Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Erscheinungsjahr
- 2019 (229) (entfernen)
Dokumenttyp
Sprache
- Englisch (202)
- Deutsch (26)
- Mehrsprachig (1)
Schlagworte
- Mechanochemistry (14)
- Nanoparticles (13)
- Boehmite (12)
- Surface functionalization (12)
- Laser-induced periodic surface structures (LIPSS) (10)
- Nanocomposites (10)
- SAXS (10)
- In situ (9)
- TED-GC-MS (9)
- Applications (7)
- Epoxy (6)
- Femtosecond laser (6)
- Femtosecond laser ablation (6)
- Microplastics (6)
- Atomic Force Microscopy (AFM) (5)
- Corrosion (5)
- Cyclization (5)
- Electron microscopy (5)
- MALDI-TOF MS (5)
- MIC (5)
- Nanoparticle (5)
- Polylactide (5)
- Rigid amorphous fraction (5)
- Broadband dielectric spectroscopy (4)
- Catalysis (4)
- Klebfestigkeit (4)
- Laser-induced X-ray emission (4)
- Laser-induced periodic surface structures, LIPSS (4)
- Mikroplastik (4)
- Nanocomposite (4)
- Polymers of intrinsic microporosity (4)
- Radiation protection (4)
- Reference materials (4)
- Simulation (4)
- Specific heat spectroscopy (4)
- Thin films (4)
- Traceability (4)
- Ultrashort laser material interaction (4)
- XRD (4)
- Absorption edge tomography (3)
- Additive manufacturing (3)
- Analytik (3)
- Analytische Zentrifuge (3)
- AuNP (3)
- Bending modulus (3)
- Carbon nanotubes (3)
- Catalyst (3)
- Cement (3)
- Corrosion monitoring (3)
- Crosslinking (3)
- Dielectric spectroscopy (3)
- Discotic Liquid Crystals (3)
- Dosimetry (3)
- EPMA (3)
- Flash DSC (3)
- Geant4 (3)
- Haftfestigkeit (3)
- Harmonisation (3)
- Inter-laboratory comparison (3)
- LLG (3)
- MCS (3)
- MOF (3)
- Microdosimetry (3)
- Micromagnetism (3)
- Monte-Carlo simulation (3)
- Mueller-Matrix imaging ellipsometry (3)
- Nanofibers (3)
- OOMMF (3)
- Particle size distribution (3)
- Polycarbonate (3)
- Polymer (3)
- Polymer blends (3)
- Polymers (3)
- Polyurethane (3)
- Rigidity (3)
- Small-angle scattering (3)
- Spectroscopic ellipsometry (3)
- Spectroskopic Imaging (3)
- Synthesis (3)
- X-ray scattering (3)
- XPS (3)
- AFM (2)
- ALD-Hybridprozesse (2)
- Acoustic levitation (2)
- Additive Manufacturing (2)
- Adhäsion (2)
- Adsorbed layer (2)
- Al2O3-Schichten (2)
- Atomic Layer Deposition (2)
- BAMline (2)
- BDS (2)
- Biofilm (2)
- Biofilmbildung (2)
- Brechungsindex (2)
- C3A (2)
- CAT-Technologie (2)
- Copolymer (2)
- Corrosion inhibition (2)
- DNA (2)
- DNA damage (2)
- Delayed addition (2)
- EOS (2)
- EU FP7 project NanoValid (2)
- Early hydration (2)
- Electron probe microanalysis (EPMA) (2)
- Ellipsometrie (2)
- Energy deposit (2)
- Exchange interaction (2)
- Ferromagnetism (2)
- Glass transition (2)
- Haftvermittler (2)
- High-pressure (2)
- Interphase (2)
- Iridium-titanium mixed oxides (2)
- Kleb- und Haftfestigkeit (2)
- LEE (2)
- Landau Lifshitz equation (2)
- Laserschutz (2)
- Localised corrosion (2)
- Magnesium alloy (2)
- Magnetic moment (2)
- Materialbearbeitung (2)
- Mehrprobenprüfung (2)
- Mesoporous thin films (2)
- Metal–organic frameworks (2)
- Microstructure (2)
- Mikroskaliert (2)
- Molecular masses (2)
- Monte Carlo (2)
- Müller-Matrix-Ellipsometrie (2)
- NEXAFS (2)
- NanoSIMS (2)
- Nanocharacterisation (2)
- Nanomaterialien (2)
- Nanomechanics (2)
- Nanoplastics (2)
- Nanoskaliert (2)
- Nanostructure (2)
- Normung (2)
- OH radicals (2)
- Oberflächenenergie (2)
- Oberflächengeometrie (2)
- Object oriented micromagnetic framework (2)
- Oxidation (2)
- Polycarboxylate ether (PCE) (2)
- Polyethylene (2)
- Polymer bilayer coatings (2)
- Polymer nanocomposites (2)
- Radiationtherapy (2)
- Radioactive decay (2)
- Resonance frequency (2)
- Röntgenemission (2)
- Sekundärstrahlung (2)
- Silica nanoparticles (2)
- Silicon (2)
- Small angle scattering (2)
- Small-angle X-ray scattering (2)
- Software (2)
- Standardisation (2)
- Stochastic Landau Lifshitz Gilbert equation (2)
- Structural anomalies (2)
- Structural inhomogenities (2)
- Surface modification (2)
- Synchrotron (2)
- Synchrotron tomography (2)
- TMDSC (2)
- Temeprature scaling (2)
- Thermal degradation (2)
- Thin polymer films (2)
- Thin polymeric films (2)
- UV degradation (2)
- Ultrakurze Laserpulse (2)
- VAMAS (2)
- VSSA (2)
- Verbundfestigkeit (2)
- X-ray and electron diffraction (2)
- X-ray diffraction (2)
- low energy electrons (2)
- particle scattering (2)
- 2,6-diaminopyridine (1)
- 3D coherence scanning interferometry (CSI) (1)
- 3d structuring (1)
- AEROSIL® OX50 (1)
- AET (1)
- AFM-IR (1)
- AISI 304L (1)
- Acrylamide (1)
- Additiv (1)
- Additives (1)
- Admixtures (1)
- Advanced Materials (1)
- Advanced materials (1)
- Ageing (1)
- Alite (1)
- Alkoxysilanes (1)
- Alpha (1)
- Analysis (1)
- Anatase (1)
- Antibacterial (1)
- Antifouling surface coatings (1)
- Antifriction coefficient (1)
- Antiviral activity (1)
- Artificial weathering (1)
- Atomic force microscopy (1)
- Atomic fraction (1)
