Luft gelangen und von anderen Personen eingeatmet werden können. SARS-CoV-2 hat eine Größe von 0,06 bis 0,14 Mikrometer, die exhalierten flüssigen Aerosolpartikel sind hingegen größer. Die flüssigen Aerosolpartikel können aber je nach Umgebungsbedingungen durch Verdunstung schrumpfen (s. Kapitel 3.3). Für den Partikeltransport und die Partikelabscheidung ist dabei jeweils die aktuelle Partikelgröße relevant. Das höchste Infektionsrisiko besteht in geschlossenen Innenräumen, da sich hierin Aerosolpartikel anreichern können. Insbesondere hier sind entsprechend Maßnahmen zu treffen, die eine Reduktion der Aerosolpartikelkonzentration ermöglichen.
Vor dem Hintergrund der Aerosolwissenschaften ordnet die GAeF die aktuellen Maßnahmen zur Eindämmung der Pandemie wie folgt ein:
• Prinzipiell gilt: Keine Maßnahme kann für sich alleine funktionieren! Das Zusammenspiel der verschiedensten Maßnahmen ist nach derzeitigem Wissensstand der beste Weg zur Minimierung des Infektionsrisikos.
• Abstand halten ist wichtig, denn mit zunehmendem Abstand werden direkt ausgeatmete Viren verdünnt, und die Wahrscheinlichkeit sich anzustecken sinkt. Der vielfach vorgeschriebene Mindestabstand kann als Anhaltspunkt dienen, sollte aber insbesondere bei längeren Zusammenkünften und auch in Innenräumen mit verringerter Luftbewegung vergrößert und durch weitere Maßnahmen (s.u.) ergänzt werden.
• Masken helfen, einen Teil der exhalierten Partikel (und Viren) zu filtern. Dadurch sinkt die Konzentration der exhalierten Partikel (und Viren) in einem Raum und damit das Infektionsrisiko. Hierbei ist zu beachten, dass die ausgeatmeten Aerosolpartikel durch anhaftende Feuchtigkeit relativ groß sind und somit auch von einfachen Masken effizient zurückgehalten werden können. Da diese Partikel aber mit längerer Verweilzeit in der Raumluft schrumpfen, sind einfache Mund-Nasen-Bedeckungen für den Selbstschutz weniger effizient. Hierfür sind Atemschutzmasken erforderlich, die auch für feine Partikel eine hohe Abscheidung zeigen, z. B. der Klassen FFP2, N95 oder KN95. Diese sind sowohl für den Selbst- als auch den Fremdschutz effizient, sofern sie über kein Ausatemventil verfügen. Masken mit Ausatemventil dienen hingegen nur dem Selbstschutz und widersprechen daher dem Solidaritätskonzept, dass Mitmenschen durch kollektives Maskentragen geschützt werden.
• Gesichtsvisiere, die ohne zusätzliche Verwendung von Masken eingesetzt werden, sind hinsichtlich Aerosolpartikeln weitgehend nutzlos, da die Luft mit Partikeln (und Viren) ungefiltert um die Visiere herumströmt. Gesichtsvisiere werden im klinischen Alltag zusätzlich zu Masken getragen, um Tröpfcheninfektion über die Schleimhäute der Augen zu verhindern. Ebenfalls weitgehend unwirksam gegen die Aerosolverbreitung in Innenräumen sind mobile oder fest installierte Plexiglasbarrieren. Diese können nur kurzfristig die kleinräumige Ausbreitung eines Aerosols, z. B. im Kassenbereich eines Supermarkts, verhindern, bieten aber längerfristig keinen Schutz. Gesichtsvisiere und Plexiglasscheiben dienen im Wesentlichen als Spuck- und Spritzschutz gegenüber großen Tröpfchen.
