Angewandte Physik
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (2) (entfernen)
Sprache
- Englisch (2)
Referierte Publikation
- ja (2) (entfernen)
Schlagworte
- Cytop (2) (entfernen)
Sensitivity of two commercial perfluorinated (PF) polymer optical fibers (POFs) to gamma radiation was measured, compared and exploited for dosimetry purposes. Fiber radiation induced attenuation (RIA) was found to be highly wavelength dependent and pronounced towards the UV part of the spectrum. PF-POFs were shown to be highly radiation sensitive and RIA-based on-line radiation monitoring with sensitivity as high as 135 dBm-1/kGy was demonstrated at 460 nm with co-extruded PF-POF. In addition, thanks to low inherent attenuation in the near-infrared region, possibility of distributed radiation detection with PF-POFs was demonstrated for the first time, utilizing optical time domain reflectometry.
The sensitivity of low-loss perfluorinated polymer optical fiber (PF-POF) to gamma radiation is investigated for on-line radiation monitoring purposes. The radiation-induced attenuation (RIA) of a commercial PF-POF based on Cytop material is measured in the visible spectral region. The fiber RIA shows strong wavelength dependence with rapid increase towards the blue side of the spectrum. The wide range of radiation sensitivities is available via careful selection of appropriate monitoring wavelength. The accessible sensitivities span from 1.6 ± 0.2 dBm-1/kGy measured at 750 nm to 18.3 ± 0.7 dBm-1/kGy measured at 420 nm. The fairly high radiation sensitivity as well as its wide tunability makes the fiber a promising candidate for a broad range of applications.