- Automation (1)
- Bacterial adhesion (1)
- Ball milling (1)
- Beamline (1)
- Bestimmung der Messunsicherheit (1)
- Beta decay (1)
- Biofunctional Molecules (1)
- Bloch wall (1)
- Boehmite alumina (1)
- Boehmite nanoparticles (1)
- Brachytherapy (1)
- Broadband dielectric microscopy (1)
- Bulk material (1)
- Bulk temperature (1)
- Bundesoberbehörden (1)
- Böhmit (1)
- C-C coupling (1)
- C3S (1)
- COK-12 (1)
- Cancer (1)
- Cancer treatment (1)
- Carbon fibers (1)
- Catalysts (1)
- Catechol (1)
- Cationic photocuring (1)
- Cell size (1)
- Cement admixtures (1)
- Cement hydration (1)
- Centrifugal Adhesion Testing (1)
- Centrifugal Adhesion Testing (CAT) (1)
- Centrifugal Force (1)
- Certified reference materials (1)
- Certified standards (1)
- Cluster (1)
- Co (1)
- Co-crystal (1)
- Cobalt (1)
- Cobalt and zinc oxides (1)
- Cocrystal (1)
- Coherent exchange (1)
- Comparability of Measurement Results (1)
- Compressive Stress (1)
- Conference (1)
- Coupled corrosive and mechanial load (1)
- Coupled corrosive/mechanical load (1)
- Cristobalite frameworks (1)
- Crosslinking density (1)
- Curie temperature (1)
- Curing (1)
- Curved surfaces (1)
- Cyclic (1)
- Cycloaliphatic epoxy oligosiloxane (1)
- Cycloalyphatic epoxy oligosiloxane (1)
- DIN EN ISO/IEC 17025:2018 (1)
- DRIFTS (1)
- Damping factor (1)
- Definition of nanomaterial (1)
- Degradation (1)
- Density Functional Theory (1)
- Deuterium (1)
- Diffraction (1)
- Dispersion of nano materials (1)
- Domain wall (1)
- Double complex salts (1)
- Dynamic heterogeneity (1)
- Dünne Schichten (1)
- EC4SafeNano (1)
- EMPIR (1)
- Electrical conductivity (1)
- Electrochemical deposition (ECD) (1)
- Electrochemical sensing (1)
- Electromagnetic radiation (1)
- Electromagnetic scattering (1)
- Electrospun fibers (1)
- Elemental composition (1)
- Ellipsometric porosimetry (1)
- Ellipsometry (1)
- Energetic Materials (1)
- Energiedissipation im Kontakt (1)
- Epoxy conversion degree (1)
- Epoxy-Anhydrid Duroplast (1)
- Europium (1)
- Exchange length (1)
- Exposed metal sites (1)
- FTIR (1)
- FTIR spectroscopy (1)
- Facilitated activation (1)
- Fast scanning calorimeter (1)
- Fast scanning calorimetry (1)
- Fast scanning calormetry (1)
- Fe (1)
- Fe-Ni (1)
- Fiber Bragg grating (FBG) (1)
- Filters (1)
- Fluid-flow (1)
- Fluorescence (1)
- Forschungsstrategie (1)
- Friction (1)
- Fully aromatic frameworks (1)
- Functionalized nanographene (1)
- GUM-compliance (1)
- Gamma (1)
- Gas separation membranes (1)
- Geant4-DNA (1)
- Geology (1)
- Ggraphene polymer nanocomposite (1)
- Glucose (1)
- Gold (1)
- Gold Nanoparticle (1)
- Gold Nanoparticles (1)
- Graphene (1)
- Graphene Oxide (1)
- Graphene polymer nanocomposite (1)
- Grating (1)
- Grenzfläche als Material (1)
- Hamonisierung (1)
- Heating oil tanks (1)
- High specific surface area (1)
- High-entropy alloys (1)
- Human umbilical cell adhesion (1)
- Hydration (1)
- Hydrogen (1)
- Hydrothermal synthesis (1)
- Härte (1)
- IIT (1)
- IR spectroscopy (1)
- ISO (1)
- ISO 14577 (1)
- ImAFM (1)
- Infrared nano AFM (1)
- Instrumented Indentation Testing (1)
- Instrumentierte Eindringprüfung (1)
- Instrumentierte Eindringprüfung (IIT) (1)
- Inter-laborator comparison (1)
- Interfaces (1)
- Intermodulation (1)
- Intermodulation AFM (1)
- Intermodulation-AFM (1)
- Introduction (1)
- Iron (1)
- Kinetics (1)
- Knoevenagel condensation (1)
- Kompaktierbarkeit (1)
- Kompressibilität (1)
- Korrosion (1)
- Korrosionsüberwachung (1)
- Kunststoff (1)
- LC / MALDI-TOF-MS coupling (1)
- LC x ESI-TOF-MS (1)
- LC-MS (1)
- LCCC (1)
- LEVASIL 50/50 (1)
- LL equation (1)
- Lactide (1)
- Landau Lifshitz Gilbert equation (1)
- Large-pore (1)
- Laser processing (1)
- Laser-induced nanostructures (1)
- Laser-modified surface (1)
- Layer-by-layer deposition (1)
- Leichtbau (1)
- Levitation (1)
- Linear polyglycerol (1)
- Liquid Crystals (1)
- Liquid crystals (1)
- Luminescence (1)
- MALDI TOF MS (1)
- MOF-74 (1)
- MPI (1)
- MPLS (1)
- Magnet coupling (1)
- Magnetic Nanoparticles (1)
- Magnetic anisotropy (1)
- Magnetic interacion (1)
- Magnetic nanoparticle (1)
- Magnetic nanoparticles (1)
- Magnetic swimmers (1)
- Magnetization dynamics (1)
- Magnetocoloric (1)
- Martensite (1)
- Mass spectrometry (1)
- Mass spectrometry of polymers (1)
- Material Science (1)
- Material characterization (1)
- Materials Science (1)
- Materials science (1)
- Mehr-Proben-Prüfverfahren (1)
- Melting (1)
- Mesoporous Silica (1)
- Mesoporous iridium-titanium mixed oxides (1)
- Mesoporous mixed metal oxide films (1)
- Messtechnik (1)
- Messunsicherheit (1)
- Metal carbides (1)
- Metal organic framework (1)
- Metal phosphonates (1)
- Metal reducing bacteria (1)
- Metal-organic-frameworks (1)
- Methanogens (1)
- Metrology (1)
- Microanalysis (1)
- Microbeam analysis (1)
- Microbial (1)