• Im Freien finden so gut wie keine Infektionen durch Aerosolpartikel statt. Allerdings können Tröpfcheninfektionen auftreten, insbesondere in Menschenansammlungen, wenn Mindestabstände nicht eingehalten und/oder keine Masken getragen werden. In geschlossenen Räumen ist Lüften unerlässlich, um die ausgeatmete Luft in einem Raum durch frische Luft von draußen zu ersetzen. Häufiges Stoß- und Querlüften sind dabei vergleichbar effektiv wie dauernd das Fenster vollständig geöffnet zu lassen. Aus energetischer Sicht ist Stoß- oder Querlüften insbesondere im Winter allerdings effizienter. CO2-Monitore können bei der Überwachung der Luftqualität in Innenräumen helfen. Sie zeigen an, wann gelüftet werden sollte und wann die Luft in einem Raum während des Lüftens ausreichend gewechselt ist. Sie können jedoch nur als Indikator verwendet werden und verhindern selbst bei Einhaltung der vorgeschlagenen CO2-Grenzkonzentrationen keine direkte Infektion durch unmittelbar benachbarte Personen.
• Luftreiniger können einen sinnvollen Beitrag leisten, um die Partikel- und Virenkonzentration in einem Raum zu reduzieren. Bei der Beschaffung von Luftreinigern muss darauf geachtet werden, dass diese für den betrachteten Raum und die betrachtete Anwendung ausreichend dimensioniert sind, um die Partikel- und Virenlast signifikant zu verringern. Dem Luftdurchsatz des Gerätes kommt dabei eine größere Bedeutung zu, als der reinen Effizienz des Filters. Aus energetischen und Kostenerwägungen kann die Verwendung hocheffizienter Filter sogar kontraproduktiv sein. Fest verbaute Lüftungsanlagen können ebenso sinnvoll sein, sofern sie die Luft filtern, um die Partikel- und Virenlast in einem Raum zu verringern. Hierbei ist es zur Vermeidung von Infektionen sinnvoll, diese möglichst mit 100 % Frischluft zu betreiben.
Aus Sicht der Gesellschaft für Aerosolforschung besteht erheblicher Forschungsbedarf insbesondere an den interdisziplinären Grenzen zu Forschungsfeldern der Epidemiologie, Infektiologie, Virologie, Lüftungstechnik und Strömungsmechanik. Die Durchführung gezielter Studien sollte kurzfristig mit speziellen Förder- und Forschungsprogrammen ermöglicht werden. Dieses Papier wurde von Mitgliedern der Gesellschaft für Aerosolforschung verfasst und wird von einer Vielzahl internationaler Aerosolexperten unterstützt (s. Kapitel 8). Neben der vorliegenden Version existiert auch eine englischsprachige Übersetzung (siehe www.info.gaef.de). Sämtliche Abbildungen in diesem Papier stehen unter folgendem Link zum kostenlosen Download bereit: https://www.info.gaef.de/positionspapier. Bei jeder Verwendung ist „Gesellschaft für Aerosolforschung e. V.“ als Quelle zu nennen.
Zellen, als Grundeinheit für Organismen, bilden einen wesentlichen Eckpfeiler für das Leben. Die Untersuchung von einzelnen Zellen liefert wertvolle Einblicke in fundamentale Prozesse des Lebens. So können Anomalien auf der Zelleebene Indikatoren für Krankheiten sein und durch eine Analyse früh erkannt werden. Weiterhin kann durch ein tiefgreifendes Verständnis von Vorgängen in Zellen auch gezielt Forschung zu z.B. neuen Medikamenten betrieben werden. Damit können die Wirksamkeit erhöht und die Nebenwirkungen reduziert werden.
The Scythica Vindobonensia, the new fragments on Gothic incursions into Roman provinces in the Balkans in the middle of the third century AD that were revealed some years ago in a Greek palimpsest at the Austrian National Library in Vienna (ÖNB), are commonly considered as one of the most important additions of the last decades to the corpus of texts from classical Antiquity. Tere is a high degree of confdence among scholars in supposing that the fragments come from the lost work Scythica written in Greek by the third-century historian P. Herennius Dexippus (Δέξιππος) of Athens. The new fragments have hence also been called Dexippus Vindobonensis. In his Scythica, Dexippus recorded wars of the Romans with the Goths (and other tribes) whom he called Scythians.
