Sanitär- und Kommunaltechnik; Umwelttechnik
Filtern
Dokumenttyp
Sprache
- Englisch (5)
Schlagworte
- Fluorescence (3)
- Mercury (3)
- Dip-stick assay (1)
- Dyes/pigments (1)
- Fluorescence detection (1)
- Gated delivery system (1)
- Group profile (1)
- Hybrid nanoparticles (1)
- Mesoporous materials (1)
- Mesoporous silica materials (1)
Organisationseinheit der BAM
Invited for this month’s cover picture is the group of Dr. Knut Rurack at the Department of Analytical Chemistry; Reference Materials at the Bundesanstalt fuer Materialforschung und -pruefung (BAM) in Berlin (Germany). The cover picture shows how differences in color and fluorescence on a test strip can be easily read out with a mobile device. Two reference spots Frame the sensitive spot that indicates the presence of trace amounts of HgII below the threshold in a natural water sample. This dipstick contains a hybrid material that combines boron-dipyrromethene (BODIPY) probes sterically loaded into specifically tailored mesoporous silica particles, allowing for ultrasensitive HgII detection through enhanced fluorescence in a few seconds. The applicability in real water samples and fish extracts are also studied.
The synthesis, characterization, and application of mesoporous materials containing boron–dipyrromethene (BODIPY) moieties that allow the sensitive and selective detection of HgII in aqueous environments by fluorescence enhancement is reported. For this purpose, BODIPY dye I containing a thia‐aza crown ether receptor as the fluorescent probe for the detection of HgII in aqueous environments is encapsulated into mesoporous materials to avoid self‐quenching or aggregation in water. Determination of HgII is accomplished within a few seconds with high selectivity and sensitivity, reaching a limit of detection of 12 ppt. The determination of trace amounts of HgII in natural waters and in fish extracts is demonstrated by using our sensing material. The incorporation of the material into several μ‐PAD strips yields a portable, cheap, quick, and easy‐to‐handle tool for trace HgII analysis in water.
A novel mesoporous silica material containing boron–dipyrromethene (BODIPY) moieties (I) is employed for the detection of nerve agent simulants (NASs) and the organophosphate nerve or chemical warfare agents (CWAs) Sarin (GB), Soman (GD), and Tabun (GA) in aqueous environments. The reactive BODIPY dye with an optimum positioned hydroxyl group undergoes acylation reactions with phosph(on)ate substrates, yielding a bicyclic ring. Due to aggregation of the dyes in water, the sensitivity of the free dye in solution is very low. Only after immobilization of the BODIPY moieties into the silica substrates is aggregation inhibited and a sensitive determination of the NASs diethyl cyanophosphonate (DCNP), diethyl chlorophosphate (DCP) and diisopropyl fluorophosphate (DFP) possible. The signaling mode is a strong quenching of the fluorescence, reaching LODs in the pM range. The best performing hybrid material was singled out from a library of hybrid silicas varying in morphology and surface functionalization. The response to actual CWAs such as GB, GD, and GA has also been tested, offering similar behavior as for the simulants. The proposed reaction mechanism has been verified by investigation of other model materials, containing for instance BODIPY moieties without an optimum hydroxyl group (III) or a BODIPY dye with an all-aliphatic counterpart (IV). The latter can only form a monocyclic reaction product, showing much less reactivity as I. Assays with other possible competitors have been additionally carried out, showing favorably low cross-reactivities. Finally, the determination of NASs in several natural waters has been demonstrated.
The organophosphate nerve agents Tabun (GA), Sarin (GB) and Soman (GD) are among the most toxic chemical warfare agents (CWA) known, and exert their biological effects by irreversibly inhibiting acetylcholinesterase enzymes of the human nerve system. The use of these agents in the past century has killed millions of civilians around the world during World Wars I and II, and after that, approximately 40.000 tons of chemical ammunition were dumped into the Baltic Sea, containing ca. 13.000 tons of chemical warfare agents. Since their production, almost all the nations of the world have been strictly avoiding the development and use of CWA, participating in active destruction of CWA stockpiles, especially since the Chemical Weapon Convention (CWC) of 1993. However, CWA have been used in offensive ways against civilian population by terrorists, as for instance in the fatal Tokyo subway terror incident of 1995 or, most recently, against antigovernment demonstrators in Syria in 2013. Due to their higher toxicity and continuous use, it is therefore very important to develop simple and fast detection methods relying on new nerve agent sensing modalities for use in control and inspection.
A practically useful fluorescent probe must possess a rapid response and high sensitivity, and shall be implementable into easy-to-use devices for real time detection by untrained personnel. Taking into account this fact, in this work we have synthesized several mesoporous silica materials containing boron–dipyrromethene (BODIPY) moieties for the detection of nerve agents GA, GB and GD in the gas phase. Development of our system indicated that the most potent materials are able to respond to the presence of nerve agent simulants diethyl cyanophosphonate, diethyl chlorophosphate and diisopropyl fluorophosphate, which have to be used in a laboratory setting, yet also for the real nerve agents Sarin, Soman and Tabun, producing a strong quenching of the fluorescence. Furthermore, a portable device for the detection of GA, GB and GD in the gas phase has been prepared for in situ sensing and rapid screening applications, consisting of strips that are able to indicate the targets down to below 1 mgm-3 which is below the LD50 values.
A droplet-based microfluidic sensor was developed for the detection of Hg2+ traces in water. The approach uses gated mesoporous nanoparticles loaded with a fluorescent BODIPY dye. The squaraine-based gating mechanism is highly selective for Hg2+ and the indicator release mechanism ensures sensitive detection. The microfluidic system is modular and was assembled from simple PTFE/PFA tubes, while detection was realized with standard optomechanic, optic, and electronic parts. The sensor shows a stable response without memory effects and allows the detection of Hg2+ in water down to 20 ppt.