- Microbiologically Influrenced Corrosion (MIC) (1)
- Microbiologically influenced corrosion (1)
- Microencapsulation (1)
- Microplastic (1)
- Microwave synthesis (1)
- Milling (1)
- Mixed-linkers (1)
- Modelling (1)
- Moisture (1)
- Molecular mobility (1)
- Monte-Carlo (1)
- Mueller-Matrix Ellipsometry (1)
- Multiphoton laser structuring (1)
- Multivariate data analysis (1)
- Mussel-inspired adhesives (1)
- NP (1)
- Nano (1)
- Nano particle (1)
- Nano screening (1)
- NanoValid (1)
- Nanocasting (1)
- Nanoconfinement (1)
- Nanokomposit (1)
- Nanomaterial Properties (1)
- Nanomechanical properties (1)
- Nanometrology (1)
- Nanoparticle Characterization (1)
- Nanoparticle size measurement (1)
- Nanoparticular TiO2 (Anatase) (1)
- Nanoporous (1)
- Nanorods (1)
- Nanoscale (1)
- Nanosecond laser (1)
- Nanosecond laser irradiation (1)
- Nanostructure quantification (1)
- Nanotechnologie (1)
- Neel wall (1)
- Neuartige Materialien (1)
- Ni (1)
- Nickel (1)
- Niedrigenergie-Polymeren (1)
- Nitrene[2+1]cycloaddition (1)
- Nitrides (1)
- Non-destructiv testing (1)
- Non-destructive testing (1)
- Non-destructuve testing (1)
- Non-spherical shape (1)
- Nonclassical crystallization (1)
- Oberflächenanalytik (1)
- Oberflächenmesstechnik (1)
- Oberflächenpotential (1)
- Oberflächensteifigkeit (1)
- Oberflächentechnik (1)
- Optical fibers (1)
- Optical near field (1)
- Ordered mesoporous silica (1)
- Oxocobaltates (1)
- Oxygen Evolution Catalyst (1)
- Oxygen evolution reaction (1)
- Oxygen evolution reaction (OER) (1)
- Oxygen reduction reaction (1)
- P25 (1)
- PC characterisation (1)
- Pair Distribution Functions (1)
- Paramagnetism (1)
- Particle (1)
- Particle accretion (1)
- Particle size (1)
- Phase mask (1)
- Phase transition (1)
- Phosphinine (1)
- Phosphonates (1)
- Phosphorus (1)
- Photocuring (1)
- Photooxidation (1)
- Plasmon resonance (1)
- Plasmonic nanofocusing spectroscopy (1)
- Plastikstrategie (1)
- Polarization spectroscopy (1)
- Polyethylene glycol (1)
- Polymer aging (1)
- Polymer-based nanocomposites (1)
- Polymeric membrane (1)
- Polypropylene (1)
- Pore size tailoring (1)
- Post-modification by L-cysteine (1)
- Practical aspects (1)
- Pre-standardisation (1)
- Prediction (1)
- Protein (1)
- Proton cunductor (1)
- Prüftechnik (1)
- Qualitätssicherung (1)
- ROPPOC (1)
- Radiation damage (1)
- Radioactive NP (1)
- Real-time infrared spectroscopy (1)
- Reconstructed ion chromatograms (1)
- Recycling (1)
- Recycling-by-design (1)
- Reference Nanomaterials (1)
- Regulation (1)
- Resonance (1)
- Rh-Ir alloys (1)
- Rietveld (1)
- Ring-expansion polymerization (1)
- Ring-opening polymerization (1)
- Risstrajektorie (1)
- Rosin (1)
- SEC (1)
- SEM (1)
- SEM/EDS/STRATAGem (1)
- SIMS (1)
- SKPM (1)
- Salicylate (1)
- Scanning electrochemical microscope (SECM) (1)
- Scattering (1)
- Self-lubricating coating (1)
- Service life (1)
- Shape-controlled (1)
- Si-Ge (1)
- Silane (1)
- Single-source precursors (1)
- Size distribution (1)
- Small-angle x-ray scattering (1)
- Sonochemical synthesis (1)
- Specific Surface Area (BET) (1)
- Spectroscopic Imaging (1)
- Spektrale Ellipsometrie (SE) (1)
- Spin (1)
- Spontaneous emulsification (1)
- Stand der Normung (1)
- Standardization (1)
- Standardization of Ellipsometry (1)
- Steel (1)
- Stereocomplex (1)
- Stimuli-responsive polymers (1)
- Stochastic Landau Lifshitz equation (1)
- Structural defects (1)
- Structures under extreme conditions (1)
- Struvite (1)
- Sulfidation (1)
- Sulfur (1)
- Superparamagnetism (1)
- Surface Chemical Transformation (1)
- Surface characterization (1)
- Surface charge (1)
- Surface structures (1)
- Suzuki-Miyaura coupling (1)
- Synchrotron CT (1)
- Synchrotron radiation (1)
- TGA-FTIR (1)
- Tara Mediterranee (1)
- Temperature effects (1)
- Temperature modulated differential scanning calorimetry (1)
- Tensile Stress (1)
- Thermal extraction-desorption gas chromatography mass spectrometry (1)
- Thermo-responsive polymers (1)
- Thermogravimetry (1)
- Thermoplastics (1)
- Thin film systems (1)
- TiO2 (1)
- TiO2 nanoparticle (1)
- Tin(II)octanoate (1)
- Titanium dioxide (1)
- ToF-SIMS (1)
- Topometry (1)
- Topotactic phase transitions (1)
- Total scattering analysis (1)
- Toxicity (1)
- Transformation pathways (1)
- Tribology (1)
- Two-Photon Polymerization (1)
- Two-dimensional hexagonal boron nitride(h-BN) (1)
- UCST polymers (1)
- UV Weathering (1)
- Ultrafast scattering (1)
- Ultrashort laser pulses (1)
- Uncertainty budget (1)
- Uncertainty budgets (1)
- Wastewater (1)
- Wear (1)
- Weißlichtinterferenzmikroskopie (WLIM, 3D) (1)
- White light interference microscopy(WLIM) (1)
- X-Ray Imaging (1)
- X-Ray imaging (1)
- X-ray Absorption Spectroscopy (1)
- X-ray Photoelectron Spectroscopy (XPS) (1)
- X-ray absorption spectroscopy (1)
- X-ray imaging (1)
- X-ray spectroscopic techniques (1)
