Ingenieurwissenschaften und zugeordnete Tätigkeiten
Filtern
Dokumenttyp
- Vortrag (18)
- Beitrag zu einem Tagungsband (11)
- Zeitschriftenartikel (4)
- Posterpräsentation (3)
Sprache
- Englisch (36) (entfernen)
Schlagworte
- NDT (36) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (7)
- 8.4 Akustische und elektromagnetische Verfahren (4)
- 8.0 Abteilungsleitung und andere (3)
- 9 Komponentensicherheit (3)
- 5 Werkstofftechnik (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.9 Chemische und optische Sensorik (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
Eingeladener Vortrag
- nein (18)
Unilateral thermal exposure of concrete building components induces moisture transport processes that have a significant influence on the spalling behaviour of dense high-strength concrete (HSC). These transport processes are based on evaporation and condensation mechanisms of liquid and gaseous water in the pores as well as the chemically bound water within the concrete. The low permeability of HSC and the formation of a saturated zone within building components (also known as a moisture clog) leads to high water-vapour pressures, which contributes to explosive spalling. The formation of these pressures has already been verified by means of pore-pressure measurement techniques. In addition, the redistribution of the moisture within concrete specimens subject to unilateral thermal exposure has been demonstrated on fractured surfaces. Investigations by means of the nuclear magnetic resonance (NMR) relaxometry technique and neutron radiography have shown one-dimensional changes in moisture distribution during thermal exposure.
However, none of these methods has been able to depict the moisture distribution in three dimensions (3D), so the link between pore size, concrete micro-structure and moisture content is missing. The research project presented in this paper aims to fill this gap by developing a new multi-level test methodology to characterise non-destructively the temporal course of spatial moisture distribution during unilateral thermal exposure. The procedure used during this programme included the collection of X-ray 3D-computed tomography (CT) measurements using a miniaturised specimen subjected to in-situ thermal exposure and the comparison of those CT results with the results of one-dimensional NMR-relaxometry before and after the heating process.
In the first step, a mobile heating device was developed, built and tested. To simulate a unilaterally-heated construction component, a cylindrical specimen made of HSC (Ø = 40 mm, L = 100 mm) was cast into an impermeable glass ceramic shell. The ceramic shell ensured a one-dimensional moisture flux and limited the thermal expansion of the concrete. An additional high-temperature wool (HTW) insulating shell ensured a one-dimensional heat flux. The heating device, which operated using infrared radiation (IR), allowed the unilateral heating of the specimens up to 300 °C using variable heating regimes.
In the second step, the mobile heating device was integrated into the CT-scanner, which enabled the collection of measurements before, during and after heating. By subtraction of successive 3D-CT images, X-ray attenuation differences could be resolved three-dimensionally in the specimen and interpreted as changes in the moisture content.
Initial results show that this test methodology can monitor the 3D changes of moisture content inside the specimen during thermal exposure. It enables the researcher to visualise areas with moisture accumulation as well as dehydrated areas inside the specimen. Comparative one-dimensional NMR-relaxometry measurements confirm the results of the CT image analysis.
It is known that the spalling risk of dense, high-strength concretes (HSC) can be reduced by the addition of polypropylene (PP) fibres and, in particular, PP-fibres that have been pre-treated using electron irradiation. It is presumed that the enhanced reduction in spalling resulting from electron irradiation pre-treatment of the fibres can be attributed to enhanced penetration of the molten fibre material into the micro-cracks around the fibres, due to their significantly decreased viscosity. So far there has been no experimental evidence for this. Against this background, this paper gives a com-parative analysis of the mode of action of PP-fibres with and without pre-treatment using multi-scale test methodology.