The work had been hitherto known only from excerpts and quotes by later authors. Eight pages of a Byzantine manuscript copy of the ancient text have survived hidden underneath the visible surface of the last four parchment folios of the Vienna manuscript Historicus graecus 73, f. 192r -195v4. The copy is written in a Greek calligraphic minuscule which has been estimated by palaeographers to be of the middle or the second half of the eleventh century. In the thirteenth century, the text (on each of the eight pages arranged in one column, with 30 lines per page) was washed of the parchment and the valuable material made from animal skin was re-used for Christian texts. The new writing largely covered the faded remnants of the original text. It thus became hidden from the human eye for more than seven hundred years. Its discovery by Jana Grusková, a classical philologist specialized in the transmission of Greek texts, resulted from a systematic review of all Greek palimpsests kept at the Austrian National Library in Vienna at the beginning of the twenty-first century and a detailed examination of the four folios in 2007-20097.
Final Draft of the OECD Test Guideline for Particle Size and Particle Size Distribution of Nanomaterials.
The OECD Working Party on Manufactured Nanomaterials (WPMN) has actively worked towards understanding possible safety issues for manufactured nanomaterials and has contributed significantly to resolving these by developing Test Guidelines, Guidance Documents, Test Reports and other publications with the aim of a safe use of manufactured nanomaterials. The OECD website (www.oecd.org/science/nanosafety) and the referenced publications contain more background information.
Among others, the OECD Test Guideline “Particle Size Distribution/Fibre Length and Diameter Distributions” (TG 110, adopted in 1981) was identified to require an update to address the specific needs of manufactured nanomaterials as the TG 110 is currently only valid for particles and fibres with sizes above 250 nm. The WPMN prioritised to either update TG 110 to be applicable also to particles at the nanoscale or draft a new nanomaterial specific Test Guideline (TG). Eventually, it was decided to develop a new TG for particle size and particle size distribution measurements of nanomaterials covering the size range from 1 nm to 1000 nm for further justification. This TG overlaps with TG 110 in the size range from 250 nm to 1000 nm. When measuring particulate or fibrous materials, the appropriate TG should be selected depending on the size range of particles tested. In line with TG 110, the new TG for nanomaterials includes separate parts for particles and fibres. For the part of this TG which addresses particles, several methods applicable to nanomaterials were reviewed and included to take into account developments since 1981 when the TG110 was adopted. This TG includes the following methods: Atomic Force Microscopy (AFM), Centrifugal Liquid Sedimentation (CLS)/Analytical Ultracentrifugation (AUC), Dynamic Light Scattering (DLS), Differential Mobility Analysis System (DMAS), (Nano)Particle Tracking Analysis (PTA/NTA), Small Angle X-Ray Scattering (SAXS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM).
For measuring the diameter and length of fibres, analysing images captured with electron microscopy is currently the only method available. This TG includes Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM).
To test the validity of this TG, an ILC was performed. Test materials were chosen to reflect a broad 68 range of nanomaterial classes, e.g. metals, metal oxides, polymers and carbon materials. Where possible, well-characterised test materials were used. Additionally, the test materials were chosen, so that they reflect a broad range of sizes representing the size range 1 nm to 1000 nm and finally,
for fibres only, aspect ratios from length/diameter of 3 to > 50.
Experimentelle Charakterisierung der WIG-Schweißeignung einer Hoch- und Mediumentropie-Legierung
(2021)
Equiatomic multi-element systems with defined entropy are a relatively new mate-rial concept for alloy production. These alloys consist of at least five elements in equiatomic distribution in the case of high entropy alloys (HEA) and three to four elements in equiatomic distribution in the case of medium entropy alloys (MEA). Previous studies on these alloys have focused primarily on their production, micro-structure and the resulting material properties. Meanwhile, the focus here is on the processing of the alloys and their influence on future applications. Up to now, there has been insufficient knowledge of the materials and processes involved in weld-ing.