- X-ray spectroscopy (1)
- XAFS (1)
- XANES (1)
- Zeolitic Imidazolate Frameworks (1)
- Zeta potential (1)
- Zinc oxide (1)
- attraktive Wechelwirkung (1)
- beta particle (1)
- clustered nanoparticles (1)
- dielectric spectroscopy (1)
- gamma ray (1)
- gas separation membranes (1)
- mechanical properties (1)
- molecular mobility (1)
- nanoindentation (1)
- performance test (1)
- polymers (1)
- polymers of intrinsic microporosity (1)
- polynorbornenes (1)
- product specification (1)
- radiolysis (1)
- shape control (1)
- temeprature dependent exchange length (1)
- uncertainty (1)
- µ-XRF (1)
Organisationseinheit der BAM
- 6 Materialchemie (229) (entfernen)
Eingeladener Vortrag
- nein (95)
Ball mass is an important parameter that is known to have an influence on the outcome of a mechanochemical reaction induced by ball-milling. A standard way of modifying the ball mass is to change the size of the ball made of the same material. In this case, however, a change in mass is accompanied by a simulatneous change in the ball size. It is therefore not possible to disentangle the effects of mass and Surface area in these cases. In the present work we report the results of experiments with specially designed and manufactured balls in which (1) milling ball mass is held constant, but their size differs, and (2) the ball mass is altered, with the diameter of the milling ball being held constant. Using the cocrystallisation of theophylline + nicotinamide as a case study it was found that both diameter and ball mass play crucial roles in determining the rate of a mechanochemical reaction. For comparison, we have also used milling balls with the same size (different mass), and others with the same mass (different size) made of different materials, as would be “traditional”. It was found that, despite having the same size, the lightest milling ball (nylon) was the most efficient in initiating the co-crystallisation, presumably due to the sorption of EtOH. Hence, the results of this manuscript also demonstrate how milling ball material can in fact be the most influential parameter, and potentially counterintuitive to classical mechanics.
In this study, femtosecond laser-induced sub-micrometer structures are generated to modify polyethylene (PE) surface topographies. These surfaces were subjected to bacterial colonization studies with Escherichia coli and Staphylococcus aureus as test strains. The results reveal that the nanostructures do not influence S. aureus coverage, while the adhesion of E. coli is reduced.
The TED-GC-MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC-MS). This method is ideally suited for the analysis of polymers and their degradation processes. Here, a new entirely automated System is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. Strengths and limitations of the system configuration are elaborated via three examples focused on practical challenges in materials analysis and identification: i) separate analysis of the components of a wood-plastic-composite material, ii) quantitative determination of weight concentration of the constituents of a polymer blend and iii) quantitative analysis of model samples of microplastics in suspended particulate matter.
Auf dem Weg zu Industrie 4.0: Bestimmung von Messunsicherheitsbudgets in der Oberflächentechnik
(2019)
Vorgestellt wurde die Bestimmung von Messunsicherheitsbudgets für sehr unterschiedliche physikalische Größen, die in der Oberflächentechnik von hoher Relevanz sind: Stufenhöhe h, Schichtdicke d, Eindringhärte HIT und Haftfestigkeit. Die Unterschiede betreffen die Art der Prüfmethodik (optisch zerstörungsfrei vs. mechanisch invasiv/zer-störend), die laterale Größe des Integrationsgebietes der Messung (lokal:nano bis sub-mikro vs. global: mikro bis makro) und die Art der Bestimmung von Messunsicherheitsbudgets (physikalische Größen: direkt rückführbar; Werkstoffkenngröße: genormt; Systemkenngröße: genormt).
Im Rahmen von Industrie 4.0 werden ausgehend der geforderten Spezifikation des beschichteten Produkts (Mittelwert mit Vertrauensbereich oder Mindestwert) durchgehende Toleranzbänder zur Oberflächenmodifizierung/Beschichtung des Substrats, einhergehend mit Prozessfenstern, die diese Toleranzbänder garantieren, erforderlich, die zuverlässig erfasst werden müssen. Die Frage der anzuwendenden Mess- und Prüftechnik und die damit notwendige Betrachtung von Messunsicherheitsbudgets ist für die Digitalisierung von Konditionierungs-, Zustands-, Regel- und Steuergrößen unverzichtbar. Mit Blick auf die Einhaltung von Prozessfenstern und die dafür notwendige Prozessführung wird technologisches Kern-Know-how digitalisiert, das es unbedingt zu schützen gilt. Nur lokale Netze können diese Sicherheit garantieren, in globalen Netzen ist die Datensicherheit bestenfalls maximierbar.