Initially, fire tests on small-scale building components with accompanying damage monitoring veri-fied that the amount of PP-fibres can be halved by using pre-treated PP-fibres without reducing the fire performance of HSC. Detailed investigations of PP-fibres carried out in a completed research project funded by DFG (the German Research Foundation) using digital scanning calorimetry and thermogravimetry measurements (DSC/TG) as well as viscometer measurements showed that the pre-treatment has no significant influence on the melting temperature of the PP-fibres. However, a drastic reduction of the melt viscosity due to the electron irradiation was detectable. Additional dila-tation tests showed that the expansion behaviour of both fibre types and their melts do not differ significantly [1]. Rather, both fibre types generate high pressures when their thermal expansion is hindered. Further detailed investigations by means of continuous heating tests with a low heating rate were carried out on separately produced concrete cylinders. These tests showed that the pre-treatment of the PP-fibres causes earlier dehydration in conjunction with stagnation of thermal expansion of the concrete cylinders (temperature reduction from 180 °C to 170 °C). This is accompanied by in-creased acoustic emission activity during the thermal expansion tests. This leads to the assumption that the pre-treatment of PP-fibres results in earlier micro-crack development. However, it was not possible to confirm this assumption by microscopic examination of drilling cores with a diameter of 30 mm exposed to defined temperatures in the range between 150°C and 300°C. Microscopic obser-vations and additional X-ray 3D computed tomography (3D-CT) scans on miniaturised drilling cores exposed to temperature cycles showed a similar networking of fibre beds by means of micro-cracks in HSC for both fibre types. However, energy dispersive X-ray spectroscopy and wavelength disper-sive X-ray spectroscopy revealed fundamental differences in the penetration capacity of the fibre melts of the two fibre types. The increased penetration of the pre-treated PP-fibre melt revealed in these tests, confirms the initial working hypothesis.
Today, it is an established fact that the capability of the non-destructive testing (NDT) to find flaws can be properly addressed only in terms of probability of detection (POD). The probabilistic, signal-response model, introduced in 1980s, was developed with experimental observation of eddy-current inspections of flat plate samples, containing surface breaking cracks. A linearity between the peak voltage measured by the testing system, and the crack depth was observed. The influence of the crack depth was therefore seen as the major influencing factor for the POD, whereas other factors merely caused the variability in the measurement. This model has proven itself valid for those inspection cases where there is only one main influencing factor on the POD (usually the flaw size) and other factors have a lesser influence. But with increasing requirements to quantify the capability of NDT systems in complex inspection situations, where several factors have a major influence on the POD, it has become clear that the applicability of this simple model has reached its limits. In disregard to its limitations, this model is regularly applied to those situations in which its fundamental assumptions are invalid, forcing evaluators and NDT researchers into attempts to fit the data to an unsuitable model, instead of fitting an appropriate model to the data.
The multiparameter POD model, developed in the early 2010s, enables more factors that influence detection to be simultaneously analysed, making the POD a function of multiple factors. The model is based on the inspection’s physical model, to describe the influence of different factors on the response signal. Measurement variability is obtained from the experiment. Using this model assisted determination of the POD, the necessary number of flaws for evaluation is reduced and a more comprehensive understanding of the inspection is obtained. Several examples of the successful application of the multi-parameter POD model in different fields will be presented.
Evaluation of high spatial resolution imaging of magnetic stray fields for early damage detection
(2016)
Metal magnetic memory (MMM) technique with associated ISO 24497-1:3 is gaining considerable interest in the magnetic NDT community. In contrast to traditional Magnetic Flux Leakage (MFL) testing, the inspection objects are not intentionally magnetized by an external magnetic field. Due to the physical coupling between mechanical stress and magnetization of ferromagnetic materials, it is assumed that the distribution of the residual MFL correspond to the internal stress of the specimen, or in the most general sense, to a degradation of the material.
Usually, MMM measurements are performed by relatively bulky magnetic inspection sensors. The evaluation of local magnetic field distribution is limited thereby. Highprecision GMR (Giant Magneto Resistance) measurements in the micrometer regime can provide a higher degree of information due to better spatial resolution.
We present a concise summary of studies on the correlation of magnetic structure and microstructure of steels. In particular, we compare residual stress measurements in S235JRC steel welds by means of neutron diffraction with high resolution magnetic field mappings. Results indicate a qualitative correlation between residual stresses and local stray field variation. In addition, stray field measurements of plastically deformed specimens for quasi-static and cyclic loading cases are discussed. The present study concludes that GMR sensors can detect inhomogeneous plastic deformations of S235JR steel in a very early stage, without specific signal processing according to the ISO 24497-1:3.