In this work, therefore, the weldability of a CoCrFeMnNi-HEA and a CoCrNi-MEA by means of a TIG welding process was investigated as a basic system. To this end, the welding parameters were first determined on a reference alloy (Ni-based: 2.4858) and transferred to the welding of the CoCrFeMnNi-HEA and CoCrNi-MEA. Weldability was assessed by testing the absence of defects and microstructures obtained. The weld metal exhibited the dendritic microstructure typical of TIG, with microsegregations forming as interdendritic phases. Increased hardness was de-tected in the weld metal compared to the base metal. In the heat-affected zone, there was little grain growth and, in both alloys, the formation of hot cracks after welding. The cause of the cracks was to be found in the specimen preparation, which had an influence on the subsequent processing. After elimination of this in-fluence, no welding process-related imperfections were found in the CoCrFeMnNi-HEA and CoCrNi-MEA.
In summary, both materials show good fusion weldability by TIG welding. The re-sults of this work thus contribute to the understanding of the weldability of HEA and in particular for CoCrNi-MEA, which was considered in this depth for the first time.
T cells need to adapt their cellular metabolism for effector cell differentiation. This relies on alterations in mitochondrial physiology. Which signals and molecules regulate those alterations remains unclear. We recently reported, that the mitochondrial protein TCAIM inhibits activation-induced changes in mitochondrial morphology and function and thus, CD effector T cell formation. Using conditional TCAIM knock-in (KI) and knockout (KO) mice, w now show that it also applies to CD8+ T cells and more importantly, delineate the molecular processes in mitochondria by which TCAIM controls effector cell differentiation. TCAIM KI resulted in reduced activation-induced HIF1α protein expression. Metabolomics and transcriptional data in combination with mathematical flux modeling revealed an impaired induction of anabolic pathways, especially of the mevalonate pathway and cholesterol biosynthesis in TCAIM KI CD8+ T cells. Addition of cholesterol completely rescued HIF1α protein expression, activation and proliferation of TCAIM KI CD8+ T cells. At the molecular level, TCAIM delayed activation-induced mitochondria-ER contact (MERC) formation by binding to MERC promoting proteins such as RMD3 and VDAC2. In summary, we demonstrate that TCAIM suppresses effector cell differentiation by inhibiting MERC formation, which induce HIF1α-mediated increase in cellular metabolism and cholesterol biosynthesis.
Die Potentialmessung kann zum Auffinden korrosionsaktiver Bereiche neben Stahlbetonbauwerken auch bei Spannbetonbauwerken angewandt werden, die mit Spannstählen im direkten Verbund hergestellt werden. Bei Vorspannsystemen mit metallischen Hüllrohren im nachträglichen Verbund ist eine Aussage über den Korrosionszustand des Hüllrohrs, nicht aber des Spannstahls möglich. Messungen an Spannbetonbauteilen erfordern grundsätzlich die besonderen Kenntnisse eines Spezialisten.
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
The publicly available document encapsulates the first version of the Catalogue of Services of the future EC4Safenano Centre (CoS 2019).
The CoS 2019 is structured in 12 Service Categories and 27 Service Topics, for each of the 12 categories considered. This architecture configures a 12 x 27 matrix that allows ordering the potential EC4Safenano offer in 324 types of services/groups of services.
Each type of service/group of services is described, in a simple and friendly way, by means of a specific service sheet: the EC4Safenano - Service Data Sheet (EC4-SDS). These EC4-SDSs allow structuring and summarizing the information of each service, providing the customer with a concise view of characteristics of the service and also the contact details with the service provider.
The CoS 2019 deploys a map of services consisting of a set of 100 EC4-SDSs, covering 7 of the 12 Service Categories and 17 of the 27 Service Topics.
The harmonization of services is visualized as a future necessary step in EC4Safenano, in order to strengthen the offer and provide added value to customers with a growing offer of harmonized services in future versions of the CoS.
The information contained in this document is structured in 3 main sections, as follows:
• Catalogue structure. This section describes in short the main characteristics of the CoS 2019.
• Catalogue content. This section represents the core part of the document and encapsulates the set of 100 SDSs displaying the offer proposed by the CoS 2019.
• Online Catalogue. This section describes the resources implemented by EC4Safenano to facilitate the on-line consultation of the CoS 2019 by customers and other interested parties.
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules.