Heating oil storage tanks made of polyethylene grades have been on the market in Germany since the early 1970s. To ensure safety, their replacement is recommended by tank manufacturers after a period of 30 years. Polyethylene is subject to ageing by alteration of the properties during its life cycle. The degree of degradation and the nature of the process mainly depend on the chemical alteration of the polyethylene, the wall thickness of the tank and the environmental conditions. There are no data available on the long-term behaviour of the polyethylene grades, especially after a service life of more than 30 years.
The aim of this investigation was to find a suitable test method to determine the factual degree of damage in comparison to the uncontaminated polyethylene grades. Material data of the used polyethylene grades are available because the BAM was the competent authority for the tests and expert reports for the approval of these tanks until the middle of the 1990s. Therefore, tank sections from the bottom, the shell and the roof of 22 individual storage tanks produced of polyethylene grades A and B have been examined by Melt Flow Rate (MFR) and Attenuated Total Reflectance (ATR). Their service life was in the range between 20 and 41 years.
The MFR measurements of the tank sections showed differences in the values depending on the weight which was used (5 kg or 21.6 kg). An increase of the MFR was determined for the samples of polyethylene grade A, whereas a reduction of the MFR values was measured for most samples of polyethylene grade B. This grade is mainly subject to the internal ageing by cross-linkages, increased degree of branched molecules and loss of the plasticizer.
ATR analysis exhibits an absorption band at 909 cm‒1 predominantly in samples of polyethylene grade A indicating chain scission and concomitantly formed terminal vinyl groups. This absorption band can be used for the characterization of the ageing of the polyethylene grades.
Applications on Surface Functionalization by Laser-Induced Periodic Surface Structures (LIPSS)
(2019)
In recent years, the understanding on the formation of laser-induced periodic surface structures (LIPSS) has led to an emerging variety of applications that modify the optical, mechanical and chemical properties of many materials. Such structures strongly depend on the used polarization and are formed usually after irradiation with ultrashort linearly polarized laser pulses. Some specific formation mechanisms to explain every situation are still to be uncovered, but the most accepted explanation relies on the interference of the incident laser beam with electromagnetic surface waves that propagate or scatter at the surface of the irradiated materials. This leads to an intensity modulation that is finally responsible for the selective ablation in the form of parallel structures with periodicities ranging from hundreds of nanometers up to some micrometers. The versatility when forming such structures is based on the high reproducibility with different wavelength, pulse duration and repetition rate laser sources, customized micro- and nanometric spatial resolutions and compatibility with industrially relevant processing speeds when combined with fast scanning devices. In this contribution, we review the latest applications in the rapidly emerging field of surface functionalization through LIPSS, including biomimetic functionalities on fluid transport, control of the wetting properties, specific optical responses in technical materials, improvement of tribological performance on metallic surfaces and bacterial and cell growth for medical devices among many others.
The performance of functional coatings and adhesively joined hybrid components relies strongly on the stability of the polymer-metal interface. With the increasing utilization of multi-material structures in the automotive and aerospace industry, it is of great scientific and technical interest to understand the processes leading to interface degradation and to develop novel strategies to increase corrosion and delamination resistance.
The aim of this project is to develop thin epoxy-based films and their carbon nanofiller loaded composites on aluminium alloy AA2024-T3 as a model system and to investigate their interfacial stability under corrosive and coupled corrosive-mechanical load. Spin coating was used for the layer-by-layer deposition of poly[(o-cresyl glycidyl ether)-co-formaldehyde] and poly-(ethylenimine) bi-layers. Atomic force microscopy (AFM) results indicate a very homogeneous and dense film with low surface roughness. Carbon nanofillers were introduced either by mixing into the coating components or in between individual layers to control the separation between the carbon nanofillers and alloy surface. The film chemistry and barrier properties were characterized by means of spectroscopic and electrochemical methods, respectively. The degradation and delamination behavior of the epoxy-based films was characterized by means of in situ AFM corrosion experiments. The quantitative imaging (QI) mode allowed the observation of hydrogen-generation induced blister formation during exposure to corrosive electrolyte and how the local corrosion processes evolved with exposure time. Complementary energy dispersive X-ray spectroscopy (EDX) analysis was performed to correlate the corrosion behavior with the different intermetallic particle chemistries and distributions. The presentation will summarize our results on the effect of interface chemistry and carbon nanofiller – alloy separation on the initiation of local corrosion processes on thin film covered AA2024-T3 aluminium alloys.
The antibacterial features of natural pine/spruce rosin are well established, yet the functionality in various thermoplastics has not been surveyed. This work focuses on the processing of industrial grade purified rosin mixed with polyethylene (PE), polypropylene (PP), polylactic acid (PLA), polyamide (PA) and corn starch based biopolymer (CS). Homopolymer masterbatches were extrusion-compounded and melt-spun to form fibres for a wide range of products, such as filters, reinforcements, clothing and medical textiles. Due to the versatile chemical structure of rosin, it was observed compatible with all the selected polymers. In general, the rosin-blended systems were shear-thinning in a molten condition. The doped fibres spun of PE and PP indicated adequate melt-spinning capability and proper mechanical properties in terms of ultimate strength and Young's modulus. The antibacterial response was found dependent on the selected polymer. Especially PE with a 10 wt% rosin content showed significant antibacterial effects against Escherichia coli DH5α and Staphylococcus aureus ATCC 12598 when analysed in the Ringer's solution for 24 h.