The canister for the permanent storage of spent nuclear fuel used by SKB in Sweden consists of a cast iron insert surrounded by a five centimetre thick shell of copper. It is a safety critical component and in order to secure long-term structural integrity non-destructive methods are used to inspect 100% of the volume of each canister, before it is disposed of in the repository. One of the critical components that requires inspection is a sealing weld, joining the copper tube and the lid. The friction stir weld is inspected using an ultrasonic phased array system. The area of the weld is inspected with several inspection channels with different angles and varying coverage. To make sure that no defects that might occur in the weld are overseen, the reliability of the inspection must be quantified. The reliability of NDT is usually quantified with the probability of detection curves. The influence of the parameters that might influence the POD of the flaws in the weld is investigated analysing the experimental results, as well as with a help of a numerical simulation of the inspection.
The canister for the permanent storage of spent nuclear fuel used by SKB in Sweden consists of a cast iron insert surrounded by a five centimetre thick shell of copper. It is a safety critical component and in order to secure long-term structural integrity non-destructive methods are used to inspect 100% of the volume of each canister, before it is disposed of in the repository. One of the critical components that requires inspection is a sealing weld, joining the copper tube and the lid. The friction stir weld is inspected using an ultrasonic phased array system. The area of the weld is inspected with several inspection channels with different angles and varying coverage. To make sure that no defects that might occur in the weld are overseen, the reliability of the inspection must be quantified. The reliability of NDT is usually quantified with the probability of detection curves. The influence of the parameters that might influence the POD of the flaws in the weld is investigated analysing the experimental results, as well as with a help of a numerical simulation of the inspection.
Currently at Deutsche Bahn (DB) ultrasonic inspections in maintenance procedures for wheelset axles with a bore hole are, to the greatest possible extent, carried out using automated ultrasonic inspection system. Although the acceptance levels are in accordance with DIN 27201 part 7, the testing results have shown in recent years that in the case of true indications, the effective defect sizes were far below the level of acceptance. Due to this experience it can be assumed that the automated ultrasonic inspection systems are testing substantially more sensitively than required. This increased sensitivity leads to an increase in false indications, generally resulting in the unnecessary demounting of wheelsets. In Research cooperation between Federal Institute for Materials Research and Testing (BAM) and DB the effective flaw detection sensitivity of existing automated ultrasonic inspection system will be determined and the true/false indication ratio optimised. Through systematic investigations with the Probability of Detection method on the existing automated ultrasonic inspection system the results could be directly applied to the optimisation of existing ultrasonic inspections of wheelset axles with a bore hole in maintenance procedures and the level of reliability can be considerably increased.
Motivation: What can we learn from the history of aerospace?
State of the art: Detectability as the basis of probability of failure
Evaluationmethods: Consequences of decisions based on ndt
Advanced approaches: Probability of Detection: Evaluation of ndt systems are important!
Use of the POD: Out of the box: Finnish and Swedish project for final disposal of spent nuclear fuel
Reliability of NDT depends not only on the intrinsic capability of the measuring systems and on the application factors (the conditions under which NDT is applied), but also—and to a great extent—on human factors and the organisational context under which each inspection is carried out.
Adoption of a systematic approach to the identification and prevention of risks.
Critical defects could be missed, even if the inspection process is semi-automated. The causes of that risk lie in the technology, people and in the organisation. Currently installed preventive measures are insufficient to prevent from risks New preventive measures could be installed, e.g. further automation, installing alarms, implementing human redundancy, developing software and hardware solutions, optimising procedures, etc.
Human factors studies are not only essential for the operation but also during the development process.
Over the past couple of decades Non-Destructive Testing (NDT) has seen a significant increase in the use of automation. In addition to increased reliability, objectivity, consistency, repeatability, productivity, and so on, automating parts of the process is expected to decrease the potential for human error. However, the literature on human-automation interaction suggests that automation is not only associated with benefits, but also with new risks and risk sources. First, this paper will present the methodology used to identify—for the first time—possible risks associated with mechanised data acquisition and corresponding data evaluation. Moreover, it will highlight possible risks, their causes, consequences, and ways of preventing them. Second, those preventive measures will be further analysed by examining new risks that can arise from their implementation, i.e. potential for failure that can arise from (a) working with automated defect-detection and sizing aids, (b) implementing human redundancy, and (c) improvement of the inspection procedures without due consideration of the procedure users. And third, some optimisations strategies will be provided. The purpose of this work is to show that mechanised testing is associated with potential for failure and that the sources of those risks go beyond single inspectors and need to be looked at in the interaction of people with other systems, i.e. the technology, the team and, most importantly, the organisation.