Sanitär- und Kommunaltechnik; Umwelttechnik
Filtern
Erscheinungsjahr
Dokumenttyp
- Posterpräsentation (356) (entfernen)
Sprache
- Englisch (303)
- Deutsch (52)
- Mehrsprachig (1)
Referierte Publikation
- nein (356)
Schlagworte
- Biocides (19)
- Mikroplastik (15)
- Biofilm (12)
- Microplastics (12)
- Soil (12)
- Mobile Robot Olfaction (11)
- Corrosion (10)
- ELISA (10)
- Immunoassay (10)
- Amoxicillin (9)
Organisationseinheit der BAM
- 4 Material und Umwelt (100)
- 1 Analytische Chemie; Referenzmaterialien (79)
- 4.1 Biologische Materialschädigung und Referenzorganismen (46)
- 1.8 Umweltanalytik (39)
- 6 Materialchemie (35)
- 6.6 Physik und chemische Analytik der Polymere (22)
- 8 Zerstörungsfreie Prüfung (22)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (18)
- 1.4 Prozessanalytik (17)
- 4.0 Abteilungsleitung und andere (16)
Per- and polyfluoroalkyl substances (PFAS) have received global public attention because of their wide distribution in aquatic environments and potential adverse effects to humans and wildlife. Due to the lack of analytical standards and the enormous numbers of these compounds, current target-based methods (e.g., LC-MS/MS) are not suitable for the analysis of new/unknown PFAS and transformation products. Therefore, PFAS sum parameter analysis is becoming increasingly important. For PFAS determination of surface waters, solid phase extraction (SPE) is commonly implemented for clean-up and pre-concentration of samples.
Thus, within this work, single-layer SPE methods (based on Strata™-X, Strata™-X-AW, Strata™-NH2 and Oasis-HLB) were investigated for maximum PFAS coverage utilizing extractable organically bound fluorine (EOF) analysis. Thereby, the optimization procedure relied on the analysis of 3 surface water samples in Berlin, Germany, which were affected by the effluent discharge of wastewater treatment plants. To analyse the SPE elution profiles for EOF and inorganic fluorine, high resolution-continuum source-graphite furnace molecular absorption spectroscopy (HR-CS-GFMAS) and ion chromatography (IC) were used, respectively.
Highest EOF concentrations were achieved by using Strata-X/Strata-XAW as SPE sorbents and methanol as eluent. Furthermore, combinations of the most promising SPE sorbents were selected (X/XAW, XAW/X, HLB/X and WAX/GCB) to extract a wider range of PFASs. By comparing multi-layer SPE methods, lower EOF concentrations were obtained for all investigated combination phases compared to the analysed single phases. For the commercially available combination phase Strata-PFAS (WAX/GCB) for all three river water samples, lower EOF concentrations (1.5 times lower) were determined compared to Strata-X.
The results have shown that single-layer SPE systems are currently superior compared to combination phases for PFAS sum parameter analysis. The multi-layer SPE methods need further optimization regarding appropriate sorbent combinations, loading volumes and elution conditions. The developed single-layer SPE methods can help to elucidate pollutions hotspots and discharge routes.
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.
Bacterial adhesion on surfaces of medical, water and food applications may lead to infections, water or food spoilage and human illness. In comparison to traditional static and macro flow chamber assays for biofilm formation studies, microfluidic chips allow in situ monitoring of biofilm formation under various flow regimes, have better environment control and smaller sample requirements.
In this work, a novel microfluidic platform is developed to investigate biofilm adhesion under precisely controlled bacteria concentration, temperature, and flow conditions. This platform central unit is a single-inlet microfluidic flow cell with a 5 mm wide chamber designed and tested to achieve ultra-homogenous flow in the central area of chamber. Within this area, defined microstructures are integrated that will disturb the homogeneity of the flow, thus changing bacterial adhesion pattern.
Here we present the monitoring of bacterial biofilm formation in a microfluidic chip equipped with a microstructure known as micro-trap. This feature is based on a 3D bacteria trap designed by Di Giacomo et al. and successfully used to sequester motile bacteria.
At first, fluorescent particles similar in size to Escherichia coli (E. coli) are used to simulate bacteria flow inside the flow cell and at the micro-trap. The turbulences induced by the trap are analyzed by imaging and particle tracking velocimetry (PTV). Secondly, the model strain E. coli TG1, ideal and well described for biofilm studies, is used to analyze biofilm formation in the micro-trap. Therefore, a stable fluorescent strain E. coli TG1-MRE-Tn7-141 is constructed by using Tn7 transposon mutagenesis according to the method described by Schlechter et al. Sequestering of E. coli cells within the micro-trap was followed using epifluorescence microscopy.