Die zunehmenden Nachweise von Kunststoffen in verschiedenen Umweltmedien erfahren in den letzten Jahren weltweit ein zunehmendes wissenschaftliches, gesellschaftliches und politisches Interesse. Besondere Aufmerksamkeit erfahren Kunststoffpartikel von 1-1.000 µm sogenanntes Mikroplastik. Es wurde mittlerweile in Wasser, Böden, Luft und Biota nachgewiesen. Obwohl die Wirkungen auf die natürlichen Umweltfunktionen noch unklar sind und kontrovers diskutiert werden, ist allein durch die ubiquitäre Präsenz eine systematische Erfassung von Eintragsquellen und Verbleib der Partikel über alle Umweltmedien notwendig, um Maßnahmen zur Reduktion der Einträge zu veranlassen.
Für eine zuverlässige Erfassung sind medienübergreifende Verfahren zu entwickeln, welche die drei analytischen Schritte, Probennahme, Probenaufbereitung und Detektion beinhalten. Die Verfahren adressieren unterschiedliche Zielgruppen, welche verschiedene analytische Informationen fordern. Für die akademische Bewertung werden Verfahren mit hohem analytischen Aufwand favorisiert, welche möglichst detaillierte Information über Partikelsorte, -größe, -zahl und -oberflächenbeschaffenheit geben. Im Gegensatz dazu, fordern Anwender aus der Praxis schnelle und einfache Monitoring Verfahren, welche die Bestimmung eines Massengehaltes, bzw. eines Grenzwertes zulassen. Allen ist gemeinsam, dass ein hoher interdisziplinärer Anspruch besteht, der sowohl technische Voraussetzungen zur repräsentativen Probennahme und die Limitationen von Detektionsverfahren berücksichtigt, als auch die Fachkompetenz von Biologen, Umweltwissenschaften, Analytiker und Polymerwissenschaftler einschließt.
Verfahren zum Mikroplastiknachweis müssen auch verschieden Proben mit sehr unterschiedlichen Gehalten an natürlicher Matrix gerecht werden. So müssen allein für Wasser Verfahren entwickelt werden, die Mikroplastik verschiedener Form (sphärische Partikel, komplexe Bruchstücke, Fasern) aus Medien mit sehr variablen Partikelanteil (u.a. Trinkwasser, Oberflächenwasser, Abwasser) repräsentativ erfassen sowie schnell und kostengünstig sind – einschließlich der notwendigen Probenaufbereitung. Die jeweiligen Detektionsverfahren müssen z.B. einzelne Partikel oder integrale Gehalte über drei Dekadenklassen für thermoplastische und insbesondere auch elastomere Partikelsorten erfassen können.
Polyether and -ester urethanes (PU) were exposed to artificial weathering at 40 °C and artificial UV radiation in a weathering chamber. In 3 parallel exposures, humidity was varied between dry, humid, and wet conditions. Material alteration was investigated by various analytical techniques like size exclusion chromatography
(SEC), liquid chromatography-infrared spectroscopy (LC-FTIR), thermal-desorption gas chromatography-mass spectrometry (TD-GC-MS), fluorescence mapping and dynamic mechanical analysis (DMA). Our results show that depending on the weathering conditions, different degradation effects can be observed. By means of SEC an initial strong decrease of the molar masses and a broadening of the mass distributions was found. After a material dependent time span this was followed by a plateau where molar mass changes were less significant. A minor moisture-dependent degradation effect was only found for polyester PU. Fluorescence measurements on two materials revealed an increase in the luminescence intensity upon weathering process reaching a saturation level after about 500 h. The changes in the optical properties observed after different exposure conditions and times were very similar. The TD-GC-MS data showed the fate of the stabilizers and antioxidant in the course of weathering. LC-FTIR measurements revealed a change in peak intensities and the ratio of urethane and carbonyl bands.
Due to the favorable properties of polymers, their production and thus their input into the environment has increased significantly in recent decades. Currently, FTIR or Raman spectroscopy are mainly applied for the analysis of microplastic particles (MP) in environmental samples. However, these methods have great difficulties in determining metrologically traceable MP values, especially with regard to the limiting values, as preferred in regulation. Therefore, we developed a systematic and fast thermoanalytical method called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which determines mass contents. Now the current goal is the determination of its process parameters.
This poster illustrates the theoretical requirements for MP analysis (left side) and contrast them with the current state of research (right side).Unexpected practical problems are presented and the relatively new method is discussed concerning the quality requirements of well-established methods such as LC-or GC-MS.
Analysis of elemental composition of Fe1-xNix and Si1-xGex alloy thin films by EPMA and µ-XRF
(2019)
The present study reports on measurements on thin Fe-Ni films on silicon and first-time results of analysis on Si-Ge thin films deposited on a non-conductive aluminium oxide Substrate by electron probe microanalysis (EPMA). Standard-based and standardless EPMA (with EDS) results were used in combination with the thin film analysis software Stratagem for the quantification.
Further, X-ray fluorescence analysis (XRF) can be used for the determination of elemental composition and thickness of such films as well. In this case, XRF with a μ-focus X-ray source (μ-XRF) attached to a SEM was applied. For quantification, a fundamental parameter (FP) approach has been used to calculate standard-based and standardless results.
Both thin film systems have been chosen as samples of an international round robin test (RRT) organised in the frame of standardisation technical committee ISO/TC 201 ‘Surface chemical analysis’, under the lead of KRISS. The main objective of the RRT is to compare the results of atomic fractions of Fe1-xNix and Si1-xGex alloy films obtained by different surface Analysis techniques, such as X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and secondary ion mass spectrometry (SIMS) applied in the depth-profiling operation mode.
Five samples of different atomic fractions of each thin film system, i.e., Fe1-xNix and Si1-xGex, have been grown by ion beam sputter deposition on silicon and Al2O3 wafers, respectively. Reference FeNi and SiGe films with well-known elemental composition and thickness have been also supplied for standard-based analysis. An excellent agreement has been obtained between the atomic fractions determined by EPMA and µ-XRF with the KRISS certified values.