After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
In vielen Umgebungen, besonders bei hohen Temperaturen, korrosiven Umgebungen oder auf bewegten oder schlecht zugänglichen Flächen, kann die Temperatur nicht oder nur mit nicht akzeptablem Aufwand mit Berührungsthermometern gemessen werden. Diese Umgebungsbedingungen sind unter anderem in der chemischen Industrie, der Lebensmittel-, Metall-, Glas-, Kunststoff- und Papierherstellung sowie bei der Lacktrocknung anzutreffen. In diesen Bereichen kommen Strahlungsthermometer zum Einsatz. Der VDI-Statusreport zeigt typische Anwendungsfelder von nicht radiometrisch kalibrierten Wärmebildkameras und von radiometrisch kalibrierten Thermografiekameras. Um verlässlich mit spezifizierten Messunsicherheiten berührungslos Temperaturen zu messen, müssen die Strahlungsthermometer und Thermografiekameras nicht nur kalibriert, sondern radiometrisch und strahlungsthermometrisch umfassend charakterisiert werden. Auch die optische Materialeigenschaft, der spektrale Emissionsgrad und die Gesamtstrahlungsbilanz (Strahlung des Messobjekts und der Umgebung) sind bei der industriellen Temperaturmessung von großer Bedeutung. In den letzten Jahrzehnten ist dazu ein umfassendes technisches Regelwerk entstanden, das wir Ihnen mit diesem VDI-Statusreport vorstellen. Manche in den Richtlinien beschriebenen Kennwerte mögen abstrakt wirken. In diesem Statusreport zeigen wir an konkreten Beispielen, was diese Kenngrößen für die berührungslose Temperaturmessung bedeuten. Beispiele von Anwendungen zeigen, wo temperaturmessende Thermografiekameras und ausschließlich bildgebende Wärmebildkameras in der Praxis eingesetzt werden. Mit einer Analyse, welche Themen und Anwendungen derzeit besonders intensiv diskutiert werden, versuchen wir Trends für zukünftige Entwicklungen herauszuarbeiten.
Dieses Strategiepapier zielt darauf ab, Akteuren und Entscheidungsträgern den Status der Digitalisierung in der keramischen Fertigung, erfolgreiche Best-Practice-Beispiele aber auch die Herausforderungen nahezubringen, die es nun anzugehen gilt. Es ist die Vision, die Keramikfertigung durchgehend zu digitalisieren und alle Schritte des Produktkreislaufs lückenlos über die gesamte Wertschöpfungs- und Nutzungskette zu vernetzen: also eine Keramikindustrie 4.0 zu etablieren. Das Strategiepapier erfasst zunächst die Spezifität der keramischen Fertigung und nimmt eine Analyse des gegenwärtigen Standes der Digitalisierung in der keramischen Industrie vor, auch anhand einiger ausgewählter Beispiele aus der industriellen Praxis. Auf Basis der wesentlichen Bausteine für eine Fertigungsdigitalisierung werden schließlich die Chancen für Keramikproduzenten sowie der erforderliche Forschungs- und Entwicklungsbedarf aufgezeigt.
This document presents the specification for the execution and evaluation of high-speed tensile tests on reinforcement bar coupler systems. This specification was developed at BAM - Bundesanstalt für Materialforschung und -prüfung (Federal Institute for Materials Research and Testing, Germany) - following test principles from related international standards.
The present document represents the latest status of the test specification. It is noted that until 2010 the test procedure was characterised on a test velocity based on L0. In an improved test conception and after intensive investigations in cooperation with industry partners, this procedure has been updated to consider instead a test velocity based on Lr, since this warrants more comparable and meaningful results.
In den vergangenen Jahren ist die Entwicklung additiver Fertigungsverfahren branchenübergreifend fortgeschritten. In der Industrie ist die Verarbeitung von Polymeren wie z. B. Polylactide (PLA) oder Acrylnitril-Butadien-Styrol-Copolymer (ABS) am weitesten verbreitet, aber auch die Verarbeitung von Metallen nimmt zu. Umfragen des Fraunhofer-Institut für Produktionstechnik und Automatisierung IPA aus dem Jahr 2016 verdeutlichen, wie hoch das Potential additiver Fertigungsverfahren eingeschätzt wird und auch die Anzahl der jährlich angemeldeten Patente im Bereich des 3D-Drucks hat sich in den letzten Jahren vervielfacht.