The novel microfluidic platform shows great potential for assessment of bacterial adhesion under various flow regimes. The performance of structural feature with respect to the generation of turbulences that promote or reduce bacterial adhesion can be systematically examined.
The combination of flow analysis and fluorescent strain injection into the microfluidic chip shows that the micro-trap is useful for capturing bacteria at defined positions and to study how flow conditions, especially micro-turbulences, can affect biofilm formation. It represents a powerful and versatile tool for studying the relation between topography and bacteria adhesion.
Gypsum (CaSO4∙2H2O) and anhydrite (CaSO4) are among the dominant evaporite minerals in the Atacama Desert [1]. They are distributed ubiquitously, and play a key role in local landscape evolution.
The formation mechanism of especially anhydrite has been a matter of scientific debate for more than a century [2]. To date, there exists no model that can reliably predict anhydrite formation at earth’s surface conditions. While thermodynamics favor its formation [3], it is hardly achieved on laboratory time scales at conditions fitting the Atacama Desert. Long induction times for nucleation have recently been modeled by Ossorio et al. [4]. However, anhydrite can be readily found in the Atacama Desert. Recently, the mineral was synthesized in flow-through reactors as a byproduct of K-jarosite dissolution at high water activity (aw=0.98) and room temperature [5], even-though the thermodynamic stability field begins only under a value of ~0.8. Additionally, recent studies investigated the nano-structure of various calcium-sulfates, which advocate for highly non-classical crystallization behavior [6]. The specific roles of particulates, ionic or organic reagents working as catalysts for the non-classical crystallization pathway remain to be determined.
Here, we present recent results from flow-through experiments as well as analyses of anhydrite samples from the Atacama Desert. Flow-through experiments were performed to systematically explore the domains of flow rate, composition, ionic-strengths and starting materials. Neither primary, nor secondary anhydrite was produced in any of these experiments. Analyses on Atacama samples reveal the existence of at least three distinct anhydrite facies, with differing mineralogy and micro- to nano-structures. The facies are (1) aeolian deposits with sub-µm grain sizes, (2) (sub-)surface nodules that formed from aeolian deposits and (3) selenites with secondary anhydrite rims. Possible mechanisms of their formation will be discussed.
Algal biofilm façades are an alternative to traditional green façades which can help to improve biodiversity and air quality within cities. They present a low maintenance approach in which subaerial algae are grown directly on concrete substrates. The intrinsic bioreceptivity of the substrate is a critical factor in successful facade colonisation. Existing research has identified several environmental and material properties which influence concrete bioreceptivity, however a consensus has yet to be made on which properties are most influential and how the interaction between properties may promote algal biofilm growth under specific conditions.
In construction and demolition waste (CDW) recycling, the preference to date has been to apply simple but proven techniques to sort and process large quantities of construction rubble in a short time. This contrasts with the increasingly complex composite materials and structures in the mineral building materials industry. An automated, sensor-based sorting of these building materials could complement or replace the practice of manual sorting to improve processing speed, recycling rates, sorting quality, and prevailing health conditions for the executing staff.
A joint project of partners from industry and research institutions approaches this task by investigating and testing the combination of laser-induced breakdown spectroscopy (LIBS) with near-infrared (NIR) spectroscopy and visual imaging. Joint processing of information (data fusion) is expected to significantly improve the sorting quality of CDW, and may enable the detection and separation of impurities such as SO3-cotaining building materials (gypsum, aerated concrete, etc.)
We present current advances and results about the methodological development combining LIBS with NIR spectroscopy and visual imaging. Here, applying data fusion proves itself beneficial to improve recognition rates. In the future, a laboratory prototype will serve as a fully automated measurement setup to allow real-time classification of CDW on a conveyor belt.
Aschen und Schlacken aus der thermischen Abfallbehandlung enthalten eine Vielzahl von Schwermetallverbindungen. Für Antimon, Chrom, Kupfer, Molybdän und Vanadium werden in der neuen Ersatzbaustoffverordnung Eluatgrenzwerte für die Verwertung festgelegt. Aschen und Schlacken werden aus der Abfallverbrennungsanlage nass ausgetragen und vor einer Verwertung in der Regel mehrere Wochen gelagert. Dabei finden hydraulische Reaktionen statt und enthaltenes CaO wird zu einem Großteil in Calciumcarbonat umgewandelt. Während wässrige Eluate von frischen Aschen pH-Werte von 12 und höher aufweisen, sind die Eluate nach einigen Wochen weniger stark alkalisch. Die gemessenen Schwermetallkonzentrationen sind daher dann auch deutlich niedriger, mit Ausnahme von Antimon (Sb) und Vanadium (V). Hier steigen die Konzentration mit der Lagerungsdauer. Grund sind sinkende Konzentrationen von Ca-Ionen, die sonst zu einer Ausfällung von Antimonaten und Vanadaten führen. Zu hohe Eluatwerte von Sb und V können durch Sorption an Eisenoxidverbindungen gemindert werden. Als besonders wirkungsvoll hat sich Schwertmannit (Eisen-Oxyhydroxysulfat) erwiesen. Es entsteht durch Oxidation von pyrithaltigem Material durch Mikroorganismen und wird deshalb in Gebieten gefunden, in denen Braunkohle abgebaut wurde, z.B. in der Lausitz. Weitere untersuchte Eisenoxidverbindungen waren Hämatit und Schlämme aus der Abtrennung von Eisen und Mangan in Wasserwerken.