Porous materials play an important role in several fields of technology, especially for energy applications like photovoltaics, electrolysis or batteries. The activity of porous films is affected by properties like porosity, film thickness, chemical composition of the material as well as the crystallinity of the framework. The complex morphology of such porous films constitutes a challenge even for modern analytical techniques and requires new approaches employing the combination/complementation of data of different analytical methods. In this contribution we characterize thin mesoporous iridium-titanium mixed oxide film properties by Electron Probe Microanalysis (EPMA) with energy dispersive X-ray spectroscopy (EDS) at an SEM.
Porous materials play an important role in several fields of technology, especially for energy applications like photovoltaics, electrolysis or batteries. The activity of porous films is affected by properties like porosity, film thickness, chemical composition of the material as well as the crystallinity of the framework. The complex morphology of such porous films constitutes a challenge even for modern analytical techniques and requires new approaches employing the combination/complementation of data of different analytical methods. In this contribution we characterize thin mesoporous iridium-titanium mixed oxide film properties by Electron Probe Microanalysis (EPMA) with energy dispersive X-ray spectroscopy (EDS) at an SEM.
Porous materials play an important role in several fields of technology, especially for energy applications like photovoltaics, electrolysis or batteries. The activity of porous films is affected by properties like porosity, film thickness, chemical composition of the material as well as the crystallinity of the framework. The complex morphology of such porous films constitutes a challenge even for modern analytical techniques and requires new approaches employing the combination/complementation of data of different analytical methods. In this contribution we characterize thin mesoporous iridium-titanium mixed oxide film properties by Electron Probe Microanalysis (EPMA) with energy dispersive X-ray spectroscopy (EDS) at an SEM.
3D microstructures with sub-micron resolution can be manufactured in additive manner applying multi-photon laser structuring technique. This paper is focused on the incorporation of superparamagnetic iron oxide nanoparticles into the photoresist in order to manufacture micrometer-sized devices featuring a magnetic moment. The aim of the project is to achieve untethered actuation of the presented objects through externally applied magnetic fields. Future medical application scenarios such as drug delivery and tissue engineering are targeted by this research.
Im Fokus des Vorhabens steht das mit dem Innovationspreis Berlin-Brandenburg 2012 ausgezeichnete Mehr-Proben-Prüfverfahren zur Festigkeitsprüfung unter Verwendung einer analytischen Zentrifuge mit dem Ziel des Einsatzes in der Qualitätssicherung. Nachdem im MNPQ-Projekt QUO VADIS die grundsätzliche Anwendbarkeit der Zentrifugentechnologie auf Beanspruchungen auf Zug (Kleb-, Haft- und Verbundfestigkeit) nachgewiesen worden war, wurden im Vorhaben QUO VADIS PLUS folgende erweiterte Prüfszenarien und technische Weiterentwicklungen etabliert: 1. Beanspruchung auf Druck (Härte von Materialien, Kompressibilität von Schäumen, Kompaktierbarkeit von Pulvern), 2. Erweiterung der Beanspruchung auf Zug (Kombination von Normal- und Lateralkräften), 3. Erweiterung auf die Bewertung plasto-elastischenn Materialverhaltens, 4. Vermeidung von Schockwellen im Hochlastbereich
L-Lactide was polymerized in bulk with tin(II)2-ethylhexanoate SnOct2) as catalyst and salicylic acid as cocatalyst. The Lac/Cat ratio, Cocat/Cat ratio, temperature and time were varied. Increasing Cocat/Cat ratios reduced both,polymerization rate and molecular weight. However,under optimized conditions high molar mass (Mw up to 178,000), colorless, cyclic polylactides were formed in a short time. A few polymerizations performed at 160 and 180°C with the combination of SnOct2 and silylated salicylic acid gave similar results. Neat tin II) salicylate was prepared from SnOct2 and used for REPs of L-lactide in bulk, but the results were not better than those obtained from combinations of SnOct2 and salicylic acid. Furthermore, dibutyltin salicylate was synthesized and used as catalyst for polymerizations of L-lactide in bulk at temperatures varying from 102 to 160°C. Cyclic polylactides with Mw’s up to 40,000 were the main reaction products. At 100–102°C a predominance of odd-numbered cycles was found proving a REP mechanism.
Structural modularity of polymer frameworks is a key advantage of covalent organic polymers, however, only C, N, O, Si and S have found their way into their building blocks so far. Here, we expand the toolbox available to polymer and materials chemists by one additional nonmetal, phosphorus. Starting with a building block that contains a λ⁵‐phosphinine (C₅P) moiety, we evaluate a number of polymerisation protocols, finally obtaining a π‐conjugated, covalent phosphinine‐based framework (CPF‐1) via Suzuki‐Miyaura coupling. CPF‐1 is a weakly porous polymer glass (72.4 m2 g‐1 N2 BET at 77 K) with green fluorescence (λmax 546 nm) and extremely high thermal stability. The polymer catalyzes hydrogen evolution from water under UV and visible light irradiation without the need for additional co‐catalyst at a rate of 33.3 μmol h‐¹ g‐¹. Our results demonstrate for the first time the incorporation of the phosphinine motif into a complex polymer framework. Phosphinine‐based frameworks show promising electronic and optical properties that might spark future interest in their applications in light‐emitting devices and heterogeneous catalysis.
The precise analysis of cation diffusion profiles through corrosion scales is an important aspect to evaluate corrosion phenomena under multicomponent chemical load, as during high‐temperature corrosion under deposits and salts. The present study shows a comprehensive analysis of cation diffusion profiles by electron microprobe analysis and microbeam X‐ray absorption near edge structure (µ‐XANES) spectroscopy in mixed oxide/sulfide scales grown on Fe–Cr model alloys after exposing them to 0.5% SO2. The results presented here correspond to depth‐dependent phase identification of oxides and sulfides in the corrosion scales by µ‐XANES and the description of oxidation‐state‐dependent diffusion profiles. Scales grown on low‐ and high‐alloyed materials show both a well‐pronounced diffusion profile with a high concentration of Fe3+ at the gas and a high concentration of Fe2+ at the alloy interface. The distribution of the cations within a close‐packed oxide lattice is strongly influencing the lattice diffusion phenomena due to their different oxidation states and therefore different crystal‐field preference energies. This issue is discussed based on the results obtained by µ‐XANES analysis.
