To investigate the attachment behavior of bacteria, tailored surfaces are needed. Differences in the chemical charge of the substrate are varied by -COO-, -CH3, -OH, -NH3 terminated functional groups. Regular patterns of them on the surfaces enable bacteria to choose their preferred attachment sides. Tools to tailor the samples are µ-contact printing, self-assembled monolayers and physical vapor deposition. The same concept of preferred sides in patterned surfaces is transferred to the nano- and microroughness which is accomplished by using zinc oxide nanorods synthesis.
The characteristics of different molecules chosen as representatives for specific functionalities in conditioning layers play an important role on attachment behavior and later biofilm formation of bacteria. The chemical composition is a major component influencing the attachment but there is a conglomerate of influences.
Microbially influenced corrosion (MIC) of iron is usually attributed to sulfate-reducing microorganisms (SRM) which act upon the metal by the reactiveness of hydrogen sulfide, and by withdrawal of the available electrons in electrical contact with the metal. Methanogenic archaea are supposed to cause MIC. Because they do not produce hydrogen sulfide, withdrawal of electrons may be their main corrosive mechanism; however, mechanistic details and kinetics of the overall process are poorly understood. Precipitation of siderite (4Fe + 5HCO3 + 5H+ 4FeCO3 + CH4 + 3H2O) can lead to an insulating layer on the metal surface and lower the corrosion rate. Still, the extent of FeCO3 precipitation may be significantly influenced by environmental conditions such as pH and advective processes.
Microbially influenced corrosion (MIC) of iron is usually attributed to sulfate-reducing microorganisms (SRM) which act upon the metal by the reactiveness of hydrogen sulfide, and by withdrawal of the available electrons in electrical contact with the metal. Methanogenic archaea are supposed to cause MIC. Because they do not produce hydrogen sulfide, withdrawal of electrons may be their main corrosive mechanism; however, mechanistic details and kinetics of the overall process are poorly understood. Precipitation of siderite (4Fe + 5HCO3 + 5H+ 4FeCO3 + CH4 + 3H2O) can lead to an insulating layer on the metal surface and lower the corrosion rate. Still, the extent of FeCO3 precipitation may be significantly influenced by environmental conditions such as pH and advective processes.
Das Auftreten von Mikroplastik (MP) in aquatischen Ökosystemen ist bereits vielfältig dokumentiert. MP sind Kunststoffpartikel mit einer Größe kleiner als 5000 µm. Sie gelangen entweder als primäres MP (bspw. Zusätze in Kosmetikartikeln) oder als sekundäres MP (Fragmentierung größerer Kunststoffteile) in die Umwelt. Über die Existenz von Kunststoffpartikeln und deren Verbleib in terrestrischen Systemen ist wenig bekannt. Bis heute ist es unklar, ob MP im Boden durch Bodenerosion in die aquatische Umwelt transportiert wird und Boden somit als MP-Quelle für Gewässer fungiert, oder ob Partikel im Boden zurückgehalten werden und Boden eine MP-Senke darstellt. Hierzu sind aussagekräftige Messungen von Proben notwendig.
Das Fehlen harmonisierter Verfahren für die Probenahme, Probenaufbereitung und Detektion erschwert die aktuelle Diskussion. In den wenigen bisher veröffentlichten Studien fanden hauptsächlich spektroskopische Methoden wie FTIR- oder Raman-Mikroskopie als Detektionsverfahren Anwendung. Diese liefern in der Regel Aussagen über Partikelanzahlen.
Im vorliegenden Projekt soll als Analysemethode die von uns entwickelte ThermoExtraktionDesorption-GasChromatograpie-MassenSpektrometrie (TED-GC-MS) genutzt werden. Bei dieser Methode wird die Probe bis 600 °C erhitzt; die Zersetzungsgase werden auf einer Festphase sorbiert, anschließend in ein GS-MS-System überführt und dort desorbiert, getrennt und identifiziert. Die Methode erlaubt auf schnellem Wege über den Nachweis von spezifischen Zersetzungsprodukten die Identifikation einzelner Polymere, aber auch die quantitative Bestimmung des MP-Massegehaltes in einer Bodenprobe.
Ziel des vorliegenden Projektes ist die Entwicklung eines systematischen Protokolls zur Probenahme, Probenaufarbeitung und anschließenden Analyse mittels TED-GC-MS von MP in terrestrischen Proben. Neben der Erstellung einer systematischen Probenahmestrategie sind Probenaufarbeitungsschritte wie die Reduktion der anorganischen Matrix mittels Dichteseparation sowie die oxidative Zersetzung organischer Matrixbestandteile notwendig.
Im vorliegenden Tagungsbeitrag präsentieren wir die Anwendung der TED-GC-MS für die Bestimmung von MP in verschiedenen terrestrischen Umweltmatrizen.