Das gegenwärtige globale Wirtschaftsmodell basiert auf dem Prinzip linearen Wachstums. Aufgrund der Endlichkeit natürlicher Ressourcen wird dieser Wachstumsgedanke in Zukunft jedoch an Grenzen stoßen. Schon in den 1960er Jahren haben Ökonomen das Modell einer Kreislaufwirtschaft, einer Circular Economy, entwickelt. Es zielt darauf ab, den Gebrauchswert von Ressourcen entlang der gesamten Wertschöpfungskette zu optimieren und Materialkreisläufe zu schließen.
2019 hat die Europäische Kommission ihren Aktionsplan zur Circular Economy aus dem Jahr 2015 bekräftigt und aktualisiert. Auch die deutsche Bundesregierung unterstützt diese internationalen Bemühungen seit langem mit ihrer Nachhaltigkeitsstrategie und ihrem Ressourceneffizienzprogramm.
Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist in vielfältiger Weise in diese Aktivitäten involviert. Unter dem Motto „Sicherheit in Technik und Chemie“ arbeiten wir gemeinsam mit Partnern aus Wirtschaft und Forschung im Bereich der Prozess- und Produktsicherheit sowie der Umweltsicherheit. Dabei legen wir besonderes Augenmerk auf Ressourceneffizienz, indem wir neue Verfahren zur Extraktion wertvoller Ressourcen aus Abfällen und zur Wiederverwertung von Massenreststoffen entwickeln. Wir analysieren die Beständigkeit und das Alterungsverhalten von Kunststoffen und untersuchen die Umweltverträglichkeit und Dauerhaftigkeit innovativer Bauprodukte aus Abfällen.
Zudem ist die BAM in nationalen und internationalen Gremien bei der Normung und Regelsetzung im Bereich Kreislaufwirtschaft tätig und fördert den Wissensaustausch zwischen Forschung und Industrie. So leisten wir einen wichtigen Beitrag zur Transformation der deutschen und europäischen Wirtschaft hin zu einer Circular Economy.
Nanomaterials and nanoparticles are finding applications across a wide range of technology sectors, from medicine and food to transportation and construction. In order to assess these new materials for potential risks to health and the environment, they need to be well-characterised. The measurement of constituent nanoparticle size, shape, and size distribution are important factors for the risk evaluation process.
EMPIR project Improved traceability chain of nanoparticle size measurements (17NRM04, nPSize) is working to assess a range of traceable nanoparticle measurement approaches, including Scanning Electron Microscopy (also in Transmission Mode), Atomic Force Microscopy and Small Angle X-ray Scattering, and deliver improved calibration methods to users. For the techniques under investigation, physical models of their response to a range of nanoparticle types are developed. Validated reference materials will also be used for an inter-comparison of measurement systems, with an evaluation of the associated measurement uncertainty. With project contributions to standards development work, manufacturers will be better placed to assess the human and environmental risks posed by nanomaterials across a whole range of products.
Covid 19 stellt Gesellschaft und Wirtschaft vor immense Herausforderungen – auch die Konformitätsbewertungsbranche ist betroffen. Die Bundesanstalt für Materialforschung und -prüfung (BAM) hat gemeinsam mit der TU Berlin und
dem Fraunhofer ISI die Auswirkungen der Pandemie auf die wirtschaftliche und operative Lage von Konformitätsbewertungsstellen in Deutschland untersucht. Dabei standen auch die Digitalisierung sowie die Resilienz der Branche im
Fokus.
Lo scoppio della pandemia da Covid-19 ha travolto Italia a inizio anno e i suoi effetti sull’economia sono stati particolarmente pesanti.
Proprio per analizzare gli effetti della pandemia sul mercato della valutazione della conformità, lo scorso settembre Accredia, in collaborazione con l’Istituto Federale tedesco della Ricerca e del Collaudo dei Materiali (BAM), la Technische Universität di Berlino e l’Istituto Fraunhofer ISI, ha condotto un’indagine presso gli organismi e i laboratori accreditati in Italia.