Mesoporous phosphates are a group of nanostructured materials with promising applications, particularly in biomedicine and catalysis. However, their controlled synthesis via conventional template-based routes presents a number of challenges and limitations. Here, we show how to synthesize a mesoporous Magnesium phosphate with a high surface area and a well-defined pore structure through thermal decomposition of a crystalline struvite (MgNH4PO4·6H2O) precursor. In a first step, struvite crystals with various morphologies and sizes, ranging from a few micrometers to several millimeters, had been synthesized from supersaturated aqueous solutions (saturation index (SI) between 0.5 and 4) at ambient pressure and temperature conditions. Afterwards, the crystals were thermally treated at 70–250 °C leading to the release of structurally bound water (H2O) and ammonia (NH3). By combining thermogravimetric analyses (TGA), scanning and transmission electron microscopy (SEM, TEM), N2 sorption analyses and small- and wide-angle X-ray scattering (SAXS/WAXS) we show that this decomposition process results in a pseudomorphic transformation of the original struvite into an amorphous Mg-phosphate. Of particular importance is the fact that the final material is characterized by a very uniform mesoporous structure with 2–5 nm wide pore channels, a large specific surface area of up to 300 m2 g−1 and a total pore volume of up to 0.28 cm3 g−1. Our struvite decomposition method is well controllable and reproducible and can be easily extended to the synthesis of other mesoporous phosphates. In addition, the so produced mesoporous material is a prime candidate for use in biomedical applications considering that Magnesium phosphate is a widely used, non-toxic substance that has already shown excellent biocompatibility and biodegradability.
Laser-induced periodic surface structures (LIPSS, ripples) are a universal phenomenon that can be observed on almost any material after the irradiation by linearly polarized laser beams, particularly when using ultrashort laser pulses with durations in the femtosecond to picosecond range.
During the past few years significantly increasing research activities have been reported in the field of LIPSS, since their generation in a single-step process provides a simple way of nanostructuring and surface functionalization towards the control of optical, mechanical, biological, or chemical surface properties. In this contribution the mechanisms of formation and current applications of LIPSS are reviewed, including the colorization of technical surfaces, the control of surface wetting properties, the mimicry of the natural texture of animal integuments, the tailoring of surface colonization by bacterial biofilms, the advancement of medical pacemakers, and the improvement of the tribological performance of nanostructured metal surfaces.
A look inside nanoparticles
(2019)
Small-angle scattering is the method of choice when it comes to obtaining information about the interior of nanoparticles. The aim is to make nanotechnology safer. While the use of small-angle neutron scattering (SANS) is limited to a few instruments in the world, small-angle X-ray scattering (SAXS) is widely accessible, with an upward trend. The example of core-shell particles shows how simple their analysis is with data from an Anton Paar laboratory system. Here, SAXS is a central tool for the development of new reference materials based on poly(methyl) acrylate-PVDF core-shell particles. The dimensions of the cores and shells can be precisely determined. A detailed analysis makes it possible to show that the cores contain fluorinated and nonfluorinated polymers, whereas the shell consist only of PVDF. This core-shell particles with a diameter around 40 nm show a significantly higher PVDF beta phase content than the PVDF homopolymer when using an emulsion polymerization technique. This finding is of importance with respect to applications in electroactive devices.
The mechanochemical formation of the ionic cocrystals of glucose (Glc) and sodium salts Glc2NaCl·H2O (1) and Glc2NaX (X = Br (2), I (3)) is presented. Products are formed by co-milling Glc with three sodium salts (NaCl, NaBr, NaI). The ionic cocrystals were obtained under both neat grinding and liquid-assisted grinding conditions, the later found to accelerate the reaction kinetics. The crystal structures of the ionic cocrystals (2) and (3) were solved from powder X-ray diffraction data. The structure solution contrasts with the structure of Glc2NaCl·H2O (1) where the electron density at three halide crystallographic sites is modeled as of being the intermediate between water molecule and a chloride ion. The reaction pathways of the three ionic cocrystals were investigated in real time using our tandem approach comprising a combination of in situ synchrotron powder X-ray diffraction and Raman spectroscopy. The results indicate the rapid formation of each cocrystal directly from their respective starting materials without any intermediate moiety formation. The products were further characterized by DTA-TG and elemental analysis.
A novel cop olyme r based on supramolecular motif2,6-diaminopyridin e and water-soluble acrylamide, poly[N-(6-ace tamidopyridin-2-yl) acrylamide-co-acrylamide], was synthe-size d via rev ersible addi tion–fragmentation chain transfer (RAFT)polymerization with various monomer compositions. The thermo-respon sive behavior of the copolymers was studied by turbidime-try and dynamic light scattering (DLS). The obtained copolymersshowed an upper critical solution temperature (UCST)-typ e phasetransition behavior in water and electrolyte solution. The phasetransition temperature was found to increase with decreasingam ount of acrylamide in the copolymer and increasing concentra-tion of the solution. Furth ermore, the phase transition temperatureva ried in aqueous solutions of electrolytes according to the naturean d concentration of the electrolyte in accordance with theHoffmeister series. A dramatic solvent isotope effect on thetransition temperature was o bserved in this study, as the transitiontemperature was almost 10–12C higher in D2OthaninH2Oatthesame concentration and acrylamide co mposition. The size of theaggregates below the transition temperature was larger in D2Ocompared to that in H2O that can be explained by deuterium iso-tope effect. The thermoresponsive behavior of the copolymers wasalso investigated in different cell medium and found to be exhibitedUCST-type phase transition behavior in different cell medium.Such behavior of the copo lyme rs can be useful in many a pplica-tions including biomedical, microfluidics, optical materials, and indrug delivery.