Sanitär- und Kommunaltechnik; Umwelttechnik
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (115) (entfernen)
Sprache
- Englisch (60)
- Deutsch (51)
- Französisch (2)
- Mehrsprachig (1)
- Polnisch (1)
Referierte Publikation
- nein (115) (entfernen)
Schlagworte
- TED-GC/MS (6)
- Microplastics (5)
- Mikroplastik (5)
- Ersatzbaustoffe (4)
- Microplastic (4)
- Abwasser (3)
- Antikörper (3)
- Bottom ash (3)
- Ectoine (3)
- Klärschlamm (3)
Organisationseinheit der BAM
- 4 Material und Umwelt (34)
- 1 Analytische Chemie; Referenzmaterialien (16)
- 6 Materialchemie (16)
- 6.6 Physik und chemische Analytik der Polymere (14)
- 4.3 Schadstofftransfer und Umwelttechnologien (12)
- 4.1 Biologische Materialschädigung und Referenzorganismen (8)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (8)
- 1.8 Umweltanalytik (7)
- 7 Bauwerkssicherheit (7)
- 8 Zerstörungsfreie Prüfung (6)
In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other.
Tracking waterborne microplastic (MP) in urban areas is a challenging task because of the various sources and transport pathways involved. Since MP occurs in low concentrations in most wastewater and stormwater streams, large sample volumes need to be captured, prepared, and carefully analyzed. The recent research in urban areas focused mainly on MP emissions at wastewater treatment plants (WWTPs), as obvious entry points into receiving waters. However, important transport pathways under wet-weather conditions are yet not been investigated thoroughly. In addition, the lack of comprehensive and comparable sampling strategies complicated the attempts for a deeper understanding of occurrence and sources. The goal of this paper is to (i) introduce and describe sampling strategies for MP at different locations in a municipal catchment area under dry and wet-weather conditions, (ii) quantify MP emissions from the entire catchment and two other smaller ones within the bigger catchment, and (iii) compare the emissions under dry and wet-weather conditions. WWTP has a high removal rate of MP (>96%), with an estimated emission rate of 189 kg/a or 0.94 g/[population equivalents (PEQ · a)], and polyethylene (PE) as the most abundant MP. The specific dry-weather emissions at a subcatchment were ≈30 g/(PEQ · a) higher than in the influent of WWTP with 23 g/(PEQ · a). Specific wet-weather emissions from large sub-catchment with higher traffic and population densities were 1952 g/(ha · a) higher than the emissions from smaller catchment (796 g/[ha · a]) with less population and traffic. The results suggest that wet-weather transport pathways are likely responsible for 2–4 times more MP emissions into receiving waters compared to dry-weather ones due to tire abrasion entered from streets through gullies. However, more investigations of wet-weather MP need to be carried out considering additional catchment attributes and storm event characteristics.
Estrogens are endocrine disrupting chemicals and of high concerns due to demonstrated harmful effects on the environment and low effect levels. For monitoring and risk assessment, several estrogens were included in the "watch list" of the EU Water Framework Directive which sets very low environmental quality standard (EQS) levels for Estrone (E1) and 17β-Estradiol (E2) of 0.4 ng L−1 and for 17α-Ethinylestradiol (EE2) of 0.035 ng L−1 requiring sensitive detection methods, as well as extensive sample preparation. A sensitive, derivatization-free, isotope dilution calibration HPLC-MS/MS method for a panel of 5 selected estrogens (including the 3 estrogens of the EU WFD watchlist), and a procedure for the reproducible preparation of a representative whole water matrix including mineral water, humic acids and solid particulate matter are presented. These are used in a diligent comparison of classical solid phase extraction (SPE) on hydrophilic-lipophilic balanced (HLB) phase to SPE on an estrogen-specific molecularly imprinted polymer phase (MISPE) for ultra-trace levels of the analytes (1–10 ng L−1). Additionally, a two-step procedure combining HLB SPE disks followed by MISPE is evaluated. The tow-step procedure provides superior enrichment, matrix removal and sample throughput while maintaining comparable recovery rates to simple cartridge SPE. Estimated method quantification limits (MQLs) range from 0.109–0.184 ng L−1 and thus meet EQS-levels for E1 and E2, but not EE2. The representative whole water matrix provides a reproducible comparison of sample preparation methods and lays the foundation for a certified reference material for estrogen analysis. The presented method will serve as the basis for an extended validation study to assess its use for estrogen monitoring in the environment.