Diese Richtlinie definiert Kenngrößen und Messverfahren, um Terahertzsysteme für die Zeitbereichsspektroskopie (TDS)zu spezifizieren. So können Hersteller ihre Systeme übereinstimmend beschreiben und Anwender einfach Systeme vergleichen. Systeme für die Terahertz-Zeitbereichsspektroskopie sind aktive Systeme und nutzen verschiedene Techniken sowohl zur Erzeugung als auch zur zeitaufgelösten Messung von breitbandigen Terahertzimpulsen. Die dazugehörigen Terahertzspektren und -Phasen werden nach einer zeitlichen Abtastung über eine Fourier-Transformation berechnet. In dieser Richtlinie wird ein Überblick über die Funktionsweisen von Zeitbereichsspektrometern gegeben, die eingesetzten Messverfahren näher erläutert sowie die benötigten Begriffe und Kenngrößen definiert. Die Richtlinie konzentriert sich dabei auf Systeme, die auf sogenannten Abtastmessverfahren (Sampling-Messverfahren) basieren.
The image designed by Natalia Cano Murillo and colleagues shows the cross section of a ternary composite (boehmite/polycarbonate/epoxy, 80μm x 80μm). The surface was measured by AFM kelvin probe microscopy, yielding the surface potential which is shown as 3D‐surface and contour lines. The sample was further subjected to AFM force spectroscopy with a lateral resolution of 1μm², yielding the local Young's modulus, projected in false colors on the 3D surface. The ternary system, containing boehmite nanoparticles, shows a broad distribution of modulus, desirable for optimized macroscopic mechanical properties, such as high stiffness as well as toughness.
Plant and process safety are very important within the daily business not only in industry. Within its 6th edition complete analysis of design, operational, and management causes of process plant accidents and disasters are collected by Paul Amyotte basing on Trevor Kletz's legacy. Examples shall help readers in understanding what went wrong, why it went wrong and how to avoid similar tragedies without having to experience the loss incurred by others and themselves. Each main part ends with an opportunity for reflection to recall the lessons learned from the examples shown.
This collection of, unfortunately, spectacular failure cases fulfills its intension of being the ultimate resource of experienced‐based analysis and guidance for safety and loss prevention professionals. Everyone who is dealing with process and/or plant safety shall have taken at least a look into this book.
Currently, storage of electric energy is becoming more and more interesting in terms of applicability and efficiency. One way is the electrochemical storage by already well‐developed battery‐systems. This textbook provides an introduction into physical and chemical processes necessary for battery application.
This book fulfills its intension to serve graduate students of electrical engineering as an introduction into the field of batteries. Even students and interested readers of other faculties might find an introduction in physical and chemical background of batteries.
Unabhängig vom im Chemieunterricht erworbenen Wissensstand der Studienanfänger liefert dieses, in der Reihe „De Gruyter Studium“ erschienene Lehrbuch einen Einstieg in die Physikalische Chemie. Basierend auf den Erfahrungen seiner Lehrtätigkeit für Erstsemester der Fachrichtung Chemie an der Universität des Saarlandes geht der Autor auf beinahe alle Themengebiete der Physikalischen Chemie ein, wobei die Schwerpunkte auf klassischer Thermodynamik und Grundlagen der chemischen Bindung liegen.
Dieses Lehrbuch ist nicht nur für Studierende im Bachelorstudium der Chemie sowohl im Haupt‐ als auch im Nebenfach geeignet. Es liefert zudem Interessierten anderer Fachrichtungen einen übersichtlichen und verständlichen Einstieg in die komplexe Welt der Physikalischen Chemie und sorgt für ein Grundverständnis.
Polymere sind aus unserem Alltag nicht mehr wegzudenken. Häufig haben wir mit Plexiglas, Dichtmassen, Klebestreifen und vielen Verpackungsmaterialien zu tun. Aber auch Spezialanwendungen (z.B. in der Pharmazie) bilden Einsatzbereiche dieser Werkstoffe.