Biocides are used for a wide range of purposes, including disinfectants or preservatives. They play a major role in the prevention of microbial infections in healthcare and animal husbandry. The use of biocides often leads to the discharge of active biocidal substances into wastewater streams, causing the exposure of wastewater microbial communities to subinhibitory concentrations. In turn, it is known that wastewater treatment plants (WWTP) are hotspots for antibiotic resistant bacteria. Since similar mechanisms confer resistance to biocides and antibiotics, exposure to biocides can result in co-selection of antibiotic resistant bacteria in WWTP Here, we want to investigate co-selection processes of antibiotic resistance in natural WWTP microbial communities upon biocide exposure. Microbial communities were sampled at the WWTP Ruhleben in Berlin and characterized regarding their susceptibility against different clinically relevant antibiotics. To investigate the link between biocide exposure and antibiotic resistance, changes in the susceptibility level after exposure to environmentally relevant concentrations of the commonly used biocide didecyldimethylammonium chloride (DDAC) will be determined by enumerating resistant and non-resistant E. coli on selective plates with and without antibiotics and DDAC. In case of antibiotics, clinical breakpoint concentrations according to EUCAST will be used to discriminate between susceptible and resistant strains. In case of DDAC (and biocides in general), clinical breakpoints do not exist. Therefore, we determined a cut-off concentration at which the majority of naturally-occurring E. coli strains cannot grow anymore based on (I) the MIC (minimal inhibitory concentration) distribution, and (II) by plating wastewater communities onto selective indicator agar plates loaded with increasing DDAC concentration. Additionally, antibiotic cross-resistance will be determined by spotting single colonies, isolated from DDAC-selective plates onto antibiotic plates. The results of our experiments will help to determine selective concentrations and to estimate the risk of antibiotic co-selection and cross-resistance in microbial WWTP communities upon biocide exposure.
Im Verbundprojekt R-Rhenania wird eine industrielle Demonstrationsanlage am Standort der Monoverbrennungsanlage Altenstadt der Firma Emter errichtet und im Jahr 2024 den Betrieb aufnehmen. Die vorhandene Rostfeuerung-Monoverbrennung wird so umgebaut, dass ein neues thermochemisches Verfahren integriert werden kann, welches hochwirksame und schadstoffarme Dünger produziert (bis zu 17.000 t/a). Die thermochemischen Produkte werden in Gefäß- und Feldversuchen im ökologischen Landbau auf ihre Düngewirkung getestet. Die Umweltverträglichkeit der Demonstrationsanlage wird untersucht, wie auch die Übertragbarkeit des Verfahrens auf weitere Regionen.
Background. Disinfection is an important mitigation strategy to control and prevent the spread of infections. Incomplete or incorrect usage of disinfection may promote evolution of resistance against disinfectants and antibiotics. Ideally, disinfection reduces the number of surviving bacteria and the chance for resistance evolution. Resistance describes the ability to grow in previously inhibitory concentrations of an antimicrobial, whereas tolerance is associated with enhanced survival of lethal doses. Individual bacteria from the same population can display considerable heterogeneity in their ability to survive treatment (i.e. tolerance) with antimicrobials, which can result in unexpected treatment failure.
Objective. In this study, we investigated six active substances of disinfectants, preservatives, and antiseptics against a population of E. coli to identify the presence of a tolerant subpopulation.
Methods. We performed time-kill experiments and analyzed the data with a mathematical model to statistically infer whether the data is best explained by the presence of a tolerant subpopulation.
Results. The analysis identified bimodal kill kinetics for benzalkonium chloride, didecyldimethylammonium chloride, and isopropanol. In contrast, kill kinetics by chlorhexidine, glutaraldehyde, and hydrogen peroxide were best explained by unimodal kill kinetics. These findings have implications for the risk of disinfection failure. In addition, we are currently performing adaptive laboratory evolution (ALE) experiments with the different disinfectants to investigate the potential consequences of tolerant sub-populations for the evolution of antimicrobial resistance and tolerance.