The pollution of marine, limnic and terrestrial environments with plastic waste and the potential impact especially on biota and humans has received increasing attention in recent years. Special focus is on particles smaller than 5 mm, the so-called microplastics. Consequently, possible regulations of emission and remediation efforts require sound information on the occurrence and fate of microplastics in the respective environmental compartments.
Microplastics (MP) differ from classical organic pollutants in biota or the environment in that they do not consist of clearly defined low-molecular weight compounds but of polymer particulates with varying sizes and chemical compositions. This leads to specific challenges regarding the analytical techniques to be employed for their identification and quantification.
Microplastics are defined as polymer particle in the size range between 1 µm and 5 mm and cover a wide range of polymers such as polyethylene, polypropylene, polystyrene and polyethylene terephthalate in variable geometric shapes. Properties relevant for environmental microplastics are polymer type, particle form and size distribution, surface morphology (aging status) and total mass fraction contained in a given sample. Polymer identification and particle size estimation using optical methods (IR and Raman spectroscopy) are time consuming and complicated by surface characteristics as a result of weathering, soiling, and microbial colonisation. Total mass fractions of MP in environmental samples can be determined by thermo-analytical methods.
There are currently no standardised methods for sampling, sampling preparation, or detection of MP in environmental samples. So far, qualitative and quantitative investigations are done by research institutes and have not reached the routine laboratory community. The near future will see harmonisation efforts of MP mass fraction determination in environmental matrices by thermo-analytical procedures.
The immediate need for reference materials during method development and comparison is outlined with regard to relevant matrix/polymer compositions, existing regulations and currently achievable detection limits. Examples for solid environmental matrix reference materials are discussed regarding the challenges encountered with matrices and polymer types as well as homogeneity testing and property value characterisation.
Microbially influenced corrosion (MIC) of iron is usually attributed to sulfate-reducing microorganisms (SRM) which act upon the metal by the reactiveness of hydrogen sulfide, and by withdrawal of the available electrons (Fe → Fe²⁺ + 2e⁻ ; E° = 0.47 V) in electrical contact through surface attachment. Also methanogenic archaea are supposed to cause MIC. Because they do not produce hydrogen sulfide, withdrawal of electrons may be their main corrosive mechanism; however, mechanistic details and kinetics of the overall process are poorly understood. Precipitation of siderite (4Fe + 5HCO₃⁻ + 5H⁺ → 4FeCO₃ + CH₄ + 3H₂O) can lead to an insulating layer on the metal surface and lower the corrosion rate. Still, the extent of FeCO₃ precipitation may be significantly influenced by environmental conditions such as pH and advective processes.
To investigate the corrosive potential of methanogens, we studied strains isolated from marine sediments (Methanococcus maripaludis 14266, 2067, Methanobacterium-affiliated strain IM1), crude oil tanks (Methanococcus maripaludis Mic1c10, KA1) and the oral cavity (Methanobrevibacter oralis) in a closed (batch) culture, and in a sand-packed flow-through cell with pH control and simulation of a fluctuating environment. Results indicate that the rates of iron corrosion due to coupled methanogenesis (up to 0.3 mm/yr) are comparable to that caused by SRM. Surface analyses of the metal showed severe pitting. Such knowledge and deeper understanding also from an electrokinetic point of view may not only provide further models in microbial electrophysiology, but also contribute to mitigation strategies in MIC.
Nach einer Erläuterung der international üblichen Definitionen von Referenzmaterialien und Matrix-Referenzmaterialien erfolgt eine Zusammenfassung der spezifischen Anforderungen bei Herstellung und Charakterisierung. Weiterhin werden die unterschiedlichen Anforderungen an die Durchführung von Ringversuchen im Sinne eines Methodenvergleiches, einer Eignungsprüfung von Laboratorien und der Zertifizierung von Matrix-Referenzmaterialien gegenübergestellt. Für den aktuell geplanten ersten Ringversuch zur Quantifizierung von Mikroplastik in Schwebstoffen mittels thermischer Verfahren werden die konkreten technischen Bedingungen zur Herstellung entsprechender Referenzmaterialien einschließlich der Homogenitätsprüfung ihrer Mikroplastikgehalte dargestellt. Die Besonderheiten des Ringversuches vor dem Hintergrund einer Normung der eingesetzten Verfahren werden diskutiert.
Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensing devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary project presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field.
In this presentation, we give an overview over the recent developments on this topic in our groups. Highlights are hydrogen sulfide sensitive, BODIPY based transition metal complexes, which allow for a sensitive as well as selective detection of the toxic gas. In addition, we present a novel class of highly substituted BODIPY derivatives – pocket-BODIPYs – which are of a synthetically high versatility and can readily be modified to create pockets in the periphery of the molecule of defined geometries. This is illustrated on the successful encapsulation of benzene by a pocket-BODIPY derivative, confirmed by X-ray crystallographic analysis as well as by further spectroscopic and analytical methods.