Der Vermittlung der Grundlagen polymerer Werkstoffe in den Studienfächern Chemie, Materialwissenschaften und der Ingenieur‐ und Lebenswissenschaften haben sich die Autoren verschrieben, wobei sie zur verständlichen Anschauung bewusst auf das Beispiel Styrol als „Versuchskaninchen“ zurückgreifen.
Dieses Lehrbuch wird seinem Anspruch gerecht, einen leichten Einstieg in die Polymerwissenschaften zu ermöglichen. Es liefert eine Übersicht über die Polymerklassen Thermoplaste, Duroplaste und Elastomere mit ihren Eigenschaften und zeigt, welche Synthesestrategie zu dem Produkt mit den gewünschten Eigenschaften führt. Anhand von Beispielen aus dem Alltag werden gängige Vertreter verständlich vorgestellt.
Rund ein Jahr haben DIN und DKE in einem gemeinsamen Projekt mit dem Bundesministerium für Wirtschaft und Energie und zusammen mit ca. 300 Fachleuten aus Wirtschaft, Wissenschaft, öffentlicher Hand und Zivilgesellschaft an der Normungsroadmap Künstliche Intelligenz gearbeitet. Eine hochrangige Steuerungsgruppe unter dem Vorsitz von Prof. Wolfgang Wahlster hat die Erarbeitung koordiniert und begleitet.
Ziel der Roadmap ist die frühzeitige Entwicklung eines Handlungsrahmens für die Normung und Standardisierung, der die internationale Wettbewerbsfähigkeit der deutschen Wirtschaft unterstützt und europäische Wertmaßstäbe auf die internationale Ebene hebt.
You Ask – ACEnano Replies
(2020)
The workshop starts with introductory information about the workshop and the H2020 project ACEnano, followed by two expert round tables, focussing on how the project could address regulator and industry needs, respectively. This is be followed by parallel sessions on tools (based on preferences expressed by those registered to attend, see “Questions”) and finally a question-and-answer session with the attendees.
The experts invited in Round Table 1 have been prepared to answer to questions related to obstacles and advantages for stakeholders such as SMEs to use the ACEnano approaches/tools. Standardisation needs are discussed.
There is growing interest in quantifying microplastics in environmental samples. This application note presents a thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) method that is well suited to automation and increased sample throughput. The method is also able to detect all particle sizes in the sample as long as the limit of detection (LOD) is reached and allows analysis of larger samples of 15 to 25 mg or more. Samples were decomposed by thermogravimetric analysis (TGA), and the gaseous decomposition products were trapped on a solid-phase sorbent, followed by thermal desorption‑gas chromatography/mass spectrometry (TD-GC/MS) using an Agilent 5977B GC/MSD coupled to an Agilent 7890B GC. Target microplastic particle (MP) polymers were identified in environmental samples including surface water, finished compost, house dust, and drinking water. Quantification of MP polymers in environmental samples provided LODs of 0.06 to 2.2 μg, allowing the detection of MPs in trace amounts with sample weights of up to 1 g. Method repeatability was adequate for reliable quantification with RSDs of approximately 6 to 12%.
Since data processing has now also found its way into materials science, there has been a great demand from users for a corresponding textbook. This book provides a guide to the latest advances of materials informatics and data mining for materials science. 46 authors introduce readers to methods, present tools and case studies to illustrate the power of materials informatics within this new field of application.
Schlosserei‐, Metall‐ und Stahlbaubetriebe müssen seit Juli 2012 für tragende Bauteile aus Stahl und Aluminium, die als Bauprodukte in Verkehr gebracht werden sollen, einen Konformitätsnachweis nach DIN EN 1090‐1 erbringen.
Mit der sechsten Auflage des Normen‐Handbuches „Schweißen im Stahlbau“ setzen das Deutsche Institut für Normung e.V. (DIN) und der Deutsche Verband für Schweißen und verwandte Verfahren e.V. (DVS) ihre bewährte Strategie fort, die dieses Thema betreffenden aktuellen Normen und Regelwerke durch J. W. Mußmann in gut aufbereiteter Form kompakt zusammenzustellen.