Flexible, niedrigdichte Schäume aus Biokunststoffen im Extrusionsverfahren herzustellen war bisher industriell noch nicht möglich. Im Verarbeitungstechnikum Biopolymere des Fraunhofer IAP wurde in einem Projekt die Eignung von PBS-basierten Biokunststofftypen für Schaumanwendungen erforscht und weiterentwickelt.
Water treatment with activated carbon (AC) is an established method for the removal of organic micropollutants and natu ral organic matter. However, it is not yet possible to predict the removal of individual pollutants. An appropriate material characterization, matching adsorption processes in water, might be the missing piece in the puzzle. To this end, this study examined 25 diferent commercially available ACs to evaluate their material properties. Frequently reported analyses, including N2 adsorption/desorption, CHNS(O), point of zero charge (PZC) analysis, and X-ray photoelectron spectroscopy, were conducted on a selected subset of powdered ACs. Inorganic elements examined using X-ray fuorescence and X-ray difraction spectroscopy revealed that relative elemental contents were distinctive to the individual AC’s raw material and activation procedure. This study also is the frst to use thermogravimetric analysis (TGA) coupled to Fourier-transform infrared spectroscopy (FTIR) to conduct quantitative analyses of functional surface oxygen groups (SOGs: carboxylic acid, anhydride, lactone, phenol, carbonyl, and pyrone groups) on such a large number of ACs. The comparably economical TGA method was found to provide good surrogates for the PZC by pyrolytic mass loss up to 600 ◦C (ML600), for the oxygen content by ML1000 and for the carbon content by oxidation. Mass loss profles depict the AC’s chemistry like fngerprints. Furthermore, we found that SOG contents determined by TGA-FTIR covered a wide individual range and depended on the raw material and production process of the AC. TGA and TGA-FTIR might therefore be used to identify the suitability of a particular AC for a variety of target substances in diferent target waters. This can help practitioners to control AC use in waterworks or wastewater treatment plants.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and highthroughput mass quantification of microplastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermoanalytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg.
The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most
compact NIR spectrometers available.
An investigation of microplastic (MP) occurrence in a municipal wastewater treatment plant (WWTP) effluent with tertiary treatment was carried out. Representative sample volumes of 1 m3 were taken by applying a fractionated filtration method (500, 100, and 50 µm mesh sizes). The detection of MP mass fractions by thermal extraction desorption–gas chromatography/mass spectrometry (TED-GC/MS) was achieved without the previously required additional sample pretreatment for the first time. Different types of quantification methods for the evaluation of TED-GC/MS data were tested, and their accuracy and feasibility have been proven for real samples. Polyethylene, polystyrene, and polypropylene were identified in effluent samples. The polymer mass content varied significantly between 5 and 50 mg m−3. A correlation between the MP load and the quantity of suspended matter in the WWTP effluents, particle size distribution, particle type, and operation day (i.e., weekday, season, and capacity) was not found. It can be concluded that a meaningful assessment of WWTPs requires a comprehensive sampling campaign with varying operation conditions.
Rechtliche Vorgaben der Klärschlammverordnung und deren Auswirkungen auf die Phosphor-Rückgewinnung
(2022)
Im Abfalltechnik-Ausschuss der Bund/Länder-Arbeitsgemeinschaft Abfall (LAGA) wurde eine Vollzugshilfe zur Klärschlammverordnung erarbeitet, die nach Verabschiedung durch die Umweltministerkonferenz Mitte Mai 2020 als LAGA-Merkblatt M-39 veröffentlicht wurde. Im vorliegenden vierten Arbeitsbericht der DWA-Arbeitsgruppe KEK-1.1 werden verschiedene Aspekte der ab dem Jahr 2029 geltenden Regelungen aufgegriffen und damit einige Punkte des LAGA M-39 hinsichtlich der technischen Auswirkungen für den Kläranlagenbetreiber konkret ausgeführt.
Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt.
Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes.
Warum eine Kreislaufwirtschaft ohne Abfallverbrennung nicht funktionieren wird, beschreibt die Dechema im Positionspapier „Abfallverbrennung in der Zukunft“. Experten der Fachgruppe „Abfallbehandlung und Wertstoffrückgewinnung“ von ProcessNet, einer gemeinsamen Initiative der Dechema und der VDI-Gesellschaft Verfahrenstechnik und Chemieingenieurwesen, haben es erstellt.